Mechanical characterization and validation of poly (methyl methacrylate)/multi walled carbon nanotube composite for the polycentric knee joint.

Abstract:

:Trans femoral amputation is one of the most uncomfortable surgeries in patient׳s life, where the prosthesis consisting of a socket, knee joint, pylon and foot is used to do the walking activities. The artificial prosthetic knee joint imitates the functions of human knee to achieve the flexion-extension for the above knee amputee. The objective of present work is to develop a light weight composite material for the knee joint to reduce the metabolic cost of an amputee. Hence, an attempt was made to study the mechanical properties of multi walled carbon nanotubes (MWCNT) reinforced Poly (methyl methacrylate) (PMMA) prepared through melt mixing technique and optimize the concentration of reinforcement. The PMMA nanocomposites were prepared by reinforcing 0, 0.1, 0.2, 0.25, 0.3 and 0.4 wt% of MWCNT using injection moulding machine via twin screw extruder. It is observed that the tensile and flexural strength of PMMA, which were studied as per ASTM D638 and D790, respectively, were increased by 32.9% and 26.3% till 0.25 wt% reinforcement of MWCNT. The experimental results of strength and modulus were compared with theoretical prediction, where a good correlation was noted. It is concluded that the mechanical properties of PMMA were found to be increased to maximum at 0.25 wt% reinforcement of MWCNT, where the Pukanszky model and modified Halpin-Tsai model are suggested to predict the strength and modulus, respectively, of the PMMA/MWCNT composite, which can be opted as a suitable materiel for the development of polycentric knee joint.

authors

Arun S,Kanagaraj S

doi

10.1016/j.jmbbm.2015.06.002

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

33-42

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(15)00194-0

journal_volume

50

pub_type

杂志文章
  • Hydrogels with differential and patterned mechanics to study stiffness-mediated myofibroblastic differentiation of hepatic stellate cells.

    abstract::The differentiation of hepatic stellate cells (HSCs) into myofibroblasts is a key event in liver fibrosis. Due to the local stiffening of the extracellular matrix (ECM) during fibrosis, it is of great interest to develop mimics that can be used to investigate the cellular response to changes in mechanics. Here, we use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.11.008

    authors: Guvendiren M,Perepelyuk M,Wells RG,Burdick JA

    更新日期:2014-10-01 00:00:00

  • Reduction of load-bearing capacity of all-ceramic crowns due to cement aging.

    abstract::The purpose of this study was to investigate how water aging of the resin cement influences the stress distribution in all-ceramic crowns and if there is an increase in the propensity for crown failure. The failure of all-ceramic crowns attributed to cement degradation was explored using a combination of experimental ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.003

    authors: Lu C,Wang R,Mao S,Arola D,Zhang D

    更新日期:2013-01-01 00:00:00

  • Different models for simulation of mechanical behaviour of porous materials.

    abstract::Commercially pure Titanium (cpTi) and its alloys are the most successful metallic biomaterials for bone replacement, due to its excellent biomechanical and biofunctional balance. However, these materials have higher elastic modulus when compared with bone, leading to the stress-shielding phenomenon and promoting bone ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.026

    authors: Muñoz S,Castillo SM,Torres Y

    更新日期:2018-04-01 00:00:00

  • Heterogeneous modeling based prosthesis design with porosity and material variation.

    abstract::The work proposes the development of heterogeneous bio-implants with the aim to minimize stress shielding effect and enhance bone ingrowth. Stress shielding in the implant can be minimized by reducing the overall stiffness of the implant, which is achieved here by varying the material based on stress distribution acro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.029

    authors: Singh SK,Tandon P

    更新日期:2018-11-01 00:00:00

  • An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch.

    abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.003

    authors: Fallahnezhad K,Oskouei RH,Badnava H,Taylor M

    更新日期:2017-11-01 00:00:00

  • Interfacial bonding between mineral platelets in bone and its effect on mechanical properties of bone.

    abstract::Bone is a composite material consisting principally of apatite mineral, collagen fibrils, non-collagenous proteins, and other organic species. Recent electron microscopy studies have shown that the mineral in bone occurs as stacks of thin polycrystalline sheets ("mineral lamellae," MLs) which surround and lie between ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104132

    authors: Pang S,Schwarcz HP,Jasiuk I

    更新日期:2021-01-01 00:00:00

  • On multiscale boundary conditions in the computational homogenization of an RVE of tendon fascicles.

    abstract::Present study provides a numerical investigation on multiscale boundary conditions in the computational homogenization of a representative volume element (RVE) of tendon fascicles. A three-dimensional hexagonal-helicoidal finite element RVE composed of two material phases (collagen fibers and cells) and three finite s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.003

    authors: Carniel TA,Klahr B,Fancello EA

    更新日期:2019-03-01 00:00:00

  • Dynamic nanomechanical properties of novel Si-rich intermetallic coatings growth on a medical 316 LVM steel by hot dipping in a hypereutectic Al-25Si alloy.

    abstract::This aim of this study is to determine the elastoplastic properties of Ni-free Al3FeSi2 intermetallic coatings grown on medical stainless steel under different experimental conditions. Elastoplastic properties are defined by the plasticity index (PI), which correlates the hardness and the Young's modulus. Special emph...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.018

    authors: Frutos E,González-Carrasco JL

    更新日期:2015-06-01 00:00:00

  • Mechanical properties and adaptations of some less familiar bony tissues.

    abstract::This review attempts to show the bone community that there are many ways of being a 'bone', and that the range of mechanical properties of bone material is much greater than is conventionally thought to be the case. However the structure-function relationships have in many cases hardly moved beyond mere assertion. The...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2010.03.002

    authors: Currey JD

    更新日期:2010-07-01 00:00:00

  • Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading.

    abstract::This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.005

    authors: Ozcan M,Melo RM,Souza RO,Machado JP,Felipe Valandro L,Botttino MA

    更新日期:2013-04-01 00:00:00

  • Frequency-modulated atomic force microscopy localises viscoelastic remodelling in the ageing sheep aorta.

    abstract::Age-related aortic stiffening is associated with cardiovascular diseases such as heart failure. The mechanical functions of the main structural components of the aorta, such as collagen and elastin, are determined in part by their organisation at the micrometer length scale. With age and disease both components underg...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.07.018

    authors: Akhtar R,Graham HK,Derby B,Sherratt MJ,Trafford AW,Chadwick RS,Gavara N

    更新日期:2016-12-01 00:00:00

  • Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

    abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.034

    authors: Lee JT,Cho SA

    更新日期:2016-08-01 00:00:00

  • Experimental validation of finite element model for proximal composite femur using optical measurements.

    abstract::Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.02.006

    authors: Grassi L,Väänänen SP,Amin Yavari S,Weinans H,Jurvelin JS,Zadpoor AA,Isaksson H

    更新日期:2013-05-01 00:00:00

  • Administration of PTH and ibandronate increases ovariectomized rat compact bone viscoelasticity.

    abstract::In this study, the bone mineral density (BMD), geometry, macroscopic viscoelastic properties and mechanical strength in five different groups of Sprague-Dawley rats (sham operated, ovariectomized with vehicle, parathyroid hormone and/or ibandronate administration) were examined by peripheral quantitative computed tomo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.009

    authors: Yang X,Teoh SH,DasDe S,Lee T

    更新日期:2013-06-01 00:00:00

  • Cytocompatibility, mechanical and dissolution properties of high strength boron and iron oxide phosphate glass fibre reinforced bioresorbable composites.

    abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.011

    authors: Sharmin N,Hasan MS,Parsons AJ,Rudd CD,Ahmed I

    更新日期:2016-06-01 00:00:00

  • Designing vascular supportive albumen-rich composite bioink for organ 3D printing.

    abstract::Bioink plays a major role in 3D printing of tissues and organs. Alginate is a widely used component for bioinks but its cellular responses are limited, which limits its clinical translation. In this study, we demonstrate the printability and cellular compatibility of composite bioink consists of sodium alginate (NaAlg...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103642

    authors: Liu S,Zhang H,Hu Q,Shen Z,Rana D,Ramalingam M

    更新日期:2020-04-01 00:00:00

  • Thickness optimization of auricular silicone scaffold based on finite element analysis.

    abstract::An optimized thickness of a transplantable auricular silicone scaffold was researched. The original image data were acquired from CT scans, and reverse modeling technology was used to build a digital 3D model of an auricle. The transplant process was simulated in ANSYS Workbench by finite element analysis (FEA), solid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.032

    authors: Jiang T,Shang J,Tang L,Wang Z

    更新日期:2016-01-01 00:00:00

  • In vivo assessment of material properties of muscles and connective tissues around the knee joint based on shear wave elastography.

    abstract::Previous studies on knee biomechanics have mainly focused on the joint structure itself, largely neglecting the material properties of the muscles and connective tissues around the knee joint. Therefore, this study was purposed to conduct a systematic in vivo examination of the material properties of muscles, tendons,...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103829

    authors: Wu J,Qian Z,Liang W,Liu J,Ren L,Ren L

    更新日期:2020-09-01 00:00:00

  • An analytical solution for the stress state at stent-coating interfaces.

    abstract::In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.009

    authors: Parry G,McGarry P

    更新日期:2012-06-01 00:00:00

  • Evaluation of multi-scale mineralized collagen-polycaprolactone composites for bone tissue engineering.

    abstract::A particular challenge in biomaterial development for treating orthopedic injuries stems from the need to balance bioactive design criteria with the mechanical and geometric constraints governed by the physiological wound environment. Such trade-offs are of particular importance in large craniofacial bone defects whic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.032

    authors: Weisgerber DW,Erning K,Flanagan CL,Hollister SJ,Harley BAC

    更新日期:2016-08-01 00:00:00

  • Strain-induced microstructural rearrangement in ultra-high molecular weight polyethylene for hip joints: A comparison between conventional and vitamin E-infused highly-crosslinked liners.

    abstract::Infusion of vitamin E (α-tocopherol) in highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) liners has been conceived to achieve superior oxidation stability while preserving enhanced mechanical properties as compared to post-irradiation remelted liners. However, the presence of an antioxidant in the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.009

    authors: Takahashi Y,Yamamoto K,Shishido T,Masaoka T,Tateiwa T,Puppulin L,Pezzotti G

    更新日期:2014-03-01 00:00:00

  • Resin adjustment of three-dimensional printed thermoset occlusal splints: Bonding properties - Short communication.

    abstract:OBJECTIVES:To evaluate the interfacial adhesion of an autopolymerizing acrylic resin to 3D printed thermoset occlusal splints compared to thermoplastic occlusal splints. MATERIALS AND METHODS:Cylinders made of an autopolymerizing acrylic resin were adhered to 3D printed thermoset and also to thermoplastic plates. A di...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.011

    authors: Perea-Lowery L,Vallittu PK

    更新日期:2019-07-01 00:00:00

  • Role of porosity and matrix behavior on compressive fracture of Haversian bone using random spring network model.

    abstract::Haversian remodeling is known to result in improved resistance to compressive fracture in healthy cortical bone. Here, we examine the individual roles of the mean porosity, structure of the network of pores and remodeled bone matrix properties in the fracture behavior of Haversian bone. The detailed structure of poros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.013

    authors: Mayya A,Banerjee A,Rajesh R

    更新日期:2018-07-01 00:00:00

  • Mechanical properties enhancement of self-cured PMMA reinforced with zirconia and boron nitride nanopowders for high-performance dental materials.

    abstract::We report on the mechanical properties regarding self-cured acrylic polymethyl methacrylate (PMMA) reinforced with hexagonal boron nitride (h-BN) and stabilized zirconia (8Y ZrO2) nanopowders. The nanocomposites were prepared by using both manual and ultrasonic mixing techniques. The fabricated specimens were subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103937

    authors: Alqahtani M

    更新日期:2020-10-01 00:00:00

  • Interfacial indentations in biological composites.

    abstract::Biocomposites comprise highly stiff reinforcement elements connected by a compliant matrix material. While the interfacial elastic properties of these biocomposites play a key role in determining the mechanical properties of the entire biocomposite, these properties cannot be measured directly from standard nanomechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104209

    authors: Shelef Y,Bar-On B

    更新日期:2021-02-01 00:00:00

  • Reinforcing effect of graphene oxide reinforcement on the properties of poly (vinyl alcohol) and carboxymethyl tamarind gum based phase-separated film.

    abstract::The current study deals with the preparation and the characterization of the PVA-CMT-GO films. The PVA-CMT film was translucent in nature and smooth to touch. The addition of GO resulted in the formation of agglomerated structures. XRD studies suggested that the incorporation of GO increased the average crystallite si...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.021

    authors: Yadav I,Nayak SK,Rathnam VSS,Banerjee I,Ray SS,Anis A,Pal K

    更新日期:2018-05-01 00:00:00

  • Mechanisms and timing of injury to the thoracic, lumbar and sacral spine in simulated underbody blast PMHS impact tests.

    abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104271

    authors: Somasundaram K,Sherman D,Begeman P,Ciarelli T,McCarty SA,Kochkodan JJ,Demetropoulos CK,Cavanaugh JM

    更新日期:2020-12-24 00:00:00

  • Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis.

    abstract::For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.028

    authors: Marcos RL,Arnold G,Magnenet V,Rahouadj R,Magdalou J,Lopes-Martins RÁ

    更新日期:2014-01-01 00:00:00

  • Mechanical properties of bovine cortical bone based on the automated ball indentation technique and graphics processing method.

    abstract::Cortical bone provides the main form of support in humans and other vertebrates against various forces. Thus, capturing its mechanical properties is important. In this study, the mechanical properties of cortical bone were investigated by using automated ball indentation and graphics processing at both the macroscopic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.039

    authors: Zhang A,Zhang S,Bian C

    更新日期:2018-02-01 00:00:00

  • Human enamel rod presents anisotropic nanotribological properties.

    abstract::The AFM combined nanoindentation was performed to observe the ultrastructure of enamel rod from various section plans and positions while probing their mechanical and tribological properties of the area. The nanohardness and the elastic modulus of the head region of the enamel rods are significantly higher than that o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.002

    authors: Jeng YR,Lin TT,Hsu HM,Chang HJ,Shieh DB