Abstract:
OBJECTIVES:To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. METHODS:Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. RESULTS:Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. CONCLUSION:MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. KEY POINTS:• MDCT is an accurate alternative to MRI in disc herniation diagnosis. • By IR enhanced image quality improves MDCT diagnostic confidence similar to MRI. • Advances in CT technology contribute to improved diagnostic performance in lumbar spine imaging.
journal_name
Eur Radioljournal_title
European radiologyauthors
Notohamiprodjo S,Stahl R,Braunagel M,Kazmierczak PM,Thierfelder KM,Treitl KM,Wirth S,Notohamiprodjo Mdoi
10.1007/s00330-016-4686-7subject
Has Abstractpub_date
2017-08-01 00:00:00pages
3443-3451issue
8eissn
0938-7994issn
1432-1084pii
10.1007/s00330-016-4686-7journal_volume
27pub_type
杂志文章abstract:OBJECTIVES:To find predictors of non-diagnostic repeat biopsy specimen acquisition for mutational analysis and detection of epidermal growth factor receptor (EGFR) T790M mutation. METHODS:We retrospectively reviewed 90 non-small cell lung cancer patients harbouring EGFR mutations who underwent repeat cone-beam CT-guid...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5006-6
更新日期:2018-02-01 00:00:00
abstract::The authors describe the discovery of ascending colonic variceal veins via celiomesenteric diagnostic angiography following a bout of melena in a 44-year-old woman. Magnetic resonance imaging, including phase-contrast MR venography, allowed visualization of the portal and systemic veins immediately after the initial a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003309900308
更新日期:2000-01-01 00:00:00
abstract::Hybrid imaging with combined positron emission tomography/computed tomography (PET/CT) plays an important role in the staging and management of a wide variety of solid tumours. However, its use in the evaluation of musculoskeletal malignancy has not yet entered routine clinical practice. Cross-sectional imaging with m...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-010-1862-z
更新日期:2010-12-01 00:00:00
abstract::Positron emission tomography (PET) is a powerful molecular imaging technique for the human body-imaging applications currently available. As altered glucose metabolism is characteristic for many malignancies, FDG-PET is mostly used in oncology for staging and therapy control. Although PET is a sensitive tool for detec...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-005-0088-y
更新日期:2006-05-01 00:00:00
abstract::A new technique is presented for retrograde urethrography (RGU) using a plastic adjustable clamp. The procedure was performed in 36 patients with suspected urethral stenosis. Mean age was 55.3 years. The device and the procedure are described. All the radiologic examinations of the urethra were carried out successfull...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1662-1
更新日期:2003-06-01 00:00:00
abstract:PURPOSE:To assess the role of the MR radiomic signature in preoperative prediction of lymph node (LN) metastasis in patients with esophageal cancer (EC). PATIENTS AND METHODS:A total of 181 EC patients were enrolled in this study between April 2015 and September 2017. Their LN metastases were pathologically confirmed....
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5583-z
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVES:Irreversible electroporation (IRE) is a new ablation technique that relies on high-voltage electrical pulses. This clinical study evaluates the pathological response of colorectal liver metastases (CRLM) treated with IRE and the clinical safety and feasibility. METHODS:Ten patients with resectable CRLM were...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3259-x
更新日期:2014-10-01 00:00:00
abstract:OBJECTIVES:Normative brain volume reports (NBVRs) are becoming more and more available for the workup of dementia patients in clinical routine. However, it is yet unknown how this information can be used in the radiological decision-making process. The present study investigates the diagnostic value of NBVRs for detect...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06602-0
更新日期:2020-05-01 00:00:00
abstract:OBJECTIVES:To assess the inter-operator concordance and the potential sources of discordance in defining response to sorafenib in hepatocellular carcinoma (HCC). METHODS:All patients who received sorafenib between September 2008 and February 2015 were scrutinised for this retrospective study. Images were evaluated sep...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5393-3
更新日期:2018-09-01 00:00:00
abstract::Significant advances have been recently introduced into various fields of technology, taking advantage of the use of new piezoelectric materials and the large diffusion of broadband transducers. Various types of modulation may be applied to the pulse characteristics, using single pulse, multipulse or multiline techniq...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-001-1185-1
更新日期:2002-01-01 00:00:00
abstract::Though long considered unlikely because of the resonance pattern of agents such as SonoVue, high frequency applications for small parts and intracavitary applications now seem very promising. Excellent non-linear signals can be obtained at 7 MHz and higher using recently developed CPS software, and preliminary results...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s10406-004-0084-3
更新日期:2004-10-01 00:00:00
abstract::Iodinated X-ray contrast media are among the most frequently used pharmaceuticals for intravascular administration. Although the newer low osmolality, nonionic contrast media, are generally well tolerated, it is well known that they, like the ionic contrast media, give rise to immediate or delayed adverse reactions in...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300000543
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to examine whether visual MRI rating scales used in diagnostics of cognitive disorders can be estimated computationally and to compare the visual rating scales with their computed counterparts in differential diagnostics. METHODS:A set of volumetry and voxel-based morphometry ima...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06067-1
更新日期:2019-09-01 00:00:00
abstract:OBJECTIVE:Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important prognostic factor in coronary artery disease (CAD). The objective of this study was to evaluate the accuracy of CACS from virtual non-contrast (VNC) imaging generated from ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07677-w
更新日期:2021-01-20 00:00:00
abstract:OBJECTIVES:To assess the coronary atherosclerosis profile by coronary computed tomography angiography (CTA) in patients with end-stage liver disease (ESLD) due to alcohol-related liver disease (ARLD) evaluated for liver transplantation (LT), in a retrospective matched case-controlled cohort study. METHODS:One hundred ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07037-8
更新日期:2021-01-01 00:00:00
abstract:OBJECTIVES:Most existing models that are in use to model hepatic function through assessment of hepatic gadoxetic acid enhancement kinetics do not consider quantitative measures of gadoxetic excretion. We developed a model that allows a simultaneous quantitation of uptake and excretion of liver specific contrast agents...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5500-5
更新日期:2019-01-01 00:00:00
abstract:OBJECTIVES:To determine the correlation between CT measurements of emphysema or peripheral airways and airflow obstruction in chronic obstructive pulmonary disease (COPD). METHODS:PubMed, Embase and Web of Knowledge were searched from 1976 to 2011. Two reviewers independently screened 1,763 citations to identify artic...
journal_title:European radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1007/s00330-012-2480-8
更新日期:2012-10-01 00:00:00
abstract:OBJECTIVES:Pre-therapeutic prediction of outcome is important for clinicians and patients in determining whether selective internal radiation therapy (SIRT) is indicated for hepatic metastases of colorectal cancer (CRC). METHODS:Pre-therapeutic characteristics of 100 patients with colorectal liver metastases (CRLM) tr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3658-7
更新日期:2015-09-01 00:00:00
abstract::Whole-body MRI (WB-MRI) has been successfully applied for oncologic and cardiovascular diagnostics, whereas imaging in myopathies usually employs dedicated protocols restricted to areas of specific interest. In this study, we propose a comprehensive neuromuscular WB-MRI protocol. Eighteen patients with degenerative an...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1071-1
更新日期:2008-12-01 00:00:00
abstract::Modern liver imaging of cancer patients requires an imaging modality that is not only highly sensitive in detecting lesions but also provides reliable characterisation of lesions and thus allows differentiation of metastases from frequently found benign lesions. Conventional ultrasound (US) has a relatively poor sensi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s10406-004-0088-z
更新日期:2004-10-01 00:00:00
abstract::We investigated the consequence of repeated transcatheter arterial chemoembolization (TACE) for coexisting small hepatic hemangioma in the treatment of patients with hepatocellular carcinomas and describe the imaging features of embolized hemangioma on the follow-up Lipiodol CT and MR. Six of 431 patients with biopsy-...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-0074-4
更新日期:2006-06-01 00:00:00
abstract::The evolution of CT can be characterized remarkably well by three phases of developments assigned to the 1970s, 1980s and 1990s. The first decade saw rapid innovations followed by a phase of consolidation and slow growth in the 1980s, and finally a third phase of very rapid development including spiral CT and multirow...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s10406-005-0128-3
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVES:Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. METHODS:Fifty-eight patients were...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-015-3984-9
更新日期:2016-06-01 00:00:00
abstract:OBJECTIVE:The progression of white matter hyperintensities (WMH) varies considerably in adults. In this study, we aimed to predict the progression and related risk factors of WMH based on the radiomics of whole-brain white matter (WBWM). METHODS:A retrospective analysis was conducted on 141 patients with WMH who under...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06676-1
更新日期:2020-06-01 00:00:00
abstract::Three europium-activated phosphors Y2O2S:Eu, Y2O3:Eu, and YVO4:Eu emitting red light were studied to investigate their suitability for radiographic cassettes or digital imaging systems. Screens were prepared from phosphor powders with various coating thicknesses by sedimentation. To assess phosphor light producing eff...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050387
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVES:We aimed to investigate if lesion-specific ischaemia by invasive fractional flow reserve (FFR) can be predicted by an integrated machine learning (ML) ischaemia risk score from quantitative plaque measures from coronary computed tomography angiography (CTA). METHODS:In a multicentre trial of 254 patients, C...
journal_title:European radiology
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1007/s00330-017-5223-z
更新日期:2018-06-01 00:00:00
abstract:OBJECTIVES:To compare tumour enhancement patterns measured using dynamic contrast-enhanced (DCE)-CT with tumour metabolism measured using positron emission tomography (PET)-CT in patients with non-small cell lung cancer (NSCLC) and stable disease after chemotherapy or chemoradiotherapy. METHODS:After treatment, 75 NSC...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2755-0
更新日期:2013-06-01 00:00:00
abstract::The rectum has become the most successful area of the gastrointestinal tract to be studied with MRI. Its anatomical location, fixed in the pelvic fat, and its lack of peristalsis, make it an ideal organ to be scanned with MRI. In addition, MRI allows a direct sagittal and coronal display, of key importance to colorect...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050328
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVES:To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. MATERIAL AND METHODS:Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and exa...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07517-x
更新日期:2020-12-02 00:00:00
abstract::We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagno...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050184
更新日期:1997-01-01 00:00:00