Abstract:
:Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.
journal_name
J Breath Resjournal_title
Journal of breath researchauthors
Tisch U,Haick Hdoi
10.1088/1752-7155/8/2/027103subject
Has Abstractpub_date
2014-06-01 00:00:00pages
027103issue
2eissn
1752-7155issn
1752-7163journal_volume
8pub_type
杂志文章,评审abstract::This study aimed to analyze the impact of chewing gum on halitosis parameters. Three databases were searched with the following focused question: 'Can chewing gum additionally reduce halitosis parameters, such as organoleptic scores and volatile sulfur compounds (VSC), when compared to a control treatment'? Controlled...
journal_title:Journal of breath research
pub_type: 杂志文章,meta分析,评审
doi:10.1088/1752-7163/aa5cc2
更新日期:2017-02-17 00:00:00
abstract::The forehead was studied as a possible sampling site for capturing changes in volatile organic compound (VOC) profiles associated with psychological-stress. Skin-VOCs were sampled with a polydimethylsilicone (PDMS)-coupon and the resulting VOCs were recovered and analysed with two-stage thermal desorption gas chromato...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/4/046012
更新日期:2016-11-21 00:00:00
abstract::Radiation dose is important in radiotherapy. Too little, and the treatment is not effective, too much causes radiation toxicity. A biochemical measurement of the effect of radiotherapy would be useful in personalisation of this treatment. This study evaluated changes in exhaled breath volatile organic compounds (VOC) ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aba816
更新日期:2020-10-24 00:00:00
abstract::Leptin plays a key role in obstructive sleep apnea syndrome (OSAS). Leptin production in human airways has been previously evaluated by measuring leptin concentration in the exhaled breath condensate and in the induced sputum. The aim was to study leptin expression in the cells of induced sputum and in exhaled breath ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/4/3/036003
更新日期:2010-09-01 00:00:00
abstract::A point-of-care, non-invasive, low-cost and sensitive nano-biodiagnostic is needed in today's age for rapid and accurate self-diagnosis as well as for the management of asthma, which is advantageous for low resource areas where asthma is prevalent. The objective of this research work was to prepare the miniature, nano...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/ab1faf
更新日期:2019-06-25 00:00:00
abstract::Concentrations of exhaled volatile organic compounds (VOCs) may depend not only on biochemical or pathologic processes but also on physiological parameters. As breath sampling may be done in different body positions, effects of the sampling position on exhaled VOC concentrations were investigated by means of real-time...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/9/4/047105
更新日期:2015-11-19 00:00:00
abstract::Exhaled breath acetone (BrAce) was investigated during and after submaximal aerobic exercise as a volatile biomarker for metabolic responsiveness in high and lower-fit individuals in a prospective cohort pilot-study. Twenty healthy adults (19-39 years) with different levels of cardiorespiratory fitness (VO2peak), dete...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/abba6c
更新日期:2020-10-31 00:00:00
abstract::Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) represents an attractive tool for the real-time analysis of VOC profiles in human breath. Quantification of breath VOCs by means of direct MS may be affected by the matrix, as human breath not only contains several hundred VOCs at the ppbV-pptV lev...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa9eea
更新日期:2018-03-01 00:00:00
abstract::In the present longitudinal study, we followed volatile organic compounds (VOCs) excreted in exhaled breath of 20 healthy individuals over time, while adhering to a gluten-free diet for 4 weeks prior to adherence to a normal diet. We used gas chromatography coupled with mass spectrometry (TD-GC-tof-MS) in combination ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/7/3/037104
更新日期:2013-09-01 00:00:00
abstract::Volatile organic compounds (VOCs) in exhaled human breath can serve as potential disease-specific and exposure biomarkers and therefore can reveal information about a subject's health and environment. Pyridine, a VOC marker for exposure to tobacco smoke, and isoprene, a liver disease biomarker, were studied using atmo...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/7/2/026005
更新日期:2013-06-01 00:00:00
abstract::Staphylococcus aureus (S. aureus) is a common bacterium infecting children with cystic fibrosis (CF). Since current detection methods are difficult to perform in children, there is need for an alternative. This proof of concept study investigates whether breath profiles can discriminate between S. aureus infected and ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/4/046014
更新日期:2016-11-30 00:00:00
abstract::Rodent and nonhuman primate studies indicate that developmental programming by reduced perinatal nutrition negatively impacts life course cardio-metabolic health. We have developed a baboon model in which we feed control mothers (CON) ad libitum while nutrient restricted mothers are fed 70% of ad libitum global feed i...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aaba84
更新日期:2018-05-14 00:00:00
abstract::The current diagnostic challenge with diagnosing hepatic encephalopathy (HE) is identifying those with minimal HE as opposed to the more clinically apparent covert/overt HE. Rifaximin, is an effective therapy but earlier identification and treatment of HE could prevent liver disease progression and hospitalization. Ou...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/1/016012
更新日期:2016-02-11 00:00:00
abstract::Due to its high sensitivity, compact size and low cost ion mobility spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R = 90. In this study, we ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/2/026004
更新日期:2016-04-08 00:00:00
abstract::There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa8efe
更新日期:2017-12-06 00:00:00
abstract::The sensitivity of selected ion flow tube mass spectrometry, SIFT-MS, has been increased such that it is now possible to detect metabolites present at a part-per-billion, ppb, level in single breath exhalations. However, to utilize this improved sensitivity, the overlaps (coincidences) of those ions resulting from int...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/2/4/046003
更新日期:2008-12-01 00:00:00
abstract::The discovery of nitric oxide (NO) as a signalling and regulatory molecule and its subsequent detection in the exhaled breath has not only yielded new mechanistic insights but also diagnostic opportunities and therapeutic targets in several important medical conditions. In diseases involving chronic pulmonary inflamma...
journal_title:Journal of breath research
pub_type: 杂志文章,评审
doi:10.1088/1752-7155/7/1/017118
更新日期:2013-03-01 00:00:00
abstract:BACKGROUND:Asthma control does not yet meet the goals of asthma management guidelines. Non-invasive monitoring of airway inflammation may help to improve the level of asthma control in children. OBJECTIVES:(1) To identify a set of exhaled volatile organic compounds (VOCs) that is most predictive for an asthma exacerba...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa5a8b
更新日期:2017-03-01 00:00:00
abstract::Arterial lactate concentrations, taken as indicators of physical fitness, in athletes as well as in patients with cardio-respiratory or metabolic diseases, are measured invasively from arterialized ear lobe blood. Currently developed micro enzyme detectors permit a non-invasive measurement of hypoxia-related metabolit...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/4/1/017105
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND:The analysis of volatile organic compounds (VOCs) in breath allows non-invasive investigations of diseases. Animal studies are conducted as a model to perform research of VOCs and their relation to diseases. In large animal models ruminants were often used as experimental targets. The effect of their physiol...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aabdaf
更新日期:2018-05-14 00:00:00
abstract::The objective of this study is to evaluate tonsil odor as a contributor to halitosis and to study the reduction of oral malodor by mouth rinsing, without tonsil treatment. In 48 halitosis patients, tonsil odor and oral malodor were assessed through the 0-5 scale. In tonsil odor assessment, a dental burnisher was inser...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/2/1/017016
更新日期:2008-03-01 00:00:00
abstract::The results of experiments are described in which a known quantity of sterile deuterated water is injected directly into the pulmonary circulation via the right internal jugular vein of several haemodialysis patients and the deuterium to hydrogen ratio, D/H, in the exhaled lung water was measured using the flowing aft...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/6/3/036005
更新日期:2012-09-01 00:00:00
abstract::To investigate the premise that levels of endogenous volatile organic compounds (VOC) in breath reflect those in blood, the concentration of acetone and isoprene were measured in radial arterial blood, peripheral venous blood and breath samples from ten healthy volunteers. Coefficients of repeatability as a percentage...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/3/2/027005
更新日期:2009-06-01 00:00:00
abstract::The haloamines, including the chloramines (H(2)NCl, HNCl(2)) and bromamine (H(2)NBr), are diffusible gases that are likely to be produced during inflammation and so may be present as markers of lung inflammation on breath. Although haloamines are quite reactive, it is possible to measure these compounds in humid sampl...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/5/3/037105
更新日期:2011-09-01 00:00:00
abstract::Oxidative stress is associated with numerous health conditions and disorders, and aldehydes are known biomarkers of oxidative stress that can be non-invasively measured in exhaled human breath. Few studies report breath aldehyde levels in human populations, and none claim participant numbers in the hundreds or more. F...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/ab8865
更新日期:2020-07-21 00:00:00
abstract::Reactive oxygen species are associated with tissue inflammation and injury. Our laboratory has demonstrated that ethane, a stable product of lipid peroxidation, in exhaled breath can be used to measure total body oxidative stress. Herein patients were studied who underwent outpatient surgery, laproscopic bilateral tub...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/3/1/016002
更新日期:2009-03-01 00:00:00
abstract::Despite recent progress in Critical Care Medicine, sepsis is still a major medical problem with a high rate of mortality and morbidity especially in intensive care units. Oxidative stress induced by inflammation associated with sepsis causes degradation of heme protein, increases microsomal free heme content, promotes...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/4/4/047103
更新日期:2010-12-01 00:00:00
abstract::The measurement of the peak exhaled breath temperature (EBT) during multiple tidal breaths offers an easy, non-invasive tool for monitoring airway inflammation. Chronic obstructive pulmonary disease (COPD) is linked to airway inflammation, which is further aggravated by exacerbations of the disease. However, the peak ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/8/4/046002
更新日期:2014-09-18 00:00:00
abstract::Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced c...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/5/3/037111
更新日期:2011-09-01 00:00:00
abstract::Fractional exhaled NO (FeNO) is universally considered an indirect marker of eosinophilic airways inflammation, playing an important role in the physiopathology of childhood asthma. Advances in technology and standardization have allowed a wider use of FeNO in clinical practice in children from the age of four years. ...
journal_title:Journal of breath research
pub_type: 杂志文章,评审
doi:10.1088/1752-7155/6/2/027103
更新日期:2012-06-01 00:00:00