Contribution of 99mTc-anti-carcinoembryonic antigen antibody and 99mTc-sestamibi scintimammography in the evaluation of high risk palpable breast lesions.

Abstract:

:Mammography is the screening test of choice for breast cancer. Its low specificity leads to a large number of unnecessary biopsies. Scintimammography, with either Tc-sestamibi (MIBI) or Tc-anti-carcinoembryonic antigen (CEA) Fab', has been proposed as a non-invasive test to lower the high false positive rate of mammography in certain patients. The two agents have not been compared, nor has their combined application been evaluated. We performed a prospective, non-randomized, open-label, single-centre study of 32 women with clinically and mammographically suspected breast cancer [Breast Imaging Reporting and Data System (BI-RADS, American College of Radiology) 4 or 5]. All patients underwent Tc-MIBI and Tc-anti-CEA Fab' scintimammography, and the results were correlated with histopathology. Overall, the accuracies for MIBI and CEA scans were 90.3% (28/31) and 77.4% (24/31), respectively. The probability of disease after mammography was 0.939+/-0.081 (95% confidence interval, CI). The post-mammography probabilities after positive MIBI or CEA scan were 0.965 and 0.960, respectively, and after negative MIBI or CEA scan 0.750 and 0.875, respectively. None of the above differences is significant. The post-test probability when both scans were positive (irrespective of which was performed first) was 0.977. It can be concluded that there are indications that scintimammography with Tc-MIBI is superior to that with Tc-anti-CEA Fab' when these tests are used as screening tests for breast cancer. However, mammography remains the screening test of choice for highly suspicious clinically palpable breast lesions. In this group of patients, the application of scintimammography with either Tc-MIBI or Tc-anti-CEA Fab' (alone or in combination) offers no additional advantage.

journal_name

Nucl Med Commun

authors

Sanidas EE,Koukouraki S,Velidaki A,Manios A,Stathopoulos E,De Bree E,Kafousi M,Kodogiannis E,Karkavitsas N,Tsiftsis DD

doi

10.1097/00006231-200303000-00009

keywords:

subject

Has Abstract

pub_date

2003-03-01 00:00:00

pages

291-6

issue

3

eissn

0143-3636

issn

1473-5628

journal_volume

24

pub_type

临床试验,杂志文章
  • Analysis of radiation doses received by the public from 131I treatment of thyrotoxic outpatients.

    abstract::Radiation doses to the family and general public from 131I therapy of outpatients were assessed for comparison with the 1990 International Commission on Radiation Protection (ICRP) dose limits. Doses to family members of such patients, measured by previous workers, were converted to show that on average 5.6 +/- 3.7 mi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199309000-00004

    authors: Wasserman HJ,Klopper JF

    更新日期:1993-09-01 00:00:00

  • Validation of the CT iterative reconstruction technique for low-dose CT attenuation correction for improving the quality of PET images in an obesity-simulating body phantom and clinical study.

    abstract:OBJECTIVE:The aim of this study was to validate the efficacy of computed tomography (CT) iterative reconstruction (CT-IR) for low-dose CT attenuation correction in terms of the estimation of attenuation coefficient and quality of PET images. MATERIALS AND METHODS:We used normal and obesity-simulating body phantoms. PE...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000326

    authors: Matsutomo N,Nagaki A,Sasaki M

    更新日期:2015-08-01 00:00:00

  • Comparison of [18F]fluorodeoxyglucose uptake with glucose transporter-1 expression and proliferation rate in human glioma and non-small-cell lung cancer.

    abstract::To clarify the biological significance of [18F]fluorodeoxyglucose (18F-FDG) accumulation in patients with cancer, we assessed the relationships between 18F-FDG uptake and glucose transporter-1 (GLUT-1) expression and proliferation rate in human glioma and lung cancer. We obtained FDG PET images and measured standardiz...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200401000-00003

    authors: Chung JK,Lee YJ,Kim SK,Jeong JM,Lee DS,Lee MC

    更新日期:2004-01-01 00:00:00

  • Sentinel node localization in patients with non-palpable breast cancer.

    abstract::The aim of this study was to demonstrate that radionuclide sentinel node detection can be applied to patients with non-palpable breast cancer. One hundred and ten consecutive women with unilateral breast cancer were studied. Group 1 was made up of 80 patients with palpable breast cancer (mean age, 58 years) and group ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200212000-00003

    authors: Fernandez A,Escobedo A,Benito E,Azpeitia D,Guma A,Prieto L,Moreno A,Martin-Comin J

    更新日期:2002-12-01 00:00:00

  • Uptake of 77Br-spiperone in the striata of schizophrenic patients and controls.

    abstract::Twelve patients with a diagnosis of schizophrenia and thirteen control subjects were injected with 77Br-bromospiperone and scanned using single photon emission tomography after 16 h. Although a statistically significant increase in patients by comparison with controls could be demonstrated, wide variations in specific...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198608000-00006

    authors: Crawley JC,Crow TJ,Johnstone EC,Oldland SR,Owen F,Owens DG,Smith T,Veall N,Zanelli GD

    更新日期:1986-08-01 00:00:00

  • Comparison of 99mTc-DTPA and serum creatinine, cystatin C in detection of glomerular filtration rate: a retrospective clinical data analysis of 744 Chinese subjects.

    abstract:BACKGROUND:To compare the accuracy of various equations for estimating glomerular filtration rate. METHODS:Chronic kidney disease was classified by Tc-DTPA scintigraphy (reference glomerular filtration rate), estimating glomerular filtration rate was estimated using various formulas. The similarity to reference glomer...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001141

    authors: Yang SK,Zeng LF,Zhao QY,Zen ZP,Li AM,Zhang LW,Li L,Song N,Liu Y,Zhang H

    更新日期:2020-03-01 00:00:00

  • Assessment of tissue viability in frostbite by 99Tcm-HDP scintigraphy: an experimental study in New Zealand white rabbits.

    abstract::Since the appearance of superficial tissue is often an unreliable indicator of deep tissue viability in cases of frostbite, radionuclide scintigraphy with 99Tcm-disodium oxidronate (HDP) was used to assess changes in tissue viability after experimental freezing and thawing of the rabbit ear. One shaved ear, left or ri...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199207000-00010

    authors: Junila J,Torniainen P,Kaarela O,Kairaluoma MI,Waris T

    更新日期:1992-07-01 00:00:00

  • One year's clinical experience of 18F-FDG PET with a modified SPET camera using molecular coincidence detection.

    abstract::High-quality positron emission tomographic (PET) cameras are expensive and, therefore, not available in many centres. To allow access to clinical 18F-fluorodeoxyglucose (18F-FDG) PET, we began working with an ADAC Vertex camera equipped with a molecular coincidence detection (MCD) module in February 1997. Here we give...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199911000-00005

    authors: Erler H,Zaknun J,Donnemiller E,Bacher-Stier C,Oberladstätter M,Riccabona G,Moncayo R

    更新日期:1999-11-01 00:00:00

  • 99mTc galactosyl human serum albumin liver dynamic SPET for pre-operative assessment of hepatectomy in relation to percutaneous transhepatic portal embolization.

    abstract::We have devised an original predictive residual index (PRI) using 99mTc diethylenetriaminepentaacetic acid galactosyl human serum albumin (99mTc-GSA) liver dynamic SPET for the pre-operative assessment of hepatectomy, including the prediction of residual liver function before hepatectomy. The aim of this study was to ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200307000-00011

    authors: Nishiyama Y,Yamamoto Y,Hino I,Satoh K,Wakabayashi H,Ohkawa M

    更新日期:2003-07-01 00:00:00

  • Relationship between myocardial counts and patient weight: adjusting the injected activity in myocardial perfusion scans.

    abstract::It is generally accepted that the quality of myocardial images deteriorates with increasing patient weight. This is attributed to a reduction of counts detected from the myocardium. In this paper we have looked at the count reduction in obese patients and suggest a workable algorithm to increase the injected activity ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00006231-200301000-00015

    authors: Notghi A,Williams N,Smith N,Goyle S,Harding LK

    更新日期:2003-01-01 00:00:00

  • Changes in septal regional ejection fraction early and late following coronary artery bypass grafting in patients without postoperative myocardial infarction.

    abstract::Changes in regional ejection fraction (rEF) of the interventricular septum following coronary artery bypass graft (CABG) surgery were examined using first-pass radionuclide ventriculography (RNVG) in patients without objective evidence of postoperative myocardial infarction (MI). One hundred and one patients had pre- ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Jacobson AF,Tow DE,Lapsley D,Khuri S

    更新日期:1992-10-01 00:00:00

  • An assessment of finger doses received by staff while preparing and injecting radiopharmaceuticals.

    abstract::Good working practice and legal obligation impose a duty on nuclear medicine departments to check syringe activities before administration to a patient. If syringe guards are used to reduce staff exposure while drawing up injections, the guard has to be removed to measure the activity in a conventional reentrant ioniz...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199708000-00013

    authors: Hastings DL,Hillel PG,Jeans SP,Waller ML

    更新日期:1997-08-01 00:00:00

  • Nuclear cardiology in the UK: British Nuclear Cardiology Society survey 1994.

    abstract::This study surveyed practice in nuclear cardiology in the UK in 1994. A questionnaire was sent to 219 centres performing nuclear imaging asking for details of current practice in nuclear cardiology. Replies were received from 192 centres (88%). Activity in performance of myocardial perfusion imaging (MPI) and radionuc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199804000-00004

    authors: Pennell DJ,Prvulovich E,Tweddel A,Caplin J

    更新日期:1998-04-01 00:00:00

  • Assessment of left ventricular function by 201Tl SPECT using left ventricular cavity-to-myocardium count ratio.

    abstract::Equilibrium radionuclide angiography (ERNA) is the 'gold standard' for assessing left ventricular ejection fraction (LVEF). The aim of the study was to determine whether the left ventricular cavity-to-myocardium count ratio (LVCMR) from 201Tl myocardial single photon emission computed tomography (SPECT) correlated wit...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200103000-00004

    authors: Maunoury C,Antonietti T,Sebahoun S,Barritault L

    更新日期:2001-03-01 00:00:00

  • Incidental detection of apical hypertrophic cardiomyopathy by myocardial perfusion imaging.

    abstract:BACKGROUND:Echocardiography plays a central role in the diagnosis of hypertrophic cardiomyopathy (HCM). However, apical involvement of HCM may be missed because of foreshortening and inadequate clinical suspicion. These patients may be referred for single-photon emission computed tomography imaging. METHODS:We present...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328334fc41

    authors: Irwin RB,Arumugam P,Khattar RS

    更新日期:2010-04-01 00:00:00

  • Stunning phenomenon after a radioactive iodine- ¹³¹I diagnostic whole-body scan: Is it really a point of clinical consideration?

    abstract:PURPOSE:Stunning of thyroid remnants after diagnostic scanning (Dx-WBS) using radioactive iodine- (¹³¹I) may limit the efficacy of I therapy. We aimed to evaluate this assumption in a prospectively designed study. METHODS:Forty patients who underwent thyroidectomy for differentiated thyroid carcinoma were studied and ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e328362ad63

    authors: Amin A,Amin M,Badwey A

    更新日期:2013-08-01 00:00:00

  • The evaluation of right ventricular function in acute myocardial infarction by xenon-133.

    abstract::Right ventricular performance was assessed in 37 patients with acute myocardial infarction within two hours of admission to Coronary Care and compared to results in 21 normal volunteers and 12 patients undergoing coronary arteriography. Right ventricular ejection fraction (RVEF) was measured from gated xenon-133 scans...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198901000-00006

    authors: Martin W,Tweddel A,McGhie I,Hutton I

    更新日期:1989-01-01 00:00:00

  • Reproducibility of gastric emptying of a pancake and milkshake meal in normal subjects.

    abstract::Comparisons of gastric emptying between different centres are difficult because of wide variations in methods. Reproducibility of a method is very important before it is used to compare different subjects or to assess the effect of treatment. The aim of this study was to measure the reproducibility of gastric emptying...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199801000-00011

    authors: Kong MF,Perkins AC,King P,Blackshaw PE,Macdonald IA

    更新日期:1998-01-01 00:00:00

  • Quantifying the value of diagnostic tests.

    abstract::This paper considers the different statistics that can be derived from studies on the value of diagnostic tests. Well-accepted quantities, such as sensitivity and specificity, are reviewed and the value of the likelihood ratio in communicating particular test results is highlighted. A new quantity, the 'diagnostic val...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-199810000-00010

    authors: Lloyd JJ,Talbot PR,Lawson RS

    更新日期:1998-10-01 00:00:00

  • Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction.

    abstract:PURPOSE:To test the potential of a new reconstruction algorithm with Monte Carlo-based scatter correction in half-time myocardial perfusion single-photon emission computed tomography (SPECT). MATERIALS AND METHODS:The mathematical four-dimensional NURBS-based Cardiac-Torso phantom and the SIMIND Monte Carlo simulation...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328349c765

    authors: Kangasmaa TS,Kuikka JT,Vanninen EJ,Mussalo HM,Laitinen TP,Sohlberg AO

    更新日期:2011-11-01 00:00:00

  • Clinical evaluation of hypertrophic cardiomyopathy by myocardial scintigraphy using 123I-labelled 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (123I-BMIPP).

    abstract::To evaluate the clinical utility of 123I-labelled 15-(p-iodophenyl)-3-R, S-methylpentadecanoic acid (123I-BMIPP), myocardial scintigraphy using 123I-BMIPP was performed in 13 patients with hypertrophic cardiomyopathy (HCM), and the findings were compared with those of 201Tl. The uptake of each tracer was scored visual...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199406000-00008

    authors: Ohtsuki K,Sugihara H,Umamoto I,Nakamura T,Nakagawa T,Nakagawa M

    更新日期:1994-06-01 00:00:00

  • Dynamic evaluation of absorbed dose to the bladder wall with a balloon-bladder phantom during a study using [(18)F]fluorodeoxyglucose positron emission imaging.

    abstract::An accurate evaluation of the absorbed dose to the bladder wall from 2-[(18)F]fluoro-2-deoxy-d-glucose (FDG) is clinically important because the bladder is considered as a critical organ in most positron emission tomography (PET) studies that cumulate about 20% of the total activity injection during image procedures. ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200208000-00008

    authors: Wu TH,Liu RS,Dong SL,Chung YW,Chou KL,Lee JS

    更新日期:2002-08-01 00:00:00

  • Visual and semiquantitative analysis of 82Rb uptake in malignant tumors on PET/CT: first systematic analysis.

    abstract:OBJECTIVE:The objective of this study was to analyze the uptake of rubidium in malignant tumors. PARTICIPANTS AND METHODS:Sixteen malignant lesions were included. Two radiologists compared each lesion to four references (subcutaneous fat, lung, mediastinal blood pool, and liver) at rest and stress and scored as 1-4. M...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001011

    authors: Khandani AH,Commander CW,Desai H,Oldan JD,Wong TZ,Benefield T,Ivanovic M

    更新日期:2019-05-01 00:00:00

  • Abdominal scintigraphy with 99Tcm-labelled red cells in the detection of rebleeding from peptic ulcers.

    abstract::The technique of 99Tcm-labelled red cell scintigraphy as a means of detecting rebleeding was investigated in 33 patients with bleeding peptic ulcers. Scintigrams were performed twice during the 24 h period succeeding diagnostic endoscopy. There was scintigraphic evidence of rebleeding in 23 patients but this was clini...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198509000-00003

    authors: Kinnear WJ,Dickinson RJ,Buxton-Thomas M,Wraight EP

    更新日期:1985-09-01 00:00:00

  • A new non-invasive test for the detection of compartment syndromes.

    abstract::Chronic exertional compartment syndrome (CECS) is currently diagnosed using invasive pressure measurements. We report the use of 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) scintigraphy as a new non-invasive method of diagnosis. Forty-six patients with suspected chronic compartment syndrome underwent graded treadmil...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199903000-00003

    authors: Edwards PD,Miles KA,Owens SJ,Kemp PM,Jenner JR

    更新日期:1999-03-01 00:00:00

  • Evaluation of three methods of platelet labelling.

    abstract::The study of the kinetics of labelled platelets makes sense only when the platelets preserve their viability after separation and labelling. The separation and labelling procedures described in the manual of two producers of 111In-oxinate (Amersham, Mallinckrodt) have been evaluated by in vitro aggregation tests. The ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Mortelmans L,Verbruggen A,De Roo M,Vermylen J

    更新日期:1986-07-01 00:00:00

  • Use of insulin to improve [18 F]fluorodeoxyglucose labelling and retention for in vivo positron emission tomography imaging of monocyte trafficking.

    abstract::While 18F-FDG labelling of monocytes would allow in vivo trafficking with positron emission tomography (PET), present methods suffer from poor retention of radioactivity. We investigated the feasibility of utilizing insulin for improved [18F]fluorodeoxyglucose (18F-FDG) labelling. Separated human monocytes and lymphoc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200206000-00007

    authors: Paik JY,Lee KH,Byun SS,Choe YS,Kim BT

    更新日期:2002-06-01 00:00:00

  • Focus localization in patients with partial epilepsy with 99Tcm-HMPAO SPECT under continuous surface EEG monitoring.

    abstract::Our study was aimed at determining the validity of 99Tcm-HMPAO single photon emission computed tomography (SPECT) in the localization of the epileptogenic focus by correlating this diagnostic method with other auxiliary investigations such as surface EEG and X-ray transmission computed tomography (CT). Twenty-eight pa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199203000-00002

    authors: Verhoeff NP,Weinstein HC,Aldenkamp AP,Overweg J,Van Royen EA,Verbeeten B Jr

    更新日期:1992-03-01 00:00:00

  • Bone scan index as metastatic bone disease quantifier and predictor of radium-223-dichloride biochemical response.

    abstract:OBJECTIVES:This work aims to assess whether the biochemical response of radium-223-dichloride treatment can be predicted based on the pretherapy bone scan, and consequently if bone scan index (BSI) and maximum lesion intensity have a place as alternatives or as complements to extent of bone disease (EOBD) scoring in pr...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001005

    authors: Roque V,Jessop M,Pereira L,Gape P,Dizdarevic S,Sousa E,Carolino E

    更新日期:2019-06-01 00:00:00

  • Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    abstract:OBJECTIVE:Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. PATIENTS AND METHODS:A total of 109 patients with typical angina and no previous coronary artery di...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0000000000000739

    authors: Ejlersen JA,May O,Mortensen J,Nielsen GL,Lauridsen JF,Allan J

    更新日期:2017-11-01 00:00:00