Lumbar spine maximum efforts and muscle recruitment patterns predicted by a model with multijoint muscles and joints with stiffness.

Abstract:

:The transmission of load through the lumbar spine was analyzed in a model of the five lumbar vertebrae, the sacrum/pelvis and the thorax, and 66 symmetric pairs of multijoint muscles. The model was used to test the hypotheses that (1) the need to maintain equilibrium simultaneously at all vertebral levels precludes simultaneous maximum activation of synergistic muscles and (2) that the maximum loads which could be carried by the spine and the degree of muscle activation increases with increasing motion segment stiffness. Maximum moments applied to T12 were calculated for moments in three principal directions, subject to equilibrium at all six joints and to constraints on the maximum muscle stress and intervertebral displacements. A model with realistic motion segment stiffness predicted maximum efforts between 1.4 and 3.3 times greater than a model with 'ball-and-socket' joints, and in better agreement with published results from maximum effort experiments. The differences in maximal effort were greater than the moments transmitted through the joints. While muscle activation levels were greater, many synergistic muscles were still submaximally activated. Antagonistic muscles were recruited to maintain multijoint equilibrium. We concluded that (1) muscle activations permitted in single anatomic level analyses are generally not compatible with equilibrium at other levels; (2) the effect of moment transmission in the joints gives a more realistic representation of the lumbar spine.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Stokes IA,Gardner-Morse M

doi

10.1016/0021-9290(94)e0040-a

subject

Has Abstract

pub_date

1995-02-01 00:00:00

pages

173-86

issue

2

eissn

0021-9290

issn

1873-2380

pii

0021929094E0040A

journal_volume

28

pub_type

杂志文章
  • Characterising skeletal muscle under large strain using eccentric and Fourier Transform-rheology.

    abstract::Characterising the passive anisotropic properties of soft tissues has been largely limited to the linear viscoelastic regime and shear loading is rarely done in the large deformation regime, despite the physiological significance of such properties. This paper demonstrates the use of eccentric rheology, which allows t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.025

    authors: Tan K,Cheng S,Jugé L,Bilston LE

    更新日期:2015-11-05 00:00:00

  • The effect of chemically defined medium on spontaneous calcium signaling of in situ chondrocytes during long-term culture.

    abstract::Chemically defined serum-free medium has been shown to better maintain the mechanical integrity of articular cartilage explants than serum-supplemented medium during long-term in vitro culture, but little is known about its effect on cellular mechanisms. We hypothesized that the chemically defined culture medium could...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.005

    authors: Zhou Y,Park M,Cheung E,Wang L,Lu XL

    更新日期:2015-04-13 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • PDGF-BB, IGF-I and mechanical load stimulate DNA synthesis in avian tendon fibroblasts in vitro.

    abstract::Resident cells in the surface epitenon and internal compartment of flexor tendons are subjected to cyclic mechanical load as muscle contracts to move limbs or digits. Tendons are largely tensile load bearing tissues and are highly matrix intensive with nondividing cells providing maintenance functions. However, when a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00098-4

    authors: Banes AJ,Tsuzaki M,Hu P,Brigman B,Brown T,Almekinders L,Lawrence WT,Fischer T

    更新日期:1995-12-01 00:00:00

  • Sensitivity of ACL volume and T2∗ relaxation time to magnetic resonance imaging scan conditions.

    abstract::Anterior cruciate ligament (ACL) volume and T2∗ relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T2∗ relaxati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.03.010

    authors: Beveridge JE,Walsh EG,Murray MM,Fleming BC

    更新日期:2017-05-03 00:00:00

  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • Concurrent validity and reliability of a mobile tracking technology to measure angular and linear movements of the neck.

    abstract::The neck can be moved in six degrees of freedom. Current 3D-optoelectronic motion-capture systems capable of measuring these movements are inappropriate for use in clinical practice because they are stationary, expensive and time-consuming. We therefore developed a less complex 3D-tracking technology based on Steam®VR...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109340

    authors: Sommer BB,Weisenhorn M,Ernst MJ,Meichtry A,Rast FM,Kleger D,Schmid P,Lünenburger L,Bauer CM

    更新日期:2019-11-11 00:00:00

  • A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

    abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90022-7

    authors: Lippert FG 3rd,Harrington RM,Veress SA,Fraser C,Green D,Bahniuk E

    更新日期:1982-01-01 00:00:00

  • Robotic simulation of identical athletic-task kinematics on cadaveric limbs exhibits a lack of differences in knee mechanics between contralateral pairs.

    abstract::Limb asymmetry is a known factor for increased ACL injury risk. These asymmetries are normally observed during in vivo testing. Prior studies have developed in vitro testing methodologies driven by in vivo kinematics to investigate knee mechanics relative to ACL injury. The objective of this study was to determine if ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.12.019

    authors: Bates NA,McPherson AL,Nesbitt RJ,Shearn JT,Myer GD,Hewett TE

    更新日期:2017-02-28 00:00:00

  • Random field assessment of inhomogeneous bone mineral density from DXA scans can enhance the differentiation between postmenopausal women with and without hip fractures.

    abstract::Bone mineral density (BMD) measurements from Dual-energy X-ray Absorptiometry (DXA) alone cannot account for all factors associated with the risk of hip fractures. For example, the inhomogeneity of bone mineral density in the hip region also contributes to bone strength. In the stochastic assessment of bone inhomogene...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.030

    authors: Dong XN,Pinninti R,Lowe T,Cussen P,Ballard JE,Di Paolo D,Shirvaikar M

    更新日期:2015-04-13 00:00:00

  • Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.038

    authors: Bryan R,Nair PB,Taylor M

    更新日期:2009-09-18 00:00:00

  • Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

    abstract::This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses pa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.011

    authors: Meirson T,Orion E,Avrahami I

    更新日期:2015-07-16 00:00:00

  • Further evidence for the dynamic stability of intracranial saccular aneurysms.

    abstract::It has long been thought that intracranial saccular aneurysms enlarge and rupture because of mechanical instabilities. Recent nonlinear analyses suggest, however, that at least certain sub-classes of aneurysms do not exhibit quasi-static limit point instabilities or dynamic instabilities in response to periodic loadin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00083-6

    authors: David G,Humphrey JD

    更新日期:2003-08-01 00:00:00

  • On the anisotropy of the canine diaphragmatic central tendon.

    abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90289-y

    authors: Chuong CJ,Sacks MS,Johnson RL Jr,Reynolds R

    更新日期:1991-01-01 00:00:00

  • Using directional statistics to test hypotheses regarding rigid body attitude: Comparison to univariate and multivariate Cardan angle tests.

    abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109976

    authors: Pataky TC,Challis JH

    更新日期:2020-10-09 00:00:00

  • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement.

    abstract::Nonconformity between the polyethylene liner and the metal shell may exist in modular acetabular components by design, due to manufacturing tolerances, or from locking mechanisms that attach the polyethylene liner to the metal shell. Relative motion at the liner/shell interface has been associated with backside wear, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00030-x

    authors: Kurtz SM,Ochoa JA,White CV,Srivastav S,Cournoyer J

    更新日期:1998-05-01 00:00:00

  • Quantitative detection of cartilage surfaces and ligament geometry of the wrist using an imaging cryomicrotome system.

    abstract::Biomechanical models may aid in improving diagnosis and treatment of wrist joint disorders. As input, geometrical information is required for model development. Previous studies acquired some elements of the average wrist joint geometry. However, there is a close geometric functional match between articulating surface...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.003

    authors: Dvinskikh NA,Blankevoort L,Foumani M,Spaan JA,Streekstra GJ

    更新日期:2010-03-22 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Non-periodicity of blood flow and its influence on wall shear stress in the carotid artery bifurcation: An in vivo measurement-based computational study.

    abstract::Although arterial blood flow is physiologically non-periodic under resting conditions, periodic flow assumption has been widely adopted in most hemodynamic studies. So far, it remains unclear how the non-periodicity of blood flow would influence local hemodynamic parameters, especially wall shear stress (WSS) that ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109617

    authors: Zhou X,Yin L,Xu L,Liang F

    更新日期:2020-03-05 00:00:00

  • Gait variability magnitude but not structure is altered in essential tremor.

    abstract::Essential tremor (ET) is a common tremor disorder affecting postural/action tremor of the upper extremities and midline. Recent research revealed a cerebellar-like deficit during tandem gait in persons with ET, though spatiotemporal variability during normal gait in ET has been relatively ignored. The first purpose of...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.07.039

    authors: Roemmich RT,Zeilman PR,Vaillancourt DE,Okun MS,Hass CJ

    更新日期:2013-10-18 00:00:00

  • Effects of fixation and preservation on tissue elastic properties measured by quantitative optical coherence elastography (OCE).

    abstract::Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.013

    authors: Ling Y,Li C,Feng K,Duncan R,Eisma R,Huang Z,Nabi G

    更新日期:2016-05-03 00:00:00

  • Explaining Parkinsonian postural sway variabilities using intermittent control theory.

    abstract::Postural impairment due to neuro-degenerative disorders such as Parkinson's Disease (PD) leads to restricted gait patterns, fall-related injuries, decreased mobility, and loss of functional independence. Though several clinical and posturographic studies have attempted to reveal the complex pathophysiology involved in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109791

    authors: Dash R,Shah VV,Palanthandalam-Madapusi HJ

    更新日期:2020-05-22 00:00:00

  • Hip extension, knee flexion paradox: a new mechanism for non-contact ACL injury.

    abstract::Considering that an athlete performs at-risk sports activities countless times throughout the course of his or her career prior to the instance of anterior cruciate ligament (ACL) injury, one may conclude that non-contact ACL injury is a rare event. Nevertheless, the overall number of non-contact ACL injuries, both in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.11.013

    authors: Hashemi J,Breighner R,Chandrashekar N,Hardy DM,Chaudhari AM,Shultz SJ,Slauterbeck JR,Beynnon BD

    更新日期:2011-02-24 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow.

    abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.025

    authors: Lemaire T,Pham TT,Capiez-Lernout E,de Leeuw NH,Naili S

    更新日期:2015-09-18 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • Biomechanical and structural properties of the explanted bioprosthetic valve leaflets.

    abstract::Porcine bioprosthesis were treated with 0.625% glutaraldehyde and stabilized under changing pressure from 4 to 30 mmHg. Bovine pericardium and 12 biovalves (of age between 14 days and 80 months) after implantation in the human body were investigated (7 porcine PB and 5 pericardial bioprosthesis--PCB). Circumferential ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90027-2

    authors: Purinya B,Kasyanov V,Volkolakov J,Latsis R,Tetere G

    更新日期:1994-01-01 00:00:00

  • A new in vivo technique for determination of femoro-tibial and femoro-patellar 3D kinematics in total knee arthroplasty.

    abstract::Aim was to develop an in vivo technique which allows determination of femoro-tibial and of femoro-patellar 3D-kinematics in TKA simultaneously. The knees of 20 healthy volunteers and of eight patients with TKA (PCR, rotating platform) were investigated. Kinematics analysis was performed in an open MR-system at differe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.020

    authors: von Eisenhart-Rothe R,Vogl T,Englmeier KH,Graichen H

    更新日期:2007-01-01 00:00:00