Abstract:
:Hematocrit distribution and red blood cell aggregation are the major determinants of blood flow in narrow tubes at low flow rates. It has been observed experimentally that in microcirculation the hematocrit distribution is not uniform. This nonuniformity may result from plasma skimming and cell screening effects and also from red cell sedimentation. The goal of the present study is to understand the effect of nonaxisymmetric hematocrit distribution on the flow of human and cat blood in small blood vessels of the microcirculation. Blood vessels are modeled as circular cylindrical tubes. Human blood is described by Quemada's rheological model, in which local viscosity is a function of both the local hematocrit and a structural parameter that is related to the size of red blood cell aggregates. Cat blood is described by Casson's model. Eccentric hematocrit distribution is considered such that the axis of the cylindrical core region of red cell suspension is parallel to the axis of the blood vessel but not coincident. The problem is solved numerically by using finite element method. The calculations predict nonaxisymmetric distribution of velocity and shear stress in the blood vessel and the increase of apparent viscosity with increasing eccentricity of the core.
journal_name
Biorheologyjournal_title
Biorheologyauthors
Das B,Johnson PC,Popel ASdoi
10.1016/S0006-355X(98)00018-3subject
Has Abstractpub_date
1998-01-01 00:00:00pages
69-87issue
1eissn
0006-355Xissn
1878-5034pii
S0006-355X(98)00018-3journal_volume
35pub_type
杂志文章相关文献
BIORHEOLOGY文献大全abstract:BACKGROUND:Leukocytes and platelets typically fulfil their functions through adhesion to the walls of vessels with different size, haematocrit and shear rate. OBJECTIVE:We aimed to investigate differential effects of these variables on leukocyte and platelet adhesion. METHODS:Blood with varying haematocrit was perfus...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-15043
更新日期:2015-01-01 00:00:00
abstract::It has long been recognized that understanding the rheological properties of blood is essential to a full understanding of the function of the circulatory system. Given the difficulty of obtaining carefully controlled measurements in vivo, most of our current concepts of the flow behavior of blood in vivo are based on...
journal_title:Biorheology
pub_type: 杂志文章,评审
doi:
更新日期:2001-01-01 00:00:00
abstract:BACKGROUND:Ultrasound elastography has been widely used to measure liver stiffness. However, the accuracy of liver viscoelasticity obtained by ultrasound elastography has not been well established. OBJECTIVE:To assess the accuracy of ultrasound elastography for measuring liver viscoelasticity and compare to convention...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-16091
更新日期:2016-01-01 00:00:00
abstract::This paper reports a novel, physiologically significant, microfluidic phenomenon generated by nanomolar concentrations of drag-reducing polymers (DRP) dissolved in flowing blood, which may explain previously demonstrated beneficial effects of DRP on tissue perfusion. In microfluidic systems used in this study, DRP add...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-2009-0543
更新日期:2009-01-01 00:00:00
abstract::Mesenchymal stem cells (MSCs) have the potential to differentiate into distinct mesenchymal tissue cells. They are easy to expand while maintaining their undifferentiated state, which suggests that these cells could be an attractive cell source for tissue engineering of cartilage. In vitro high density micromass cultu...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2006-01-01 00:00:00
abstract::Magnitude and time-dependence of the effects of red cell aggregation and sedimentation on the rheology of human blood were studied during low shear (tau W 2.5 to 92 mPa) flow through horizontal tubes (ID 25 to 105 microns). Immediately following reduction of perfusion pressure to a low value the red cell concentration...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1989-26210
更新日期:1989-01-01 00:00:00
abstract::This study aims at quantifying the cellular mechanical properties based on a partitioning of the cytoskeleton in a cortical and a cytosolic compartments. The mechanical response of epithelial cells obtained by magnetocytometry - a micromanipulation technique which uses twisted ferromagnetic beads specifically linked t...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::Rheological measurements on a high molecular weight Hyaluronic Acid (from rooster combs) were performed to obtain information on the viscoelastic and temporary network characteristics of Hyaluronic Acid solutions as a function of the concentration. From rheological experiments, the critical concentration c* and the co...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::Aqueous solutions calf thymus DNA at three concentrations were studied by viscosity measurements at ambient pressure. A gravitational capillary viscometer and a rotating cylinder viscometer were employed. Three polycations were tested as viscosity-reducing agents with measurements from 25°C to 50°C. The most significa...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-140649
更新日期:2014-01-01 00:00:00
abstract::We previously reported that intraarticular injections of hyaluronan (HA), administered prophylactically to dogs in whom knee osteoarthritis had been induced by transection of the anterior cruicate ligament, did not significantly modify the intraarticular pathology but decreased the proteogylcan concentration of the ar...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract:BACKGROUND:Parenteral nutrition (PN) is a hyperosmolar solution composed of glucose, amino acids and a lipid emulsion, which is often used despite well-known side effects and complications. OBJECTIVES:In this study the hypothesis was tested that PN could affect hemorheology. METHODS:The influence of increasing plasma...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-140652
更新日期:2014-01-01 00:00:00
abstract::It has been hypothesized that bone cells have a hyaluronic acid (HA) rich glycocalyx (cell coat or pericellular matrix) and that this contributes to bone cell mechanotransduction via fluid flow. The glycocalyx of bone cells of the MC3T3-E1 osteoblastic cell line and the MLO-Y4 osteocytic cell line were characterized. ...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2003-01-01 00:00:00
abstract::The separation process of blood and RBC suspensions in a hematocrit range between 0.3-0.7 was investigated with a centrifuge allowed to run at low accelerations (100 xg-1000 xg). The position of the interface between the supernatant of plasma and the RBC column was continuously recorded by a new optoelectronic measuri...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1988-251-233
更新日期:1988-01-01 00:00:00
abstract::Plasma fractionation by membrane filtration permits the reinfusion of the patient with his own albumin. In this study, the influence of membrane nature and plasma flux on plasma fractionation in dead-end mode is investigated with acetate hollow fiber filters. It is found that transmembrane pressure TMP rises exponenti...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1991-281-204
更新日期:1991-01-01 00:00:00
abstract:BACKGROUND:Devices gauging viscoelastic properties of blood during coagulation like the thromboelastograph support fundamental research as well as point of care needs. Associated fibrinolysis data are based on endogenous species or plasminogen activator added to a homogeneous sample prior to clot formation. Digestion i...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-15089
更新日期:2016-07-29 00:00:00
abstract::In this paper we shall describe new mechanical models for the deformation of the actin filament bundles in kidney microvilli and osteocytic cell processes to see whether these cellular extensions, like the stereocilia on hair cells in the inner ear, can function as mechanotransducers when subject to physiological flow...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2001-01-01 00:00:00
abstract::We have previously observed a stimulatory effect of fluid shear stress on the regeneration of cultured endothelial cell layers after mechanical denudation. In this study we examined how fluid shear stress affects endothelial cell DNA synthesis during regeneration. Following mechanical denudation of narrow linear areas...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1990-27505
更新日期:1990-01-01 00:00:00
abstract::Mechanical forces can stimulate the production of extracellular matrix molecules. We tested the efficacy of ultrasound to increase proteoglycan synthesis in bovine primary chondrocytes. The ultrasound-induced temperature rise was measured and its contribution to the synthesis was investigated using bare heat stimulus....
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2006-01-01 00:00:00
abstract::We present data which show that fibrin gels are ordered network structures, the porosity of which is determined by the amount of thrombin being present during the activation step preceding gelation. On activation of fibrinogen, fibrinopeptides are released and simultaneously polymers are formed, obeying apparent first...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1984-211-214
更新日期:1984-01-01 00:00:00
abstract::Atherosclerosis is the most frequent cause of death and severe chronic disability in North America and Europe. The atherosclerosis-prone apolipoprotein E (apoE)-deficient mice contain the entire spectrum of lesions observed during atherogenesis. Significant remodelling of the artery occurs in atherosclerosis. The aim ...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2007-01-01 00:00:00
abstract::Adhesion of monocytes (U-937 cells) along a silicone tube deployed with circular ring stents was studied to test the hypothesis that by intentionally inducing swirling flow in an endovascular stent, the adhesion of monocytes would be suppressed. The results revealed that under a normal flow condition, the flow disturb...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-120622
更新日期:2012-01-01 00:00:00
abstract::In micropipette experiments with small capillaries and moderate high pressure difference (approximately 1000 Pa) cell fragmentation (fission) of human red blood cells without hemolysis was observed by TV-system for a large number of fresh red blood cells of different donors. After separation, the fragment moves away f...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1987-24302
更新日期:1987-01-01 00:00:00
abstract::Flow-induced changes in the red cell microstructure of human blood are identified from mechanical and optical evidence. On initiation of steady flow, a new microstructure develops as the shear strain increases through unit strain. This structure is identified with the formation of layers of red cells that slide on pla...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1994-31206
更新日期:1994-03-01 00:00:00
abstract::The rheological properties of the vitreous body of the eye are believed to be a function of composition and to differ among species, as well as to vary regionally within the vitreous. These properties are essential to the mechanical functioning of the eye. Although there are gross, qualitative data on vitreous rheolog...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1992-295-612
更新日期:1992-09-01 00:00:00
abstract::Mechanical forces influence articular cartilage structure by regulating chondrocyte activity. Mechanical stimulation results in activation of an alpha5beta1 integrin dependent intracellular signal cascade involving focal adhesion kinase and protein kinase C, triggering the release of interleukin-4 from the cell. In no...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::Through cardiac looping during embryonic development, human and other vertebrate hearts adopt sinuous curvatures with marked changes in direction of flow at atrial, ventricular and arterial levels. We used magnetic resonance phase velocity mapping to study flow through the hearts of resting volunteers, and Doppler ult...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract:BACKGROUND:Exposure to particulate air pollution is associated with an increased risk of cardiovascular disease. The mechanism by which exposure increases risk is poorly understood but could involve changes in the flow properties of blood. OBJECTIVE:The aim of this investigation was to assess the effect, in rats, of i...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/BIR-14027
更新日期:2014-01-01 00:00:00
abstract::A rigidity index (RI) related to red blood cell deformability was measured by using the hemorheometre. The RI for 13 patients homozygous for sickle cell disease was 109 +/- 44 at 37 degrees C and at atmospheric pO2. The filtration time curve as a function of pO2 is biphasic for sickle cell suspensions. The pO2 at whic...
journal_title:Biorheology
pub_type: 杂志文章
doi:10.3233/bir-1989-26409
更新日期:1989-01-01 00:00:00
abstract::The blood flow immediately adjacent to the wall of a blood vessel or an artificial surface is of great interest. This flow defines the shear stress at the wall and is known to have a great physiological importance. The use of models is a viable method to investigate this flow. However, even in models the shear stress ...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2002-01-01 00:00:00
abstract::The importance of biomechanical forces in regulating normal chondrocyte metabolism is well established and the mechanisms whereby mechanical forces are transduced into biochemical responses by chondrocytes are beginning to be understood. Previous studies have indicated that cyclical mechanical stimulation induces incr...
journal_title:Biorheology
pub_type: 杂志文章
doi:
更新日期:2008-01-01 00:00:00