Abstract:
OBJECTIVE:Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. MATERIALS AND METHODS:One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. RESULTS:All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). CONCLUSION:Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. KEY POINTS:• CT-guided biopsy is the main procedure to obtain diagnosis in lung tumours. • The robotic device facilitates percutaneous needle placement under CT guidance. • Robot-assisted CT-guided lung biopsy reduces procedure duration and radiation dose.
journal_name
Eur Radioljournal_title
European radiologyauthors
Anzidei M,Argirò R,Porfiri A,Boni F,Anile M,Zaccagna F,Vitolo D,Saba L,Napoli A,Leonardi A,Longo F,Venuta F,Bezzi M,Catalano Cdoi
10.1007/s00330-014-3508-zsubject
Has Abstractpub_date
2015-05-01 00:00:00pages
1310-6issue
5eissn
0938-7994issn
1432-1084journal_volume
25pub_type
杂志文章,随机对照试验abstract:OBJECTIVES:To compare the significance of the two-compartment model, considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS). METHODS:Diffusion-weighted images (nine b-values with six d...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3572-4
更新日期:2015-06-01 00:00:00
abstract::The original version of this article, published on 19 August 2016, unfortunately contained a mistake. ...
journal_title:European radiology
pub_type: 已发布勘误
doi:10.1007/s00330-020-06947-x
更新日期:2020-11-01 00:00:00
abstract::This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between ...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-008-1239-8
更新日期:2009-05-01 00:00:00
abstract::Blunt injury of the extrahepatic bile duct is rare and hence a large series of scientific study of its MRI is difficult to perform. We present the MRI and MR cholangiography of a case of blunt extrahepatic bile duct injury proven at surgery. The diagnosis could be established based on MRI findings of an abrupt taperin...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-001-1296-8
更新日期:2002-10-01 00:00:00
abstract:OBJECTIVES:To compare contrast effects of gadobutrol with gadoterate meglumine for brain MRI in multiple sclerosis (MS) in a multicentre, randomized, prospective, intraindividual study at 3 T. METHODS:Institutional review board approval was obtained. Patients with known or suspected active MS lesions were included. Tw...
journal_title:European radiology
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1007/s00330-015-3889-7
更新日期:2016-03-01 00:00:00
abstract::The advent of radiologic guidance techniques for percutaneous biopsy has changed the approach to the routine diagnosis of mediastinal lymphoma. The aim of the present study was to evaluate the diagnostic accuracy of CT-guided percutaneous core-needle biopsy (PCNB) in the clinical management of patients with mediastina...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050991
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVE:To evaluate the feasibility, image quality, and radiation dose of automatic spectral imaging protocol selection (ASIS) and adaptive statistical iterative reconstruction (ASIR) with reduced contrast agent dose in abdominal multiphase CT. METHODS:One hundred and sixty patients were randomly divided into two sc...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4349-8
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVES:To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS:Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3952-4
更新日期:2016-05-01 00:00:00
abstract::The purpose of our animal study was to evaluate a new computed tomography (CT) subtraction technique for visualization of perfusion defects within the lung parenchyma in subsegmental pulmonary embolism (PE). Seven healthy pigs were entered into a prospective trial. Acute PE was artificially induced by fresh clot mater...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-2718-9
更新日期:2005-07-01 00:00:00
abstract:OBJECTIVES:To determine if radiomic features, alone or combined with clinical data, are associated with residual tumour (RT) at surgery, and predict the risk of disease progression within 12 months (PD12) in ovarian cancer (OC) patients. METHODS:This retrospective study enrolled 101 patients according to the following...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5389-z
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVES:To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. METHODS:Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered b...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4686-7
更新日期:2017-08-01 00:00:00
abstract::The rectum has become the most successful area of the gastrointestinal tract to be studied with MRI. Its anatomical location, fixed in the pelvic fat, and its lack of peristalsis, make it an ideal organ to be scanned with MRI. In addition, MRI allows a direct sagittal and coronal display, of key importance to colorect...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050328
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVES:Given the frequency of abusive fractures among infants, and the lack of research and or evidence for the phases of fracture healing seen in this age group, this study aims to describe a timetable of radiological features of fracture healing among infants in the first months of life. METHODS:We completed a r...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4569-y
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVE:Ultrasound surveillance of patients with testicular microlithiasis (TM) has been advocated following the reported association with testicular cancer. The aim of this study was to assess the evidence base supporting such surveillance. METHODS:Formal literature review identified cohort studies comprising at le...
journal_title:European radiology
pub_type: 杂志文章,meta分析
doi:10.1007/s00330-012-2520-4
更新日期:2012-11-01 00:00:00
abstract:OBJECTIVES:To investigate the hepatobiliary enhancement patterns of gadoxetic acid (Gd-EOB-DTPA) MRI and the temporal evolution of focal nodular hyperplasia (FNH)-like lesions in pediatric cancer survivors. METHODS:We retrospectively included pediatric cancer survivors who had new liver lesions detected during surveil...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07157-1
更新日期:2021-01-01 00:00:00
abstract::Our objective was to find a tracer in diagnosing human pancreatic cancer using positron emission tomography (PET). For this purpose in vitro test of pancreatic tissues with autoradiography was used. Autoradiography was performed with (11)C-harmine (a MAO-A-inhibitor) with and without competitive inhibition. Tissue pre...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1443-x
更新日期:2003-04-01 00:00:00
abstract:OBJECTIVES:To examine repeatability of parameters derived from non-Gaussian diffusion models in data acquired in children with solid tumours. METHODS:Paediatric patients (<16 years, n = 17) were scanned twice, 24 h apart, using DWI (6 b-values, 0-1000 mm-2 s) at 1.5 T in a prospective study. Tumour ROIs were drawn (3 ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4318-2
更新日期:2017-01-01 00:00:00
abstract::In acute nonvariceal gastrointestinal (GI) bleeding, immediate arteriographic haemostasis is presently assumed to be a therapeutic advantage. This study assesses whether the risk of a delayed haemostasis, caused by arteriographic findings precluding embolization, might influence patient outcome. We performed a 5.5-yea...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1882-z
更新日期:2003-12-01 00:00:00
abstract:OBJECTIVE:The apparent diffusion coefficient (ADC) is increasingly used as a quantitative biomarker in oncological imaging. ADC calculation is based on raw diffusion-weighted imaging (DWI) data, and multiple post-processing methods (PPMs) have been proposed for this purpose. We investigated whether PPM has an impact on...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4403-6
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVE:To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 (90Y)-radioembolization for hepatocellular carcinoma (HCC). METHODS:Studies comparing conventional (c)TACE versus 90Y-radioembolization or DEB-TACE for HCC treatment were identified usin...
journal_title:European radiology
pub_type: 杂志文章,meta分析
doi:10.1007/s00330-016-4548-3
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVES:To assess epiphyseal growth plate closure of the knee for forensic age estimation using an ultrasound (US)-based method and to compare the findings with MRI. METHODS:Thirty-three healthy male individuals (age, 14.4-19.3 years) were prospectively evaluated for epiphyseal growth plate closure of the right kne...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07343-1
更新日期:2020-10-14 00:00:00
abstract:OBJECTIVES:This study was conducted in order to establish the joint Society of Abdominal Radiology (SAR) and European Society of Urogenital Radiology (ESUR) guidelines on placenta accreta spectrum (PAS) disorders and propose strategies to standardize image acquisition, interpretation, and reporting for this condition w...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-019-06617-7
更新日期:2020-05-01 00:00:00
abstract:UNLABELLED:Imaging plays an increasingly important role in the early diagnosis, prognosis prediction and therapy response evaluation of central nervous system (CNS) diseases. The newly emerging hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) can perform "one-stop-shop" evaluation, including ana...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-015-4202-5
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investiga...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-2041-y
更新日期:2011-06-01 00:00:00
abstract::Ultrasound has emerged as the primary imaging modality in conditions where either renal obstruction or renal medical disease is suspected on the basis of clinical and laboratory findings. In urinary tract obstruction, pathophysiologic changes affecting the pressure in the collecting system and kidney perfusion are wel...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300101011
更新日期:2001-01-01 00:00:00
abstract::Arteriovenous malformations of the scrotum are extremely rare. A case of scrotal arteriovenous malformation and its preoperative embolization in a child is presented. ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050686
更新日期:1999-01-01 00:00:00
abstract:BACKGROUND:In the vast majority of the laboratory-confirmed coronavirus disease 2019 (COVID-19) patients, computed tomography (CT) examinations yield a typical pattern and the sensitivity of this modality has been reported to be 97% in a large-scale study. Structured reporting systems simplify the interpretation and re...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06863-0
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVES:To assess the risk of lung cancer and specific mortality rate in patients with and without solitary pulmonary nodules (SPN) on chest radiograph and CT. METHODS:This prospective study included 16,078 patients ≥35 years old (893 of them had an SPN detected with either chest radiograph or CT) and 15,185 withou...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3775-3
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVES:This study was conducted in order to assess the performance of the Liver Imaging Reporting and Data System (LI-RADS) treatment response (TR) (LR-TR) categorization on gadoxetic acid-enhanced MRI (Gd-EOB-MRI) for detecting viable tumors in hepatocellular carcinoma (HCC) treated with locoregional treatment (LR...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06623-9
更新日期:2020-05-01 00:00:00
abstract::Incomplete inversion of the hippocampus, an imperfect fetal development, has been described in patients with epilepsy or severe midline malformations. We studied this condition in a nonepileptic population without obvious developmental anomalies. We analyzed the coronal MR images of 50 women and 50 men who did not hav...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-007-0735-6
更新日期:2008-01-01 00:00:00