Guinea pig maximization test, open epicutaneous test and chamber test in induction of delayed contact hypersensitivity.

Abstract:

:A comparison was made between the guinea pig maximization test (GPMT), open epicutaneous test (OET) and chamber test (CT), and the allergens were neomycin sulphate and propylene glycol (PG). The sensitization rate for neomycin in petrolatum was 35% in GPMT, 25% in OET and 25% in CT. The corresponding figures for neomycin in PG were 30% in GPMT, 45% in OET and 32% in CT. PG caused no hypersensitivity in 118 guinea pigs. The results suggested that as a hygroscopic, irritant and penetrating vehicle PG facilitates the induction of delayed contact allergy, especially in OET.

journal_name

Contact Dermatitis

journal_title

Contact dermatitis

authors

Kero M,Hannuksela M

doi

10.1111/j.1600-0536.1980.tb04960.x

subject

Has Abstract

pub_date

1980-08-01 00:00:00

pages

341-4

issue

5

eissn

0105-1873

issn

1600-0536

journal_volume

6

pub_type

杂志文章
  • Characteristics of chromium-allergic dermatitis patients prior to regulatory intervention for chromium in leather: a questionnaire study.

    abstract:BACKGROUND:Chromium-tanned leather articles currently constitute the most important cause of contact allergy to chromium in Denmark. A regulation on the content of hexavalent chromium in leather was adopted in November 2013 by the EU member states. OBJECTIVES:To characterize patients with chromium allergy and their di...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12291

    authors: Bregnbak D,Thyssen JP,Zachariae C,Johansen JD

    更新日期:2014-12-01 00:00:00

  • Occupational dermatoses at a film laboratory. Follow-up after modernization.

    abstract::The occurrence and causes of occupational dermatoses at a film laboratory following modernization was studied. In 1983 the film laboratory moved to new premises built to reduce exposure to hazardous chemicals. The study was carried out during 1983-1986 with repeated interviews and dermatological examinations of all em...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb04656.x

    authors: Lidén C

    更新日期:1989-03-01 00:00:00

  • Occupational allergic contact dermatitis from cinnamon including one case from airborne exposure.

    abstract:BACKGROUND:The bark of the cinnamon tree is used as a spice; its flavour is from an essential oil containing mainly cinnamal. OBJECTIVE:To report new cases of occupational allergic contact dermatitis (ACD) from cinnamon and a novel case of airborne cinnamon contact allergy. METHODS:We examined the patient material of...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2008.01486.x

    authors: Ackermann L,Aalto-Korte K,Jolanki R,Alanko K

    更新日期:2009-02-01 00:00:00

  • Kathon CG: cosmetic allergy and patch test sensitization.

    abstract::Three cases of contact allergy to Kathon CG, a preservative for cosmetics and toiletries containing, as active ingredients, 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one are presented. In two patients, Kathon CG was contained in a moisturizing cream, and the third was sensitized by a diagnos...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1985.tb01057.x

    authors: de Groot AC,Liem DH,Weyland JW

    更新日期:1985-02-01 00:00:00

  • Optimization of the mouse ear swelling test for in vivo and in vitro studies of weak contact sensitizers.

    abstract::Murine models for the assessment of the contact sensitizing properties of chemicals rely on mouse ear swelling tests (Mest), which are not sensitive enough to detect weak sensitizers. The aim of the present study was to develop in mice an adjuvant-free Mest appropriate for in vivo detection of any type of sensitizer (...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1994.tb00650.x

    authors: Garrigue JL,Nicolas JF,Fraginals R,Benezra C,Bour H,Schmitt D

    更新日期:1994-04-01 00:00:00

  • Allergic contact dermatitis in veterinary surgeons.

    abstract::Thirty-six of 37 veterinary surgeons with incapacitating dermatitis had allergic contact dermatitis, mainly from antibiotics such as spiramycin, Penethamate BP and tylosin. Eight were sensitive to rubber materials. Twenty of 36 had positive prick or scratch tests, mainly to animal hair. The atopic sensitivities were r...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1980.tb03885.x

    authors: Hjorth N,Roed-Petersen J

    更新日期:1980-01-01 00:00:00

  • Age distribution of the incidence of contact sensitivity to standard allergens.

    abstract::The incidence of contact sensitivity to standard allergens present in the daily environment, such as chromium ion, cobalt, nickel and formaldehyde, is found to decrease in the fourth decade. It strongly suggests the presence of some immunoregulation in human beings, because sensitivity to these allergens should be equ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1979.tb04910.x

    authors: Sugai T,Takagi T,Yamamoto S,Takahashi Y

    更新日期:1979-12-01 00:00:00

  • Patch tests with occupational contactants in nurses, doctors and dentists.

    abstract::In this study, 333 nurses, 92 dentists and 167 doctors were investigated. Most positive patch tests obtained were unrelated to occupation. Nurses were most often sensitized to penicillins and, of the disinfectants, formaldehyde was the commonest cause of occupational dermatitis. Among dentists, the most common occupat...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb03140.x

    authors: Rudzki E,Rebandel P,Grzywa Z

    更新日期:1989-04-01 00:00:00

  • Contact allergy due to colophony (VI). The sensitizing capacity of minor resin acids and 7 commercial modified-colophony products.

    abstract::3 minor resin acids and 7 commercial modified-colophony products of different origins were studied by experimental sensitization by means of a modified FCA method. All 3 resin acids were almost negative. The commercial products gave different results. While the maleic-modified product of Greek origin showed a strong s...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1990.tb03229.x

    authors: Hausen BM,Hessling C

    更新日期:1990-08-01 00:00:00

  • Contact dermatitis. A review.

    abstract::In recent years, there has been a dramatic rise in our understanding of contact dermatitis. This paper is a review of our knowledge of the mechanisms involved in contact dermatitis and related phenomena, the investigation of these events and the emergence of significant new allergens during the last 5 years. ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0536.1987.tb01382.x

    authors: Andersen KE,Benezra C,Burrows D,Camarasa J,Dooms-Goossens A,Ducombs G,Frosch P,Lachapelle JM,Lahti A,Menné T

    更新日期:1987-02-01 00:00:00

  • Allergic contact dermatitis caused by dexpanthenol-Probably a frequent allergen.

    abstract:BACKGROUND:Panthenol (synonym: dexpanthenol), the alcohol analogue of panthothenic acid, is frequently included in moisturizers, wound-healing agents, and other cosmetics, and has been shown to be responsible for allergic contact dermatitis (ACD). OBJECTIVES:To evaluate the frequency of ACD caused by dexpanthenol, and...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13054

    authors: Fernandes RA,Santiago L,Gouveia M,Gonçalo M

    更新日期:2018-11-01 00:00:00

  • Down-regulation of protein kinase C isoforms in irritant contact dermatitis.

    abstract::Protein kinase C (PKC) isoforms are important in cell signal transduction associated with regulation of cell proliferation and differentiation. In this study, alterations of PKC isoform levels in irritant patch test reactions were detected by Western immunoblots. 4 chemically and structurally different irritants, 4% a...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1998.tb05766.x

    authors: Li LF,Fiedler VC,Kumar R

    更新日期:1998-06-01 00:00:00

  • Hexavalent chromium in tattoo inks: Dermal exposure and systemic risk.

    abstract:BACKGROUND:The presence of hexavalent chromium (Cr[VI]), which is carcinogenic to humans and a dermal sensitizer, in tattoo inks may represent a serious health concern. The level of this impurity is limited to 0.2 mg/kg in tattoo inks by the European Resolution ResAP(2008)1. OBJECTIVES:To analyse 29 tattoo inks, produ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13051

    authors: Bocca B,Senofonte O,Petrucci F

    更新日期:2018-10-01 00:00:00

  • Do cool water or physiologic saline compresses enhance resolution of experimentally-induced irritant contact dermatitis?

    abstract::Acute irritant contact dermatitis (ICD) is frequently treated with cool water or saline compresses. While presumed effective, little quantitative evaluation documents the treatment's benefit. This study sought to determine the efficacy of both distilled water and physiologic saline compresses on experimentally-induced...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1034/j.1600-0536.2001.045003146.x

    authors: Levin CY,Maibach HI

    更新日期:2001-09-01 00:00:00

  • Coin exposure may cause allergic nickel dermatitis: a review.

    abstract::Nickel is used in coins because the metal has beneficial properties, including price, colour, weight, and corrosion resistance, and also because it is easy to stamp. It has often been claimed that the duration of skin contact with coins is too short to cause nickel release and dermatitis. However, it is well known by ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0536.2012.02127.x

    authors: Thyssen JP,Gawkrodger DJ,White IR,Julander A,Menné T,Lidén C

    更新日期:2013-01-01 00:00:00

  • Formaldehyde concentration in diagnostic patch testing: comparison of 1% with 2%.

    abstract::Exposure to formaldehyde is common from both consumer products and industry. The reliability of the patch test is essential for the diagnosis of formaldehyde allergy as it is difficult to suspect from the patient's history. The recommended formaldehyde patch test concentration has been reduced over the last decades fr...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1998.tb05630.x

    authors: Trattner A,Johansen JD,Menné T

    更新日期:1998-01-01 00:00:00

  • Ten-year trends in contact allergy to formaldehyde and formaldehyde-releasers.

    abstract:BACKGROUND:Preservatives such as formaldehyde and formaldehyde-releasers are common causes of contact allergy. OBJECTIVES:To examine trends in contact allergy to formaldehyde and formaldehyde-releasers in patch tested patients in Denmark over a 10-year period (2007-2016), and to investigate relevant sources of formald...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13052

    authors: Fasth IM,Ulrich NH,Johansen JD

    更新日期:2018-11-01 00:00:00

  • Purity of standardized textile dye allergens: a thin layer chromatography study.

    abstract::Twelve standard textile dyes were analyzed using thin layer chromatography and studied comparatively with dyes supposed to be chemically similar, having the same Colour Index number or Registration Code. According to the chromatograms, Disperse Yellow 3, Disperse Orange 1, Disperse Orange 3 and Disperse Orange 13 seem...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1986.tb05281.x

    authors: Foussereau J,Dallara JM

    更新日期:1986-05-01 00:00:00

  • Objective measurement of surfactant irritation by fiber optic spectroscopy.

    abstract::Erythema caused by occlusion of 3 concentrations of surfactant was quantified in vivo using a modified spectrophotometer. Standard chamber irritation test sites were evaluated objectively using the spectrophotometer and subjectively by trained observers. There was a good relationship between the instrumental and visua...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1988.tb02893.x

    authors: Crowe DM,Willard MS,Murahata RI,Aust LB,Gacula MC Jr

    更新日期:1988-09-01 00:00:00

  • Decreasing trends in methyldibromo glutaronitrile contact allergy--following regulatory intervention.

    abstract:BACKGROUND:The preservative methyldibromo glutaronitrile (MDBGN) has been banned, first from stay-on, and later from rinse-off cosmetics, in the EU countries because of increasing rates of contact allergy. OBJECTIVES:To evaluate the frequency of contact allergy to MDBGN among patients patch tested by the Danish Contac...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2008.01364.x

    authors: Johansen JD,Veien N,Laurberg G,Avnstorp C,Kaaber K,Andersen KE,Paulsen E,Sommerlund M,Thormann J,Nielsen NH,Vissing S,Kristensen O,Kristensen B,Agner T,Menné T

    更新日期:2008-07-01 00:00:00

  • Dermatitis in a rubber tyre factory.

    abstract::An outbreak of occupational dermatitis in a rubber tyre factory is reported. An unusual clinical picture was recognized. Patch tests revealed a high sensitization rate to the MBT derivative used: 2-(2'-4'dinitrophenylthio)benzothiazole. Since tests with MBT mix and dinitrophenol were negative; sensitization to a conta...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1987.tb02637.x

    authors: Zina AM,Bedello PG,Cane D,Bundino S,Benedetto A

    更新日期:1987-07-01 00:00:00

  • Contamination by nickel, copper and zinc during the handling of euro coins.

    abstract::The introduction of the euro has revived interest in the risk of nickel allergy due to the handling of coins. In the present work, the transfer of metallic contamination during the manipulation of coins is examined by means of leaching experiments and manipulation tests. It is shown that pre-existing metallic species ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1034/j.1600-0536.2003.00028.x

    authors: Fournier PG,Govers TR

    更新日期:2003-04-01 00:00:00

  • Eau de Javel and prevention of chromate allergy in France.

    abstract::"Eau de Javel" (liquid bleach) is a common cause of chromate contact allergy. A historical review explains the reasons for the addition of sodium dichromate after the First World War. The chromium content in different brands of eau de Javel has been determined by flameless atomic absorption spectrophotometry. The resu...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1980.tb03916.x

    authors: Lachapelle JM,Lauwerys R,Tennstedt D,Andanson J,Benezra C,Chabeau G,Ducombs G,Foussereau J,Lacroix M,Martin P

    更新日期:1980-01-01 00:00:00

  • Nickel dermatitis from cheap earrings.

    abstract::In 1988, 64% of our patients patch test positive to at least 1 allergen of the ICDRG standard series were nickel sensitive. In 70% of 300 patients evaluated, dermatitis started on the earlobes and was related to the regular wearing of cheap earrings. At the same time, 62% of 735 young schoolgirls were found to have de...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb03203.x

    authors: Santucci B,Ferrari PV,Cristaudo A,Cannistraci C,Picardo M

    更新日期:1989-10-01 00:00:00

  • Hyperkeratotic hand eczema: Eczema or not?

    abstract:BACKGROUND:Hyperkeratotic hand eczema (HHE) is a typical clinical hand eczema subtype with a largely unknown pathophysiology. OBJECTIVE:To investigate histopathology, expression of keratins (K), epidermal barrier proteins, and adhesion molecules in HHE. METHODS:Palmar skin biopsies (lesional and perilesional) were ob...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13572

    authors: Politiek K,Loman L,Pas HH,Diercks GFH,Lemmink HH,Jan SZ,van den Akker PC,Bolling MC,Schuttelaar MLA

    更新日期:2020-09-01 00:00:00

  • Contact Allergy to Polyhexamethylene Biguanide (Polyaminopropyl Biguanide).

    abstract:BACKGROUND:Polyaminopropyl biguanide (INCI name) and polyhexamethylene biguanide (PHMB) are polymeric biguanides. PHMB is a broad-spectrum antimicrobial substance used as a preservative in many products. Due to our limited knowledge on PHMB contact allergy frequency and the fact that cases of allergic contact dermatiti...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.13728

    authors: Sukakul T,Dahlin J,Pontén A,Antelmi A,Bruze M,Hamnerius N,Hauksson I,Isaksson M,Lejding T,Svedman C

    更新日期:2020-10-24 00:00:00

  • Contact dermatitis due to Nyloprint.

    abstract::The Nyloprint process is becoming more frequently used in Great Britain. We report a case of contact dermatitis in a 60-year-old man who was employed in the production of Nyloprint formes. The process is described in detail. Patch tests showed him to be very sensitive to an acrylamide derivative, which is used as a mo...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1976.tb03013.x

    authors: Pye RJ,Peachey RD

    更新日期:1976-06-01 00:00:00

  • Allergic patch test reactions caused by the rubber chemical cyclohexyl thiophthalimide.

    abstract::Rubber chemicals are among the most common occupational contact sensitizers. The most common rubber sensitizers are thiurams, thiazoles, carbamates and paraphenylenediamine derivatives. Here we present data on a less-well-known rubber chemical, N-(cyclohexylthio)phthalimide (CTP; CAS 17796-82-6). This chemical is curr...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1996.tb02106.x

    authors: Kanerva L,Estlander T,Jolanki R

    更新日期:1996-01-01 00:00:00

  • Detection of contact hypersensitivity to topical corticosteroids with hydrocortisone-17-butyrate.

    abstract::We showed earlier that most patients with contact dermatitis due to corticosteroids show cross-reactions when patch tested with hydrocortisone-17-butyrate (H-17-B). To test whether H-17-B could be used for detecting topical corticosteroid allergy, we screened patients undergoing routine patch testing with H-17-B. Pati...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb04729.x

    authors: Reitamo S,Lauerma AI,Förström L

    更新日期:1989-09-01 00:00:00

  • Allergy to lanolin.

    abstract::The purpose of the present study was to compare the frequency of lanolin allergy during two periods and to assess the adequacy of testing with one standard allergen. Among 1230 consecutive patients with eczema who were standard patch tested, 33 (2.7%), 21 females and 12 males, gave a positive reaction to wool alcohols...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1979.tb04824.x

    authors: Mortensen T

    更新日期:1979-05-01 00:00:00