Evaluation of meniscal tears: fast spin-echo versus conventional spin-echo magnetic resonance imaging.

Abstract:

RATIONALE AND OBJECTIVES:We compared the performance of fast spin-echo (FSE) with conventional spin-echo (CSE) magnetic resonance (MR) imaging sequences in the detection of meniscal tears. METHODS:Seventy-three patients underwent MR examination of the knee for suspected internal derangement. Each patient was scanned with a CSE sequence and one of two FSE sequences. The primary difference between the two FSE sequences consisted of the echo train length (ETL). Thirty-seven patients (group 1) were scanned with the FSE I sequence (ETL = 8), and 36 patients (group 2) were scanned with the FSE II sequence (ETL = 4). Menisci were graded as torn or not torn on the basis of their MR appearance. The sequences were compared with each other and with the surgical findings in 31 patients who underwent arthroscopy. RESULTS:In group 1, there was a significant discrepancy between the CSE and FSE I techniques (p = .006). The FSE I sequence detected only 11 of 19 surgically proven torn menisci as opposed to 18 of 19 detected with the CSE sequence. The FSE II sequence performed significantly better in group 2, with an accuracy equal to that of the CSE sequence. CONCLUSION:FSE sequences are extremely technique dependent with regard to detecting meniscal tears and should not replace CSE sequences in this setting until further studies are performed to optimize the technique.

journal_name

Acad Radiol

journal_title

Academic radiology

authors

Anderson MW,Raghavan N,Seidenwurm DJ,Greenspan A,Drake C

doi

10.1016/s1076-6332(05)80166-7

subject

Has Abstract

pub_date

1995-03-01 00:00:00

pages

209-14

issue

3

eissn

1076-6332

issn

1878-4046

journal_volume

2

pub_type

杂志文章
  • CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). MATERIALS AND METHODS:A total of 480 pati...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.07.018

    authors: Zhao YX,Zuo ZW,Suo HN,Wang JN,Chang J

    更新日期:2016-12-01 00:00:00

  • Establishing a normative atlas of the human lung: computing the average transformation and atlas construction.

    abstract:RATIONALE AND OBJECTIVES:To establish the range of normal for quantitative computed tomography (CT)-based measures of lung structure and function, we seek to develop methods for matching pulmonary structures across individuals and establishing a normative human lung atlas. MATERIALS AND METHODS:In our previous work, w...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.04.025

    authors: Li B,Christensen GE,Hoffman EA,McLennan G,Reinhardt JM

    更新日期:2012-11-01 00:00:00

  • Communicating Radiology Test Results: Are Our Phone Calls Excessive, Just Right, or Not Enough?

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the preferences of radiology and referring provider residents regarding direct communication of radiology test results. METHODS:This Health Insurance Portability and Accountability Act-compliant quality improvement effort was exempt from institutional review board...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.09.015

    authors: Bhatti ZS,Brown RKJ,Kazerooni EA,Davenport MS

    更新日期:2018-03-01 00:00:00

  • Semiautomatic Assessment of the Terminal Ileum and Colon in Patients with Crohn Disease Using MRI (the VIGOR++ Project).

    abstract:RATIONALE AND OBJECTIVES:The objective of this study was to develop and validate a predictive magnetic resonance imaging (MRI) activity score for ileocolonic Crohn disease activity based on both subjective and semiautomatic MRI features. MATERIALS AND METHODS:An MRI activity score (the "virtual gastrointestinal tract ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.12.024

    authors: Puylaert CAJ,Schüffler PJ,Naziroglu RE,Tielbeek JAW,Li Z,Makanyanga JC,Tutein Nolthenius CJ,Nio CY,Pendsé DA,Menys A,Ponsioen CY,Atkinson D,Forbes A,Buhmann JM,Fuchs TJ,Hatzakis H,van Vliet LJ,Stoker J,Taylor SA,Vos

    更新日期:2018-08-01 00:00:00

  • Minimized Radiation and Contrast Agent Exposure for Coronary Computed Tomography Angiography: First Clinical Experience on a Latest Generation 256-slice Scanner.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to evaluate the impact of the latest coronary computed tomography angiography (CCTA) techniques allowing a radiation- and contrast-sparing protocol on image quality in unselected patients referred for exclusion of suspected coronary artery disease (CAD). MATERIALS AND ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.03.015

    authors: Benz DC,Gräni C,Hirt Moch B,Mikulicic F,Vontobel J,Fuchs TA,Stehli J,Clerc OF,Possner M,Pazhenkottil AP,Gaemperli O,Buechel RR,Kaufmann PA

    更新日期:2016-08-01 00:00:00

  • Comparison of core needle breast biopsy techniques: freehand versus three-dimensional US guidance.

    abstract:RATIONALE AND OBJECTIVES:No single method is generally accepted for evaluating the accuracy of breast biopsy techniques before their clinical implementation. The purpose of this study was to test a new process for evaluating biopsy techniques by using it in the evaluation of a prototype three-dimensional ultrasound (US...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(03)80331-8

    authors: Smith WL,Surry KJ,Kumar A,McCurdy L,Downey DB,Fenster A

    更新日期:2002-05-01 00:00:00

  • A perspective on radiology residency curriculum guidelines: results of the 1995 survey of program directors.

    abstract:RATIONALE AND OBJECTIVES:The development of curriculum guidelines for radiology residency has been found to be favored by 80% of program directors (PDs) nationwide. I surveyed PDs to develop a consensus of opinion concerning minimum training requirements in the subspecialty rotations. METHODS:A survey developed by mem...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(96)80013-4

    authors: Rao VM

    更新日期:1996-06-01 00:00:00

  • Automated diffusion tensor tractography: implementation and comparison to user-driven tractography.

    abstract:RATIONALE AND OBJECTIVES:Diffusion tensor tractography offers a unique perspective of white matter anatomy, but proper delineation of white matter tracts of interest generally requires the active involvement of an expert neuroanatomist. The investigators describe the implementation of an automated tractographic method ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.01.002

    authors: Nucifora PG,Wu X,Melhem ER,Gur RE,Gur RC,Verma R

    更新日期:2012-05-01 00:00:00

  • Intraindividual comparison of two methods of volumetric breast composition assessment.

    abstract:RATIONALE AND OBJECTIVES:To compare the results of two software-based methods, Quantra and Volpara, for volumetric breast composition assessment. MATERIALS AND METHODS:Four hundred forty-five normal, bilateral, two-view, digital mammograms were included. Breast volume (BV), fibroglandular tissue volume (FTV), and perc...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.12.003

    authors: Schmachtenberg C,Hammann-Kloss S,Bick U,Engelken F

    更新日期:2015-04-01 00:00:00

  • Optimal ECG trigger point in electron-beam CT studies: three methods for minimizing motion artifacts.

    abstract:RATIONALE AND OBJECTIVES:The authors hypothesized that electrocardiographic triggering near end systole could minimize motion artifacts in electron-beam computed tomography (CT) of the coronary artery. MATERIALS AND METHODS:The study included 2,660 patients who underwent coronary artery calcium scanning with electron-...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(03)80722-5

    authors: Mao S,Budoff MJ,Bin L,Liu SC

    更新日期:2001-11-01 00:00:00

  • Pulmonary functional magnetic resonance imaging: asthma temporal-spatial maps.

    abstract:RATIONALE AND OBJECTIVES:Hyperpolarized (3)He magnetic resonance imaging (MRI) previously revealed the temporal and spatial heterogeneity of ventilation defects in asthmatics, but these findings have not been used in treatment studies or to guide personalized therapy. Our objective was to exploit the temporal and spati...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.08.002

    authors: Svenningsen S,Guo F,Kirby M,Choy S,Wheatley A,McCormack DG,Parraga G

    更新日期:2014-11-01 00:00:00

  • Estimation of volumes of distribution and intratumoral ethanol concentrations by computed tomography scanning after percutaneous ethanol injection.

    abstract:RATIONALE AND OBJECTIVES:We developed a technique for estimating the volumes of distribution and intratumoral ethanol concentrations using computed tomography (CT) scanning in patients undergoing percutaneous ethanol injection (PEI) treatment of malignant hepatic tumors. METHODS:A phantom containing anhydrous ethanol ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/S1076-6332(96)80333-3

    authors: Alexander DG,Unger EC,Seeger SJ,Karmann S,Krupinski EA

    更新日期:1996-01-01 00:00:00

  • Influence of Cardiovascular Risk Factors on the Prevalence of Coronary Atherosclerosis in Patients with Angiographically Normal Coronary Arteries.

    abstract:RATIONALE AND OBJECTIVES:Cardiovascular (CV) disease is predominately influenced by CV risk factors and coronary computed tomography angiography (CTA) is capable of detecting early-stage coronary artery disease. We sought to determine the influence of CV risk factors on the prevalence of nonobstructive atherosclerosis ...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2016.12.005

    authors: Bittner DO,Klinghammer L,Marwan M,Schmid J,Layritz C,Hoffmann U,Achenbach S,Pflederer T

    更新日期:2017-05-01 00:00:00

  • The "Look Ahead" Technique: A Novel Way to Engage Medical Students in the Radiology Reading Room.

    abstract:RATIONALE AND OBJECTIVES:Engaging medical students during a radiology course can be challenging. We sought a way to actively engage students with live cases, allow them to interact with the picture archiving and communication system workstation, and experience what it is like to be a radiologist. MATERIALS AND METHODS...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2019.12.021

    authors: Huang J,Bingham B,Jordanov M

    更新日期:2021-02-01 00:00:00

  • Prospective Multiparametric Magnetic Resonance Monitoring of Changes in Lesions of Hyaline Cartilage of the Knee Joint After Treatment by Microfractures and Implantation of Biological Collagen Type I Matrix Implants .

    abstract:RATIONALE AND OBJECTIVES:This study's aims were to depict changes in cartilage quality after surgical intervention using magnetic resonance (MR) examination and in content of glycosaminoglycans chains (GAGs) after two types of surgeries - chondral defect treatment by microfractures and scaffold implantation in combinat...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2020.05.030

    authors: Šprláková-Puková A,Štouračová A,Repko M,Koriťáková E,Tintěra J,Dostál M,Otaševič T

    更新日期:2020-06-30 00:00:00

  • Clinical evaluation of wavelet-compressed digitized screen-film mammography.

    abstract:RATIONALE AND OBJECTIVES:The authors compared diagnostic accuracy and callback rates with conventional screen-film mammograms and wavelet-compressed digitized images. MATERIALS AND METHODS:Sixty sets of mammograms (four views per case) were digitized at a spatial resolution of 100 microm. The images were wavelet compr...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/s1076-6332(00)80004-5

    authors: Powell KA,Mallasch PG,Obuchowski NA,Kerczewski RJ,Ganobcik SN,Cardenosa G,Chilcote W

    更新日期:2000-05-01 00:00:00

  • Molecular PET/CT imaging-guided radiation therapy treatment planning.

    abstract::The role of positron emission tomography (PET) during the past decade has evolved rapidly from that of a pure research tool to a methodology of enormous clinical potential. (18)F-fluorodeoxyglucose (FDG)-PET is currently the most widely used probe in the diagnosis, staging, assessment of tumor response to treatment, a...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2009.02.014

    authors: Zaidi H,Vees H,Wissmeyer M

    更新日期:2009-09-01 00:00:00

  • Cerebrospinal Fluid Amyloid Beta, Tau Levels, Apolipoprotein, and 1H-MRS Brain Metabolites in Alzheimer's Disease: A Systematic Review.

    abstract:BACKGROUND:There is compelling evidence that neurochemical changes measured by proton magnetic resonance spectroscopy (1H-MRS) occur at different phases of Alzheimer's disease (AD). However, the extent to which these neurochemical changes are associated with validated AD biomarkers and/or apolipoprotein (APOE) ε4 is ye...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2020.06.006

    authors: Piersson AD,Mohamad M,Rajab F,Suppiah S

    更新日期:2020-07-07 00:00:00

  • Mesoscopic fluorescence tomography of a photosensitizer (HPPH) 3D biodistribution in skin cancer.

    abstract:RATIONALE AND OBJECTIVES:Photodynamic therapy (PDT) is a promising strategy for treating cancer. PDT involves three components: a photosensitizer (PS) drug, a specific wavelength of drug-activating light, and oxygen. A challenge in PDT is the unknown biodistribution of the PS in the target tissue. In this preliminary s...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2013.11.009

    authors: Ozturk MS,Rohrbach D,Sunar U,Intes X

    更新日期:2014-02-01 00:00:00

  • Using the Analytic Hierarchy Process for Prioritizing Imaging Tests in Diagnosis of Suspected Appendicitis.

    abstract:RATIONALE AND OBJECTIVES:In clinical guideline or criteria development processes, such as those used in developing American College of Radiology Appropriateness Criteria (ACR AC), experts subjectively evaluate benefits and risks associated with imaging tests and make complex decisions about imaging recommendations. The...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.01.001

    authors: Agapova M,Bresnahan BW,Linnau KF,Garrison LP Jr,Higashi M,Kessler L,Devine B

    更新日期:2017-05-01 00:00:00

  • Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

    abstract:RATIONALE AND OBJECTIVES:To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATER...

    journal_title:Academic radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.acra.2013.09.015

    authors: Treglia G,Sadeghi R,Annunziata S,Lococo F,Cafarotti S,Bertagna F,Prior JO,Ceriani L,Giovanella L

    更新日期:2014-01-01 00:00:00

  • "Structure-Function Imaging of Lung Disease Using Ultrashort Echo Time MRI".

    abstract:RATIONALE AND OBJECTIVES:The purpose of this review is to acquaint the reader with recent advances in ultrashort echo time (UTE) magnetic resonance imaging (MRI) of the lung and its implications for pulmonary MRI when used in conjunction with functional MRI technique. MATERIALS AND METHODS:We provide an overview of re...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2018.12.007

    authors: Torres L,Kammerman J,Hahn AD,Zha W,Nagle SK,Johnson K,Sandbo N,Meyer K,Schiebler M,Fain SB

    更新日期:2019-03-01 00:00:00

  • Perfusion CT estimates photosensitizer uptake and biodistribution in a rabbit orthotopic pancreatic cancer model: a pilot study.

    abstract:RATIONALE AND OBJECTIVES:It was hypothesized that perfusion computed tomography (CT), blood flow (BF), blood volume (BV), and vascular permeability surface area (PS) product parameters would be predictive of therapeutic anticancer agent uptake in pancreatic cancer, facilitating image-guided interpretation of human trea...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.12.014

    authors: Elliott JT,Samkoe KS,Gunn JR,Stewart EE,Gardner TB,Tichauer KM,Lee TY,Hoopes PJ,Pereira SP,Hasan T,Pogue BW

    更新日期:2015-05-01 00:00:00

  • Determining optimal acquisition parameters for computed tomography coronary angiography: evaluation of a software-assisted, breathhold exam simulation.

    abstract:RATIONALE AND OBJECTIVES:Scanning parameters used in multislice computed tomographic (MSCT) coronary angiography should be adapted to patients' heart rates. The aim of this study was to evaluate the rate of success of a software-assisted scan simulation to determine optimal gantry rotation time prior to MSCT coronary a...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2008.08.016

    authors: Engelken FJ,Lembcke A,Hamm B,Dewey M

    更新日期:2009-02-01 00:00:00

  • A comparative study of HRCT image metrics and PFT values for characterization of ILD and COPD.

    abstract:RATIONALE AND OBJECTIVES:The aim of this study was to compare the performance of various image-based metrics computed from thoracic high-resolution computed tomography (HRCT) with data from pulmonary function testing (PFT) in characterizing interstitial lung disease (ILD) and chronic obstructive pulmonary disease (COPD...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2012.03.007

    authors: Song G,Mortani Barbosa E Jr,Tustison N,Gefter WB,Kreider M,Gee JC,Torigian DA

    更新日期:2012-07-01 00:00:00

  • Correlation of HER-2/neu overexpression with mammography and age distribution in primary breast carcinomas.

    abstract:RATIONALE AND OBJECTIVES:HER-2/neu is a valuable prognostic and therapeutic marker in primary breast carcinoma. The objective of this study was to determine the mammographic and patient characteristics (age) that correlate with HER-2/neu overexpression in primary breast carcinoma. MATERIALS AND METHODS:HER-2/neu chara...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2006.06.015

    authors: Seo BK,Pisano ED,Kuzimak CM,Koomen M,Pavic D,Lee Y,Cole EB,Lee J

    更新日期:2006-10-01 00:00:00

  • A comparison of internally water-perfused and cryogenically cooled monopolar and bipolar radiofrequency applicators in ex vivo liver samples.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the ex vivo ablation zones created in hepatic tissue using monopolar and bipolar gas- and water-cooled radiofrequency (RF) applicators. MATERIALS AND METHODS:RF ablations were performed on ex vivo bovine liver tissue using closed circuit water-cooled and closed circuit cryogenicall...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2014.02.004

    authors: Rempp H,Mezger D,Voigtlaender M,Scharpf M,Hoffmann R,Pereira PL,Enderle MD,Claussen CD,Clasen S

    更新日期:2014-05-01 00:00:00

  • Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneumothorax: Impact of Reader Expertise and Medical Specialty.

    abstract:RATIONALE AND OBJECTIVES:This study aimed to determine the value of dual-energy thoracic radiography in the diagnosis of pneumothorax considering the reader's experience. MATERIALS AND METHODS:Forty patients with a suspected pneumothorax, imaged with dual-energy chest radiographs, were divided into two groups: those w...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2017.06.015

    authors: Urbaneja A,Dodin G,Hossu G,Bakour O,Kechidi R,Gondim Teixeira P,Blum A

    更新日期:2018-01-01 00:00:00

  • Detection of age-dependent changes in healthy adult lungs with diffusion-weighted 3He MRI.

    abstract:RATIONALE AND OBJECTIVES:To investigate changes in lung microstructure in healthy adult subjects with no smoking history using diffusion-weighted 3He MRI. MATERIALS AND METHODS:Diffusion magnetic resonance imaging using hyperpolarized helium 3 (3He) was applied to healthy volunteers to explore the dependence of lung m...

    journal_title:Academic radiology

    pub_type: 杂志文章

    doi:10.1016/j.acra.2005.08.005

    authors: Fain SB,Altes TA,Panth SR,Evans MD,Waters B,Mugler JP 3rd,Korosec FR,Grist TM,Silverman M,Salerno M,Owers-Bradley J

    更新日期:2005-11-01 00:00:00

  • Extracoronary Thoracic and Coronary Artery Calcifications on Chest CT for Lung Cancer Screening: Association with Established Cardiovascular Risk Factors - The "CT-Risk" Trial.

    abstract:RATIONALE AND OBJECTIVES:To investigate the correlation between prevalence and degree of coronary artery calcification (CAC) and extracoronary calcifications (ECCs), scored quantitatively according to Agatston and semiquantitatively by visual analysis, in chest computed tomography (CT) studies obtained for lung cancer ...

    journal_title:Academic radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.acra.2015.03.005

    authors: Dirrichs T,Penzkofer T,Reinartz SD,Kraus T,Mahnken AH,Kuhl CK

    更新日期:2015-07-01 00:00:00