Validation of the CT iterative reconstruction technique for low-dose CT attenuation correction for improving the quality of PET images in an obesity-simulating body phantom and clinical study.

Abstract:

OBJECTIVE:The aim of this study was to validate the efficacy of computed tomography (CT) iterative reconstruction (CT-IR) for low-dose CT attenuation correction in terms of the estimation of attenuation coefficient and quality of PET images. MATERIALS AND METHODS:We used normal and obesity-simulating body phantoms. PET images were reconstructed using two attenuation correction maps obtained using filtered back projection (CT-FBP) and CT-IR. The CT numbers, attenuation coefficients, contrast-to-noise ratio (CNR10 mm), and coefficient of variation were evaluated. Fifty-two consecutive patients who underwent F-FDG PET/CT with low-dose CT scans were selected for the clinical study. Clinical PET images were reconstructed using CT-FBP and CT-IR, and the effects of CT-IR were examined according to the maximum standardized uptake value (SUVmax), contrast-to-noise ratio in the tumor (CNRtumor), and signal-to-noise ratio in the liver (SNRliver). RESULTS:The CT number on the CT-IR was significantly lower than that of CT-FBP in the obesity-simulating body phantom. The decrease in attenuation coefficients obtained using CT-IR was smaller than that obtained using CT-FBP. The CNR10 mm and coefficient of variation obtained using CT-IR were superior to those obtained using CT-FBP. The SUVmax was not significantly different between the CT-FBP and CT-IR. Although the difference in the SNRliver between the CT-FBP and CT-IR was not significant, the CNRtumor of the CT-IR was significantly higher than that obtained using CT-FBP in obese patients. CONCLUSION:We demonstrated that CT-IR improved the estimation of the attenuation coefficient and provided significant improvement in the CNR of the clinical PET images.

journal_name

Nucl Med Commun

authors

Matsutomo N,Nagaki A,Sasaki M

doi

10.1097/MNM.0000000000000326

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

839-47

issue

8

eissn

0143-3636

issn

1473-5628

journal_volume

36

pub_type

杂志文章
  • Diagnostic performance of a novel dedicated breast PET scanner with C-shaped ring detectors.

    abstract:BACKGROUND:A dedicated breast PET scanner with C-shaped detectors (C scanner) has been newly developed. The purpose of this study was to re-evaluate the diagnostic performance of high-resolution PET images with the new reconstruction conditions, obtained using this C scanner in breast cancer patients, and to compare th...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000661

    authors: Nakamoto R,Nakamoto Y,Ishimori T,Nishimatsu K,Miyake KK,Kanao S,Iima M,Toi M,Togashi K

    更新日期:2017-05-01 00:00:00

  • Kinetic analysis of 99mTc-sestamibi evaluates the protective effects by ischaemic preconditioning on ischaemic myocardium in an isolated rabbit heart.

    abstract:OBJECTIVE:To analyse the kinetic changes of uptake, washout and retention of Tc-sestamibi in order to evaluate the protective effects and possible mechanism of ischaemic preconditioning and adenosine preconditioning on myocardium injured by ischaemia/reperfusion. METHODS:Isolated ischaemia/reperfusion rabbit heart mod...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f1781b

    authors: Liang J,Chen HL,Zhou Y,Xie M,Xu LM,Lin G

    更新日期:2007-11-01 00:00:00

  • Large variations occur in bone density measurements of children when using different software.

    abstract:BACKGROUND:Paediatric dual X-ray absorptiometry (DXA) studies present a number of technical problems. One of these is that the edge detection algorithms designed for the adult skeleton may fail for paediatric studies. Hologic provide alternative algorithms for low bone density studies. AIM:To assess low-density softwa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200506000-00002

    authors: Simpson DE,Dontu VS,Stephens SE,Archbold LJ,Lowe V,O'Doherty MJ,Martin N,Coakley AJ

    更新日期:2005-06-01 00:00:00

  • UK nuclear medicine survey, 1992-93.

    abstract::A postal survey of UK nuclear medicine departments was undertaken to collate information on equipment, numbers of procedures and staffing levels for the years 1992 and 1993. It was estimated that there are 235 sites undertaking nuclear medicine, the total number of procedures performed being some 490,000 in 1993 compa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199601000-00002

    authors: Elliott AT,Elliott FM,Shields RA

    更新日期:1996-01-01 00:00:00

  • 99mTc-NC100668, an agent for imaging venous thromboembolism: The effect of anticoagulant or thrombolytic therapy on the uptake and retention of radioactivity in blood clots in vivo.

    abstract:BACKGROUND:The purpose of this study was to evaluate the uptake of (99m)Tc-NC100668 into blood clots and elucidate the potential for medications commonly used to treat thromboembolism to interfere with the uptake and retention of (99m)Tc-NC100668. METHODS:(99m)Tc-NC100668 in vivo uptake and retention in a range of blo...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000243378.34131.01

    authors: Edwards D,Lewis J,Battle M,Lear R,Farrar G,Jon Barnett D,Godden V,Oliveira A,Coombes C,Ahlström H

    更新日期:2007-01-01 00:00:00

  • Quantitation of skeletal muscle necrosis using 99Tcm-pyrophosphate with SPECT in a canine model.

    abstract::Patients with acute arterial occlusion may suffer from significant muscle necrosis. It is important to determine the amount of regional muscle necrosis for prognostic purposes and evaluation of therapy. We have used technetium-99m-pyrophosphate (PPi) with single photon emission computed tomography (SPECT) to quantitat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199002000-00009

    authors: Yip TC,Houle S,Hayes G,Forrest I,Nelson L,Walker PM

    更新日期:1990-02-01 00:00:00

  • Normal bone and soft tissue distribution of fluorine-18-sodium fluoride and artifacts on 18F-NaF PET/CT bone scan: a pictorial review.

    abstract::Fluorine-18-sodium fluoride (F-NaF) PET/CT is a relatively new and high-resolution bone imaging modality. Since the use of F-NaF PET/CT has been increasing, it is important to accurately assess the images and be aware of normal distribution and major artifacts. In this pictorial review article, we will describe the no...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0000000000000720

    authors: Sarikaya I,Elgazzar AH,Sarikaya A,Alfeeli M

    更新日期:2017-10-01 00:00:00

  • Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time-activity curve for the tracer arterial input function.

    abstract:OBJECTIVE:In-vivo quantitative cerebral blood flow (CBF) measurement using positron emission tomography (PET) has typically employed invasive arterial blood sampling procedure to determine the arterial input function (AIF). The present study was performed to provide a non-invasive quantitative CBF measurement technique...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200510000-00009

    authors: Yee SH,Jerabek PA,Fox PT

    更新日期:2005-10-01 00:00:00

  • 99mTc-HL91 is inferior to 201Tl in scintigraphic detection of chronic myocardial ischaemia.

    abstract:AIM:99mTc-HL91 is a new hypoxia agent and can identify acutely ischaemic viable myocardium in a canine model using a standard gamma camera. The purpose of the study was to determine whether this tracer could be used to detect regional ischaemia in chronic ischaemic myocardium in a swine model. METHOD:Using a porcine m...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200512000-00012

    authors: Wu YW,Lee CM,Huang YH,Chou NK,Yen RF,Tzen KY,Huang PJ

    更新日期:2005-12-01 00:00:00

  • Does renal damage occur after the administration of 32P for palliation of pain from skeletal metastases?

    abstract::In normal adults, the maintenance of phosphate balance involves the reabsorption of 85-90% of filtered phosphate by the proximal tubule. At a glomerular filtration rate (GFR) of 125 ml min-1 and a plasma phosphate concentration of 1.3 mmol l-1, the filtered phosphate is approximately 235 mmol day-1. Following intraven...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199807000-00011

    authors: Nair N,Mahadeo DS,Patel R

    更新日期:1998-07-01 00:00:00

  • Diagnostic accuracy of combined 99mTc-sulesomab and 99mTc-nanocolloid bone marrow imaging in detecting prosthetic joint infection.

    abstract:OBJECTIVE(S):Autologous-labeled leukocytes combined with sulfur colloid bone marrow scan is the current nuclear medicine gold standard for the diagnosis of prosthetic joint infection. The goal of this study is to assess the diagnostic accuracy of a new nuclear medicine modality for detecting infection in this context. ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3283496695

    authors: Sousa R,Massada M,Pereira A,Fontes F,Amorim I,Oliveira A

    更新日期:2011-09-01 00:00:00

  • The use of single photon emission computed tomography in depressive disorders.

    abstract::Single photon emission computed tomography (SPECT) and positron emission tomography (PET) have advanced our understanding of the biological underpinnings of depression. There is, however, considerable variability in the literature. Depression is a complex disorder with marked heterogeneity in diagnosis and treatment. ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-200503000-00004

    authors: Smith DJ,Cavanagh JT

    更新日期:2005-03-01 00:00:00

  • Diastolic dysfunction can precede systolic dysfunction on MUGA in cancer patients receiving trastuzumab-based therapy.

    abstract:BACKGROUND:Trastuzumab (T) and anthracycline (A)-based chemotherapy is considered the standard of care in human epidermal growth factor receptor-2+ overexpressing breast cancer, but requires monitoring for known cardiotoxicity using left ventricular (LV) ejection fraction (EF) every 3-4 months during treatment. It is n...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000941

    authors: Klein R,Nadouri D,Osler E,Johnson C,Dent S,Dwivedi G

    更新日期:2019-01-01 00:00:00

  • Radiolabeling RGD peptide and preliminary biodistribution evaluation in mice bearing S180 tumors.

    abstract:OBJECTIVE:To prepare the rhenium-188 (188Re)-arginine-glycine-aspartic acid (RGD) peptide in a convenient manner and to evaluate its potential as an agent for alphavbeta3 integrin receptor-positive tumors. METHODS:Radiolabeled RGD was obtained by conjugating the His group at the end of peptide with fac-[188Re(H2O)3(CO...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283334e48

    authors: Ma Y,Yu J,Han Y,Shen H,Li Z,Zhou W,Yin D

    更新日期:2010-02-01 00:00:00

  • Micturition detection switch.

    abstract::Micturating renograms often need to be carried out on children, with whom difficulty may be experienced in synchronizing onset of micturition with camera and computer acquisition. A flow detection system has been developed which will automate these acquisitions, resulting in far fewer false starts or lost studies. The...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198709000-00003

    authors: Burniston MT,Royall RA,Tapper RC

    更新日期:1987-09-01 00:00:00

  • How to assess background activity: introducing a histogram-based analysis as a first step for accurate one-step PET quantification.

    abstract::Many common PET segmentation methods for malignant lesions use surrounding background activity as a reference. To date, background has to be measured by drawing a second volume of interest (VOI) in nearby, undiseased tissue. This is time consuming as two VOIs have to be determined for each lesion. The aim of our study...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000045

    authors: Burger IA,Vargas HA,Beattie BJ,Goldman DA,Zheng J,Larson SM,Humm JL,Schmidtlein CR

    更新日期:2014-03-01 00:00:00

  • Radionuclide synovectomy in haemophilic joints.

    abstract::Chronic synovitis often occurs in people with haemophilia. Untreated chronic haemophilic synovitis affects the metabolism of chondrocytes, thus leading to haemophilic arthropathy. A recently introduced therapeutic protocol includes radiation synovectomy (RS), a safe and cost-effective therapeutic method, which has giv...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0b013e32835ed50c

    authors: Teyssler P,Kolostova K,Bobek V

    更新日期:2013-04-01 00:00:00

  • 99Tcm-LL1: a potential new bone marrow imaging agent.

    abstract::LL1, a monoclonal antibody (MAb) to HLA Class-II-like antigen (li determinant) on the surface of B-lymphocytes, monocytes and histiocytes, was evaluated as an agent for bone marrow imaging. Six patients with diverse diseases (non-Hodgkin's lymphoma, n = 2; multiple myeloma, n = 1; polycythaemia vera, n = 1; lung cance...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Juweid M,Dunn RM,Sharkey RM,Rubin AD,Hansen HJ,Goldenberg DM

    更新日期:1997-02-01 00:00:00

  • Removal of the internal mammary sentinel node in breast cancer.

    abstract:OBJECTIVE:The aim of the study was to determine the evolution of patients with internal mammary chain (IMC) drainage whether the IMC-sentinel lymph node (IMC-SLN) was biopsied or not, as well as to determine the clinical implications of the biopsy of the IMC-SLN (IMC-SLNB) in patients with breast cancer and IMC drainag...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328330addf

    authors: Domènech-Vilardell A,Bajén MT,Benítez AM,Ricart Y,Mora J,Rodríguez-Bel L,García-Tejedor A,Climent J,López-Ojeda A,Urruticoechea A,Martín-Comín J

    更新日期:2009-12-01 00:00:00

  • The role of IDA scintigraphy in the follow-up of liver disease in patients with cystic fibrosis.

    abstract::The main aim of this study was to investigate the role of N-(2,4,6 trimethyl-3-bromophenylcarbamoylmethyl) iminodiacetic acid (IDA; Mebrofenin) scintigraphy in follow-up assessments of the biliary system in patients with cystic fibrosis associated liver disease. Fourteen patients from a study published in 1996 were re...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200207000-00012

    authors: Foster JA,Ramsden WH,Conway SP,Taylor JM,Etherington C

    更新日期:2002-07-01 00:00:00

  • A meta-analysis of scintimammography: an evidence-based approach to its clinical utility.

    abstract:BACKGROUND:Scintimammography using (99m)Tc-labelled isonitriles, sestamibi and tetrofosmin, has become a mature technique in the adjunctive setting for the diagnosis of primary breast cancer. To establish an evidence base for its use, clinically, a meta-analysis was performed on both single-site and multi-centre trials...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/00006231-200607000-00007

    authors: Hussain R,Buscombe JR

    更新日期:2006-07-01 00:00:00

  • Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation.

    abstract:OBJECTIVE:Gated blood-pool single-photon emission computed tomography (GBPS) was compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular (LV) and right ventricular (RV) ejection fractions (EF) and volumes [end-diastolic volume (EDV) or end-systolic volume (ESV)] in a mixed population. ME...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e32834155f1

    authors: Sibille L,Bouallegue FB,Bourdon A,Micheau A,Vernhet-Kovacsik H,Mariano-Goulart D

    更新日期:2011-02-01 00:00:00

  • A pilot study of flaccid penile blood flow patterns in normal subjects and patients with erectile dysfunction.

    abstract::Dynamic penile scintigraphy was performed using 99Tcm-labelled autologous erythrocytes in five normally potent volunteers and 22 patients with erectile dysfunction including 11 patients with psychogenic and 11 patients with vasculogenic impotence (four arteriogenic, three venogenic, three arteriogenic and venogenic, o...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199311000-00007

    authors: Siraj QH,Hilson AJ,Bomanji J,Ahmed M

    更新日期:1993-11-01 00:00:00

  • False-positive F-18 FDG uptake in PET/CT studies in pediatric patients with abdominal Burkitt's lymphoma.

    abstract:INTRODUCTION:In pediatric patients with abdominal Burkitt's lymphoma, the involvement of the gastrointestinal tract and abdominal lymph nodes are the main presenting feature of the disease. Chemotherapy is the main treatment modality and could be preceded by surgical excision of the abdominal masses. To achieve cure or...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328334fc14

    authors: Riad R,Omar W,Sidhom I,Zamzam M,Zaky I,Hafez M,Abdel-Dayem HM

    更新日期:2010-03-01 00:00:00

  • Radionuclide limb blood flow in peripheral vascular disease: a review of 1100 measurements.

    abstract::Radionuclide limb blood flow measurements using 99Tcm-labelled human serum albumin and a gamma camera have been performed on normal volunteers and on patients with suspected or confirmed peripheral arterial disease. The normal range of flow was found to be 10.0-22.3 ml per 100 ml tissue per min. Flow in the symptomati...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199110000-00003

    authors: Parkin A,Robinson PJ,Martinez D,Wilkinson D,Kester RC

    更新日期:1991-10-01 00:00:00

  • The role of positron emission tomography with fluorine-18-deoxyglucose in identifying colorectal cancer metastases to liver.

    abstract::Liver metastasis is a common consequence of colorectal carcinoma. Early and accurate detection of liver metastasis is crucial for a decision about partial hepatectomy, which is considered a standard and potentially curative therapy in such a setting. The presence of extrahepatic metastases will exclude surgical resect...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200009000-00002

    authors: Zhuang H,Sinha P,Pourdehnad M,Duarte PS,Yamamoto AJ,Alavi A

    更新日期:2000-09-01 00:00:00

  • The differential ratio. A method for describing blood flow in renal transplants.

    abstract::The blood flow in renal transplants can be represented by (1) a K/A ratio, the ratio of the slopes of the ascending part of the renal perfusion curve and the arterial curve, (2) a perfusion index, the ratio of a part of the area under the first-pass arterial curve and renal curve, and (3) a height ratio, the ratio of ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199011000-00006

    authors: Groothedde RT,Koppejan LJ,Heidendal GK,Hasman A

    更新日期:1990-11-01 00:00:00

  • Time sensitivity-corrected retention index: an enhanced metabolic index from 18F-FDG PET to differentiate between benign and malignant pulmonary nodules.

    abstract::The aim of the study was to evaluate pulmonary nodules (PNs) by incorporating time sensitivity (S) factor in the retention index (RI) and compare with the traditional fixed interval method. After obtaining approval from the Human Investigations Committee, 97 PNs from 81 patients (age=70±11) referred for dual-time fluo...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000190

    authors: Wong CY,Al-faham Z,Jolepalem P,Wong WW,Thie J

    更新日期:2014-12-01 00:00:00

  • A review of captopril renal scintigraphy and its effect on patient management.

    abstract::Renal artery stenosis is an important and potentially curable cause of hypertension. Captopril renography is now recognized to have a high sensitivity and specificity in its diagnosis. Ultimately, however, the result is of little benefit if it does not lead to a change in patient management. To assess how patient mana...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199707000-00006

    authors: Ramsay D,Belton I,Finlay D

    更新日期:1997-07-01 00:00:00

  • Long-term effects of antilipidaemic therapy on left ventricular function in patients with dyslipidaemia: multigated radionuclide ventriculography study.

    abstract:AIM:It has been reported that dyslipidaemia impairs left ventricular systolic (LVs) and diastolic (LVd) functions, irrespective of atherogenic effects, in the setting of coronary artery disease. The aim of the present study was to evaluate the effects of anti-lipidaemic therapy on LVs and LVd functions by means of mult...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.mnm.0000172740.98369.ed

    authors: Entok E,Unalir A,Cavusoglu Y,Timuralp B,Vardareli E

    更新日期:2005-09-01 00:00:00