3D Dixon water-fat LGE imaging with image navigator and compressed sensing in cardiac MRI.

Abstract:

OBJECTIVES:To evaluate an image-navigated isotropic high-resolution 3D late gadolinium enhancement (LGE) prototype sequence with compressed sensing and Dixon water-fat separation in a clinical routine setting. MATERIAL AND METHODS:Forty consecutive patients scheduled for cardiac MRI were enrolled prospectively and examined with 1.5 T MRI. Overall subjective image quality, LGE pattern and extent, diagnostic confidence for detection of LGE, and scan time were evaluated and compared to standard 2D LGE imaging. Robustness of Dixon fat suppression was evaluated for 3D Dixon LGE imaging. For statistical analysis, the non-parametric Wilcoxon rank sum test was performed. RESULTS:LGE was rated as ischemic in 9 patients and non-ischemic in 11 patients while it was absent in 20 patients. Image quality and diagnostic confidence were comparable between both techniques (p = 0.67 and p = 0.66, respectively). LGE extent with respect to segmental or transmural myocardial enhancement was identical between 2D and 3D (water-only and in-phase). LGE size was comparable (3D 8.4 ± 7.2 g, 2D 8.7 ± 7.3 g, p = 0.19). Good or excellent fat suppression was achieved in 93% of the 3D LGE datasets. In 6 patients with pericarditis, the 3D sequence with Dixon fat suppression allowed for a better detection of pericardial LGE. Scan duration was significantly longer for 3D imaging (2D median 9:32 min vs. 3D median 10:46 min, p = 0.001). CONCLUSION:The 3D LGE sequence provides comparable LGE detection compared to 2D imaging and seems to be superior in evaluating the extent of pericardial involvement in patients suspected with pericarditis due to the robust Dixon fat suppression. KEY POINTS:• Three-dimensional LGE imaging provides high-resolution detection of myocardial scarring. • Robust Dixon water-fat separation aids in the assessment of pericardial disease. • The 2D image navigator technique enables 100% respiratory scan efficacy and permits predictable scan times.

journal_name

Eur Radiol

journal_title

European radiology

authors

Zeilinger MG,Wiesmüller M,Forman C,Schmidt M,Munoz C,Piccini D,Kunze KP,Neji R,Botnar RM,Prieto C,Uder M,May M,Wuest W

doi

10.1007/s00330-020-07517-x

subject

Has Abstract

pub_date

2020-12-02 00:00:00

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-07517-x

pub_type

杂志文章
  • Larger corpus callosum and reduced orbitofrontal cortex homotopic connectivity in codeine cough syrup-dependent male adolescents and young adults.

    abstract:OBJECTIVES:To characterize interhemispheric functional and anatomical connectivity and their relationships with impulsive behaviour in codeine-containing cough syrup (CCS)-dependent male adolescents and young adults. METHODS:We compared volumes of corpus callosum (CC) and its five subregion and voxel-mirrored homotopi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4465-5

    authors: Qiu YW,Lv XF,Jiang GH,Su HH,Ma XF,Tian JZ,Zhuo FZ

    更新日期:2017-03-01 00:00:00

  • Proper timing for the evaluation of neonatal brain white matter development: a diffusion tensor imaging study.

    abstract:OBJECTIVE:We aimed to determine the timing for assessing birth status of the developing brain (i.e. brain maturity at birth) by exploring the postnatal age-related changes in neonatal brain white matter (WM). METHODS:The institutional review board approved this study and all informed parental consents were obtained. 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5665-y

    authors: Jin C,Li Y,Li X,Wang M,Liu C,Gao J,Sun Q,Qiu D,Zeng L,Zhou X,Li G,Zhang J,Zheng J,Yang J

    更新日期:2019-03-01 00:00:00

  • Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI.

    abstract:OBJECTIVES:To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. METHODS:Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3663-x

    authors: Stankovic Z,Rössle M,Euringer W,Schultheiss M,Salem R,Barker A,Carr J,Langer M,Markl M,Collins JD

    更新日期:2015-09-01 00:00:00

  • Non-invasive quantification of pancreatic exocrine function using secretin-stimulated MRCP.

    abstract::Our objective was to quantify water volume using magnetic resonance cholangiopancreatography (MRCP) sequences and apply this to secretin-stimulated studies with the aim of quantifying pancreatic exocrine function. A commercially available single-shot MRCP sequence was used in conjunction with a body phased-array coil ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1605-x

    authors: Punwani S,Gillams AR,Lees WR

    更新日期:2003-02-01 00:00:00

  • Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method.

    abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100978

    authors: Parodi RC,Sardanelli F,Renzetti P,Rosso E,Losacco C,Ferrari A,Levrero F,Pilot A,Inglese M,Mancardi GL

    更新日期:2002-04-01 00:00:00

  • Migrating transient bone marrow edema syndrome of the knee: MRI findings in a new case.

    abstract::We report a case of transient bone marrow edema syndrome migrating within two different compartments of the same knee. This unusual pattern of migration of the marrow edema, which has been previously described only in three cases of transient osteoporosis, may raise the suspicion of an aggressive disease. Radiologists...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1584-y

    authors: Gaeta M,Mazziotti S,Minutoli F,Vinci S,Blandino A

    更新日期:2002-12-01 00:00:00

  • High-resolution 3D non-contrast-enhanced, ECG-gated, multi-step MR angiography of the lower extremities: comparison with contrast-enhanced MR angiography.

    abstract:OBJECTIVE:To determine the diagnostic value of non-contrast-enhanced, 3D-high-resolution, ECG-gated, multi-step MR angiography (non-ceMRA) of the lower extremities using a modified turbo-spin-echo technique in comparison to 1.0-molar contrast-enhanced MR angiography (ceMRA) in patients with suspected peripheral vascula...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1932-2

    authors: Mohrs OK,Petersen SE,Heidt MC,Schulze T,Schmitt P,Bergemann S,Kauczor HU

    更新日期:2011-02-01 00:00:00

  • Primitive hypoglossal artery: demonstration with digital subtraction-, MR- and CT angiography.

    abstract::The primitive hypoglossal artery (PHA) is a rare persistent carotid-basilar anastomosis. Usually it is found incidentally on angiography, but detection may be of importance for patient management. In the presented case MR- and CT angiography, which to our knowledge have not yet been reported in PHA, provided important...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050322

    authors: Oelerich M,Schuierer G

    更新日期:1997-01-01 00:00:00

  • Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing.

    abstract::Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to elimina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1013-y

    authors: Meyer LT,Boll DT

    更新日期:2008-11-01 00:00:00

  • A new device for retrograde urethrography in the male.

    abstract::A new technique is presented for retrograde urethrography (RGU) using a plastic adjustable clamp. The procedure was performed in 36 patients with suspected urethral stenosis. Mean age was 55.3 years. The device and the procedure are described. All the radiologic examinations of the urethra were carried out successfull...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1662-1

    authors: Berná JD,Berná JD Jr

    更新日期:2003-06-01 00:00:00

  • MRI-CEST assessment of tumour perfusion using X-ray iodinated agents: comparison with a conventional Gd-based agent.

    abstract:OBJECTIVES:X-ray iodinated contrast media have been shown to generate contrast in MR images when used with the chemical exchange saturation transfer (CEST) approach. The aim of this study is to compare contrast enhancement (CE) capabilities and perfusion estimates between radiographic molecules and a Gd-based contrast ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4552-7

    authors: Anemone A,Consolino L,Longo DL

    更新日期:2017-05-01 00:00:00

  • Deep learning for the determination of myometrial invasion depth and automatic lesion identification in endometrial cancer MR imaging: a preliminary study in a single institution.

    abstract:OBJECTIVE:To determine the diagnostic performance of a deep learning (DL) model in evaluating myometrial invasion (MI) depth on T2-weighted imaging (T2WI)-based endometrial cancer (EC) MR imaging (ECM). METHODS:We retrospectively enrolled 530 patients with pathologically proven EC at our institution between January 1,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06870-1

    authors: Chen X,Wang Y,Shen M,Yang B,Zhou Q,Yi Y,Liu W,Zhang G,Yang G,Zhang H

    更新日期:2020-09-01 00:00:00

  • MR angiography: supra-aortic vessels.

    abstract::Magnetic resonance angiography (MRA) has become an imaging modality which comprises various techniques based on two concepts: methods relying on the natural flow effects, the time-of-flight and phase-contrast technique, either in two- or three-dimensional acquisition mode, and the more recently developed contrast-enha...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050834

    authors: Wetzel S,Bongartz G

    更新日期:1999-01-01 00:00:00

  • MR-angiogram-added surface anatomy scanning of superficial cerebral arteriovenous malformations.

    abstract::Our purpose was to evaluate the utility of surface anatomy scanning (SAS) of the brain with superimposition of MR angiograms in the diagnosis and presurgical planning of superficial cerebral arteriovenous malformations (AVMs). We performed SAS in 15 patients with superficial cerebral AVMs. Two-dimensional phase-contra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1299-5

    authors: Tsuchiya K,Katase S,Yoshino A,Hachiya J,Shiokawa Y

    更新日期:2002-09-01 00:00:00

  • Tracheal rupture caused by blunt chest trauma: radiological and clinical features.

    abstract::The aim of this study was to assess radiomorphologic and clinical features of tracheal rupture due to blunt chest trauma. From 1992 until 1998 the radiomorphologic and clinical key findings of all consecutive tracheal ruptures were retrospectively analyzed. The study included ten patients (7 men and 3 women; mean age ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050080

    authors: Kunisch-Hoppe M,Hoppe M,Rauber K,Popella C,Rau WS

    更新日期:2000-01-01 00:00:00

  • Characterisation of intra-articular soft tissue tumours and tumour-like lesions.

    abstract::The aim of this study was to describe a new magnetic resonance imaging (MRI) classification system for intra-articular soft tissue tumours based on the morphology of the lesion, with the aim to aid the differential diagnosis. We performed a retrospective review of 52 consecutive patients presenting to a specialist mus...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0381-4

    authors: Adams ME,Saifuddin A

    更新日期:2007-04-01 00:00:00

  • Quantitative CT detects progression in COPD patients with severe emphysema in a 3-month interval.

    abstract:OBJECTIVES:Chronic obstructive pulmonary disease (COPD) is characterized by variable contributions of emphysema and airway disease on computed tomography (CT), and still little is known on their temporal evolution. We hypothesized that quantitative CT (QCT) is able to detect short-time changes in a cohort of patients w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06577-y

    authors: Konietzke P,Wielpütz MO,Wagner WL,Wuennemann F,Kauczor HU,Heussel CP,Eichinger M,Eberhardt R,Gompelmann D,Weinheimer O

    更新日期:2020-05-01 00:00:00

  • Thrombolysis in the peripheral vascular system.

    abstract::The technique of thrombolysis is now well established, becoming employed increasingly often in disease of the peripheral vasculature, both arterial and venous, in addition to its important role in the treatment of coronary artery thrombosis. This is a general review of its applications in peripheral vascular disease c...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300000705

    authors: Hall TB,Matson M,Belli AM

    更新日期:2001-01-01 00:00:00

  • Quantitative diffusion-weighted MR imaging in the differential diagnosis of breast lesion.

    abstract::The role of diffusion-weighted magnetic resonance imaging (DWI) to differentiate breast lesions in vivo was evaluated. Sixty women (mean age, 53 years) with 81 breast lesions were enrolled. A coronal echo planar imaging (EPI) sequence sensitised to diffusion (b value=1,000 s/mm(2)) was added to standard MR. The mean d...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-007-0621-2

    authors: Marini C,Iacconi C,Giannelli M,Cilotti A,Moretti M,Bartolozzi C

    更新日期:2007-10-01 00:00:00

  • Renal artery blood flow: quantification with breath-hold or respiratory triggered phase-contrast MR imaging.

    abstract::The aim of this study was to evaluate the validity and reproducibility of breath-hold and respiratory triggered phase-contrast (PC) MR imaging techniques in the measurement of renal artery blood flow. In 12 healthy subjects cardiac-gated PC flow measurements were obtained in the renal arteries using a breath-hold and ...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s003300000362

    authors: de Haan MW,Kouwenhoven M,Kessels AG,van Engelshoven JM

    更新日期:2000-01-01 00:00:00

  • Development of pumping emulsification device with glass membrane to form ideal lipiodol emulsion in transarterial chemoembolization.

    abstract:PURPOSE:To evaluate a pumping emulsification device that can improve the physiochemical properties and stability of lipiodol emulsion for conventional transarterial chemoembolization. MATERIALS AND METHODS:A pumping emulsification device constructed of a glass membrane with a hydrophobic surface with pore size of 50 μ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5197-x

    authors: Tanaka T,Masada T,Nishiofuku H,Fukuoka Y,Sato T,Tatsumoto S,Marugami N,Higashi S,Kichikawa K

    更新日期:2018-05-01 00:00:00

  • Neoadjuvant chemotherapy in breast cancer-response evaluation and prediction of response to treatment using dynamic contrast-enhanced and diffusion-weighted MR imaging.

    abstract:OBJECTIVE:To explore the predictive value of MRI parameters and tumour characteristics before neoadjuvant chemotherapy (NAC) and to compare changes in tumour size and tumour apparent diffusion coefficient (ADC) during treatment, between patients who achieved pathological complete response (pCR) and those who did not. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2020-3

    authors: Fangberget A,Nilsen LB,Hole KH,Holmen MM,Engebraaten O,Naume B,Smith HJ,Olsen DR,Seierstad T

    更新日期:2011-06-01 00:00:00

  • Aneurysmal bone cyst of the cervical spine (2008:7b).

    abstract::Aneurysmal bone cysts (ABC) are rare, benign, but locally destructive bone tumors. They occur in the spine in 14% of cases, but only 2% are found in the cervical spine. This case report presents a 16-year-old female with an expansive aneurysmatic bone cyst with extensive bone destruction and instability in the cervica...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0944-7

    authors: Pennekamp W,Peters S,Schinkel C,Kuhnen C,Nicolas V,Muhr G,Frangen TM

    更新日期:2008-10-01 00:00:00

  • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

    abstract::The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, ple...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0562-1

    authors: Das M,Ley-Zaporozhan J,Gietema HA,Czech A,Mühlenbruch G,Mahnken AH,Katoh M,Bakai A,Salganicoff M,Diederich S,Prokop M,Kauczor HU,Günther RW,Wildberger JE

    更新日期:2007-08-01 00:00:00

  • Invasive interval cancers in the Ostergötland Mammographic Screening Programme: radiological analysis.

    abstract::The aim of this study was to find out by radiological analysis whether it is possible to prevent interval cancers in screening programmes without a concomitant increase in false positives. Re-scrutiny of all mammograms of 544 interval cancers was implemented. Blinded re-scrutiny of screening mammograms of 390 interval...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1007/s003300050452

    authors: Vitak B

    更新日期:1998-01-01 00:00:00

  • Correlation of texture analysis of paraspinal musculature on MRI with different clinical endpoints: Lumbar Stenosis Outcome Study (LSOS).

    abstract:OBJECTIVES:The aim of this study was to apply texture analysis (TA) on paraspinal musculature in T2-weighted (T2w) magnetic resonance images (MRI) of symptomatic lumbar spinal stenosis (LSS) patients and correlate the findings with clinical outcome measures. METHODS:Ninety patients were prospectively enrolled in the m...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-018-5552-6

    authors: Mannil M,Burgstaller JM,Held U,Farshad M,Guggenberger R

    更新日期:2019-01-01 00:00:00

  • The Trier mummy Paï-es-tjau-em-aui-nu: radiological and histological findings.

    abstract::The ancient Egyptian mummy Paï-es-tjau-em-aui-nu, now on exhibition in the Rheinische Landesmuseum in Trier, Germany, was examined by conventional X-ray radiography, computed tomography, and digital fluoroscopy. In addition, some tissues were biopsied for further histologic identification. Along with some representati...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1182-4

    authors: Sigmund G,Minas M

    更新日期:2002-07-01 00:00:00

  • Diagnostic value of MRI-derived liver surface nodularity score for the non-invasive quantification of hepatic fibrosis in non-alcoholic fatty liver disease.

    abstract:OBJECTIVES:To assess the accuracy of MRI-derived liver surface nodularity (LSN) score for staging of hepatic fibrosis in patients with non-alcoholic fatty liver disease (NAFLD). METHODS:Forty-seven patients with clinicopathological diagnosis of NAFLD who underwent 1.5-T liver MRI within 12 months of liver biopsy were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07114-y

    authors: Catania R,Furlan A,Smith AD,Behari J,Tublin ME,Borhani AA

    更新日期:2021-01-01 00:00:00

  • Diffusion tensor MR imaging of the cervical spinal cord in patients with multiple sclerosis.

    abstract::Our purpose was to evaluate the ability of diffusion tensor imaging (DTI) to characterize cervical spinal cord white matter (WM) in patients with multiple sclerosis (MS). DTI were obtained in 21 MS patients and 21 control subjects (CS). Regions of interest (ROIs) were placed at C2/3, C3/4, and C4/5 within the right, l...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0672-4

    authors: Ohgiya Y,Oka M,Hiwatashi A,Liu X,Kakimoto N,Westesson PL,Ekholm SE

    更新日期:2007-10-01 00:00:00

  • Dual-energy computed tomography in acute ischemic stroke: state-of-the-art.

    abstract::Dual-energy computed tomography (DECT) allows distinguishing between tissues with similar X-ray attenuation but different atomic numbers. Recent studies demonstrated that this technique has several areas of application in patients with ischemic stroke and a potential impact on patient management. After endovascular st...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07543-9

    authors: Mangesius S,Janjic T,Steiger R,Haider L,Rehwald R,Knoflach M,Widmann G,Gizewski E,Grams A

    更新日期:2020-12-14 00:00:00