Applied radioactivity in radiation synovectomy with [188Re]rhenium sulfide suspension.

Abstract:

BACKGROUND:Early experience demonstrated absorbed dose in radiation synovectomy is about 100 Gy. For reaching this dose, the applied radioactivity should be calculated. METHOD:Twenty-nine synovitic models of rabbit were treated by intra-articular injection of [(188)Re]rhenium sulfide and histological changes of synovium and cartilage were examined. The applied radioactivity was calculated by method of absorbed dose factor. In clinical, eleven haemophilic patients with haemarthrosis were performed radiation synovectomy with treated [(188)Re]rhenium sulfide. The synovial thickness was evaluated by MR and its value was used to calculate the applied radioactivity. After radiation synovectomy, all patients were followed up by synovial thickness, regional inflammation, and clinical course including bleeding frequency. RESULTS:In rabbit models, the synovitic membrane can be eliminated by calculated radioactivity as planed without damaging the joint cartilage. In patients study, all patients exhibited significant reductions in synovial thickness and inflammation after radiation synovectomy with the planed radioactivities of [(188)Re]rhenium sulfide. Post-procedure bleeding frequency reduction in excellent and good reached to 63.6% by 18 months. In the cases of joint bleeding, the need for antihaemophilic factor treatment decreased immensely. Most of the recurrent episodes of bleeding were mild, subsiding with local means. CONCLUSION:The applied radioactivity in radiation synovectomy could be calculated according to thickness of inflamed synovium. Further study including comparison therapeutic results from calculated individual activities with results from fixed activities and long-term follow-up is warranted.

journal_name

Nucl Med Commun

authors

Li P,Yu J,Chen G,Jiang X,Tang Z,Chen S,Jiang L,Tang L,Yin D

doi

10.1097/00006231-200608000-00002

subject

Has Abstract

pub_date

2006-08-01 00:00:00

pages

603-9

issue

8

eissn

0143-3636

issn

1473-5628

pii

00006231-200608000-00002

journal_volume

27

pub_type

临床试验,杂志文章
  • Comparison of treatment efficacy 1 and 2 years after thyroid remnant ablation with 1110 versus 5550 MBq of iodine-131 in patients with intermediate-risk differentiated thyroid cancer.

    abstract:BACKGROUND:Radioiodine ablation may be associated with improved survival in patients with intermediate-risk follicular cell differentiated thyroid cancer (FCDTC). The aim of this study was to compare ablation efficacy of 1110 versus 5500 MBq of iodine-131 (I) in FCDTC patients with intermediate risk. METHODS:Thirty-ni...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000730

    authors: Aghaei A,Ayati N,Shafiei S,Abbasi B,Zakavi SR

    更新日期:2017-11-01 00:00:00

  • Radiation alarm at an airport after radioiodine therapy.

    abstract:BACKGROUND:Screening for radioactive material at borders may become more widely introduced in order to prevent illegal transport. All the alarms at Vienna airport so far have been due to recent applications of radionuclides for medical reasons. METHODS:We report a patient who unexpectedly experienced this problem afte...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200501000-00011

    authors: Sinzinger H,Aiginger P,Neumann I,Havlik E

    更新日期:2005-01-01 00:00:00

  • Ischaemic related transitory left ventricular dysfunction in 201Tl gated SPECT.

    abstract:AIM:To report our data concerning the changes in post-stress and at-rest left ventricular ejection fraction and ventricular volumes in patients with thallium gated SPECT. METHODS:Post-stress and at-rest thallium gated SPECT was performed in 629 consecutive patients; left ventricular ejection fraction (LVEF), left vent...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.mnm.0000167648.29853.93

    authors: del Val Gómez M,Gallardo FG,San Martín MA,Garcia A,Terol I

    更新日期:2005-07-01 00:00:00

  • PET imaging in glioma: techniques and current evidence.

    abstract::PET holds potential to provide additional information about tumour metabolic processes, which could aid brain tumour differential diagnosis, grading, molecular subtyping and/or the distinction of therapy effects from disease recurrence. This review discusses PET techniques currently in use for untreated and treated gl...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0000000000000914

    authors: Mansoor NM,Thust S,Militano V,Fraioli F

    更新日期:2018-12-01 00:00:00

  • Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation.

    abstract:OBJECTIVE:To evaluate the diagnostic value of function volume/morphological volume ratio calculated from ventilation/perfusion single-photon emission computed tomography/computed tomography in distinguishing the lungs with bronchiolitis obliterans syndrome (BOS) from the lungs without this syndrome after lung transplan...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001021

    authors: Nakashima M,Shinya T,Oto T,Okawa T,Takeda Y

    更新日期:2019-07-01 00:00:00

  • Evaluation of somatostatin receptors in large cell pulmonary neuroendocrine carcinoma with 99mTc-EDDA/HYNIC-TOC scintigraphy.

    abstract:OBJECTIVE:Large cell pulmonary neuroendocrine carcinoma (LCNEC) is a poorly differentiated and high-grade neoplasm. It is positioned between an atypical carcinoid and small cell neuroendocrine carcinoma of the lung in a distinct family of pulmonary neuroendocrine tumors. The aim of our study was to detect somatostatin ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834508b3

    authors: Nocuń A,Chrapko B,Gołębiewska R,Stefaniak B,Czekajska-Chehab E

    更新日期:2011-06-01 00:00:00

  • How to assess background activity: introducing a histogram-based analysis as a first step for accurate one-step PET quantification.

    abstract::Many common PET segmentation methods for malignant lesions use surrounding background activity as a reference. To date, background has to be measured by drawing a second volume of interest (VOI) in nearby, undiseased tissue. This is time consuming as two VOIs have to be determined for each lesion. The aim of our study...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000045

    authors: Burger IA,Vargas HA,Beattie BJ,Goldman DA,Zheng J,Larson SM,Humm JL,Schmidtlein CR

    更新日期:2014-03-01 00:00:00

  • A technique for lung ventilation-perfusion SPECT in neonates and infants.

    abstract:BACKGROUND:Single photon emission tomography (SPECT) of the lung is a well-established non-invasive technique for quantitative assessment of regional lung ventilation and perfusion distribution in children and in adults. However, its application in neonates as well as infants has been scarce because of several practica...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f25905

    authors: Sánchez-Crespo A,Rohdin M,Carlsson C,Bergström SE,Larsson SA,Jacobsson H,Lindahl S,Jonsson B

    更新日期:2008-02-01 00:00:00

  • The value of syringe shields in a nuclear medicine department.

    abstract::The radiation dose to the pulp of both index fingers has been measured in a radiopharmacy supplying 11 000 patient doses a year, in a hospital dispensary (4500 doses a year) and in its injection area. Tungsten syringe shields were used for one week and not used during the other week. In the radiopharmacy and the dispe...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198508000-00004

    authors: Harding LK,Hesslewood S,Ghose SK,Thomson WH

    更新日期:1985-08-01 00:00:00

  • Reproducibility and repeatability of differential renal function in 4-week-old piglets.

    abstract:BACKGROUND:Congenital obstructive renal disease often requires a decision early in the child's life on whether or not surgery is required. Differential renal function (DRF) calculated from the renogram provides important information for the correct decision in this process. A recent publication cast doubt as to the rel...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f20e1f

    authors: Dissing TH,Eskild-Jensen A,Pedersen M,Anderson PJ,Rittig N,Frøkiaer J,Gordon I

    更新日期:2008-01-01 00:00:00

  • Image-derived input function in PET brain studies: blood-based methods are resistant to motion artifacts.

    abstract:BACKGROUND:Image-derived input function (IDIF) from carotid arteries is an elegant alternative to full arterial blood sampling for brain PET studies. However, a recent study using blood-free IDIFs found that this method is particularly vulnerable to patient motion. The present study used both simulated and clinical [11...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328356185c

    authors: Zanotti-Fregonara P,Liow JS,Comtat C,Zoghbi SS,Zhang Y,Pike VW,Fujita M,Innis RB

    更新日期:2012-09-01 00:00:00

  • Preliminary clinical investigation of 99mTc-methoxyisobutylisonitrile washout rate in hypertrophic cardiomyopathy.

    abstract:OBJECTIVE:The aim of this study was to investigate the changes in early and late washout rates of 99mTc-methoxyisobutylisonitrile (MIBI) in hypertrophic cardiomyopathy (HCM), and to analyze the relationships between early and late washout rates and the hypertrophic thickness of left ventricular (LV) wall. METHODS:The ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283009f36

    authors: Sun M,Li Y,Li N,Liu H,Yin Y,Li D

    更新日期:2008-08-01 00:00:00

  • Spontaneous variability of left ventricular ejection fraction assessed with the Cardioscint.

    abstract::A miniature, non-imaging caesium iodide nuclear probe optically coupled to a photodiode (the 'Cardioscint') has been developed which, in conjunction with a modified personal computer, is capable of continuous on-line monitoring of left ventricular function and ST-segment level at the bedside. The purpose of this study...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199205000-00004

    authors: Broadhurst P,Liu XJ,Cashman PM,Raftery EB,Lahiri A

    更新日期:1992-05-01 00:00:00

  • Peripheral lymphovenous communication in lymphoedema.

    abstract:AIM:To investigate whether in lower extremity lymphoedema, lymph proteins enter blood before they do the thoracic duct. METHODS:Retrospective analysis of routine lymphoscintigraphy in 69 adults imaged at 5, 45 and 150 min following bilateral subcutaneous web space injection of Tc-nanocolloid was carried out. Regions o...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32835313d4

    authors: Stamp GF,Peters AM

    更新日期:2012-07-01 00:00:00

  • The impact of radiopharmaceutical particle size on the visualization and identification of sentinel nodes in breast cancer.

    abstract:OBJECTIVES:The aim of this study was to compare the success rate in lymphatic mapping and sentinel node biopsy in breast cancer using two radiopharmaceuticals. METHODS:The study included 119 breast cancer patients who underwent lymphoscintigraphy after a single intratumoral injection of 99mTc-labelled human albumin co...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200403000-00004

    authors: Leidenius MH,Leppänen EA,Krogerus LA,Smitten KA

    更新日期:2004-03-01 00:00:00

  • Role of SUV(max) obtained by 18F-FDG PET/CT in patients with a solitary pancreatic lesion: predicting malignant potential and proliferation.

    abstract:OBJECTIVES:Maximum standardized uptake value (SUV(max)) is a marker of tumor glucose metabolism detected by [(18)F]-fluorodeoxyglucose ((18)F-FDG) PET/computed tomography (PET/CT) and reflects tumor aggressiveness. The aim of the study was to evaluate the value of SUV(max) in differentiating benign from malignant solit...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328360668a

    authors: Hu SL,Yang ZY,Zhou ZR,Yu XJ,Ping B,Zhang YJ

    更新日期:2013-06-01 00:00:00

  • Scintigraphic evaluation of renoprotective effects of coenzyme Q10 in a rat renal ischemia-reperfusion injury.

    abstract:PURPOSE:Renal ischemia-reperfusion injury (RIRI) may occur secondary to several reasons leading to renal failure. Coenzyme-Q10 (CoQ10) is a well-known antioxidant. However, the effects CoQ10 against RIRI have not been evaluated. Our aim was to evaluate protective effects of CoQ10 to renal ischemia-reperfusion by bioche...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001070

    authors: Akbulut A,Keseroglu BB,Koca G,Yuceturk CN,Ozgur BC,Surer H,Ogus E,Yumuşak N,Karakaya J,Korkmaz M

    更新日期:2019-10-01 00:00:00

  • Myocardial 123I-MIBG kinetics in acutely hypothyroid patients with differentiated thyroid carcinoma.

    abstract::Marked changes in cardiac function have been noted in patients with hyperthyroidism or hypothyroidism due both to changes in sympathetic system function and to biochemical modifications of myocardial tissue. Metaiodobenzylguanidine (MIBG), an analogue of norepinephrine, can be used to evaluate myocardial sympathetic t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199908000-00006

    authors: Maini CL,Tofani A,Sciuto R,Ferraironi A,Festa A,Rea S

    更新日期:1999-08-01 00:00:00

  • Observation of changes in peripheral T-lymphocyte subsets by flow cytometry in patients with liver cancer treated with radioimmunotherapy.

    abstract::An analysis of lymphocyte subsets was performed in 24 patients with surgically verified unresectable hepatocellular carcinoma (HCC). In all cases, the hepatic artery was cannulated and ligated and a single dose of 131I-Hepama-1 monoclonal antibody (MAb) was infused through a hepatic artery catheter. Blood samples were...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199505000-00010

    authors: Zeng ZC,Tang ZY,Liu KD,Yu YQ,Yang BH,Cai XJ,Xie H,Cao SL

    更新日期:1995-05-01 00:00:00

  • Optimized robust plasma sampling for glomerular filtration rate studies.

    abstract::In the presence of abnormal fluid collection (e.g. ascites), the measurement of glomerular filtration rate (GFR) based on a small number (1-4) of plasma samples fails. This study investigated how a few samples will allow adequate characterization of plasma clearance to give a robust and accurate GFR measurement. A tot...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328356fb6d

    authors: Murray AW,Gannon MA,Barnfield MC,Waller ML

    更新日期:2012-09-01 00:00:00

  • FDG-PET/CT for diagnosis of primary ovarian cancer.

    abstract:BACKGROUND AND AIM:To evaluate the diagnostic value of integrated 18F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) to discriminate malignant from benign ovarian tumors. METHODS:One hundred and eight women suspected of having ovarian cancer underwent preoperative FDG-PET/CT sca...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328345b339

    authors: Kitajima K,Suzuki K,Senda M,Kita M,Nakamoto Y,Onishi Y,Maeda T,Yoshikawa T,Ohno Y,Sugimura K

    更新日期:2011-07-01 00:00:00

  • In vivo kinetics of 123I-labelled insulin: studies in normal subjects and patients with diabetes mellitus.

    abstract::Radioactive tracer techniques using 131I- and 125I-insulin have been applied to study insulin metabolism. A simple method to label human insulin with 123I to a high specific activity is described. We have used this radiotracer to study insulin kinetics in vivo in normal subjects and in two groups of diabetic patients....

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198710000-00003

    authors: Sinclair AJ,Signore A,Bomanji J,Britton KE,Pozzilli P,Gale EA

    更新日期:1987-10-01 00:00:00

  • Estimation of ascitic fluid volume using 99Tcm labelled macroaggregated albumin.

    abstract::We have assessed the usefulness of a radionuclide dilution method for estimation of ascitic fluid volume. 99Tc(m) macroaggregated albumin (10 MBq) was injected into the peritoneal fluid. Multiple samples were taken using a trocath peritoneal dialysis catheter over a 4-h period. Blood samples were taken at the same tim...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200012000-00009

    authors: Notghi A,Williams NR,Kehoe S,Smith NB,Harding LK

    更新日期:2000-12-01 00:00:00

  • Normal bone and soft tissue distribution of fluorine-18-sodium fluoride and artifacts on 18F-NaF PET/CT bone scan: a pictorial review.

    abstract::Fluorine-18-sodium fluoride (F-NaF) PET/CT is a relatively new and high-resolution bone imaging modality. Since the use of F-NaF PET/CT has been increasing, it is important to accurately assess the images and be aware of normal distribution and major artifacts. In this pictorial review article, we will describe the no...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0000000000000720

    authors: Sarikaya I,Elgazzar AH,Sarikaya A,Alfeeli M

    更新日期:2017-10-01 00:00:00

  • Phase I/II clinical trial of the humanized anti-EGF-r monoclonal antibody h-R3 labelled with 99mTc in patients with tumour of epithelial origin.

    abstract:AIM:To evaluate the biodistribution, internal radiation dosimetry and toxicity of the humanized MAb h-R3 labelled with Tc in humans. METHODS:Twenty-five patients with suspected epithelial-derived tumours were included in this study and divided into two groups: group I consisted of 10 patients who received 3 mg/1110 MB...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200512000-00002

    authors: Torres LA,Perera A,Batista JF,Hernández A,Crombet T,Ramos M,Neninger E,Pérez M,Sánchez EL,Romero S,Aguilar V,Coca MA,Iznaga-Escobar N

    更新日期:2005-12-01 00:00:00

  • Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

    abstract:INTRODUCTION:An image-processing algorithm (AUTOROI) has been developed to totally automatically (or with manual assistance) detect whole-kidney contours and generate renal regions of interest (ROI) for the extraction of the quantitative measurements used in the interpretation of Tc-mercaptoacetyltriglycine (Tc-MAG3) r...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283362aa3

    authors: Garcia EV,Folks R,Pak S,Taylor A

    更新日期:2010-05-01 00:00:00

  • 99mTc carbonyl t-butyl isonitrile: a potential new agent for myocardial perfusion imaging.

    abstract:OBJECTIVE:The recent development of mixed ligand complexes using a 99mTc tricarbonyl synthon has prompted us to revisit the first generation product, 99mTc-t-butyl isonitrile (TBI), for possible myocardial imaging after modification of the 99mTc core to a mixed ligand core of carbonyl and t-butyl isonitrile. The easy a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200502000-00013

    authors: Kothari KK,Satpati D,Joshi S,Venkatesh M,Ramamoorthy N,Pillai MR

    更新日期:2005-02-01 00:00:00

  • Morphine-augmented hepatobiliary scintigraphy: a meta-analysis.

    abstract::The aim of this study was to compare the sensitivity and specificity of morphine-augmented hepatobiliary scintigraphy (MA-HBS) with that of conventional hepatobiliary scintigraphy (C-HBS) for acute cholecystitis. The results of most MA-HBS studies cannot be compared with C-HBS estimates, since articles describing C-HB...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199512000-00013

    authors: Cabana MD,Alavi A,Berlin JA,Shea JA,Kim CK,Williams SV

    更新日期:1995-12-01 00:00:00

  • Radionuclide limb blood flow in peripheral vascular disease: a review of 1100 measurements.

    abstract::Radionuclide limb blood flow measurements using 99Tcm-labelled human serum albumin and a gamma camera have been performed on normal volunteers and on patients with suspected or confirmed peripheral arterial disease. The normal range of flow was found to be 10.0-22.3 ml per 100 ml tissue per min. Flow in the symptomati...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199110000-00003

    authors: Parkin A,Robinson PJ,Martinez D,Wilkinson D,Kester RC

    更新日期:1991-10-01 00:00:00

  • Immediate 201Tl reinjection: an alternative approach in myocardial perfusion scintigraphy? A comparison with contrast angiographic findings.

    abstract::Thallium-201 (201Tl) stress-redistribution/reinjection imaging provides a reliable diagnostic approach in patients evaluated for myocardial ischaemia. Immediate reinjection of 201Tl after completing the stress images followed by imaging 1 h later shortens the investigation time to 2.5 h and may provide a novel approac...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:

    authors: van Eck-Smit BL,van der Wall EE,Zwinderman AH,Pauwels EK

    更新日期:1995-10-01 00:00:00