Quantitative (1)H MRI, (19)F MRI, and (19)F MRS of cell-internalized perfluorocarbon paramagnetic nanoparticles.

Abstract:

:In vivo molecular imaging with targeted MRI contrast agents will require sensitive methods to quantify local concentrations of contrast agent, enabling not only imaging-based recognition of pathological biomarkers but also detection of changes in expression levels as a consequence of disease development, therapeutic interventions or recurrence of disease. In recent years, targeted paramagnetic perfluorocarbon emulsions have been frequently applied in this context, permitting high-resolution (1)H MRI combined with quantitative (19)F MR imaging or spectroscopy, under the assumption that the fluorine signal is not altered by the local tissue and cellular environment. In this in vitro study we have investigated the (19)F MR-based quantification potential of a paramagnetic perfluorocarbon emulsion conjugated with RGD-peptide to target the cell-internalizing α(ν)β(3)-integrin expressed on endothelial cells, using a combination of (1)H MRI, (19)F MRI and (19)F MRS. The cells took up the targeted emulsion to a greater extent than nontargeted emulsion. The targeted emulsion was internalized into large 1-7 µm diameter vesicles in the perinuclear region, whereas nontargeted emulsion ended up in 1-4 µm diameter vesicles, which were more evenly distributed in the cytoplasm. Association of the targeted emulsion with the cells resulted in different proton longitudinal relaxivity values, r(1), for targeted and control nanoparticles, prohibiting unambiguous quantification of local contrast agent concentration. Upon cellular association, the fluorine R(1) was constant with concentration, while the fluorine R(2) increased nonlinearly with concentration. Even though the fluorine relaxation rate was not constant, the (19)F MRI and (19)F MRS signals for both targeted nanoparticles and controls were linear and quantifiable as function of nanoparticle concentration.

authors

Kok MB,de Vries A,Abdurrachim D,Prompers JJ,Grüll H,Nicolay K,Strijkers GJ

doi

10.1002/cmmi.398

subject

Has Abstract

pub_date

2011-01-01 00:00:00

pages

19-27

issue

1

eissn

1555-4309

issn

1555-4317

journal_volume

6

pub_type

杂志文章
  • Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes?

    abstract::Targeted magnetic resonance contrast agents (e.g. iron oxide nanoparticles) have the potential to become highly selective imaging tools. In this context, quantification of the coupled amount of protein is essential for the design of antibody- or antibody fragment-conjugated nanoparticles. Nevertheless, the presence of...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.405

    authors: Rimkus G,Bremer-Streck S,Grüttner C,Kaiser WA,Hilger I

    更新日期:2011-05-01 00:00:00

  • Minimization of self-quenching fluorescence on dyes conjugated to biomolecules with multiple labeling sites via asymmetrically charged NIR fluorophores.

    abstract::Self-aggregation of dyes even at low concentrations poses a considerable challenge in preparing sufficiently bright molecular probes for in vivo imaging, particularly in the conjugation of near infrared cyanine dyes to polypeptides with multiple labeling sites. Such self-aggregation leads to a significant energy trans...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1585

    authors: Zhegalova NG,He S,Zhou H,Kim DM,Berezin MY

    更新日期:2014-09-01 00:00:00

  • How to perform accurate and reliable measurements of longitudinal and transverse relaxation times of MRI contrast media in aqueous solutions.

    abstract::Knowledge of the longitudinal and transverse relaxation times (T(1) and T(2)) of water protons in an aqueous solution of an MRI contrast agent is essential for its characterization. These parameters can be measured at low field on low resolution spectrometers or at high field on high resolution spectrometers. The reli...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.294

    authors: Henoumont C,Laurent S,Vander Elst L

    更新日期:2009-11-01 00:00:00

  • Labeling of multiple cell lines using a new iron oxide agent for cell tracking by MRI.

    abstract::Stem cells, cancer cells and immune cells were labeled by co-incubation with a new ultra-small iron oxide nanoparticle called Molday ION Rhodamine-B (MIRB). Iron staining, fluorescence imaging, transmission electron microscopy and flow cytometry were used to assess cell viability, function and labeling efficiency. Thi...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.456

    authors: McFadden C,Mallett CL,Foster PJ

    更新日期:2011-11-01 00:00:00

  • Novel Gd(III)-based probes for MR molecular imaging of matrix metalloproteinases.

    abstract::Two novel Gd-based contrast agents (CAs) for the molecular imaging of matrix metalloproteinases (MMPs) were synthetized and characterized in vitro and in vivo. These probes were based on the PLG*LWAR peptide sequence, known to be hydrolyzed between Gly and Leu by a broad panel of MMPs. A Gd-DOTA chelate was conjugated...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.478

    authors: Gringeri CV,Menchise V,Rizzitelli S,Cittadino E,Catanzaro V,Dati G,Chaabane L,Digilio G,Aime S

    更新日期:2012-03-01 00:00:00

  • Magnetosomes Extracted from Magnetospirillum gryphiswaldense as Theranostic Agents in an Experimental Model of Glioblastoma.

    abstract::Magnetic fluid hyperthermia (MFH) with chemically synthesized nanoparticles is currently used in clinical trials as it destroys tumor cells with an extremely localized deposition of thermal energy. In this paper, we investigated an MFH protocol based on magnetic nanoparticles naturally produced by magnetotactic bacter...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/2198703

    authors: Mannucci S,Tambalo S,Conti G,Ghin L,Milanese A,Carboncino A,Nicolato E,Marinozzi MR,Benati D,Bassi R,Marzola P,Sbarbati A

    更新日期:2018-07-11 00:00:00

  • Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    abstract::Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have lim...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1578

    authors: Clavijo Jordan MV,Beeman SC,Baldelomar EJ,Bennett KM

    更新日期:2014-09-01 00:00:00

  • Dynamic manganese-enhanced magnetic resonance imaging can detect chronic cryoinjury-induced infarction in pig hearts in vivo.

    abstract::The purpose was to investigate whether MnCl(2) can serve as an MRI contrast agent to detect chronic cryoinjury infarction in pigs in vivo and whether MnCl(2) causes significant hemodynamic disturbances. Hearts were subjected to a topical 2 min cryothermia to establish myocardial infarction (MI). Thereafter GdDTPA-enha...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.438

    authors: Yang Y,de Gervai PD,Sun J,Gruwel ML,Kupriyanov V

    更新日期:2011-11-01 00:00:00

  • Radiation Necrosis, Pseudoprogression, Pseudoresponse, and Tumor Recurrence: Imaging Challenges for the Evaluation of Treated Gliomas.

    abstract::Glioblastoma (GBM) is the most common primary malignant type of brain neoplasm in adults and carries a dismal prognosis. The current standard of care for GBM is surgical excision followed by radiation therapy (RT) with concurrent and adjuvant temozolomide-based chemotherapy (TMZ) by six additional cycles. In addition,...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2018/6828396

    authors: Zikou A,Sioka C,Alexiou GA,Fotopoulos A,Voulgaris S,Argyropoulou MI

    更新日期:2018-12-02 00:00:00

  • Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability.

    abstract:Background:To investigate same day 18F-FDG (Fluorodeoxyglucose) PET (Positron Emission Tomography)/MR (Magnetic Resonance) test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV) and lean body mass (SUL) in different locations in the liver. Methods:This prospective study wa...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/8639731

    authors: Domachevsky L,Bernstine H,Nidam M,Stein D,Goldberg N,Stern D,Abadi-Korek I,Groshar D

    更新日期:2017-05-30 00:00:00

  • 99mTc-CXCR4-L for Imaging of the Chemokine-4 Receptor Associated with Brain Tumor Invasiveness: Biokinetics, Radiation Dosimetry, and Proof of Concept in Humans.

    abstract::Overexpression of the chemokine-4 receptor (CXCR4) in brain tumors is associated with high cancer cell invasiveness. Recently, we reported the preclinical evaluation of 99mTc-CXCR4-L (cyclo-D-Tyr-D-[NMe]Orn[EDDA-99mTc-6-hydrazinylnicotinyl]-Arg-NaI-Gly) as a SPECT radioligand capable of specifically detecting the CXCR...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2020/2525037

    authors: Vallejo-Armenta P,Santos-Cuevas C,Soto-Andonaegui J,Villanueva-Pérez RM,González-Díaz JI,García-Pérez FO,Arrellano-Zarate A,Luna-Gutiérrez M,Azorín-Vega E,Ocampo-García B,Ferro-Flores G

    更新日期:2020-04-27 00:00:00

  • Multimodal approach to assess tumour vasculature and potential treatment effect with DCE-US and DCE-MRI quantification in CWR22 prostate tumour xenografts.

    abstract::The aim of this study was to compare intratumoural heterogeneity and longitudinal changes assessed by dynamic contrast-enhanced ultrasound (DCE-US) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in prostate tumour xenografts. In vivo DCE-US and DCE-MRI were obtained 24 h pre- (day 0) and post- (day...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1645

    authors: Arteaga-Marrero N,Rygh CB,Mainou-Gomez JF,Nylund K,Roehrich D,Heggdal J,Matulaniec P,Gilja OH,Reed RK,Svensson L,Lutay N,Olsen DR

    更新日期:2015-11-01 00:00:00

  • Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    abstract::Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive a...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1653

    authors: Abakumova T,Abakumov M,Shein S,Chelushkin P,Bychkov D,Mukhin V,Yusubalieva G,Grinenko N,Kabanov A,Nukolova N,Chekhonin V

    更新日期:2016-01-01 00:00:00

  • Phenylboronate 160Tb complexes for molecular recognition of glycoproteins expressed on tumor cells.

    abstract::The over-expression of sialic acid on the surface of cancer cells compared with normal ones makes this nine-carbon sugar an attractive biomarker for molecular diagnosis and therapy. Here, we describe a study on the molecular recognition of sialic acid end groups on the surface of human glioma cells by (160)Tb-DTPA-EN(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.123

    authors: Djanashvili K,Koning GA,van der Meer AJ,Wolterbeek HT,Peters JA

    更新日期:2007-01-01 00:00:00

  • Assessment of the biodistribution of an [(18) F]FDG-loaded perfluorocarbon double emulsion using dynamic micro-PET in rats.

    abstract::Perfluorocarbon (PFC) double emulsions loaded with a water-soluble, therapeutic agent can be triggered by ultrasound in a process known as acoustic droplet vaporization. Elucidating the stability and biodistribution of these sonosensitive vehicles and encapsulated agents is critical in developing targeted drug deliver...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1532

    authors: Fabiilli ML,Piert MR,Koeppe RA,Sherman PS,Quesada CA,Kripfgans OD

    更新日期:2013-07-01 00:00:00

  • Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    abstract::Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitativ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1569

    authors: Sun PZ,Wang Y,Dai Z,Xiao G,Wu R

    更新日期:2014-07-01 00:00:00

  • Head and Neck Cancer Tumor Segmentation Using Support Vector Machine in Dynamic Contrast-Enhanced MRI.

    abstract:Objective:We aimed to propose an automatic method based on Support Vector Machine (SVM) and Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) to segment the tumor lesions of head and neck cancer (HNC). Materials and Methods:120 DCE-MRI samples were collected. Five curve features and two principal componen...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/8612519

    authors: Deng W,Luo L,Lin X,Fang T,Liu D,Dan G,Chen H

    更新日期:2017-09-07 00:00:00

  • Classification of acute and delayed contrast media-induced reactions: proposal of a three-step system.

    abstract::Physicians and scientists use a broad spectrum of terms to classify contrast media (CM)-induced adverse reactions. In particular, the designation of hypersensitivity reactions is quite varied. Consequently, comparisons of different papers dealing with this subject are difficult or even impossible. Moreover, general de...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1475

    authors: Böhm I,Heverhagen JT,Klose KJ

    更新日期:2012-11-01 00:00:00

  • A First Report on [18F]FPRGD2 PET/CT Imaging in Multiple Myeloma.

    abstract::An observational study was set up to assess the feasibility of [18F]FPRGD2 PET/CT for imaging patients with multiple myeloma (MM) and to compare its detection rate with low dose CT alone and combined [18F]NaF/[18F]FDG PET/CT images. Four patients (2 newly diagnosed patients and 2 with relapsed MM) were included and un...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/6162845

    authors: Withofs N,Cousin F,De Prijck B,Bonnet C,Hustinx R,Gambhir SS,Beguin Y,Caers J

    更新日期:2017-07-27 00:00:00

  • Characterization of MRI contrast agent-loaded polymeric nanocapsules as versatile vehicle for targeted imaging.

    abstract::Various contrast agents (Magnevist, Gadovist and Multihance) loaded into polymeric nanocapsules were synthesized by the inverse miniemulsion technique. The relaxivity of the resultant contrast agents was assessed at 1.5 T magnetic field strength. The ionic relaxivity of the contrast agents could at least be maintained...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.364

    authors: Sharma S,Paiphansiri U,Hombach V,Mailänder V,Zimmermann O,Landfester K,Rasche V

    更新日期:2010-03-01 00:00:00

  • An imageable retinoid acid derivative to detect human cancer xenografts and study therapeutic dosing to reduce its toxicity.

    abstract::Developing agents with 'seek, treat and see' capability is critical for personalized molecular medicine. Those agents will specifically target the disease markers for diagnosis and apply the biologically effective dose for treatment. Retinoids regulate a multitude of biological processes. In addition, retinoic acid ca...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.419

    authors: Wang W,Qiu X,Zhang F,Sun J,Cameron AG,Wendt JA,Mawad ME,Ke S

    更新日期:2011-07-01 00:00:00

  • Uniform mesoporous silica coated iron oxide nanoparticles as a highly efficient, nontoxic MRI T(2) contrast agent with tunable proton relaxivities.

    abstract::Monodisperse mesoporous silica (mSiO(2) ) coated superparamagnetic iron oxide (Fe(3) O(4) @mSiO(2) ) nanoparticles (NPs) have been developed as a potential magnetic resonance imaging (MRI) T(2) contrast agent. To evaluate the effect of surface coating on MRI contrast efficiency, we examined the proton relaxivities of ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1473

    authors: Ye F,Laurent S,Fornara A,Astolfi L,Qin J,Roch A,Martini A,Toprak MS,Muller RN,Muhammed M

    更新日期:2012-09-01 00:00:00

  • Influence of paramagnetic melanin on the MRI contrast in melanoma: a combined high-field (11.7 T) MRI and EPR study.

    abstract::Melanoma is the most dangerous form of skin cancer and its incidence is rising each year. Because the current methods of diagnosis based on the visual aspect of the tumor show limitations, several new techniques are emerging to help in this diagnosis, amongst which are magnetic resonance imaging (MRI) and electron par...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1554

    authors: Godechal Q,Mignion L,Karroum O,Magat J,Danhier P,Morandini R,Ghanem GE,Leveque P,Gallez B

    更新日期:2014-03-01 00:00:00

  • VCAM-1-targeting gold nanoshell probe for photoacoustic imaging of atherosclerotic plaque in mice.

    abstract::The development of molecular probes and novel imaging modalities, allowing better resolution and specificity, is associated with an increased potential for molecular imaging of atherosclerotic plaques especially in basic and pre-clinical research applications. In that context, a photoacoustic molecular probe based on ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1491

    authors: Rouleau L,Berti R,Ng VW,Matteau-Pelletier C,Lam T,Saboural P,Kakkar AK,Lesage F,Rhéaume E,Tardif JC

    更新日期:2013-01-01 00:00:00

  • 99mTc-Radiolabeled TPGS Nanomicelles Outperform 99mTc-Sestamibi as Breast Cancer Imaging Agent.

    abstract::D-α-Tocopheryl polyethylene glycol 1000 succinate (TPGS) is a Food and Drug Administration (FDA) approved biomaterial that can form nanosized micelles in aqueous solution. TPGS micelles stand as an interesting system to perform drug delivery as they can carry lipophilic drugs and overcome P glycoprotein efflux as well...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/4087895

    authors: Tesan FC,Nicoud MB,Nuñez M,Medina VA,Chiappetta DA,Salgueiro MJ

    更新日期:2019-04-23 00:00:00

  • Electron paramagnetic resonance as a sensitive tool to assess the iron oxide content in cells for MRI cell labeling studies.

    abstract::MRI cell tracking is a promising technique to track various cell types (stem cells, tumor cells, etc.) in living animals. Usually, cells are incubated with iron oxides (T(2) contrast agent) in order to take up the particles before being injected in vivo. Iron oxide quantification is important in such studies for valid...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.497

    authors: Danhier P,De Preter G,Boutry S,Mahieu I,Leveque P,Magat J,Haufroid V,Sonveaux P,Bouzin C,Feron O,Muller RN,Jordan BF,Gallez B

    更新日期:2012-05-01 00:00:00

  • Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    abstract::Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1695

    authors: Kingston MJ,Perriman DM,Neeman T,Smith PN,Webb AL

    更新日期:2016-07-01 00:00:00

  • Dynamic contrast-enhanced computed tomography for the quantification of tumor response to vasoactive agents in a rat tumor model: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this pilot study was to establish the ability of dynamic contrast enhanced computed tomography (DCE-CT) to detect changes in tumor blood flow (BF) and oxygenation induced by vasoactive substances in rats. MATERIALS AND METHODS:Under ultrasound guidance, a fiber-optic probe was g...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.399

    authors: Pollard RE,Larson RF

    更新日期:2011-01-01 00:00:00

  • Considerations for the clinical use of contrast agents for cellular MRI in regenerative medicine.

    abstract::Advances in regenerative medicine are rapidly transforming healthcare. A cornerstone of regenerative medicine is the introduction of cells that were grown or manipulated in vitro. Key questions that arise after these cells are re-introduced are: whether these cells are localized in the appropriate site; whether cells ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1002/cmmi.1547

    authors: Modo M,Kolosnjaj-Tabi J,Nicholls F,Ling W,Wilhelm C,Debarge O,Gazeau F,Clement O

    更新日期:2013-11-01 00:00:00

  • Real-time 3D MRI of contrast agents in whole living mice.

    abstract::A specific mouse whole body coil and a dedicated gradient system at 4.7 T were coupled with an ultra-fast 3D gradient echo MRI and keyhole reconstruction technique to obtain 3D whole-body dynamic T(1)-weighted or T(2)*-weighted imaging. The technique was used to visualize the real-time distribution of non-targeting T(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.429

    authors: Bled E,Hassen WB,Pourtau L,Mellet P,Lanz T,Schüler D,Voisin P,Franconi JM,Thiaudière E,Miraux S

    更新日期:2011-07-01 00:00:00