A rapid method for the quantitation of estrogen receptors in small amounts of tissue.

Abstract:

:A rapid and highly reproducible protocol which permits the detection of quantities of estrogen receptor as low as 5 fmol/mg protein is described. The separation of free and receptor-bound hormone is achieved by specific immunoprecipitation of the hormone-receptor complex. This procedure can be performed without perturbing the equilibrium of the binding reaction.

journal_name

J Immunol Methods

authors

Bettini E,Maggi A

doi

10.1016/0022-1759(91)90234-7

subject

Has Abstract

pub_date

1991-11-05 00:00:00

pages

87-91

issue

1

eissn

0022-1759

issn

1872-7905

pii

0022-1759(91)90234-7

journal_volume

144

pub_type

杂志文章
  • A general and mild procedure for the purification of rabbit Fab' antibodies.

    abstract::A mild procedure for the purification of rabbit Fab' antibodies is described. A small column of normal goat IgG-Sepharose 4B (3 cm x 5mm) was saturated with F(ab')2 prepared from rabbit anti-goat IgG, and anti-goat IgG Fab was eluted from the column by splitting the disulfide bond in the hinge of the F(ab')2 molecule ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(80)90336-1

    authors: Ishikawa E,Yoshitake S

    更新日期:1980-01-01 00:00:00

  • A monoclonal antibody may show cross-reactivities in Ouchterlony assays but not in other assays.

    abstract::A monoclonal antibody to human IgG was tested with myeloma proteins of the four IgG subclasses. When tested by immunofluorometric assay, enzyme-linked immunosorbent assay, hemagglutination and hemagglutination inhibition assays, the antibody reacted with IgG3 but not with the other three IgG subclasses. When tested by...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(87)90317-6

    authors: Molinaro GA,Eby WC,Reimer C

    更新日期:1987-02-11 00:00:00

  • Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay.

    abstract::Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP) conjugated aptamer was...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2020.112942

    authors: Zhao J,Chang W,Liu L,Xing X,Zhang C,Meng H,Gopinath SCB,Lakshmipriya T,Chen Y,Liu Y

    更新日期:2021-02-01 00:00:00

  • Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7.

    abstract::E. coli O157:H7 is a pathogenic microorganism that has been implicated in numerous cases of foodborne illnesses. A variety of rapid methods exist that show promise for the presumptive detection of this pathogen without the immediate need for incubating test samples for hours to days in microbial enrichment and culture...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2004.07.004

    authors: Gehring AG,Irwin PL,Reed SA,Tu SI,Andreotti PE,Akhavan-Tafti H,Handley RS

    更新日期:2004-10-01 00:00:00

  • Characterization of in vitro antibody-dependent cell-mediated cytotoxicity activity of therapeutic antibodies - impact of effector cells.

    abstract::Antibody-dependent cell-mediated cytotoxicity (ADCC) is an important mechanism of action implicated in the clinical efficacy of several therapeutic antibodies. In vitro ADCC assays employing effector cells capable of inducing lysis of target cells bound by antibodies are routinely performed to support the research and...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2014.03.021

    authors: Chung S,Lin YL,Reed C,Ng C,Cheng ZJ,Malavasi F,Yang J,Quarmby V,Song A

    更新日期:2014-05-01 00:00:00

  • An enzyme immunoassay for carcinoembryonic antigen (CEA) with homogeneous reactivity to different CEA preparations and low cross-reactivity with CEA-related normal antigens.

    abstract::A new sandwich-type solid-phase enzyme immunoassay (EIA) for carcinoembryonic antigen (CEA) was established by using two selected monoclonal antibodies (MAbs). One MAb, F82-61, which is immobilized on polystyrene beads, reacts with an epitope present on the N-terminal domain (N) of the CEA molecule and the other, F11-...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(93)90388-n

    authors: Nagasaki H,Watanabe S,Kuroki M,Matsumoto Y,Murakami M,Omoda N,Kondo N,Jinnai H,Takaoka H,Matsuoka Y

    更新日期:1993-06-18 00:00:00

  • Detection of human histocompatibility (HLA) antigens with an indirect rosette microassay.

    abstract::An indirect rosette assay which utilizes erythrocytes coupled with purified antiimmunoglobulin (Ig) antibodies was modified into a microassay for detecting HLA allo-and xenoantibodies. The test, which is performed in microtiter plates, is specific, reproducible and can handle large numbers of samples. As an inhibition...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(79)90059-0

    authors: Indiveri F,Wilson BS,Pellegrino MA,Ferrone S

    更新日期:1979-01-01 00:00:00

  • Establishment of an anti-hepatitis C virus IgG avidity test for dried serum/plasma spots.

    abstract::Monitoring recency of infection helps to identify current transmission in vulnerable populations for effective disease control. We have established an in-house avidity based hepatitis C virus (HCV) recency assay based on the Monolisa Anti-HCV PLUS Version 3 ELISA kit for use of dried serum/plasma spots (DS/PS) in orde...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2020.112744

    authors: Eshetu A,Hauser A,An der Heiden M,Schmidt D,Meixenberger K,Ross S,Obermeier M,Ehret R,Bock CT,Bartmeyer B,Bremer V,Bannert N

    更新日期:2020-04-01 00:00:00

  • Assay of the human leukocyte enzymes myeloperoxidase and eosinophil peroxidase.

    abstract::Conditions were optimized for measuring the activity of myeloperoxidase (MPO) and the eosinophil peroxidase (EPO) with tetramethylbenzidine (TMB) as the substrate. Detergents caused a small increase in the measured activity of the purified enzymes and were required when isolated neutrophils or eosinophils were assayed...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(90)90020-v

    authors: Bozeman PM,Learn DB,Thomas EL

    更新日期:1990-01-24 00:00:00

  • High affinity anti-Internalin B VHH antibody fragments isolated from naturally and artificially immunized repertoires.

    abstract::The need for rapid and easy technologies for the detection of food-borne and environmental pathogens is essential for safeguarding the health of populations. Furthermore, distribution of tainted food and water can have consequences which can affect whole economies. Antibodies and antibody fragments have been historica...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2014.10.009

    authors: Gene RW,Kumaran J,Aroche C,van Faassen H,Hall JC,MacKenzie CR,Arbabi-Ghahroudi M

    更新日期:2015-01-01 00:00:00

  • Solid-phase radioimmunoassay of herpes simplex virus IgG and IgM antibodies.

    abstract::A solid-phase radioimmunoassay for detection of herpes simplex virus-specific IgG and IgM antibodies in human serum specimens is presented. Virus antigen is adsorbed on polystyrene balls and antibodies which attach to the antigen are detected by 125I-labeled antihuman-gamma or antihuman-mu immunoglobulins. A total of ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(77)90008-4

    authors: Kalimo KO,Ziola BR,Viljanen MK,Granfors K,Toivanen P

    更新日期:1977-01-01 00:00:00

  • Detection and quantitation of eosinophils in the murine respiratory tract by flow cytometry.

    abstract::Traditionally, the identification and quantification of eosinophils in inflammatory tissues and exudates has been primarily based upon morphologic criteria and manual counting. In this study, we describe a new flow cytometry-based assay to enumerate eosinophils present in murine bronchoalveolar lavage fluid (BAL) and ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2007.07.011

    authors: Stevens WW,Kim TS,Pujanauski LM,Hao X,Braciale TJ

    更新日期:2007-10-31 00:00:00

  • Simple immunoassays for semiquantitative determination of calmodulin (CaM) and anti-CaM. Applications to affinity column chromatography of anti-CaM antibodies and estimation of CaM in synaptosomal membranes from rat cerebral cortex.

    abstract::Dot-immunobinding assay for anti-calmodulin (CaM), and immunoblot assay for CaM have become feasible by proper choice of a fixative, i.e., formaldehyde vapor. The protocol for these simple and convenient immunological procedures is presented. Dot-immunobinding assay could be accomplished in 3 h, and immunoblot assay i...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(89)90089-6

    authors: Natsukari N,Ohta H,Fujita M

    更新日期:1989-12-20 00:00:00

  • Rapid simultaneous assessment of neutrophil superoxide generation and lysosomal enzyme release.

    abstract::A rapid method for the simultaneous measurement of neutrophil superoxide generation and beta-glucuronidase release is described. Assay of beta-glucuronidase using a fluorescent substrate is shown to be valid in the presence of reduced or unreduced ferricytochrome C, a prerequisite for the simultaneous assessment of th...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(87)90191-8

    authors: Mandell BF,Ohliger D,Rella J

    更新日期:1987-06-26 00:00:00

  • Detection and activation of human Valpha24+ natural killer T cells using alpha-galactosyl ceramide-pulsed dendritic cells.

    abstract::Human CD1d-restricted natural killer T (NKT) cells, which are postulated to regulate the immune response in several clinical settings, can be activated by alpha-galactosylceramide (alpha-GalCer) presented by CD1d molecules on antigen presenting cells (APCs). Simple methods to quantify NKT function in fresh blood will ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(02)00497-0

    authors: Fujii S,Shimizu K,Steinman RM,Dhodapkar MV

    更新日期:2003-01-15 00:00:00

  • Enumeration of t rosette-forming cell population in rabbit peripheral blood using human, sheep, guinea-pig, rat, mouse and chicken red blood cells under different experimental conditions.

    abstract::Attempts were made to estimate peripheral T-lymphocytes in rabbits by their ability to form rosettes with sheep, human, guinea-pig, rat, mouse and chicken RBC. The reaction was studied under different conditions of pH and temperature. The test was also carried out in the presence or absence of glutaraldehyde. With she...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(77)90165-x

    authors: Vakharia DD,Vakharia MR,Rao SS

    更新日期:1977-01-01 00:00:00

  • Fluorescent proteins: powerful tools in phagocyte biology.

    abstract::Phagocyte functions such as chemotaxis and phagocytosis involve the rapid and transient development of cellular polarity. Study of this highly complex spatial and temporal cellular remodelling has been limited by the static nature of immunofluorescence and immunogold microscopy and because biochemical techniques are n...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章,评审

    doi:10.1016/s0022-1759(99)00155-6

    authors: Bajno L,Grinstein S

    更新日期:1999-12-17 00:00:00

  • Structural diversity of antibody catalysts.

    abstract::The structural diversity of the immune response may be considerably restricted by the structure of the hapten used to elicit catalytic antibodies. The ligand-binding mode and the shapes of the binding pockets of hydrolytic antibodies induced to different transition-state analogs that contain an unsubstituted arylphosp...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章,评审

    doi:10.1016/s0022-1759(02)00240-5

    authors: Golinelli-Pimpaneau B

    更新日期:2002-11-01 00:00:00

  • Increased immunogenicity of a non-amphipathic protein (BSA) after inclusion into iscoms.

    abstract::Bovine serum albumin (BSA) was used as a non-amphipathic model protein to be included into iscoms. Pretreatment at an acidic pH (2.5) was used to reveal hydrophobic regions, after which BSA could be integrated. In immunization experiments in mice the BSA iscoms induced long lasting and considerably higher serum antibo...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(90)90208-d

    authors: Morein B,Ekström J,Lövgren K

    更新日期:1990-04-17 00:00:00

  • A new model for the estimation of cell proliferation dynamics using CFSE data.

    abstract::CFSE analysis of a proliferating cell population is a popular tool for the study of cell division and divisionlinked changes in cell behavior. Recently Banks et al. (2011), Luzyanina et al. (2009), Luzyanina et al. (2007), a partial differential equation (PDE) model to describe lymphocyte dynamics in a CFSE proliferat...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2011.08.014

    authors: Banks HT,Sutton KL,Thompson WC,Bocharov G,Doumic M,Schenkel T,Argilaguet J,Giest S,Peligero C,Meyerhans A

    更新日期:2011-10-28 00:00:00

  • Chimaeric protein A/protein G and protein G/alkaline phosphatase as reporter molecules.

    abstract::The IgG binding domains of staphylococcal protein A and streptococcal protein G were expressed as a chimaera using the pGEX vector which has been advocated because its fusion proteins tend to be soluble and easily isolated on immobilised glutathione. This chimaera was soluble and abundant (yield = 18 mg/l of bacterial...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(92)90087-a

    authors: Sun S,Lew AM

    更新日期:1992-07-31 00:00:00

  • An oscillating bubble chamber for laboratory scale production of monoclonal antibodies as an alternative to ascitic tumours.

    abstract::A simple roller bottle was constructed to house three dialysis tubes, each with a capacity of 75 ml. Cells were grown inside the dialysis tubing, which was immersed in ordinary DMEM medium without serum supplement. Cultures of hybridomas at medium or low density (2 X 10(5) cells/ml) could be expanded directly in the d...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(92)90046-v

    authors: Pannell R,Milstein C

    更新日期:1992-01-21 00:00:00

  • A solid-phase enzyme immunoassay for anti-acetylcholine receptor antibody in myasthenia gravis patients.

    abstract::A solid-phase enzyme immunoassay for the measurement of anti-acetylcholine receptor antibodies in the sera of patients with myasthenia gravis is reported. Sufficient amounts of acetylcholine receptor for the sensitive detection of anti-acetylcholine receptor antibody were directly fixed to Costar serocluster 96-well E...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(84)90401-0

    authors: Kobayashi N,Sugita H,Terada E,Ghoda A,Okudaira H,Ogita T,Miyamoto T

    更新日期:1984-10-26 00:00:00

  • Serum depletion, multidrug resistance and fluorescent probes: methodological implications in free radicals evaluation.

    abstract::Intracellular probes used for oxidative burst evaluation could be a substrate of the multidrug resistance proteins (MDR), which may cause misinterpretation of experimental data. We aimed to study the effect of the culture condition and of the MDR-interfering antioxidant quercetin on free radical measurement in serum d...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2013.12.009

    authors: Peluso I,Romanelli L,Spagnuolo S,Manafikhi H,Palmery M

    更新日期:2014-03-01 00:00:00

  • The concentrations of glutamine and ammonia in commercially available cell culture media.

    abstract::The amino acid glutamine is an essential nutrient for cells in culture. In aqueous solutions such as liquid culture media, glutamine spontaneously decomposes into ammonia. In this study, we examined the toxicity of ammonia for two different cell lines. In mouse hybridoma cell cultures, viable cell counts were reduced ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(93)90331-z

    authors: Heeneman S,Deutz NE,Buurman WA

    更新日期:1993-11-05 00:00:00

  • An ELISA method for detecting antibodies to the T cell antigen receptor.

    abstract::An ELISA method for the detection of monoclonal antibodies (MAb) to the T3-T cell antigen receptor (TCR) complex was devised. The T3-TCR complex was solubilised using digitonin and a rat anti-T3 MAb (Campath 3) was used to bind it to an ELISA plate. Normal rat serum was used to block cross-reactivity between the rat M...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(88)90280-3

    authors: Clark DM,Boylston AW

    更新日期:1988-01-21 00:00:00

  • Use of protein A to remove immunoglobulins from serum in hybridoma culture media.

    abstract::The levels of protein A-reactive immunoglobulin (PA-Ig) in foetal bovine serum were measured in commercial batches. For tissue culture media incorporating 10% foetal bovine serum, the levels of bovine PA-Ig were of a similar order to those of mouse monoclonal antibodies produced by hybridomas grown in such media. The ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(83)90332-0

    authors: Underwood PA,Kelly JF,Harman DF,MacMillan HM

    更新日期:1983-05-27 00:00:00

  • Characterization of monoclonal antibodies to 2,4-dichlorophenoxyacetic acid using a piezoelectric quartz crystal microbalance in solution.

    abstract::Piezoelectric quartz crystals (resonance frequency 10 MHz) were used for an investigation of the immunochemical reaction between 2,4-dichlorophenoxyacetic acid (2,4-D) herbicide and several monoclonal antibodies prepared against 2,4-D. The herbicide was immobilized on the gold electrodes of the crystals silanized with...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(94)90356-5

    authors: Skládal P,Minunni M,Mascini M,Kolár V,Fránek M

    更新日期:1994-11-10 00:00:00

  • A simple method for coating native polysaccharides onto nitrocellulose.

    abstract::A method for coating native, non-derivatized, polysaccharide (PS) onto nitrocellulose (NC) for identifying PS-specific antibodies has been developed. The new feature of this method is that PS molecules are vacuum filtered onto NC in their native state by devices that can accommodate NC of different sizes and shapes. P...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(91)90032-b

    authors: Feng SH,Rubinstein LJ,Stein KE

    更新日期:1991-03-21 00:00:00

  • Hematological response of rabbits to chronic, repetitive, severe bleedings for the production of antisera.

    abstract::A study was undertaken to determine whether large amounts of blood (antiserum) could be rapidly removed from rabbits over a two-month period using a simple suction technique. It was found that half a blood volume could be readily removed each week (over 900 ml/rabbit/54 days) without a single fatality. The rabbits eff...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(78)90081-9

    authors: Nerenberg ST,Zedler P,Prasad R,Biskup NS,Pedersen L

    更新日期:1978-01-01 00:00:00