Measuring the compressive viscoelastic mechanical properties of human cervical tissue using indentation.

Abstract:

:The human cervix is an important mechanical barrier in pregnancy which must withstand the compressive and tensile forces generated from the growing fetus. Premature cervical shortening resulting from premature cervical remodeling and alterations of cervical material properties are known to increase a woman׳s risk of preterm birth (PTB). To understand the mechanical role of the cervix during pregnancy and to potentially develop indentation techniques for in vivo diagnostics to identify women who are at risk for premature cervical remodeling and thus preterm birth, we developed a spherical indentation technique to measure the time-dependent material properties of human cervical tissue taken from patients undergoing hysterectomy. In this study we present an inverse finite element analysis (IFEA) that optimizes material parameters of a viscoelastic material model to fit the stress-relaxation response of excised tissue slices to spherical indentation. Here we detail our IFEA methodology, report compressive viscoelastic material parameters for cervical tissue slices from nonpregnant (NP) and pregnant (PG) hysterectomy patients, and report slice-by-slice data for whole cervical tissue specimens. The material parameters reported here for human cervical tissue can be used to model the compressive time-dependent behavior of the tissue within a small strain regime of 25%.

authors

Yao W,Yoshida K,Fernandez M,Vink J,Wapner RJ,Ananth CV,Oyen ML,Myers KM

doi

10.1016/j.jmbbm.2014.01.016

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

18-26

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(14)00017-4

journal_volume

34

pub_type

杂志文章
  • A new longitudinal variation in the structure of collagen fibrils and its relationship to locations of mechanical damage susceptibility.

    abstract::The hierarchical architecture of the collagen fibril is well understood, involving non-integer staggering of collagen molecules which results in a 67 nm periodic molecular density variation termed D-banding. Other than this variation, collagen fibrils are considered to be homogeneous at the micro-scale and beyond. Int...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103849

    authors: Baldwin SJ,Sampson J,Peacock CJ,Martin ML,Veres SP,Lee JM,Kreplak L

    更新日期:2020-10-01 00:00:00

  • Constitutive modeling of human saphenous veins at overloading pressures.

    abstract::In the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and aniso...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.023

    authors: Veselý J,Horný L,Chlup H,Adámek T,Krajíček M,Žitný R

    更新日期:2015-05-01 00:00:00

  • Comparison of structural anisotropic soft tissue models for simulating Achilles tendon tensile behaviour.

    abstract::The incidence of tendon injury (tendinopathy) has increased over the past decades due to greater participation in sports and recreational activities. But little is known about the aetiology of tendon injuries because of our limited knowledge in the complex structure-function relationship in tendons. Computer models ca...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.007

    authors: Khayyeri H,Longo G,Gustafsson A,Isaksson H

    更新日期:2016-08-01 00:00:00

  • Novel microstructural findings in M. plantaris and their impact during active and passive loading at the macro level.

    abstract::There are several studies dealing with experimental and structural analyses of skeletal muscles that are aimed at gaining a better understanding of three-dimensional muscle deformation and force generation. A variety of these contributions have performed structural or mechanical analyses, but very few have combined th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.026

    authors: Böl M,Leichsenring K,Ernst M,Wick C,Blickhan R,Siebert T

    更新日期:2015-11-01 00:00:00

  • Mechanical evaluation by patient-specific finite element analyses demonstrates therapeutic effects for osteoporotic vertebrae.

    abstract::Osteoporosis can lead to bone compressive fractures in the lower lumbar vertebrae. In order to assess the recovery of vertebral strength during drug treatment for osteoporosis, it is necessary not only to measure the bone mass but also to perform patient-specific mechanical analyses, since the strength of osteoporotic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.03.001

    authors: Tawara D,Sakamoto J,Murakami H,Kawahara N,Oda J,Tomita K

    更新日期:2010-01-01 00:00:00

  • The use of hardened bone cement as an impaction grafting extender for revision hip arthroplasty.

    abstract::Impaction bone grafting is a method of restoring bone stock to patients who have suffered significant bone loss due to revision total hip surgery. The procedure requires morsellised cancellous bone (MCB) to be impacted into the site of bone loss in order to stabilise the prosthesis with the aim of long term resorption...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.002

    authors: Ruddy M,FitzPatrick DP,Stanton KT

    更新日期:2018-02-01 00:00:00

  • Numerical study of temperature effects on the poro-viscoelastic behavior of articular cartilage.

    abstract::This paper presents a new approach to study the effects of temperature on the poro- elastic and viscoelastic behavior of articular cartilage. Biphasic solid-fluid mixture theory is applied to study the poro-mechanical behavior of articular cartilage in a fully saturated state. The balance of linear momentum, mass, and...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.023

    authors: Behrou R,Foroughi H,Haghpanah F

    更新日期:2018-02-01 00:00:00

  • Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.

    abstract::This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.023

    authors: Liu Y,Zhu G,Yang H,Wang C,Zhang P,Han G

    更新日期:2018-01-01 00:00:00

  • Viscoelastic parameter identification of human brain tissue.

    abstract::Understanding the constitutive behavior of the human brain is critical to interpret the physical environment during neurodevelopment, neurosurgery, and neurodegeneration. A wide variety of constitutive models has been proposed to characterize the brain at different temporal and spatial scales. Yet, their model paramet...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.014

    authors: Budday S,Sommer G,Holzapfel GA,Steinmann P,Kuhl E

    更新日期:2017-10-01 00:00:00

  • Two-piece zirconia oral implants withstand masticatory loads: An investigation in the artificial mouth.

    abstract:OBJECTIVE:To evaluate the fracture resistance of two-piece zirconia oral implants after long-term thermomechanical cycling in an aqueous environment. Non-loaded samples and a one-piece implant system served as control groups. METHODS:A total of 48 zirconia implants were evaluated: 16 one-piece implants (ATZ; Group A) ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.005

    authors: Spies BC,Nold J,Vach K,Kohal RJ

    更新日期:2016-01-01 00:00:00

  • Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

    abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.020

    authors: Creechley JJ,Krentz ME,Lujan TJ

    更新日期:2017-05-01 00:00:00

  • Monotonic and cyclic loading behavior of porous scaffolds made from poly(para-phenylene) for orthopedic applications.

    abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.004

    authors: Hoyt AJ,Yakacki CM,Fertig RS 3rd,Dana Carpenter R,Frick CP

    更新日期:2015-01-01 00:00:00

  • Influence of cold rolling and ageing treatment on microstructure and mechanical properties of Ti-30Nb-5Ta-6Zr alloy.

    abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.06.006

    authors: Wang Y,Zhao J,Dai S,Chen F,Yu X,Zhang Y

    更新日期:2013-11-01 00:00:00

  • The error of tensile strength tests and an approach for improvement.

    abstract:OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.003

    authors: Behr M,Fuerst J,Rosentritt M

    更新日期:2018-11-01 00:00:00

  • Reinforcement of conventional glass-ionomer restorative material with short glass fibers.

    abstract::This study investigated the strengthening effect of glass fibers when added to conventional glass-ionomer restorative material. Glass fibers were incorporated into glass-ionomer powder in 3 wt% and 5 wt%. The fibers used had 1 mm length and 10 microm thickness. These criteria of fiber length, diameter, and concentrati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.04.002

    authors: Hammouda IM

    更新日期:2009-01-01 00:00:00

  • Clinical versus pre-clinical FE models for vertebral body strength predictions.

    abstract::The finite element analysis is an accepted method to predict vertebral body compressive strength. This study compares measurements obtained from in vitro tests with the ones from two different simulation models: clinical quantitative computer tomography (QCT) based homogenized finite element (hFE) models and pre-clini...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.11.018

    authors: Pahr DH,Schwiedrzik J,Dall'Ara E,Zysset PK

    更新日期:2014-05-01 00:00:00

  • Mechanisms and timing of injury to the thoracic, lumbar and sacral spine in simulated underbody blast PMHS impact tests.

    abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104271

    authors: Somasundaram K,Sherman D,Begeman P,Ciarelli T,McCarty SA,Kochkodan JJ,Demetropoulos CK,Cavanaugh JM

    更新日期:2020-12-24 00:00:00

  • Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations.

    abstract:PURPOSE:Limited information is available on the effect of Immediate Dentin Sealing (IDS) on the fracture strength of indirect partial posterior restorations. This study evaluated the effect of IDS on the fracture strength and failure types of two indirect restorative materials. MATERIALS AND METHODS:Standard MOD inlay...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.002

    authors: van den Breemer CRG,Özcan M,Cune MS,van der Giezen R,Kerdijk W,Gresnigt MMM

    更新日期:2017-08-01 00:00:00

  • Influence of Si addition on the microstructure and mechanical properties of Ti-35Nb alloy for applications in orthopedic implants.

    abstract::In the development of new materials for orthopedic implants, special attention has been given to Ti alloys that show biocompatible alloy elements and that are capable of reducing the elastic modulus. Accordingly, Ti-Nb-Si alloys show great potential for application. Thus, this is a study on the microstructures and pro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.035

    authors: Tavares AM,Ramos WS,de Blas JC,Lopes ES,Caram R,Batista WW,Souza SA

    更新日期:2015-11-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.

    abstract::In an attempt to study the mechanical behavior of bone under indentation, methods of analyses and experimental validations have been developed, with a selected test material. The test material chosen is from an equine cortical bone. Stress-strain relationships are first obtained from conventional mechanical property t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.020

    authors: Hoffseth K,Randall C,Hansma P,Yang HT

    更新日期:2015-02-01 00:00:00

  • Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant.

    abstract:OBJECTIVES:The aim of the present study was to investigate the surface characteristic, biomechanical behavior, hemocompatibility, bone tissue response and osseointegration of the optimal micro-arc oxidation surface-treated titanium (MST-Ti) dental implant. MATERIALS AND METHODS:The surface characteristic, biomechanica...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.042

    authors: Hou PJ,Ou KL,Wang CC,Huang CF,Ruslin M,Sugiatno E,Yang TS,Chou HH

    更新日期:2018-03-01 00:00:00

  • Cytocompatibility, mechanical and dissolution properties of high strength boron and iron oxide phosphate glass fibre reinforced bioresorbable composites.

    abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.011

    authors: Sharmin N,Hasan MS,Parsons AJ,Rudd CD,Ahmed I

    更新日期:2016-06-01 00:00:00

  • Articular cartilage surface rupture during compression: investigating the effects of tissue hydration in relation to matrix health.

    abstract::This study aimed at investigating articular cartilage rupture by investigating the response of healthy and degenerate cartilage through altering the osmotic swelling environment of surface-intact, cartilage-on-bone specimens. The osmotic environment in healthy and degenerate bovine cartilage was varied by soaking tiss...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.018

    authors: Fick JM,Espino DM

    更新日期:2011-10-01 00:00:00

  • Mechanical and microstructural properties of ultra-translucent dental zirconia ceramic stabilized with 5 mol% yttria.

    abstract::Monolithic dental prostheses fabricated from 3 mol.% yttria-stabilized zirconia (3YZ) are becoming increasingly popular. Recently, 5 mol.% yttria-stabilized zirconia (5YZ) which significantly improves the translucency of 3YZ has been prepared. However, its mechanical and microstructural properties, especially those af...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103974

    authors: Harada A,Shishido S,Barkarmo S,Inagaki R,Kanno T,Örtengren U,Egusa H,Nakamura K

    更新日期:2020-11-01 00:00:00

  • How mechanical stresses modulate enamel demineralization in non-carious cervical lesions?

    abstract:OBJECTIVE:To introduce an experimental non-carious cervical lesion (NCCL) model for studying the influence of presence and type of stress (tension or compression) on acid effects involved in NCCL formation on the enamel near the cement-enamel junction (CEJ). METHODS:108 bovine incisors were cut into 18 × 3×3 mm3 beams...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.11.003

    authors: Leal NMS,Silva JL,Benigno MIM,Bemerguy EA,Meira JBC,Ballester RY

    更新日期:2017-02-01 00:00:00

  • Tensile biomechanical properties and constitutive parameters of human corneal stroma extracted by SMILE procedure.

    abstract::The biomechanical behavior of human corneal stroma under uniaxial tension was investigated by the experimental analysis of cornea stromal lenticules taken out by corneal refractive surgery. Uniaxial tests were conducted to determine their stress-strain relationship and tensile strength. The Gasser-Ogden-Holzapfel (GOH...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.042

    authors: Xiang Y,Shen M,Xue C,Wu D,Wang Y

    更新日期:2018-09-01 00:00:00

  • Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

    abstract::Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morpho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.004

    authors: Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish K

    更新日期:2015-07-01 00:00:00

  • Preparation and properties of an injectable scaffold of poly(lactic-co-glycolic acid) microparticles/chitosan hydrogel.

    abstract::Hydrogels are more and more attractive in biomedical fields, since they can be used as injectable scaffolds, drugs and gene carriers and smart sensors. The highly hydrated hydrogels, however, generally have low mechanical strength. In this work, a composite chitosan hydrogel was prepared by blending water soluble and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.02.001

    authors: Hu X,Zhou J,Zhang N,Tan H,Gao C

    更新日期:2008-10-01 00:00:00

  • The effect of ethanol on surface of semi-interpenetrating polymer network (IPN) polymer matrix of glass-fibre reinforced composite.

    abstract:AIM OF THE STUDY:The aim of this laboratory study was to evaluate the effect of ethanol treatment on the surface roughness (Sa), nano-mechanical properties (NMP) and surface characterization of dental fiber reinforced composite (FRC) with semi-interpenetrating polymer network (IPN). MATERIALS AND METHODS:A total of 24...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.030

    authors: Basavarajappa S,Perea-Lowery L,Aati S,Abdullah Al-Kheraif AA,Ramakrishnaiah R,Matinlinna JP,Vallittu PK

    更新日期:2019-10-01 00:00:00