Evaluation of the first fully automated immunoassay method for the measurement of stimulating TSH receptor autoantibodies in Graves' disease.

Abstract:

BACKGROUND:Thyroid stimulating hormone (TSH) receptor autoantibodies (TRAb) are pathogenetic and diagnostic hallmarks of Graves' disease (GD). Three varieties of TRAb have been described: stimulating (S-TRAb), blocking (B-TRAb), and apoptotic (A-TRAb) autoantibodies. Very recently, the first immunoassay method (Immulite TSI assay, Siemens Healthcare Diagnostics) declared to measure serum S-TRAb concentration, has been made available in an automated commercial platform. The aim of the study was to evaluate the ability of this new test to identify patients suffering from GD, in comparison with two current IMA methods for total TSH receptor autoantibodies (T-TRAb) measurement. METHODS:Sera of 383 subjects [72 patients with untreated GD, 55 patients with autoimmune thyroiditis (AIT), 36 patients with multinodular non-toxic goiter, 100 patients with other non-thyroid autoimmune diseases (NTAD) and 120 healthy subjects (HS)] were evaluated. RESULTS:The threshold obtained by receiver operating characteristic (ROC) analysis was 0.54 IU/L, very similar to that proposed by the manufacturer (0.55 IU/L). Thyroid-stimulating immunoglobulins (TSI) were positive in all GD patients and negative in all but three controls (clinical sensitivity and specificity of 100% and 98.7%, respectively). Passing and Bablok regression analysis and Bland-Altman plot showed an acceptable agreement between TSI Immulite assay and other two immunoassay methods (Cobas/Elecsys, Roche and TRAK RIA, BRAHMS Thermo Scientific). CONCLUSIONS:The diagnostic performance of fully automated Immulite TSI assay in GD patients is at least comparable to that of current TRAb immunoassays (IMAs) suggesting the possibility of including such assay in rapid and cost-saving diagnostic and monitoring algorithms. However, our results do not provide full evidence that this assay is specific for S-TRAb only, and future studies comparing Immulite TSI assay to stimulating activity are required.

journal_name

Clin Chem Lab Med

authors

Tozzoli R,D'Aurizio F,Villalta D,Giovanella L

doi

10.1515/cclm-2016-0197

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

58-64

issue

1

eissn

1434-6621

issn

1437-4331

pii

/j/cclm.ahead-of-print/cclm-2016-0197/cclm-2016-01

journal_volume

55

pub_type

杂志文章
  • Multicentre evaluation of the Tosoh HbA1c G8 analyser.

    abstract:BACKGROUND:We report a Dutch-Belgian multicentre evaluation of the Tosoh HLC-723G8 glycohaemoglobin analyser, an ion-exchange HPLC instrument for the separation and quantification of haemoglobin A1c (HbA1c) in whole blood. METHODS:We evaluated the analytical performances of the Tosoh G8 analyser and compared the resul...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/CCLM.2010.062

    authors: Chapelle JP,Teixeira J,Maisin D,Assink H,Barla G,Stroobants AK,Delzenne B,van den Eshof W

    更新日期:2010-03-01 00:00:00

  • The serum uromodulin level is associated with kidney function.

    abstract:BACKGROUND:In chronic kidney diseases of various etiologies, the urinary excretion of uromodulin is usually decreased in parallel with the glomerular filtration rate. This study aimed to investigate whether serum uromodulin is associated with kidney function. METHODS:Within the framework of the Seniorlabor study, a su...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0505

    authors: Risch L,Lhotta K,Meier D,Medina-Escobar P,Nydegger UE,Risch M

    更新日期:2014-12-01 00:00:00

  • Meta-analysis: diagnostic accuracy of anti-cyclic citrullinated peptide 2 antibody and anti-cyclic citrullinated peptide 3 antibody in rheumatoid arthritis.

    abstract::The aim of this work was to assess the diagnostic value of anti-CCP-3 and anti-CCP-2 for the diagnosis of rheumatoid arthritis (RA) and determine whether anti-CCP-3 more accurately identifies patients with rheumatoid arthritis than anti-CCP-2. PubMed and CNKI databases were searched for studies published in English an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,meta分析

    doi:10.1515/cclm-2013-0798

    authors: Zhang WC,Wu H,Chen WX

    更新日期:2014-06-01 00:00:00

  • Comparative measurement of N-terminal pro-brain natriuretic peptide and brain natriuretic peptide in ambulatory patients with heart failure.

    abstract::It is not clear whether brain natriuretic peptide (BNP) or N-terminal proBNP (NT-proBNP) is superior as a diagnostic and prognostic indicator in cardiac diseases. Here, we compare the clinical correlations of both peptides in a population of 92 ambulatory patients with heart failure, using a well-established immunorad...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2002.130

    authors: Masson S,Vago T,Baldi G,Salio M,De Angelis N,Nicolis E,Maggioni AP,Latini R,Norbiato G,Bevilacqua M

    更新日期:2002-08-01 00:00:00

  • Anemia and iron biomarkers in patients with early breast cancer. Diagnostic value of hepcidin and soluble transferrin receptor quantification.

    abstract:BACKGROUND:Anemia, a frequent and deleterious condition in patients with cancer, is mainly caused by chemotherapy toxicity, iron deficiency, or inflammation. We evaluated the baseline iron metabolism biomarkers and their association with anemia occurrence during chemotherapy in patients with early breast cancer (EBC). ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2013-0031

    authors: Durigova A,Lamy PJ,Thezenas S,Pouderoux S,Montels F,Romieu G,Gutowski M,Jacot W

    更新日期:2013-09-01 00:00:00

  • Anti-N-homocysteinylated protein autoantibodies and cardiovascular disease.

    abstract::Metabolic conversion of homocysteine (Hcy) to a chemically reactive metabolite, Hcy-thiolactone, catalyzed by methionyl-tRNA synthetase is the first step in a pathway that is suggested to contribute to Hcy toxicity in humans. The accumulation of Hcy-thiolactone is detrimental because of its intrinsic ability to modify...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2005.177

    authors: Jakubowski H

    更新日期:2005-01-01 00:00:00

  • External quality assessment of bone metabolism marker assays. initial experiences in a UK NEQAS programme.

    abstract::This paper reports on a pilot external quality assessment scheme for bone markers including serum bone alkaline phosphatase and procollagen 1-carboxy terminal propeptide together with urine deoxypyridinoline, N- and C-telopeptides. The data shows poor numerical agreement between commercial assays, between-laboratory i...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2000.168

    authors: Whitham KM,Milford-Ward A

    更新日期:2000-11-01 00:00:00

  • Evaluation of errors in a clinical laboratory: a one-year experience.

    abstract:BACKGROUND:Efficient laboratory service is the cornerstone of modern health care systems. Scientific innovations have contributed to substantial improvements in the field of laboratory science, but errors still prevail. These errors are classified as preanalytical, analytical and postanalytical, depending upon the time...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.006

    authors: Goswami B,Singh B,Chawla R,Mallika V

    更新日期:2010-01-01 00:00:00

  • Copeptin decrease from admission to discharge has favorable prognostic value for 90-day events in patients admitted with dyspnea.

    abstract:BACKGROUND:With patients referred to emergency departments (EDs) for acute dyspnea, emergency physicians should consider all possible diagnoses and assess patients' risk stratification. Copeptin has been shown to have prognostic power for subsequent events, such as death and rehospitalization in patients admitted for d...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0207

    authors: Vetrone F,Santarelli S,Russo V,Lalle I,De Berardinis B,Magrini L,Di Stasio E,Salerno G,Cardelli P,Piccoli A,Codognotto M,Mion MM,Plebani M,Vettore G,Castello LM,Avanzi GC,Di Somma S

    更新日期:2014-10-01 00:00:00

  • Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography.

    abstract:BACKGROUND:Haemoglobin (Hb) variants are well-known factors interfering with accurate HbA1c testing. This report describes two novel Hb variants leading to inappropriate quantification of HbA1c by ion-exchange chromatography. METHODS:Glycated forms of novel Hb variants were recognised in the blood of two patients with...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2015-0054

    authors: Bots M,Stroobants AK,Delzenne B,Soeters MR,de Vries JE,Weykamp CW,Norg RJ,Veldthuis M,Zwieten Rv

    更新日期:2015-08-01 00:00:00

  • Comparative evaluation of capillary zone electrophoresis and HPLC in the determination of carbohydrate-deficient transferrin.

    abstract:BACKGROUND:Transferrin (Tf) glycoform lacking one or two complete or incomplete glycan chains (i.e., asialo-monosialo- and disialo-Tf) typically appear in blood after chronic alcohol consumption, though recently it was reported that monosialo-Tf is associated with trisialo-Tf but not with alcohol consumption. These gly...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.630

    authors: Daves M,Cemin R,Floreani M,Pusceddu I,Cosio G,Lippi G

    更新日期:2011-10-01 00:00:00

  • Multicenter evaluation of the analytical and clinical performance of the Elecsys S100 immunoassay in patients with malignant melanoma.

    abstract::The aim of this multicenter study was to evaluate the technical and clinical performance of the Elecsys S100 electrochemiluminescence immunoassay and to assess its utility as a tumor marker in patients with malignant melanoma. Imprecision studies yielded within-run coefficients of variation (CVs) of 0.7-2.0% and betwe...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,多中心研究

    doi:10.1515/CCLM.2005.097

    authors: Alber B,Hein R,Garbe C,Caroli U,Luppa PB

    更新日期:2005-01-01 00:00:00

  • Impact of standardized calibration on the inter-assay variation of 14 automated assays for the measurement of creatinine in human serum.

    abstract:PURPOSE:The aim of our study was to measure the inter-assay variation and accuracy of serum creatinine assays and to assess the effect of standardized calibration procedures on this variability. METHODS:We analyzed 30 human sera and three reference materials, using 17 creatinine assays (12 colorimetric, 4 enzymatic an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2005.213

    authors: Séronie-Vivien S,Galteau MM,Carlier MC,Hadj-Aissa A,Hanser AM,Hym B,Marchal A,Michotey O,Pouteil-Noble C,Sternberg M,Perret-Liaudet A,Creatinine Working Group of the Société Française de Biologie Clinique.

    更新日期:2005-01-01 00:00:00

  • Homocysteine and asymmetric dimethylarginine (ADMA): biochemically linked but differently related to vascular disease in chronic kidney disease.

    abstract::Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide synthase, is formed by methylation of arginine residues in proteins and released after proteolysis. In this reaction, S-adenosylmethionine is methyldonor and S-adenosylhomocysteine the demethylated product. ADMA and homocysteine are thus bioch...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2007.340

    authors: van Guldener C,Nanayakkara PW,Stehouwer CD

    更新日期:2007-01-01 00:00:00

  • Immunohistochemistry in the evaluation of spermatogenesis and Sertoli cell's maturation status.

    abstract::An increasing incidence of male infertility has been noted over the past few decades. This adds urgency to the need to develop immunohistochemical markers for better evaluation of testicular biopsies. We provide evidence that a histopathological evaluation performed according to morphological criteria and assisted by ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/CCLM.2002.036

    authors: Bar-Shira Maymon B,Yavetz H,Schreiber L,Paz G

    更新日期:2002-03-01 00:00:00

  • The high-sensitivity cardiac troponin T assay is superior to its previous assay generation for prediction of 90-day clinical outcome in ischemic stroke.

    abstract:BACKGROUND:Cardiac troponin T (cTnT) has been reported to be a predictor of stroke outcome. We hypothesized that the high-sensitivity cTnT (hs-cTnT) assay is superior to its previous assay generation for stroke outcome prediction. METHODS:cTnT was measured on emergency department admission in 60 consecutive patients (...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2012-0176

    authors: Furtner M,Ploner T,Hammerer-Lercher A,Pechlaner R,Mair J

    更新日期:2012-11-01 00:00:00

  • Annual rhythmic and non-rhythmic biological variation of magnesium and ionized calcium concentrations.

    abstract::The annual inter- and intra-individual biological variation, including the circannual rhythmic variation, of the serum concentrations of magnesium and ionized calcium has been investigated in a group of 51 apparently healthy volunteers. Venous blood specimens were collected on intervals of once a month within a one-ye...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2001.011

    authors: Valero-Politi J,Ginard-Salvá M,González-Alba JM

    更新日期:2001-01-01 00:00:00

  • Particle counting immunoassay for urinary cotinine. Comparison with chromatography, enzyme-linked immunoassay and fluorescence polarization immunoassay.

    abstract::Urinary cotinine was measured according to its inhibitory activity on the agglutination of cotinine-coated latex particles by anti-cotinine antibodies, the agglutination being measured by optical counting of the remaining non-agglutinated particles (particle counting, PaC). The detection limit was 0.03 microgram/ml an...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1999.112

    authors: Galanti LM,Dell'Omo J,Vanbeckbergen D,Dubois P,Masson PL,Cambiaso CL

    更新日期:1999-07-01 00:00:00

  • Study of apo(a) length polymorphism and lipoprotein(a) concentrations in subjects with single or double apo(a) isoforms.

    abstract::Cardiovascular risk is associated with high lipoprotein(a) (Lp(a)) concentrations and low molecular weight apolipoprotein(a) (apo(a)) isoforms. We studied the relationship between these two biological parameters, particularly in subjects expressing two apo(a) isoforms. Plasma Lp(a) was measured by immunonephelometry i...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2003.096

    authors: Alaoui M,Merle C,Garnotel R,Jolly D,Durlach V,Gillery P

    更新日期:2003-05-01 00:00:00

  • Elevated group II phospholipase A2 mass concentration in serum and colonic mucosa in Crohn's disease.

    abstract::Group II phospholipase A2 has been proposed to play an important role in the pathophysiology of inflammatory bowel diseases. This enzyme has also been linked to host defence mechanisms against bacteria. The current study aimed at measuring the mass concentrations of group II phospholipase A2 in serum and colonic mucos...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1998.133

    authors: Haapamäki MM,Grönroos JM,Nurmi H,Söderlund K,Peuravuori H,Alanen K,Nevalainen TJ

    更新日期:1998-10-01 00:00:00

  • The diagnostic accuracy of biomarkers for diagnosis of primary biliary cholangitis (PBC) in anti-mitochondrial antibody (AMA)-negative PBC patients: a review of literature.

    abstract::Primary biliary cholangitis (PBC), also known as primary biliary cirrhosis, is an autoimmune disease of the liver characterized by anti-mitochondrial antibodies (AMA) in 90%-95% of patients. The aim of this study was to evaluate the diagnostic value of several serum biomarkers in patients with PBC but negative for AMA...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2017-0249

    authors: de Liso F,Matinato C,Ronchi M,Maiavacca R

    更新日期:2017-11-27 00:00:00

  • Development and validation of a high performance liquid chromatography method to determine linezolid concentrations in pig pulmonary tissue.

    abstract:BACKGROUND:Linezolid is the first synthetic compound of a new group of antimicrobials, the oxazolidinones, which inhibit protein synthesis. It shows a broad spectrum of activity against Gram positive organisms. With respect to its pharmacokinetics, linezolid shows a relatively high volume of distribution and good penet...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2010.078

    authors: Guerrero L,Martínez-Olondris P,Rigol M,Esperatti M,Esquinas C,Luque N,Piñer R,Torres A,Soy D

    更新日期:2010-03-01 00:00:00

  • Diagnosis of sphingolipidoses: a new simultaneous measurement of lysosphingolipids by LC-MS/MS.

    abstract:BACKGROUND:Lysosphingolipids (LysoSLs) are derivatives of sphingolipids which have lost the amide-linked acyl chain. More recently, LysoSLs have been identified as storage compounds in several sphingolipidoses, including Gaucher, Fabry and Niemann-Pick diseases. To date, different methods have been developed to measure...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2016-0340

    authors: Polo G,Burlina AP,Kolamunnage TB,Zampieri M,Dionisi-Vici C,Strisciuglio P,Zaninotto M,Plebani M,Burlina AB

    更新日期:2017-03-01 00:00:00

  • Diagnosis biomarkers in acute intestinal ischemic injury: so close, yet so far.

    abstract::Acute intestinal ischemic injury (i3) is a life-threatening condition with disastrous prognosis, which is currently difficult to diagnose at the early stages of the disease; a rapid diagnosis is mandatory to avoid irreversible ischemia, extensive bowel resection, sepsis and death. The overlapping protein expression of...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2017-0291

    authors: Peoc'h K,Nuzzo A,Guedj K,Paugam C,Corcos O

    更新日期:2018-02-23 00:00:00

  • Potentiometric measurement of urinary iodine concentration in patients with thyroid diseases with and without previous exposure to non-radioactive iodine.

    abstract:BACKGROUND:Extensive application of measurement of urinary iodine concentration (UIC) in several benign and malignant thyroid diseases could profit by the availability of rapid and inexpensive measuring techniques. Aim of this study was to apply a simple and inexpensive commercially available potentiometric method for ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2015-0117

    authors: Giovacchini G,Giovanella L,Haldemann A,Staub U,Füchsel FG,Koch P

    更新日期:2015-10-01 00:00:00

  • Influence of ABO type on global coagulation assay results: effect of coagulation factor VIII.

    abstract:BACKGROUND:As ABO blood type influences the plasma level of coagulation factor VIII (FVIII), it likely also affects activated partial thromboplastin time (aPTT) and thrombin generation assay (TGA) values. Here, we aimed to investigate the effect of ABO type on the normal values of three global coagulation assays: proth...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/cclm-2014-0909

    authors: Choi Q,Kim JE,Kim SY,Han KS,Kim HK

    更新日期:2015-08-01 00:00:00

  • Customer satisfaction survey to improve the European cystic fibrosis external quality assessment scheme.

    abstract:BACKGROUND:The Cystic Fibrosis European Network, coordinated from within the Katholieke Universiteit Leuven, is the provider of the European cystic fibrosis external quality assessment (EQA) scheme. The network aimed to seek feedback from laboratories that participated in the cystic fibrosis scheme in order to improve ...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2011.215

    authors: Berwouts S,Dequeker E

    更新日期:2011-08-01 00:00:00

  • Cerebrospinal fluid tau and Abeta42 concentrations in healthy subjects: delineation of reference intervals and their limitations.

    abstract::Many limitations and conflicting results have cast serious doubts on the validity of cerebrospinal fluid tau and Abeta42 levels for the biological diagnosis of Alzheimer's disease, particularly extreme variations of the reference limits found by unrelated groups as a consequence of different reference populations used...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.2004.071

    authors: Burkhard PR,Fournier R,Mermillod B,Krause KH,Bouras C,Irminger I

    更新日期:2004-04-01 00:00:00

  • Evaluation of an automated immunoassay method for cytokine measurement using the Immulite Immunoassay system.

    abstract::Cytokines are key mediators in cell regulation and communication. The concentration of these proteins can rapidly and importantly increase during severe clinical situations. However, current techniques are not adapted to stat measurement, thus making their clinical use limited. In this context, the commercialization o...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章

    doi:10.1515/CCLM.1999.092

    authors: Berthier F,Lambert C,Genin C,Bienvenu J

    更新日期:1999-05-01 00:00:00

  • Inflammatory bowel diseases: from pathogenesis to laboratory testing.

    abstract::Inflammatory bowel diseases (IBDs), which comprise the two major clinical subtypes, Crohn's disease and ulcerative colitis, incur high morbidity and potential mortality. The present study reviews data on the pathogenesis and diagnosis of IBDs. The pathogenesis depends on complex interactions between susceptibility gen...

    journal_title:Clinical chemistry and laboratory medicine

    pub_type: 杂志文章,评审

    doi:10.1515/cclm-2013-0588

    authors: Basso D,Zambon CF,Plebani M

    更新日期:2014-04-01 00:00:00