The error of tensile strength tests and an approach for improvement.

Abstract:

OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardized and the precision of the axially load transmission during the tensile force application optimized. Copings of CoCr-alloy were luted using a provisional zinc-oxide eugenol and a glass-ionomer cement (n = 20 per group each) on 4°, respectively 8° titanium implant abutment analogs. 24 h after luting the copings were pulled off with the improved (IPD) and the previous non improved device (NIPD). Means, std. dev. and t-tests were calculated. RESULTS:The stress- strain curves produced by the IPD showed a clear and linear relationship between stress and strain. The curves of the NIPD were ragged and chaotic. For both luting agents the means of the retentive force were considerable higher (p > 0.000) with IPD. However, the standard deviation was unimproved for the zinc oxide eugenol cement: IPD: 27%; NIPD: 27%, but significantly improved with glass ionomer: IPD: 16%, NIPD: 28%. CONCLUSION:The results from luting agents, which react like a solid body, may benefit from the optimized pull-off-device. Despite the fact that many factors in this investigation have been controlled, unknown flow characteristics of non-Newtonian-fluids like luting agents may have a considerable influence on the standard deviation of pull-off tests.

authors

Behr M,Fuerst J,Rosentritt M

doi

10.1016/j.jmbbm.2018.07.003

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

138-142

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(18)30761-6

journal_volume

87

pub_type

杂志文章
  • Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence.

    abstract::Anterior cervical discectomy with fusion is a common surgical treatment that can relieve patients suffering from cervical spondylosis. This surgery is most commonly performed with the use of a cervical cage. One serious complication of the fusion cages commercially available in the market is subsidence of the cage wit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.040

    authors: Moussa A,Tanzer M,Pasini D

    更新日期:2018-09-01 00:00:00

  • A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    abstract::A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.022

    authors: Abdelgaied A,Fisher J,Jennings LM

    更新日期:2018-02-01 00:00:00

  • Cutting mechanics of wood by beetle larval mandibles.

    abstract::Wood boring is a feature of several insect species and is a major cause of severe and irreparable damage to trees. Adult females typically deposit their eggs on the stem surface under bark scales. The emerging hatchlings live within wood during their larval phase, avoiding possible predation, whilst continually boring...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104027

    authors: Kundanati L,Chahare NR,Jaddivada S,Karkisaval AG,Sridhar R,Pugno NM,Gundiah N

    更新日期:2020-12-01 00:00:00

  • Mechanical properties and thermal behaviour of PEGDMA hydrogels for potential bone regeneration application.

    abstract::Poly(ethylene glycol) hydrogels are currently under investigation as possible scaffold materials for bone regeneration. The main purpose of this research was to analyse the mechanical properties and thermal behaviour of novel photopolymerised poly(ethylene glycol) dimethacrylate (PEGDMA) based hydrogels. The effect of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.004

    authors: Killion JA,Geever LM,Devine DM,Kennedy JE,Higginbotham CL

    更新日期:2011-10-01 00:00:00

  • Damage mechanisms in uniaxial compression of single enamel rods.

    abstract::Enamel possesses a complex hierarchical structure, which bestows this tissue with unique mechanical properties. In this study, the mechanical behavior of single enamel rods was investigated under uniaxial compression. Numerical simulations were also performed using micromechanics models for individual enamel rods to i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.014

    authors: An B,Wang R,Arola D,Zhang D

    更新日期:2015-02-01 00:00:00

  • The posterior eye with age-related macular degeneration has isotropic and nonlinear viscoelastic properties.

    abstract::Here we characterize and compare the anisotropic and nonlinear viscoelastic properties of the posterior eye of advanced dry age-related macular degeneration (AMD) patients and age-matched normal subjects. Ten normal horizontal, ten normal vertical, ten AMD horizontal, and ten AMD vertical strips of the macular retina ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104207

    authors: He Y,Guo Y,Wang J,Lv W,Li X,Chen K

    更新日期:2021-02-01 00:00:00

  • Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta.

    abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.024

    authors: Peña JA,Martínez MA,Peña E

    更新日期:2015-10-01 00:00:00

  • Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications.

    abstract::The incidence of total hip arthroplasty (THA) has been evidently growing over the last few decades. Surface modification, such as polymer grafting onto implant surfaces using poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC), has been gaining attention due to its excellent biocompatibility and high lubricity beha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103412

    authors: Ghosh S,Abanteriba S,Wong S,Houshyar S

    更新日期:2019-12-01 00:00:00

  • Effects of crystal refining on wear behaviors and mechanical properties of lithium disilicate glass-ceramics.

    abstract:OBJECTIVES:The purpose of this study is to improve wear resistance and mechanical properties of lithium disilicate glass-ceramics by refining their crystal sizes. METHODS:After lithium disilicate glass-ceramics (LD) were melted to form precursory glass blocks, bar (N = 40, n = 10) and plate (N = 32, n = 8) specimens w...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.023

    authors: Zhang Z,Guo J,Sun Y,Tian B,Zheng X,Zhou M,He L,Zhang S

    更新日期:2018-05-01 00:00:00

  • A combined strategy to enhance the properties of Zn by laser rapid solidification and laser alloying.

    abstract::The orthopedic application of Zn is limited owing to the poor strength and low plasticity. In this study, a novel strategy by combining rapid solidification obtained by selective laser melting (SLM) and alloying with Mg was proposed to improve the mechanical properties of Zn. The microstructures, mechanical properties...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.018

    authors: Yang Y,Yuan F,Gao C,Feng P,Xue L,He S,Shuai C

    更新日期:2018-06-01 00:00:00

  • Effect of Cu on microstructure, mechanical properties, corrosion resistance and cytotoxicity of CoCrW alloy fabricated by selective laser melting.

    abstract::In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated tha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.026

    authors: Lu Y,Ren L,Xu X,Yang Y,Wu S,Luo J,Yang M,Liu L,Zhuang D,Yang K,Lin J

    更新日期:2018-05-01 00:00:00

  • Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin.

    abstract:OBJECTIVES:To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS:In 80 human molars, occlusal tooth substance was removed so that the defects ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.006

    authors: Maeder M,Pasic P,Ender A,Özcan M,Benic GI,Ioannidis A

    更新日期:2019-07-01 00:00:00

  • Characterization and restoration of degenerated IVD function with an injectable, in situ gelling alginate hydrogel: An in vitro and ex vivo study.

    abstract::Intervertebral disc (IVD) degeneration is a naturally, irreparable process that causes loss in IVD hydration, cellularity, and, mechanical stability. Invasive surgical attempts to ease back pain and, radiculopathy have shown to cause increased degeneration along the rest, of the spine. Due to its highly tunable mechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.014

    authors: Growney Kalaf EA,Pendyala M,Bledsoe JG,Sell SA

    更新日期:2017-08-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening.

    abstract::Many treatments for cardiovascular diseases include an endovascular insertion of stents or stent grafts into arteries, a procedure which may cause high tissue stresses and even damage in the arterial wall. In order to study such problems by using finite element methods, both appropriate constitutive models and experim...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.03.012

    authors: Weisbecker H,Pierce DM,Regitnig P,Holzapfel GA

    更新日期:2012-08-01 00:00:00

  • Cell elasticity with altered cytoskeletal architectures across multiple cell types.

    abstract::The cytoskeleton is primarily responsible for providing structural support, localization and transport of organelles, and intracellular trafficking. The structural support is supplied by actin filaments, microtubules, and intermediate filaments, which contribute to overall cell elasticity to varying degrees. We evalua...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.01.022

    authors: Grady ME,Composto RJ,Eckmann DM

    更新日期:2016-08-01 00:00:00

  • µ-Particle tracking velocimetry and computational fluid dynamics study of cell seeding within a 3D porous scaffold.

    abstract::Cell seeding of 3D scaffolds is a critical step in tissue engineering since the final tissue properties are related to the initial cell distribution and density within the scaffold unit. Perfusion systems can transport cells to the scaffold however; the fact that cells flow inside the scaffold pores does not guarantee...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.003

    authors: Marin AC,Grossi T,Bianchi E,Dubini G,Lacroix D

    更新日期:2017-11-01 00:00:00

  • Development of novel zirconia implant's materials gradated design with improved bioactive surface.

    abstract::Zirconia implants are becoming a preference choice for different applications such as knee, dental, among others. In order to improve osseointegration, implant's surfaces are usually coated with bioactive materials like hydroxyapatite (HAp) and beta-tricalcium phosphate (β-TCP) that are very similar to the calcium pho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.02.022

    authors: Faria D,Pires JM,Boccaccini AR,Carvalho O,Silva FS,Mesquita-Guimarães J

    更新日期:2019-06-01 00:00:00

  • Influence of Si addition on the microstructure and mechanical properties of Ti-35Nb alloy for applications in orthopedic implants.

    abstract::In the development of new materials for orthopedic implants, special attention has been given to Ti alloys that show biocompatible alloy elements and that are capable of reducing the elastic modulus. Accordingly, Ti-Nb-Si alloys show great potential for application. Thus, this is a study on the microstructures and pro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.035

    authors: Tavares AM,Ramos WS,de Blas JC,Lopes ES,Caram R,Batista WW,Souza SA

    更新日期:2015-11-01 00:00:00

  • Comparison of splinted and non-splinted superstructures of three implants placed in a mandibular distal extension model with missing teeth using modal analysis.

    abstract::This study evaluated the effects of two types of superstructures (splinted crown and non-splinted crown) on four vibration characteristics (natural frequency, damping ratio (DAR), vectors in antiphase, maximum displacement (MDP)) by using modal analysis. These structures were fabricated on three implants placed in the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104050

    authors: Sasaki T,Nakata H,Suzuki A,Hada T,Kasugai S,Kuroda S

    更新日期:2020-12-01 00:00:00

  • Two-body wear of dental restorative materials.

    abstract:AIM:The aim of this in vitro study was to determine the two-body wear resistance of modern direct dental restorative materials. METHODS:Eight standardized specimens were prepared from 14 dental restorative materials (nano-, micro-, hybrid-, macrofilled composites; compomer, silorane, ormocer); a veneering composite (S...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.06.001

    authors: Hahnel S,Schultz S,Trempler C,Ach B,Handel G,Rosentritt M

    更新日期:2011-04-01 00:00:00

  • Vancomycin elution, activity and impact on mechanical properties when added to orthopedic bone cement.

    abstract::Infection incidence for total hip and knee arthroplasty (THA and TKA, respectively) is between 0.2% and 5% and results in approximately 100,000 device failures per year in the United States. Treatment requires prolonged systemic antibiotic therapy with additional surgical revisions. As a prophylactic measure against i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.033

    authors: Bishop AR,Kim S,Squire MW,Rose WE,Ploeg HL

    更新日期:2018-11-01 00:00:00

  • Custom-built electrostatics and supplementary bonding in the design of reinforced Collagen-g-P(methyl methacrylate-co-ethyl acrylate)/ nylon 66 core-shell fibers.

    abstract::In this study, Acid Soluble Collagen-g-P(methyl methacrylate-co-ethyl acrylate) (CME) was synthesized to take advantage of the flexibility of the resulted branched polymer chains and the high density of their chain entanglement. The coaxial electrospinning technique was applied to study the effect of electrically and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.002

    authors: Bazrafshan Z,Stylios GK

    更新日期:2018-11-01 00:00:00

  • Frequency-modulated atomic force microscopy localises viscoelastic remodelling in the ageing sheep aorta.

    abstract::Age-related aortic stiffening is associated with cardiovascular diseases such as heart failure. The mechanical functions of the main structural components of the aorta, such as collagen and elastin, are determined in part by their organisation at the micrometer length scale. With age and disease both components underg...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.07.018

    authors: Akhtar R,Graham HK,Derby B,Sherratt MJ,Trafford AW,Chadwick RS,Gavara N

    更新日期:2016-12-01 00:00:00

  • A comparative study of the mechanical properties of a dinosaur and crocodile fossil teeth.

    abstract::Vertebrate teeth are complex structures adapted in terms of shape and structure to serve a variety of functions like biting and grinding. Thus, examining the morphology, composition and mechanical properties of the teeth can aid in providing insights into the feeding behaviour of extinct species. We here provide the f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.025

    authors: Kundanati L,D'Incau M,Bernardi M,Scardi P,Pugno NM

    更新日期:2019-09-01 00:00:00

  • Unusual effect evidenced at the investigations of the mechanical behavior of composite hydrogels under cyclic compression.

    abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.030

    authors: Gofman IV,Buyanov AL

    更新日期:2017-07-01 00:00:00

  • Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva.

    abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.019

    authors: Licausi MP,Igual Muñoz A,Amigó Borrás V

    更新日期:2013-04-01 00:00:00

  • R-curve behavior of a short-fiber reinforced resin composite after water storage.

    abstract::As a supplement to our investigation into R-curves in a short-fiber reinforced dental resin composite, we investigate the effects of 2-months water storage. Water is known to degrade the siloxane bonds linking matrix and fillers, which has been suggested to decrease the fracture toughness in conventional resin composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103674

    authors: Tiu J,Belli R,Lohbauer U

    更新日期:2020-04-01 00:00:00

  • Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations.

    abstract:PURPOSE:Limited information is available on the effect of Immediate Dentin Sealing (IDS) on the fracture strength of indirect partial posterior restorations. This study evaluated the effect of IDS on the fracture strength and failure types of two indirect restorative materials. MATERIALS AND METHODS:Standard MOD inlay...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.002

    authors: van den Breemer CRG,Özcan M,Cune MS,van der Giezen R,Kerdijk W,Gresnigt MMM

    更新日期:2017-08-01 00:00:00

  • Mechanical characterization and modelling of the temperature-dependent impact behaviour of a biocompatible poly(L-lactide)/poly(ε-caprolactone) polymer blend.

    abstract::Poly(ε-caprolactone) (PCL) is a ductile, bioabsorbable polymer that has been employed as a blend partner for poly(L-lactic acid) (PLLA). An improvement of the material strength and impact resistance of PLLA/PCL polymer blends compared to pure PLLA has been shown previously. To use numerical simulations in the design p...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.007

    authors: Gustafsson G,Nishida M,Ito Y,Häggblad HÅ,Jonsén P,Takayama T,Todo M