Delayed dermal burns caused by dimethyl acetylenedicarboxylate.

Abstract:

:A chemical operator handling dimethyl acetylenedicarboxylate (DMAD) developed delayed and pain-free burns on one of his feet 2 days after a supposed spillage of DMAD. The injuries were confirmed to be associated with DMAD by chemical analysis of the operator's safety boot and patch tests. DMAD easily penetrates some protective clothing and dilute solutions can still be hazardous: the toxic effect is compounded by being delayed and painless. The lachrymatory irritant properties of undiluted DMAD are not adequate warning of its presence or spillage in quantities sufficient to cause significant skin damage.

journal_name

Contact Dermatitis

journal_title

Contact dermatitis

authors

Slovak AJ,Payne AR

doi

10.1111/j.1600-0536.1984.tb00166.x

subject

Has Abstract

pub_date

1984-07-01 00:00:00

pages

29-30

issue

1

eissn

0105-1873

issn

1600-0536

journal_volume

11

pub_type

杂志文章
  • Nickel allergy--prevalence in a population of Swedish youths from patch test and questionnaire data.

    abstract:BACKGROUND:The prevalence of body piercing and orthodontic treatment has increased during recent decades. Such changes in lifestyle may influence the occurrence of nickel allergy. OBJECTIVES:The aim of this study was to describe the prevalence of nickel allergy in a Swedish youth population. METHODS:In a cross-sectio...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2007.01257.x

    authors: Fors R,Persson M,Bergström E,Stenlund H,Stymne B,Stenberg B

    更新日期:2008-02-01 00:00:00

  • The influence of patch test size and design on the distribution of erythema induced by sodium lauryl sulfate.

    abstract::Patch testing is an invaluable tool for the experimental induction of acute irritant contact dermatitis (ICD), with a variety of chamber systems available for use. Ideally, the inflammatory reactions produced should be of uniform intensity across the test area, thereby facilitating grading of the response and tissue s...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1999.tb06158.x

    authors: Nicholson M,Willis CM

    更新日期:1999-11-01 00:00:00

  • Kathon CG: cosmetic allergy and patch test sensitization.

    abstract::Three cases of contact allergy to Kathon CG, a preservative for cosmetics and toiletries containing, as active ingredients, 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-4-isothiazolin-3-one are presented. In two patients, Kathon CG was contained in a moisturizing cream, and the third was sensitized by a diagnos...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1985.tb01057.x

    authors: de Groot AC,Liem DH,Weyland JW

    更新日期:1985-02-01 00:00:00

  • Ascertainment of hand dermatitis using a symptom-based questionnaire; applicability in an industrial population.

    abstract::In this study, the applicability of a symptom-based questionnaire on hand dermatitis was assessed in a population of rubber workers. The questionnaire was previously validated in a study among nurses. 224 subjects employed in 9 different companies completed a questionnaire on skin complaints. Subsequently, 202 workers...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1034/j.1600-0536.2000.042004202.x

    authors: Vermeulen R,Kromhout H,Bruynzeel DP,de Boer EM

    更新日期:2000-04-01 00:00:00

  • Contact sensitivity to flavourings and perfumes in atopic dermatitis.

    abstract::16 children with atopic dermatitis and 4 nonatopics were skin tested with flavourings and perfumes. Immediate reactions to balsam of Peru and fragrance-mix were found in 9 atopics, and none among nonatopics. An irritant is more probable than an immunologic mechanism. Allergen solutions should probably be assayed at a ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1992.tb05196.x

    authors: Abifadel R,Mortureux P,Perromat M,Ducombs G,Taieb A

    更新日期:1992-07-01 00:00:00

  • Nickel dermatitis from cheap earrings.

    abstract::In 1988, 64% of our patients patch test positive to at least 1 allergen of the ICDRG standard series were nickel sensitive. In 70% of 300 patients evaluated, dermatitis started on the earlobes and was related to the regular wearing of cheap earrings. At the same time, 62% of 735 young schoolgirls were found to have de...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb03203.x

    authors: Santucci B,Ferrari PV,Cristaudo A,Cannistraci C,Picardo M

    更新日期:1989-10-01 00:00:00

  • The critical review of methodologies and approaches to assess the inherent skin sensitization potential (skin allergies) of chemicals. Part I.

    abstract::To critically review currently available methods, or methods under development (in vivo, in vitro, in silico, etc.) used in the evaluation of skin sensitization potential and their applicability in the derivation of quantitative 'safety thresholds'. ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0536.2011.02004_2.x

    authors: Thyssen JP,Giménez-Arnau E,Lepoittevin JP,Menné T,Boman A,Schnuch A

    更新日期:2012-04-01 00:00:00

  • Nickel and cobalt release from metal alloys of tools--a current analysis in Germany.

    abstract:BACKGROUND:The former 'EU Nickel Directive' and, since 2009, the REACH Regulation (item 27 of Annex XVII) do not include all metallic objects. The nickel content of tools is not regulated by the REACH Regulation, even if they may come into in prolonged contact with the skin. Tools might be possible sources of nickel an...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12462

    authors: Kickinger-Lörsch A,Bruckner T,Mahler V

    更新日期:2015-11-01 00:00:00

  • Chronic irritant contact dermatitis: recovery time in man.

    abstract::Chronic irritant contact dermatitis (ICD) is a common skin disease, especially in the workplace, but determining the recovery time of chronic ICD is not easy. To measure the recovery time of chronic ICD, we examined the skin reactivity to a model surfactant, sodium lauryl sulfate (SLS), on previous chronic ICD and nor...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1034/j.1600-0536.2000.042005264.x

    authors: Choi JM,Lee JY,Cho BK

    更新日期:2000-05-01 00:00:00

  • A patch test closet.

    abstract::A way of adapting a treatment room for patch test purposes is described. ...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1975.tb05362.x

    authors: Epstein E

    更新日期:1975-06-01 00:00:00

  • Hypertrophic allergic contact dermatitis from hair dye.

    abstract::We report a case of hypertrophic allergic contact dermatitis probably due to p-phenylenediamine (PPDA) in a 26-year-old female, which developed at the sites of application of a black hair dye to the skin. Histological examination revealed an eczematous process. The lesions subsided completely except for leukoderma tha...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1994.tb01958.x

    authors: Santucci B,Cristaudo A,Cannistraci C,Amantea A,Picardo M

    更新日期:1994-09-01 00:00:00

  • Occupational allergic contact dermatitis from mercury.

    abstract::Occupational allergic contact dermatitis from metallic mercury is rare. Here we present the only 2 patients with relevant occupational mercury allergy detected at our clinic since 1974. The first patient was a dental nurse who became sensitized to metallic mercury from amalgam when handling uncured amalgam without pro...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1993.tb03319.x

    authors: Kanerva L,Komulainen M,Estlander T,Jolanki R

    更新日期:1993-01-01 00:00:00

  • Patch test sensitivity to Kathon CG.

    abstract::Among 1511 consecutive patients patch tested with Kathon CG at 100 ppm active ingredient, 13 (0.8%) gave a positive reaction. Use test with a lotion containing Kathon CG (8.6 ppm) revealed no reaction in 11 patients with a positive patch test. It is concluded that a positive patch test reaction to 100 ppm does not ini...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1986.tb01195.x

    authors: Hjorth N,Roed-Petersen J

    更新日期:1986-03-01 00:00:00

  • Contact sensitivity to emulsifiers.

    abstract::Common emulsifiers were tested in over 1,200 patients with eczema. Triethanolamine stearate tested at 5% in petrolatum caused irritant reactions in 9.5% of the patients. On the other hand, non-ionic emulsifying agents tested at 10-20% produced irritation in only a few cases. Allergic reactions were found in 2.1% of th...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1976.tb03027.x

    authors: Hannuksela M,Kousa M,Pirilä V

    更新日期:1976-08-01 00:00:00

  • Contact dermatitis to ethyl-cyanoacrylate-containing glue.

    abstract::3 patients with contact dermatitis to an ethyl cyanoacrylate glue are presented. Although reactions to cyanoacrylate glues are considered rare, more widespread use of these products by nail salons is likely to be associated with an increased incidence of positive reactions. All 3 of our patients came into contact with...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1987.tb02719.x

    authors: Belsito DV

    更新日期:1987-10-01 00:00:00

  • Hand eczema among Hong Kong nurses: a self-report questionnaire survey conducted in a regional hospital.

    abstract:BACKGROUND:Hand eczema is common in the nursing profession, and has been reported widely in various parts of the world. OBJECTIVES:The aim of this study was to determine the prevalence and severity of hand eczema among nurses working in a regional hospital in Hong Kong, as well as its psychosocial impact and any possi...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2011.01961.x

    authors: Luk NM,Lee HC,Luk CK,Cheung YY,Chang MC,Chao VK,Ng SC,Tang LS

    更新日期:2011-12-01 00:00:00

  • Contact allergy trends in Sweden - a retrospective comparison of patch test data from 1992, 2000, and 2009.

    abstract:BACKGROUND:Contact allergy prevalence rates change over time as a result of variations in allergen exposure. Data from patch test clinics are often used as markers for allergy trends. OBJECTIVES:The aim of the present retrospective study was to describe trends in rates of sensitization to allergens in the Swedish base...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12346

    authors: Fall S,Bruze M,Isaksson M,Lidén C,Matura M,Stenberg B,Lindberg M

    更新日期:2015-05-01 00:00:00

  • Allergic contact dermatitis caused by alkyl glucosides.

    abstract:BACKGROUND:Alkyl glucosides were not expected to have a sensitizing potential at the concentrations to be used in finished consumer products; however, several contact allergy cases have been published. OBJECTIVES:To report on the patients suffering from allergic contact dermatitis caused by alkyl glucosides observed i...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12154

    authors: Gijbels D,Timmermans A,Serrano P,Verreycken E,Goossens A

    更新日期:2014-03-01 00:00:00

  • Thiomersal allergy and vaccination reactions.

    abstract::Thiomersal is the preservative in all toxoid vaccines routinely administered to children in the UK, but exposure from other sources is uncommon. Delayed hypersensitivity to thiomersal was demonstrated in 1% of individuals attending the Contact Dermatitis Investigation Unit, and 50 of these patients with positive patch...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1988.tb02809.x

    authors: Cox NH,Forsyth A

    更新日期:1988-04-01 00:00:00

  • Skin disease and contact sensitivity in house painters using water-based paints, glues and putties.

    abstract::A dermatologic investigation of 202 construction painters included patch testing with the TRUE Test standard series and ingredients of water-based paints, glues and putties (painters' series). 32 painters had current eczema and 16 had a history of previous eczema. Of these, 16 and 9, respectively, had current and prev...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1995.tb00839.x

    authors: Fischer T,Bohlin S,Edling C,Rystedt I,Wieslander G

    更新日期:1995-01-01 00:00:00

  • Contact dermatitis to PPD rubber in Maleki shoes.

    abstract::The Persian cloth shoe (Maleki) which has been in use for more than 800 years has a strong cloth sole and a woven cotton upper. In the last 20 years, used car tires have become readily available in Iran and the soles of some shoes are now made from these. A man with the typical picture of rubber dermatitis on the sole...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1977.tb03605.x

    authors: Leppard BJ,Parhizgar B

    更新日期:1977-04-01 00:00:00

  • Reproducibility of patch tests: comparison of identical test allergens from different commercial sources.

    abstract::The reproducibility of patch tests is an important determinant of the clinical value of this diagnostic procedure. The aim of the present study was to delineate comparatively the efficiency and reproducibility of identical test reagents from 2 different commercial sources. Purchased in duplicate from brial and Boots-H...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.0105-1873.2004.00289.x

    authors: Schiessl C,Wolber C,Strohal R

    更新日期:2004-01-01 00:00:00

  • Frictional hyperkeratotic hand dermatitis responding to Grenz ray therapy.

    abstract::Frictional hyperkeratotic hand dermatitis (FHHD) is an unusual form of chronic eczema relating to repeated frictional trauma. This form of hand eczema is often occupationally related and recalcitrant to therapy. We describe the case of FHHD in a 48-year-old dermatologic surgeon. The eruption was resistant to all topic...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2007.01152.x

    authors: Walling HW,Swick BL,Storrs FJ,Boddicker ME

    更新日期:2008-01-01 00:00:00

  • Occupational dermatoses at a film laboratory. Follow-up after modernization.

    abstract::The occurrence and causes of occupational dermatoses at a film laboratory following modernization was studied. In 1983 the film laboratory moved to new premises built to reduce exposure to hazardous chemicals. The study was carried out during 1983-1986 with repeated interviews and dermatological examinations of all em...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb04656.x

    authors: Lidén C

    更新日期:1989-03-01 00:00:00

  • Effect of test techniques of perfusion of neomycin sulfate patch tests. A comparative study with visual assessments.

    abstract::Effects of test techniques on neomycin patch test results have not been thoroughly investigated. This study focuses on effects of dose and application time of neomycin sulfate patch tests on test results. The effects are assessed both visually and by perfusion. 16 subjects positive to neomycin are retested with neomyc...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1034/j.1600-0536.2000.043005283.x

    authors: Bjarnason B,Flosadóttir E

    更新日期:2000-11-01 00:00:00

  • Occupational contact dermatitis caused by 1,3-benzenedimethanamine, N-(2-phenylethyl) derivatives in hardeners for epoxy paints and coatings.

    abstract:BACKGROUND:Amines in epoxy hardeners are significant causes of occupational allergic contact dermatitis among workers who use epoxy resin systems. OBJECTIVES:To describe a novel group of contact allergens: N-(2-phenylethyl) derivatives of the reactive amine 1,3-benzenedimethanamine (1,3-BDMA). METHODS:We describe the...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/cod.12652

    authors: Pesonen M,Kuuliala O,Suomela S,Aalto-Korte K

    更新日期:2016-12-01 00:00:00

  • Occurrence and prognosis of hand eczema in the car industry: results from the PACO follow-up study (PACO II).

    abstract:BACKGROUND:Only a few epidemiological studies on hand eczema (HE) in the metalworking industry have been conducted, and no study has attempted a long-term follow-up. OBJECTIVES:In the Prospective Audi Cohort (PACO) II follow-up study, we aimed to estimate burden and prognosis of HE in a car industry setting (follow-up...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.2008.01329.x

    authors: Apfelbacher CJ,Radulescu M,Diepgen TL,Funke U

    更新日期:2008-06-01 00:00:00

  • Use tests: ROAT (repeated open application test)/PUT (provocative use test): an overview.

    abstract::As one step in defining the clinical relevance of exposure to an allergen identified with patch testing, use tests (provocative use test (PUT), and repeated open application test (ROAT)) have been used. In 1/2 of the cases of seemingly reliable patch tests, use tests are negative, suggesting that the patient's biologi...

    journal_title:Contact dermatitis

    pub_type: 杂志文章,评审

    doi:10.1034/j.1600-0536.2000.043001001.x

    authors: Nakada T,Hostynek JJ,Maibach HI

    更新日期:2000-07-01 00:00:00

  • Topical cyclosporine: effects on allergic contact dermatitis in guinea pigs.

    abstract::Cyclosporine (CSA) is an effective immunosuppressive agent and is used in tissue transplantation. The present investigation was undertaken to determine the effect of topical delivery of CSA on allergic contact dermatitis in guinea pigs. Topical 15% CSA in an azone (1-dodecylazacycloheptan-2-one)-containing vehicle blo...

    journal_title:Contact dermatitis

    pub_type: 杂志文章

    doi:10.1111/j.1600-0536.1989.tb03088.x

    authors: Biren CA,Barr RJ,Ganderup GS,Lemus LL,McCullough JL

    更新日期:1989-01-01 00:00:00

  • The influence of patch tests with clobetasol propionate on adjacent patch test reactions.

    abstract::Contact allergy to corticosteroids now seems frequent among patients being patch tested. As corticosteroids are intrinsically anti-inflammatory, we investigated whether patch tests with a potent corticosteroid might suppress simultaneous adjacent patch test reactions to another allergen. Nickel-sensitive subjects were...

    journal_title:Contact dermatitis

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1600-0536.1995.tb00809.x

    authors: Bruze M,Isaksson M,Dooms-Goossens A

    更新日期:1995-03-01 00:00:00