Morphine-augmented hepatobiliary scintigraphy: a meta-analysis.

Abstract:

:The aim of this study was to compare the sensitivity and specificity of morphine-augmented hepatobiliary scintigraphy (MA-HBS) with that of conventional hepatobiliary scintigraphy (C-HBS) for acute cholecystitis. The results of most MA-HBS studies cannot be compared with C-HBS estimates, since articles describing C-HBS often include non-candidates for MA-HBS. However, using meta-analytic techniques to combine data from eligible studies (4 for C-HBS and 5 for MA-HBS), the specificity of MA-HBS (0.84; 95% CI = 0.75-0.94) was significantly greater (P = 0.008) than that of C-HBS (0.68; 95% CI = 0.61-0.75); there were no differences in sensitivity (MA-HBS; 0.96, 95% CI = 0.92-0.99; C-HBS: 0.97, 95% CI = 0.97-0.99).

journal_name

Nucl Med Commun

authors

Cabana MD,Alavi A,Berlin JA,Shea JA,Kim CK,Williams SV

doi

10.1097/00006231-199512000-00013

subject

Has Abstract

pub_date

1995-12-01 00:00:00

pages

1068-71

issue

12

eissn

0143-3636

issn

1473-5628

journal_volume

16

pub_type

杂志文章
  • Time course of thyroglobulin autoantibodies in patients with differentiated thyroid carcinoma after radioiodine therapy.

    abstract::The time course of thyroglobulin (Tg) was monitored in patients with differentiated thyroid carcinoma after ablative therapy (thyroidectomy + 131I-treatment) with particular respect to endogeneous antibodies (Tg-ABs). In 232 patients (196 without Tg-ABs, 36 with Tg-ABs at the time of treatment) a sensitivity of 88% (a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198405000-00003

    authors: Moser E,Braun S,Kirsch CM,Kleinhans E,Buell U

    更新日期:1984-05-01 00:00:00

  • Detection of norepinephrine distribution in rats with adrenal medulla autotransplants using 125I-meta-iodobenzyl guanidine.

    abstract::The viability of autologous adrenal medullary transplants was evaluated using 125I-meta-iodobenzyl guanidine (MIBG), an adrenal medullary scanning agent. Bilateral cavities in the caudate nuclei were made stereotaxically in Wistar rats. One week later, the left adrenal medulla was resected by microsurgery, followed by...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199409000-00015

    authors: Shinoda M,Suzuki Y,Oi S,Tsugane R,Sato O

    更新日期:1994-09-01 00:00:00

  • Is computer-aided interpretation of 99Tcm-HMPAO leukocyte scans better than the naked eye?

    abstract::In order to compare visual interpretation of inflammation detected by leukocyte scintigraphy with that of different computer-aided quantification methods, 34 patients (25 with ulcerative colitis and 9 with endoscopically verified non-inflamed colonic mucosa), were investigated using 99Tcm-hexamethylpropyleneamine oxim...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199504000-00161

    authors: Almer S,Peters AM,Ekberg S,Franzén L,Granerus G,Ström M

    更新日期:1995-04-01 00:00:00

  • Immunotechnological trends in radioimmunotargeting: from 'magic bullet' to 'smart bomb'.

    abstract::The impact of recent advances in the chemical and genetic engineering manipulations of antibodies on radioimmunotargeting is reviewed both in relation to radioimmunoscintigraphy and radioimmunotherapy. The resulting trends are: (1) the linking of parts of the mouse/rat and human antibody molecule; (2) the creation of ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:

    authors: Hazra DK,Britton KE,Lahiri VL,Gupta AK,Khanna P,Saran S

    更新日期:1995-02-01 00:00:00

  • Molecular subtypes of invasive breast cancer: correlation between PET/computed tomography and MRI findings.

    abstract:OBJECTIVE:The aim of the study was to investigate the diagnostic value of fluorodeoxyglucose-18 (FDG)-PET/computed tomography (CT) and MRI parameters in determining the molecular subtypes of invasive breast cancer. METHODS:Data from 55 primary invasive breast cancer masses in 51 female patients who underwent pre-treat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001220

    authors: Akin M,Orguc S,Aras F,Kandiloglu AR

    更新日期:2020-08-01 00:00:00

  • Dual-time 18F-FDG PET/CT for the detection of liver metastases in breast cancer.

    abstract:OBJECTIVE:The aim was to investigate the diagnostic potential of dual-time-point F-fluorodeoxyglucose positron emission tomography/computed tomography (F-FDG PET/CT) in patients with breast cancer with known or suspected liver metastases and to assess its clinical value on clinical management. PATIENTS AND METHODS:A t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000918

    authors: Annovazzi A,Rea S,Vici P,Fabi A,Sciuto R

    更新日期:2018-12-01 00:00:00

  • Detection of CBF deficits in neuropsychiatric disorders by an expert system: a 99Tcm-HMPAO brain SPET study using automated image registration.

    abstract::The aims of this study were to develop an objective method for assessing rCBF deficits using a statistical image analysis protocol and to validate its effective use in clinical practice. 99Tcm-HMPAO brain SPET images were acquired for 40 normal subjects, 10 patients with Alzheimer's disease and 10 patients with depres...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199901000-00006

    authors: Imran MB,Kawashima R,Sato K,Kinomura S,Ono S,Qureshy A,Fukuda H

    更新日期:1999-01-01 00:00:00

  • Influence of statistical noise on the determination of the single kidney 99Tcm-DTPA clearance.

    abstract::Single kidney clearance can be obtained using the 99Tcm-DTPA complex and the scintillation camera. In order to evaluate the influence of statistical noise on the determination of the clearance, several non-noisy curves were constructed, simulating renal, background and precordial curves. Poisson noise was added to the...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198508000-00008

    authors: Piepsz A,Dobbeleir A,Ham HR

    更新日期:1985-08-01 00:00:00

  • Gender differences in brown adipose tissue-related brain functional networks: an 18F-FDG-PET study.

    abstract:PURPOSE:Thermogenesis of brown adipose tissue (BAT) is controlled by central modulating mechanisms, although changes in brain metabolism of BAT-positive subjects with different genders are still unclear. We hypothesized that changes in regional cerebral glucose metabolic activity were associated with BAT activities, an...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001190

    authors: Shao X,Chen Y,Shao X,Wang S,Wang S,Wang Y

    更新日期:2020-06-01 00:00:00

  • Early effects of intra-arterial chemotherapy in patients with brain tumours studied with PET: preliminary results.

    abstract::In ten patients with malignant gliomas the regional cerebral metabolic rate for glucose (rCMRGlc) was studied with positron emission tomography (PET) using 2-18F-deoxyglucose (18FDG) before and within 1 to 7 days after intra-arterial chemotherapy with the nitrosourea derivative ACNU (iaACNU). Three patients were studi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198911000-00002

    authors: Langen KJ,Roosen N,Kuwert T,Herzog H,Kiwit JC,Rota Kops E,Muzik O,Bock WJ,Feinendegen LE

    更新日期:1989-11-01 00:00:00

  • Relationship between myocardial counts and patient weight: adjusting the injected activity in myocardial perfusion scans.

    abstract::It is generally accepted that the quality of myocardial images deteriorates with increasing patient weight. This is attributed to a reduction of counts detected from the myocardium. In this paper we have looked at the count reduction in obese patients and suggest a workable algorithm to increase the injected activity ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00006231-200301000-00015

    authors: Notghi A,Williams N,Smith N,Goyle S,Harding LK

    更新日期:2003-01-01 00:00:00

  • Changes in septal regional ejection fraction early and late following coronary artery bypass grafting in patients without postoperative myocardial infarction.

    abstract::Changes in regional ejection fraction (rEF) of the interventricular septum following coronary artery bypass graft (CABG) surgery were examined using first-pass radionuclide ventriculography (RNVG) in patients without objective evidence of postoperative myocardial infarction (MI). One hundred and one patients had pre- ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Jacobson AF,Tow DE,Lapsley D,Khuri S

    更新日期:1992-10-01 00:00:00

  • Contribution of ¹¹¹In-pentetreotide SPECT/CT imaging to conventional somatostatin receptor scintigraphy in the detection of neuroendocrine tumours.

    abstract:AIM:The aim of the study was to assess the contribution of 111In-pentetreotide single-photon emission computed tomography/computed tomography (SPECT/CT) imaging to conventional somatostatin receptor scintigraphy (SRS) in terms of lesion characterization and localization in the detection of neuroendocrine tumours (NETs)...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000239

    authors: Sainz-Esteban A,Olmos R,González-Sagrado M,González ML,Ruiz MÁ,García-Talavera P,Gamazo C,Villanueva JG,Cobo A,de Luis D

    更新日期:2015-03-01 00:00:00

  • Imatinib mesylate for the treatment of gastrointestinal stromal tumours: best monitored with FDG PET.

    abstract:BACKGROUND:The new anti-cancer drug imatinib mesylate inhibits the tyrosine kinase growth factor receptor, c-KIT, and has shown spectacular activity in patients with gastrointestinal stromal tumours (GISTs). OBJECTIVE:To assess whether fluorodeoxyglucose positron emission tomography (FDG PET) is suitable for response ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200405000-00002

    authors: Jager PL,Gietema JA,van der Graaf WT

    更新日期:2004-05-01 00:00:00

  • Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time-activity curve for the tracer arterial input function.

    abstract:OBJECTIVE:In-vivo quantitative cerebral blood flow (CBF) measurement using positron emission tomography (PET) has typically employed invasive arterial blood sampling procedure to determine the arterial input function (AIF). The present study was performed to provide a non-invasive quantitative CBF measurement technique...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200510000-00009

    authors: Yee SH,Jerabek PA,Fox PT

    更新日期:2005-10-01 00:00:00

  • One year's clinical experience of 18F-FDG PET with a modified SPET camera using molecular coincidence detection.

    abstract::High-quality positron emission tomographic (PET) cameras are expensive and, therefore, not available in many centres. To allow access to clinical 18F-fluorodeoxyglucose (18F-FDG) PET, we began working with an ADAC Vertex camera equipped with a molecular coincidence detection (MCD) module in February 1997. Here we give...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199911000-00005

    authors: Erler H,Zaknun J,Donnemiller E,Bacher-Stier C,Oberladstätter M,Riccabona G,Moncayo R

    更新日期:1999-11-01 00:00:00

  • The relationship between 99Tc(m)-sestamibi uptake and ultrastructural cell types of thyroid tumours.

    abstract::Although several hypotheses have been suggested regarding the accumulation of 99Tc(m)-sestamibi in tumours, the exact uptake mechanism is still a matter of discussion. We investigated ultrastructural cell type of thyroid tumours by electron microscopy (EM) and compared them with uptake of 99Tc(m)-sestamibi. Thyroid sc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200101000-00006

    authors: Sarikaya A,Huseyinova G,Irfanoğlu ME,Erkmen N,Cermik TF,Berkarda S

    更新日期:2001-01-01 00:00:00

  • Comparison between low and high radioactive iodine (131I) reablation dose in patients with papillary thyroid cancer.

    abstract:AIM:The aim of this study was to assess ablation outcome after a second ablation dose and compare the ablation rate after low and high reablation doses of iodine-131 ((131)I) after failure of the first ablation with 3700 MBq. PATIENTS AND METHODS:The study included 81 patients with papillary thyroid cancer; they faile...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000233

    authors: M El-Refaei S,W Yassin S,Salman K,Al Munshy T,Al-Ezzi M,M Al-Sayed Y,Abd Elkareem Husseni M

    更新日期:2015-02-01 00:00:00

  • Incremental value of 99mTc-MDP hybrid SPECT/CT over planar scintigraphy and SPECT in avascular necrosis of the femoral head.

    abstract:OBJECTIVE:The aim of the study was to evaluate the incremental value of technetium-99m-methylene diphosphonate (99mTc-MDP) single-photon emission tomography/computed tomography (SPECT/CT) over planar bone scintigraphy (BS) and SPECT in the diagnosis of avascular necrosis (AVN) of the femoral head. MATERIALS AND METHOD...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000357

    authors: Agarwal KK,Mukherjee A,Sharma P,Bal C,Kumar R

    更新日期:2015-10-01 00:00:00

  • Evaluation of 99Tcm-teboroxime scintigraphy for the differentiation of reversible from fixed defects: comparison with 201T1 redistribution and reinjection imaging.

    abstract::The aim of this study was to compare 99Tcm-teboroxime and 201T1 myocardial studies with particular regard to the classification of perfusion defects as reversible or fixed. Twenty patients with a history of previous myocardial infarction and suspected effort ischaemia underwent exercise 201T1 scintigraphy with early (...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199307000-00002

    authors: Bisi G,Sciagrà R,Santoro GM,Zerauschek F,Fazzini PF

    更新日期:1993-07-01 00:00:00

  • Kinetic analysis of 99mTc-sestamibi evaluates the protective effects by ischaemic preconditioning on ischaemic myocardium in an isolated rabbit heart.

    abstract:OBJECTIVE:To analyse the kinetic changes of uptake, washout and retention of Tc-sestamibi in order to evaluate the protective effects and possible mechanism of ischaemic preconditioning and adenosine preconditioning on myocardium injured by ischaemia/reperfusion. METHODS:Isolated ischaemia/reperfusion rabbit heart mod...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f1781b

    authors: Liang J,Chen HL,Zhou Y,Xie M,Xu LM,Lin G

    更新日期:2007-11-01 00:00:00

  • Bone marrow scintigraphy in small cell carcinoma of the lung.

    abstract::A comparative study of bone marrow scintigraphy using 99Tcm-nanocolloid, conventional bone scintigraphy and bone marrow biopsy were performed in 35 patients with histologically proven small cell carcinoma of the lung to determine whether bone marrow scintigraphy has a role in the early detection of bone marrow metasta...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199401000-00006

    authors: Li DJ,Maughan TS,Miles KA,Wraight EP

    更新日期:1994-01-01 00:00:00

  • Pentavalent 99Tcm-DMSA imaging in patients with bone metastases.

    abstract::Pentavalent 99Tcm-dimercaptosuccinic acid (99Tcm-(V)DMSA) has an established role in imaging medullary thyroid carcinoma. There have been case reports of uptake in bone metastases. Our aims were to compare 99Tcm-(V)DMSA with 99Tcm-hydroxymethylene diphosphonate (99Tcm-HDP) in bone metastases, to assess its value in im...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199710000-00003

    authors: Lam AS,Kettle AG,O'Doherty MJ,Coakley AJ,Barrington SF,Blower PJ

    更新日期:1997-10-01 00:00:00

  • Differentiating dural metastases from meningioma: role of 68Ga DOTA-NOC PET/CT.

    abstract:OBJECTIVE:To assess the ability of Ga DOTA-NOC PET/computed tomography (CT) to differentiate dural metastases from meningioma. PATIENTS AND METHODS:Patients who underwent a Ga DOTA-NOC PET/CT for differentiating meningiomas from dural metastases were included in the study. A visual score was assigned to the dural lesi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001155

    authors: Purandare NC,Puranik A,Shah S,Agrawal A,Gupta T,Moiyadi A,Shetty P,Shridhar E,Patil V,Rangarajan V

    更新日期:2020-04-01 00:00:00

  • Evaluation of bile duct complications after orthotopic liver transplantation by hepatobiliary scanning.

    abstract::A new radiopharmaceutical for hepatobiliary scanning, 99Tcm Iodida, which has significant advantages in patients with high bilirubinaemia, was used to assess biliary tract complications in 30 consecutive liver transplant patients. There was adequate hepatic extraction and excretion for diagnostic imaging even in patie...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199011000-00005

    authors: Lantsberg S,Lanchbury EE,Drolc ZA

    更新日期:1990-11-01 00:00:00

  • Impact of fluorodeoxyglucose PET on the management of esophageal cancer.

    abstract::Esophageal cancer is the third most common malignancy of the alimentary tract. The incidence of esophageal cancer has steadily increased over the past three decades. Almost all therapeutic modalities for esophageal cancer are associated with a considerable mortality and morbidity. Consequently, there has been growing ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0b013e32831af204

    authors: Salavati A,Basu S,Heidari P,Alavi A

    更新日期:2009-02-01 00:00:00

  • 99mTc galactosyl human serum albumin liver dynamic SPET for pre-operative assessment of hepatectomy in relation to percutaneous transhepatic portal embolization.

    abstract::We have devised an original predictive residual index (PRI) using 99mTc diethylenetriaminepentaacetic acid galactosyl human serum albumin (99mTc-GSA) liver dynamic SPET for the pre-operative assessment of hepatectomy, including the prediction of residual liver function before hepatectomy. The aim of this study was to ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200307000-00011

    authors: Nishiyama Y,Yamamoto Y,Hino I,Satoh K,Wakabayashi H,Ohkawa M

    更新日期:2003-07-01 00:00:00

  • UK audit of single photon emission computed tomography reconstruction software using software generated phantoms.

    abstract::The purpose of this study was to undertake an audit of the quantitative characteristics of single photon emission computed tomography software using projection data from an analytically generated software phantom and a measured line source. The phantom consisted of three structures. A uniformly filled cylinder, a seri...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200205000-00009

    authors: Jarritt PH,Whalley DR,Skrypniuk JV,Houston AS,Fleming JS,Cosgriff PS

    更新日期:2002-05-01 00:00:00

  • Quantitation of renal function with 99Tcm-DMSA. A comparison with creatinine clearance in children with single kidney.

    abstract::To study the accuracy of renal function quantification with 99Tcm-DMSA we compared DMSA renal uptake and creatinine clearance in 16 cases of children with single kidney. The age of the patients ranged from two months to fourteen years. Creatinine clearance was normalized to 1.73 m2. DMSA uptake was measured 7 h after ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198511000-00009

    authors: Baillet G,Gagnadoux MF,De Vernejoul P,Broyer M

    更新日期:1985-11-01 00:00:00

  • New possibilities in erythrocyte survival studies with the application of a Well-type germanium semiconductor detector.

    abstract::The application of a Well-type germanium semiconductor detector creates new possibilities in erythrocyte survival studies. Using 51Cr, the effective dose equivalent in a standard procedure can be reduced from approximately 780 to 2 microSv. The properties of the detector, namely, high efficiency and high energy resolu...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199105000-00010

    authors: De Vries RA,Oldenburg SJ,Thelosen T,De Bruin M,Poortman J,Van de Wiel A

    更新日期:1991-05-01 00:00:00