Radiomics of high-grade serous ovarian cancer: association between quantitative CT features, residual tumour and disease progression within 12 months.

Abstract:

OBJECTIVES:To determine if radiomic features, alone or combined with clinical data, are associated with residual tumour (RT) at surgery, and predict the risk of disease progression within 12 months (PD12) in ovarian cancer (OC) patients. METHODS:This retrospective study enrolled 101 patients according to the following inclusion parameters: cytoreductive surgery performed at our institution (9 May 2007-23 February 2016), assessment of BRCA mutational status, preoperative CT available. Radiomic features of the ovarian masses were extracted from 3D structures drawn on CT images. A phantom experiment was performed to assess the reproducibility of radiomic features. The final radiomic features included in the analysis (n = 516) were grouped into clusters using a hierarchical clustering procedure. The association of each cluster's representative radiomic feature with RT and PD12 was assessed by chi-square test. Multivariate analysis was performed using logistic regression models. P values < 0.05 were considered significant. RESULTS:Patients with values of F2-Shape/Compactness1 below the median, of F1- GrayLevelCooccurenceMatrix25/0-1InformationMeasureCorr2 below the median and of F1-GrayLevelCooccurenceMatrix25/-333-1InverseVariance above the median showed higher risk of RT (36%, 36% and 35%, respectively, as opposed to 18%, 18% and 18%). Patients with values of F4-GrayLevelRunLengthMatrix25/-333RunPercentage above the median, of F2 shape/Max3DDiameter below the median and F1-GrayLevelCooccurenceMatrix25/45-1InverseVariance above the median showed higher risk of PD12 (22%, 24% and 23%, respectively, as opposed to 6%, 5% and 6%). At multivariate analysis F2-Shape/Max3DDiameter remained significant (odds ratio (95% CI) = 11.86 (1.41-99.88)). To predict PD12, a clinical radiomics model performed better than a base clinical model. CONCLUSION:This study demonstrated significant associations between radiomic features and prognostic factors such as RT and PD12. KEY POINTS:• No residual tumour (RT) at surgery is the most important prognostic factor in OC. • Radiomic features related to mass size, randomness and homogeneity were associated with RT. • Progression of disease within 12 months (PD12) indicates worse prognosis in OC. • A model including clinical and radiomic features performed better than only-clinical model to predict PD12.

journal_name

Eur Radiol

journal_title

European radiology

authors

Rizzo S,Botta F,Raimondi S,Origgi D,Buscarino V,Colarieti A,Tomao F,Aletti G,Zanagnolo V,Del Grande M,Colombo N,Bellomi M

doi

10.1007/s00330-018-5389-z

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

4849-4859

issue

11

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-018-5389-z

journal_volume

28

pub_type

杂志文章
  • MR imaging-guided laser ablation of osteoid osteomas with use of optical instrument guidance at 0.23 T.

    abstract::The purpose of this study was to determine the feasibility and features of low-field MR imaging in performing interstitial laser ablation of osteoid osteomas. Between September 2001 and April 2002, five consecutive patients with clinical and imaging findings suggesting osteoid osteoma and referred for removal of osteo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1897-5

    authors: Sequeiros RB,Hyvönen P,Sequeiros AB,Jyrkinen L,Ojala R,Klemola R,Vaara T,Tervonen O

    更新日期:2003-10-01 00:00:00

  • Increased susceptibility of asymmetrically prominent cortical veins correlates with misery perfusion in patients with occlusion of the middle cerebral artery.

    abstract:OBJECTIVES:To evaluate tissue perfusion and venous susceptibility in ischaemic stroke patients as a means to predict clinical status and early prognosis. METHODS:A retrospective study of 51 ischaemic stroke patients were enrolled in this study. Susceptibility, perfusion and National Institute of Health stroke scale (N...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4593-y

    authors: Luo Y,Gong Z,Zhou Y,Chang B,Chai C,Liu T,Han Y,Wang M,Qian T,Haacke EM,Xia S

    更新日期:2017-06-01 00:00:00

  • Double line sign: a helpful sonographic sign to detect occult fractures of the proximal humerus.

    abstract::The aim of this study was to describe a new sonographic sign of bone fracture and to determine if it can be helpful in decreasing the number of missed fractures of the proximal humerus. Ultrasound (US) of the shoulder was performed in 57 consecutive patients with shoulder pain and/or disability following trauma. All c...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0331-1

    authors: Rutten MJ,Jager GJ,de Waal Malefijt MC,Blickman JG

    更新日期:2007-03-01 00:00:00

  • Abnormalities of the airways and lung parenchyma in asthmatics: CT observations in 50 patients and inter- and intraobserver variability.

    abstract::The purpose of the study was to evaluate the CT abnormalities of airways and lung parenchyma in asthmatic patients and to assess inter- and intraobserver variability for these abnormalities. The CT scans of 50 asthmatic patients and 10 healthy volunteers were assessed independently by four independent chest radiologis...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00181147

    authors: Grenier P,Mourey-Gerosa I,Benali K,Brauner MW,Leung AN,Lenoir S,Cordeau MP,Mazoyer B

    更新日期:1996-01-01 00:00:00

  • Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions.

    abstract::The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1269-y

    authors: Obenauer S,Luftner-Nagel S,von Heyden D,Munzel U,Baum F,Grabbe E

    更新日期:2002-07-01 00:00:00

  • Radiological research in Europe: a bibliometric study.

    abstract::We performed a bibliometric search to evaluate number and scientific "weight" of papers written by European radiologists, as compared with colleagues from other countries, to measure the contribution of European researchers to radiology journals, and to correlate bibliometric parameters with some socio-economic factor...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1640-7

    authors: Mela GS,Martinoli C,Poggi E,Derchi LE

    更新日期:2003-04-01 00:00:00

  • Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality.

    abstract:OBJECTIVES:The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. METHODS:An 80 kVp TB protocol for CTCA and CTPA was retros...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3281-z

    authors: Rodrigues JC,Joshi D,Lyen SM,Negus IS,Manghat NE,Hamilton MC

    更新日期:2014-10-01 00:00:00

  • Visual assessment of posterior atrophy development of a MRI rating scale.

    abstract:OBJECTIVE:To develop a visual rating scale for posterior atrophy (PA) assessment and to analyse whether this scale aids in the discrimination between Alzheimer's disease (AD) and other dementias. METHODS:Magnetic resonance imaging of 118 memory clinic patients were analysed for PA (range 0-3), medial temporal lobe atr...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2205-4

    authors: Koedam EL,Lehmann M,van der Flier WM,Scheltens P,Pijnenburg YA,Fox N,Barkhof F,Wattjes MP

    更新日期:2011-12-01 00:00:00

  • Preservation of the endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound ablation of submucosal uterine fibroids.

    abstract:OBJECTIVE:To evaluate the integrity of endometrial enhancement after magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) ablation of submucosal uterine fibroids based on contrast-enhanced MRI findings, and to identify the risk factors for endometrial impairment. METHODS:In total, 117 submucos...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4765-4

    authors: Kim YS,Kim TJ,Lim HK,Rhim H,Jung SH,Ahn JH,Lee JW,Kim BG

    更新日期:2017-09-01 00:00:00

  • Prospective validation of the ultrasound based TIRADS (Thyroid Imaging Reporting And Data System) classification: results in surgically resected thyroid nodules.

    abstract:OBJECTIVE:To assess performance of TIRADS classification on a prospective surgical cohort, demonstrating its clinical usefulness. METHODS:Between June 2009 and October 2012, patients assessed with pre-operative ultrasound (US) were included in this IRB-approved study. Nodules were categorised according to our previous...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4605-y

    authors: Horvath E,Silva CF,Majlis S,Rodriguez I,Skoknic V,Castro A,Rojas H,Niedmann JP,Madrid A,Capdeville F,Whittle C,Rossi R,Domínguez M,Tala H

    更新日期:2017-06-01 00:00:00

  • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

    abstract::The influence of the frequency of computed tomography (CT) image acquisition on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1083-x

    authors: Wiesmann M,Berg S,Bohner G,Klingebiel R,Schöpf V,Stoeckelhuber BM,Yousry I,Linn J,Missler U

    更新日期:2008-12-01 00:00:00

  • Assessment of an advanced virtual monoenergetic reconstruction technique in cerebral and cervical angiography with third-generation dual-source CT: Feasibility of using low-concentration contrast medium.

    abstract:OBJECTIVES:To investigate the feasibility of low-concentration contrast media (LC-CM) in cerebral and cervical dual-energy CT angiography (DE-CTA) using an advanced monoenergetic (Mono+) reconstruction technique. METHODS:Sixty-five consecutive patients prospectively selected to undergo cerebral and cervical DE-CTA wer...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-018-5407-1

    authors: Zhao L,Li F,Zhang Z,Zhang Z,Jiang Y,Wang X,Gu J,Li D

    更新日期:2018-10-01 00:00:00

  • MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

    abstract:OBJECTIVES:Magnetic resonance imaging (MRI) acquired on equipment capable of simultaneous MRI and positron emission tomography (PET) could potentially provide the gold standard method for motion correction of PET. To assess the latter, in this study we compared fast 2D and 3D MRI of the torso and used deformation param...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2274-4

    authors: Dikaios N,Izquierdo-Garcia D,Graves MJ,Mani V,Fayad ZA,Fryer TD

    更新日期:2012-02-01 00:00:00

  • The use of ECG and respiratory triggering to improve the sensitivity of oxygen-enhanced proton MRI of lung ventilation.

    abstract::Changes in lung signal between normal breathing and breathing pure oxygen is the basis for oxygen-enhanced ventilation MRI. An optimal technique guarantees a significant response to pure oxygen in well-ventilated lung tissue. To improve the sensitivity, we investigated the effect of ECG and respiratory triggering. Cen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1694-6

    authors: Vaninbroukx J,Bosmans H,Sunaert S,Demedts M,Delcroix M,Marchal G,Verschakelen J

    更新日期:2003-06-01 00:00:00

  • Radiofrequency thermal ablation with expandable needle of focal liver malignancies: complication report.

    abstract::The aim of this study was to describe type and rate of complications in a series of patients with liver tumors treated by the radiofrequency (RF) expandable system. A total of 166 patients, 114 with hepatocellular carcinoma (HCC; 92 small HCC, 22 large) and 52 with liver metastasis, were treated by the percutaneous RF...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-1990-9

    authors: Buscarini E,Buscarini L

    更新日期:2004-01-01 00:00:00

  • Detection of peritoneal dissemination in gynecological malignancy: evaluation by diffusion-weighted MR imaging.

    abstract::The aim of this study is to evaluate the usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging in detecting peritoneal dissemination in cases of gynecological malignancy. We retrospectively analyzed MR images obtained from 26 consecutive patients with gynecological malignancy. Peritoneal dissemination ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0732-9

    authors: Fujii S,Matsusue E,Kanasaki Y,Kanamori Y,Nakanishi J,Sugihara S,Kigawa J,Terakawa N,Ogawa T

    更新日期:2008-01-01 00:00:00

  • MRI in guiding and assessing intramyocardial therapy.

    abstract::Cardiovascular intervention, using MRI guidance, is challenging for clinical applications. Real-time imaging sequences with high spatial resolution are needed for monitoring intramyocardial delivery of drug, gene, or stem cell therapies. New generation MR scanners make local intramyocardial and vascular wall therapies...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2622-8

    authors: Saeed M,Saloner D,Weber O,Martin A,Henk C,Higgins C

    更新日期:2005-05-01 00:00:00

  • Diagnostic accuracy of low-dose CT compared with abdominal radiography in non-traumatic acute abdominal pain: prospective study and systematic review.

    abstract:OBJECTIVES:Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. METHODS:Fifty-eight patients were...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3984-9

    authors: Alshamari M,Norrman E,Geijer M,Jansson K,Geijer H

    更新日期:2016-06-01 00:00:00

  • High-resolution ultrasound of peripheral neurogenic tumors.

    abstract::Peripheral nerve tumors are not frequent, but due to their association with a nerve they are somewhat special. They may be encountered incidentally during evaluation of a soft-tissue mass or when a nerve lesion is clinically suspected and the recognition of such a lesion and its differential diagnosis is key for succe...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0645-7

    authors: Gruber H,Glodny B,Bendix N,Tzankov A,Peer S

    更新日期:2007-11-01 00:00:00

  • Added value of smooth hypointense rim in the hepatobiliary phase of gadoxetic acid-enhanced MRI in identifying tumour capsule and diagnosing hepatocellular carcinoma.

    abstract:OBJECTIVES:To examine the added value of considering smooth hypointense rim in the hepatobiliary phase (HBP) of gadoxetic acid-enhanced MRI as capsule appearance for diagnosing tumour capsules and hepatocellular carcinoma (HCC). METHODS:A total of 377 hepatic lesions (330 HCCs, 35 non-HCC malignancies and 12 benign) w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4634-6

    authors: An C,Rhee H,Han K,Choi JY,Park YN,Park MS,Kim MJ,Park S

    更新日期:2017-06-01 00:00:00

  • Dynamic MR imaging of osteoid osteomas: correlation of semiquantitative and quantitative perfusion parameters with patient symptoms and treatment outcome.

    abstract:OBJECTIVE:To evaluate the relationship between multiple MR perfusion parameters and symptoms of patients with osteoid osteomas after percutaneous laser therapy. METHODS:MR perfusion studies of 20 patients diagnosed with an osteoid osteoma, treated with CT-guided percutaneous laser therapy, were retrospectively evaluat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2867-1

    authors: Teixeira PA,Chanson A,Beaumont M,Lecocq S,Louis M,Marie B,Sirveaux F,Blum A

    更新日期:2013-09-01 00:00:00

  • Visualization of antigen-specific human cytotoxic T lymphocytes labeled with superparamagnetic iron-oxide particles.

    abstract::New technologies are needed to characterize the migration and survival of antigen-specific T cells in vivo. In this study, we developed a novel technique for the labeling of human cytotoxic T lymphocytes with superparamagnetic iron-oxide particles and the subsequent depiction with a conventional 1.5-T magnetic resonan...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0874-4

    authors: Beer AJ,Holzapfel K,Neudorfer J,Piontek G,Settles M,Krönig H,Peschel C,Schlegel J,Rummeny EJ,Bernhard H

    更新日期:2008-06-01 00:00:00

  • Demystification of AI-driven medical image interpretation: past, present and future.

    abstract::The recent explosion of 'big data' has ushered in a new era of artificial intelligence (AI) algorithms in every sphere of technological activity, including medicine, and in particular radiology. However, the recent success of AI in certain flagship applications has, to some extent, masked decades-long advances in comp...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-018-5674-x

    authors: Savadjiev P,Chong J,Dohan A,Vakalopoulou M,Reinhold C,Paragios N,Gallix B

    更新日期:2019-03-01 00:00:00

  • Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing.

    abstract::Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to elimina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1013-y

    authors: Meyer LT,Boll DT

    更新日期:2008-11-01 00:00:00

  • Profiles of US and CT imaging features with a high probability of appendicitis.

    abstract:OBJECTIVES:To identify and evaluate profiles of US and CT features associated with acute appendicitis. METHODS:Consecutive patients presenting with acute abdominal pain at the emergency department were invited to participate in this study. All patients underwent US and CT. Imaging features known to be associated with ...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-009-1706-x

    authors: van Randen A,Laméris W,van Es HW,ten Hove W,Bouma WH,van Leeuwen MS,van Keulen EM,van der Hulst VP,Henneman OD,Bossuyt PM,Boermeester MA,Stoker J

    更新日期:2010-07-01 00:00:00

  • What are the predictors of clinical success after percutaneous vertebroplasty for osteoporotic vertebral fractures?

    abstract:OBJECTIVES:Osteoporotic vertebral fractures are responsible for acute pain and disability that may persist for more than 2 months. We wanted to identify predicting factors for mid-term outcome after vertebroplasty. METHODS:We included consecutive patients who underwent vertebroplasty for fragility fractures with persi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5274-1

    authors: Denoix E,Viry F,Ostertag A,Parlier-Cuau C,Laredo JD,Cohen-Solal M,Bousson V,Funck-Brentano T

    更新日期:2018-07-01 00:00:00

  • Dysplasia epiphysealis hemimelica of the scaphoid bone.

    abstract::We report a rare case of dysplasia epiphysealis hemimelica (DEH) in the wrist of a 7-year-old boy. Clinical, radiological and histopathological manifestations are discussed. The correct diagnosis of DEH, however, was made by the confrontation of the radiological and pathological data. The radiologist should inform the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050766

    authors: Vanhoenacker F,Morlion J,De Schepper AM,Callewaert E

    更新日期:1999-01-01 00:00:00

  • Structural magnetic resonance imaging in epilepsy.

    abstract::Because of its sensitivity and high tissue contrast, magnetic resonance imaging (MRI) is the technique of choice for structural imaging in epilepsy. In this review the effect of using optimised scanning protocols and the use of high field MR systems on detection sensitivity is discussed. Also, the clinical relevance o...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0710-2

    authors: Deblaere K,Achten E

    更新日期:2008-01-01 00:00:00

  • Correlation of patient survival with clinical tumor measurements in malignant pleural mesothelioma.

    abstract:OBJECTIVES:To evaluate differences in the tumor response classifications that result from clinical measurements and to compare these response classifications with overall survival for patients with malignant pleural mesothelioma (MPM). METHODS:One hundred thirty-one computed tomography (CT) scans were collected from 4...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-018-5887-z

    authors: Li F,Ahmad M,Qayyum F,Straus CM,MacMahon H,Kindler H,Armato SG 3rd

    更新日期:2019-06-01 00:00:00

  • Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients.

    abstract:OBJECTIVES:To assess feasibility, image quality, and radiation dose of prospectively ECG-triggered coronary CT angiography (CTA) in orthotopic heart transplant (OHT) recipients. METHODS:47 consecutive OHT recipients (40 men, mean age 62.1 ± 10.9 years, mean heart rate 86.3 ± 14.4 bpm) underwent dual-source CTA to rule...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2126-2

    authors: Bastarrika G,Broncano J,Arraiza M,Azcárate PM,Simon-Yarza I,Levy Praschker BG,Pueyo JC,Zubieta JL,Rabago G

    更新日期:2011-09-01 00:00:00