LI-RADS treatment response categorization on gadoxetic acid-enhanced MRI: diagnostic performance compared to mRECIST and added value of ancillary features.

Abstract:

OBJECTIVES:This study was conducted in order to assess the performance of the Liver Imaging Reporting and Data System (LI-RADS) treatment response (TR) (LR-TR) categorization on gadoxetic acid-enhanced MRI (Gd-EOB-MRI) for detecting viable tumors in hepatocellular carcinoma (HCC) treated with locoregional treatment (LRT) and to investigate the added value of ancillary features (AFs) to conventional enhancement-based criteria. METHODS:This retrospective study included 183 patients with Gd-EOB-MRI after LRT for HCC and appropriate reference standards for tumor viability (84 viable and 99 nonviable). Two independent radiologists assigned per-lesion mRECIST and TR categories (TR-nonviable, TR-equivocal, or TR-viable) according to the LR-TR algorithm and modified LR-TR algorithms including mLR-TR(TP) allowing transitional phase (TP) washout and mLR-TR(AF) allowing category adjustment by applying AFs. Diagnostic performances of imaging criteria were compared using the Cochran's Q test with post hoc analysis. RESULTS:For detecting viable tumors, LR-TR-viable resulted in sensitivities of 64.5%/39.3% and specificities of 98.0%/98.0% in reviewers 1/2. In comparison to LR-TR-viable, mRECIST-viable, mLR-TR(TP)-viable, and mLR-TR(AF)-viable showed significantly higher sensitivities (92.9%/94.0%, 77.4%/56.6%, and 86.9%/83.3% in reviewers 1/2) (ps < 0.001). The specificity of mRECIST-viable (73.7%/62.6%) was significantly lower than that of LR-TR-viable (ps < 0.001), while those of mLR-TR(TP)-viable and mLR-TR(AF)-viable were greater than 95% (98.0%/96.0% and 97.0%/96.0%), statistically equivalent to LR-TR-viable (ps > 0.05). TR-equivocal was least assigned on mLR-TR(AF) (1.1%/7.7%) than LR-TR (15.8%/32.2%) or mLR-TR(TP) (6.6%/23.5%) in both reviewers. CONCLUSION:The LR-TR algorithm on Gd-EOB-MRI provides a specific diagnosis of viable tumor but with limited sensitivity. By applying AFs in the category adjustment, more sensitive and confident diagnosis can be achieved without significant loss of specificity. KEY POINTS:• The LI-RADS treatment response (LR-TR) algorithm on Gd-EOB-MRI provides a highly specific diagnosis of viable HCC but with limited sensitivity. • The inferior sensitivity of LR-TR-viable category to that of mRECIST can be improved by applying ancillary features in the category adjustment.

journal_name

Eur Radiol

journal_title

European radiology

authors

Kim SW,Joo I,Kim HC,Ahn SJ,Kang HJ,Jeon SK,Lee JM

doi

10.1007/s00330-019-06623-9

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

2861-2870

issue

5

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-019-06623-9

journal_volume

30

pub_type

杂志文章
  • Sclerosing lobular hyperplasia: sonographic pathologic correlation.

    abstract::The objective was to evaluate the sonographic findings of sclerosing lobular hyperplasia (SLH) of the breast and to correlate the sonographic findings and the pathologic features. This study consisted of 9 patients with pathologically proven sclerosing lobular hyperplasia who had undergone a preoperative imaging study...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1732-4

    authors: Cho N,Oh KK,Park KY,Noh TW

    更新日期:2003-07-01 00:00:00

  • Three-color risk stratification for improving the diagnostic accuracy for biliary atresia.

    abstract:OBJECTIVES:It is challenging to early differentiate biliary atresia from other causes of cholestasis. We aimed to develop an algorithm with risk stratification to distinguish biliary atresia from infantile cholestasis. METHODS:In this study, we enrolled infants with cholestasis into 2 subgroups from January 2010 to Ap...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06751-7

    authors: Chen Y,Zhao D,Gu S,Li Y,Pan W,Zhang Y

    更新日期:2020-07-01 00:00:00

  • Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography.

    abstract::The aim of this study was to evaluate the radiation dose given by semicoronal CT of the sacroiliac joints (SIJs) in comparison with axial CT and conventional radiography. The total effective radiation doses given by serial contiguous semicoronal and axial CT, using 5-mm slices, 120 kV and 330 mAs, were determined by m...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1297-7

    authors: Jurik AG,Hansen J,Puhakka KB

    更新日期:2002-11-01 00:00:00

  • Breast MRI: EUSOBI recommendations for women's information.

    abstract:UNLABELLED:This paper summarizes information about breast MRI to be provided to women and referring physicians. After listing contraindications, procedure details are described, stressing the need for correct scheduling and not moving during the examination. The structured report including BI-RADS® categories and furth...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3807-z

    authors: Mann RM,Balleyguier C,Baltzer PA,Bick U,Colin C,Cornford E,Evans A,Fallenberg E,Forrai G,Fuchsjäger MH,Gilbert FJ,Helbich TH,Heywang-Köbrunner SH,Camps-Herrero J,Kuhl CK,Martincich L,Pediconi F,Panizza P,Pina LJ,Pij

    更新日期:2015-12-01 00:00:00

  • Prostate cancer detection among readers with different degree of experience using ultra-high b-value diffusion-weighted Imaging: Is a non-contrast protocol sufficient to detect significant cancer?

    abstract:AIM:To evaluate the accuracy of a T2-weighted (T2w) - and a parallel transmit zoomed b = 2000 s/mm2 (b2000) - diffusion-weighted imaging sequence among three readers with different degrees of experience for prostate cancer (Pca) detection. METHODS:Ninety-three patients with suspected Pca were enrolled. For b2000 a two...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5004-8

    authors: Hausmann D,Aksöz N,von Hardenberg J,Martini T,Westhoff N,Buettner S,Schoenberg SO,Riffel P

    更新日期:2018-02-01 00:00:00

  • Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging.

    abstract:OBJECTIVES:To investigate the diagnostic value of intravoxel incoherent motion (IVIM) DWI for placenta accreta by comparing diffusion and perfusion characteristics of placentas with accreta lesions (APs) with those of normal placentas (NPs). METHODS:Twenty-five pregnant women with AP and 24 with NP underwent 3-T magne...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07200-1

    authors: Bao Y,Pang Y,Sun Z,Li Q,Tang D,Xia L

    更新日期:2021-02-01 00:00:00

  • Longitudinal stress fractures of the tibia: comparative study of CT and MR imaging.

    abstract::The aim of this study was to compare the performance of CT and MRI in the diagnosis of longitudinal stress fracture of the tibia (LSFT). A retrospective study of imaging findings was performed in 15 patients with LSFT. The CT and MR images were compared for detection of fracture line, callus, bone marrow edema, and so...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050442

    authors: Feydy A,Drapé J,Beret E,Sarazin L,Pessis E,Minoui A,Chevrot A

    更新日期:1998-01-01 00:00:00

  • Cell tracking using (19)F magnetic resonance imaging: technical aspects and challenges towards clinical applications.

    abstract::(19)F MRI is emerging as a new imaging technique for cell tracking. It is particularly attractive because of its potential for direct and precise cell quantification. The most important challenge towards in vivo applications is the sensitivity of the technique, i.e. the detection limit in a reasonable imaging time. Op...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3474-5

    authors: Amiri H,Srinivas M,Veltien A,van Uden MJ,de Vries IJ,Heerschap A

    更新日期:2015-03-01 00:00:00

  • Clinical Feasibility of 3D Automated Coronary Atherosclerotic Plaque Quantification Algorithm on Coronary Computed Tomography Angiography: Comparison with Intravascular Ultrasound.

    abstract:OBJECTIVE:To evaluate the diagnostic performance of automated coronary atherosclerotic plaque quantification (QCT) by different users (expert/non-expert/automatic). METHODS:One hundred fifty coronary artery segments from 142 patients who underwent coronary computed tomography angiography (CCTA) and intravascular ultra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3698-z

    authors: Park HB,Lee BK,Shin S,Heo R,Arsanjani R,Kitslaar PH,Broersen A,Dijkstra J,Ahn SG,Min JK,Chang HJ,Hong MK,Jang Y,Chung N

    更新日期:2015-10-01 00:00:00

  • Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications.

    abstract::Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2236-1

    authors: Reimer P,Schneider G,Schima W

    更新日期:2004-04-01 00:00:00

  • Correction to: Patient dose reference levels in surgery: a multicenter study.

    abstract::The original version of this article, published on 01 August 2018, unfortunately contained two mistakes. ...

    journal_title:European radiology

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s00330-018-5713-7

    authors: Greffier J,Etard C,Mares O,Pereira F,Defez D,Duverger C,Branchereau P,Beregi JP,Coulomb R,Larbi A

    更新日期:2019-03-01 00:00:00

  • Sports-related groin pain: evaluation with MR imaging.

    abstract::Our purpose was to assess the role of MRI in evaluating the musculoskeletal system in athletes with chronic pain laterally in the groin of unknown etiology. Magnetic resonance imaging (MRI) of the pubic ring was performed in 11 young athletes (soccer players) with long-standing groin pain. MR findings were compared wi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00619952

    authors: Ekberg O,Sjöberg S,Westlin N

    更新日期:1996-01-01 00:00:00

  • Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

    abstract:UNLABELLED:Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-015-3945-3

    authors: Messina C,Banfi G,Aliprandi A,Mauri G,Secchi F,Sardanelli F,Sconfienza LM

    更新日期:2016-05-01 00:00:00

  • Prophylactic balloon occlusion of internal iliac arteries, common iliac arteries and infrarenal abdominal aorta in pregnancies complicated by placenta accreta: a retrospective cohort study.

    abstract:OBJECTIVES:To evaluate the efficacy of prophylactic balloon occlusion (PBO), and to compare haemostatic effects and perioperative outcomes of PBO of the internal iliac arteries (IIA), common iliac arteries (CIA) and infrarenal abdominal aorta (IAA) in patients with placenta accreta. METHODS:One hundred and ninety-nine...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5527-7

    authors: Li K,Zou Y,Sun J,Wen H

    更新日期:2018-12-01 00:00:00

  • Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    abstract:OBJECTIVES:To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. METHODS:Each QUADAS item was individually defined to adapt it to the special requir...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2763-0

    authors: Schueler S,Walther S,Schuetz GM,Schlattmann P,Dewey M

    更新日期:2013-06-01 00:00:00

  • Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access.

    abstract::The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2322-4

    authors: Geijer H,Persliden J

    更新日期:2004-09-01 00:00:00

  • Bilateral tuberculous otomastoiditis in an immmunocompetent 5-year-old child: CT and MRI findings (2009: 3b).

    abstract::Bilateral tuberculous mastoiditis (TOM) in an immunocompetent child is a very uncommon form of tuberculous infection presentation. This report shows the CT and MR imaging of bilateral tuberculous otomastoiditis consisting of aggressive signs of middle ear and mastoid involvement with bony destruction and periauricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1130-7

    authors: Munoz A,Ruiz-Contreras J,Jimenez A,Maté I,Calvo M,Villafruela M,del-Pozo G

    更新日期:2009-06-01 00:00:00

  • The uptake transporter OATP8 expression decreases during multistep hepatocarcinogenesis: correlation with gadoxetic acid enhanced MR imaging.

    abstract:OBJECTIVES:To clarify the changes in organic anion-transporting polypeptide 8 (OATP8) expression and enhancement ratio on gadoxetic acid-enhanced MR imaging in hepatocellular nodules during multistep hepatocarcinogenesis. METHODS:In imaging analysis, we focused on 71 surgically resected hepatocellular carcinomas (well...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2165-8

    authors: Kitao A,Matsui O,Yoneda N,Kozaka K,Shinmura R,Koda W,Kobayashi S,Gabata T,Zen Y,Yamashita T,Kaneko S,Nakanuma Y

    更新日期:2011-10-01 00:00:00

  • Peritoneal and pleural fluids may appear hyperintense on hepatobiliary phase using hepatobiliary MR contrast agents.

    abstract:AIM:To describe the effect of hepatobiliary-specific MR imaging contrast agent (HBCA) administration on the signal intensity of peritoneal and pleural fluid effusions on T1-weighted MR images. MATERIALS AND METHODS:From October 2015 to May 2016 139 patients (mean 60±10 years old, 69 % males) with peritoneal or pleural...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5261-6

    authors: Ciolina M,Di Martino M,Bruno O,Pommier R,Vilgrain V,Ronot M

    更新日期:2018-07-01 00:00:00

  • Altered energy metabolism after myocardial infarction assessed by 31P-MR-spectroscopy in humans.

    abstract::The value of 31P-magnetic resonance spectroscopy (MRS) as a possible tool to distinguish viable from non-viable tissue after myocardial infarction was analysed in humans. Fifteen patients 3 weeks after anterior myocardial infarction were studied with breath-hold cine MRI and 3D-CSI MRS (1.5 T system). 31P-spectra were...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000316

    authors: Beer M,Sandstede J,Landschütz W,Viehrig M,Harre K,Horn M,Meininger M,Pabst T,Kenn W,Haase A,von Kienlin M,Neubauer S,Hahn D

    更新日期:2000-01-01 00:00:00

  • Endorectal magnetic resonance imaging of prostatic cancer: comparison between fat-suppressed T2-weighted fast spin echo and three-dimensional dual-echo, steady-state sequences.

    abstract::The aim of this study was to develop an endorectal MRI strategy for prostatic cancer. We evaluated the MR images from 44 consecutive prostatic cancer patients treated by radical prostatectomy. Each sequence from every examination was assessed separately with a specific tumor map drawn. Tumor localization, capsular pen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000598

    authors: Ikonen S,Kärkkäinen P,Kivisaari L,Salo JO,Taari K,Vehmas T,Tervahartiala P,Rannikko S

    更新日期:2001-01-01 00:00:00

  • Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality.

    abstract:OBJECTIVES:To study the effect of patient size, body region and modulation strength on tube current and image quality on CT examinations that use automatic tube current modulation (ATCM). METHODS:Ten physical anthropomorphic phantoms that simulate an individual as neonate, 1-, 5-, 10-year-old and adult at various body...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3309-4

    authors: Papadakis AE,Perisinakis K,Damilakis J

    更新日期:2014-10-01 00:00:00

  • In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents.

    abstract:OBJECTIVES:To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). METHODS:In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4245-2

    authors: Tedeschi E,Palma G,Canna A,Cocozza S,Russo C,Borrelli P,Lanzillo R,Angelini V,Postiglione E,Morra VB,Salvatore M,Brunetti A,Quarantelli M

    更新日期:2016-12-01 00:00:00

  • A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

    abstract:OBJECTIVE:The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. MATERIALS AND METHODS:The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0012-5

    authors: Funama Y,Awai K,Miyazaki O,Nakayama Y,Liu D,Goto T,Yamashita Y,Hori S

    更新日期:2006-04-01 00:00:00

  • Using computer-aided detection in mammography as a decision support.

    abstract:OBJECTIVE:To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. METHODS:A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the c...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1821-8

    authors: Samulski M,Hupse R,Boetes C,Mus RD,den Heeten GJ,Karssemeijer N

    更新日期:2010-10-01 00:00:00

  • Comparison of three cut-offs to diagnose clinically significant portal hypertension by liver stiffness in chronic viral liver diseases: a meta-analysis.

    abstract:BACKGROUND:Transient elastography-based liver stiffness value (TE-LSV) has been investigated for assessing clinically significant portal hypertension (CSPH). The aetiology of CSPH is an important factor determining TE-LSV. There is insufficient evidence for selecting cut-off values. AIMS:This study performed a meta-an...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-018-5478-z

    authors: Song J,Ma Z,Huang J,Liu S,Luo Y,Lu Q,Schwabl P,Zykus R,Kumar A,Kitson M

    更新日期:2018-12-01 00:00:00

  • Three-dimensional cholangio-spiral CT demonstration of a post-traumatic bile leak in a child.

    abstract::Bilioma is a rare complication of traumatic liver injury, and the precise site of bile leak is often difficult to demonstrate with a non-invasive technique. We report a case of post-traumatic bile leak in a 15-year-old girl in whom spiral CT after intravenous cholangiography allowed excellent preoperative demonstratio...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050637

    authors: Wicky S,Gudinchet F,Barghouth G,Schnyder P

    更新日期:1999-01-01 00:00:00

  • Assessment of pulmonary venous stenosis after radiofrequency catheter ablation for atrial fibrillation by magnetic resonance angiography: A comparison of linear and cross-sectional area measurements.

    abstract::One of the recognised complications of catheter ablation is pulmonary venous stenosis. The aim of this study was to compare two methods of evaluation of pulmonary venous diameter for follow-up assessment of the above complication: (1) a linear approach evaluating two main diameters of the vein, (2) semiautomatically m...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0358-3

    authors: Tintera J,Porod V,Cihák R,Mlcochová H,Rolencová E,Fendrych P,Kautzner J

    更新日期:2006-12-01 00:00:00

  • One-molar gadolinium chelate (gadobutrol) as a contrast agent for CT angiography of the thoracic and abdominal aorta.

    abstract::The aim of our study was to evaluate the use of a 1-molar gadolinium chelate (gadobutrol) as an alternative contrast medium for computed tomography angiography (CTA) exams of the aorta. CTA exams of the thoracic and/or abdominal aorta were performed on 15 patients with contraindications for the use of iodine who were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0590-5

    authors: Esteban JM,Alonso A,Cervera V,Martínez V

    更新日期:2007-09-01 00:00:00

  • A multifaceted approach to quality in the MRI-directed biopsy pathway for prostate cancer diagnosis.

    abstract:KEY POINTS:• Identify, assure, and measure major sources of variability affecting the MRI-directed biopsy pathway for prostate cancer diagnosis.• Develop strategies to control and minimize variations that impair pathway effectiveness including the performance of main players and team working.• Assure end-to-end quality...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-020-07527-9

    authors: Padhani AR,Schoots IG,Turkbey B,Giannarini G,Barentsz JO

    更新日期:2020-11-25 00:00:00