Removal of the internal mammary sentinel node in breast cancer.

Abstract:

OBJECTIVE:The aim of the study was to determine the evolution of patients with internal mammary chain (IMC) drainage whether the IMC-sentinel lymph node (IMC-SLN) was biopsied or not, as well as to determine the clinical implications of the biopsy of the IMC-SLN (IMC-SLNB) in patients with breast cancer and IMC drainage in the lymphoscintigraphy. METHODS:Eighty-two out of 914 patients included in a prospective database of sentinel node (9%) showed IMC drainage and were included in the study. Two groups were established depending on the IMC-SLN removal: group A (IMC-SLN were removed): 44 patients, mean age 48.8 years, mean follow-up, 35.8 months. Group B (IMC-SLN were not removed): 38 patients, mean age 54.5 years, mean follow-up, 33.5 months. Kaplan-Meier plots were used to determine the overall survival rates. RESULTS:Group A: four patients showed only IMC drainage, six patients presented positive IMC-SLN, nodal staging changed in five patients, treatment changed in two patients and tumour node metastasis stage grouping changed in three patients. All patients are currently disease-free. Group B: two patients showed only IMC drainage, axillary-SLN were positive in 12 patients, one patient presented nodal axillary and breast recurrence as well as distant disease and one patient presented multiorganic disease. This last patient died. The overall survival rates were very similar in both the groups. CONCLUSION:IMC-SLNB improves nodal staging in breast cancer but has little impact on adjuvant treatment. However, it should be performed to obtain results, which will determine in the future whether it improves survival rates or not.

journal_name

Nucl Med Commun

authors

Domènech-Vilardell A,Bajén MT,Benítez AM,Ricart Y,Mora J,Rodríguez-Bel L,García-Tejedor A,Climent J,López-Ojeda A,Urruticoechea A,Martín-Comín J

doi

10.1097/MNM.0b013e328330addf

subject

Has Abstract

pub_date

2009-12-01 00:00:00

pages

962-70

issue

12

eissn

0143-3636

issn

1473-5628

journal_volume

30

pub_type

杂志文章
  • Clinical competence in myocardial perfusion scintigraphic stress testing: general training guidelines and assessment.

    abstract::The suggestion by the National Institute for Clinical Excellence (NICE) to more than triple the number of myocardial perfusion scintigraphy (MPS) procedures carried out by the NHS each year is a challenge both in terms of numbers of gamma cameras available to carry out the scans and qualified staff to supervise stress...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,实务指引

    doi:10.1097/MNM.0b013e32818a6e72

    authors: Jones I,Latus K,Bartle L,Gardner M,Parkin V,Guideline Development and Writing Group, British Nuclear Medicine Society and British Nuclear Cardiac Society.

    更新日期:2007-07-01 00:00:00

  • In vivo kinetics of 123I-labelled insulin: studies in normal subjects and patients with diabetes mellitus.

    abstract::Radioactive tracer techniques using 131I- and 125I-insulin have been applied to study insulin metabolism. A simple method to label human insulin with 123I to a high specific activity is described. We have used this radiotracer to study insulin kinetics in vivo in normal subjects and in two groups of diabetic patients....

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198710000-00003

    authors: Sinclair AJ,Signore A,Bomanji J,Britton KE,Pozzilli P,Gale EA

    更新日期:1987-10-01 00:00:00

  • A review of captopril renal scintigraphy and its effect on patient management.

    abstract::Renal artery stenosis is an important and potentially curable cause of hypertension. Captopril renography is now recognized to have a high sensitivity and specificity in its diagnosis. Ultimately, however, the result is of little benefit if it does not lead to a change in patient management. To assess how patient mana...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199707000-00006

    authors: Ramsay D,Belton I,Finlay D

    更新日期:1997-07-01 00:00:00

  • The effectiveness of low-dose versus high-dose 99mTc MIBI protocols for radioguided surgery in patients with primary hyperparathyroidism.

    abstract:OBJECTIVE:The aim of this study was to compare the efficacy of low-dose and high-dose (99m)Tc methoxy isobutyl isonitrile (MIBI) protocols in intraoperative localization of parathyroid adenomas by means of a gamma probe in patients with primary hyperparathyroidism (PHPT). PATIENTS AND METHODS:The study included 62 pat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000056

    authors: Gencoglu EA,Aras M,Moray G,Aktas A

    更新日期:2014-04-01 00:00:00

  • Quantitation of skeletal muscle necrosis using 99Tcm-pyrophosphate with SPECT in a canine model.

    abstract::Patients with acute arterial occlusion may suffer from significant muscle necrosis. It is important to determine the amount of regional muscle necrosis for prognostic purposes and evaluation of therapy. We have used technetium-99m-pyrophosphate (PPi) with single photon emission computed tomography (SPECT) to quantitat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199002000-00009

    authors: Yip TC,Houle S,Hayes G,Forrest I,Nelson L,Walker PM

    更新日期:1990-02-01 00:00:00

  • Could the skewness and kurtosis texture parameters of lesions obtained from pretreatment Ga-68 DOTA-TATE PET/CT images predict receptor radionuclide therapy response in patients with gastroenteropancreatic neuroendocrine tumors?

    abstract:PURPOSE:In our study, tumor heterogeneity was evaluated using the parameters skewness and kurtosis on pretreatment Ga-68 DOTA-TATE PET/CT to assess therapy responses of lesions in patients with gastroenteropancreatic neuroendocrine tumors (GEP NETs) treated with peptide receptor radionuclide therapy (PRRT). METHOD:We ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001231

    authors: Önner H,Abdülrezzak Ü,Tutuş A

    更新日期:2020-10-01 00:00:00

  • Influence of statistical noise on the determination of the single kidney 99Tcm-DTPA clearance.

    abstract::Single kidney clearance can be obtained using the 99Tcm-DTPA complex and the scintillation camera. In order to evaluate the influence of statistical noise on the determination of the clearance, several non-noisy curves were constructed, simulating renal, background and precordial curves. Poisson noise was added to the...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198508000-00008

    authors: Piepsz A,Dobbeleir A,Ham HR

    更新日期:1985-08-01 00:00:00

  • Pancreatic cancer detected by positron emission tomography with 18F-labelled deoxyglucose: method and first results.

    abstract::In order to evaluate the utility of positron emission tomography (PET) with 18F-labelled deoxyglucose (FDG) for detection of pancreatic cancer 15 patients with pancreatic masses shown by computed tomography were investigated. Static PET scans covering an axial field of view of 15 cm were obtained 45 min after intraven...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199307000-00013

    authors: Bares R,Klever P,Hellwig D,Hauptmann S,Fass J,Hambuechen U,Zopp L,Mueller B,Buell U,Schumpelick V

    更新日期:1993-07-01 00:00:00

  • Myocardial 123I-MIBG kinetics in acutely hypothyroid patients with differentiated thyroid carcinoma.

    abstract::Marked changes in cardiac function have been noted in patients with hyperthyroidism or hypothyroidism due both to changes in sympathetic system function and to biochemical modifications of myocardial tissue. Metaiodobenzylguanidine (MIBG), an analogue of norepinephrine, can be used to evaluate myocardial sympathetic t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199908000-00006

    authors: Maini CL,Tofani A,Sciuto R,Ferraironi A,Festa A,Rea S

    更新日期:1999-08-01 00:00:00

  • A 99Tcm-labelled leukotriene B4 receptor antagonist for scintigraphic detection of infection in rabbits.

    abstract::In a search for a rapid and accurate imaging agent for scintigraphic detection of infection and inflammation, an LTB4 receptor antagonist, 99Tcm-RP517, which contains the hydrazino nicotinamide moiety, has been developed recently. To study the in vivo behaviour of 99Tcm-RP517, rabbits with Escherichia coli infection w...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200011000-00010

    authors: Brouwers AH,Laverman P,Boerman OC,Oyen WJ,Barrett JA,Harris TD,Edwards DS,Corstens FH

    更新日期:2000-11-01 00:00:00

  • Meta-analysis of meta-analyses in oncologic positron emission tomography.

    abstract:OBJECTIVES:As PET has become a standard of treatment in patients with cancer, publications of oncologic PET have grown sharply. We aimed to organize the data of meta-analyses of oncologic PET and assess the quality of studies. MATERIALS AND METHODS:The inclusion criteria were studies that meta-analyzed to combine the ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,meta分析

    doi:10.1097/MNM.0000000000000908

    authors: Pak K,Shin S,Kim SJ,Kim K,Seo Y,Kim SJ,Kim IJ

    更新日期:2018-12-01 00:00:00

  • Bone marrow scintigraphy in small cell carcinoma of the lung.

    abstract::A comparative study of bone marrow scintigraphy using 99Tcm-nanocolloid, conventional bone scintigraphy and bone marrow biopsy were performed in 35 patients with histologically proven small cell carcinoma of the lung to determine whether bone marrow scintigraphy has a role in the early detection of bone marrow metasta...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199401000-00006

    authors: Li DJ,Maughan TS,Miles KA,Wraight EP

    更新日期:1994-01-01 00:00:00

  • Evaluation of post-stress left ventricular dysfunction and its relationship with perfusion abnormalities using gated SPECT in patients with cardiac syndrome X.

    abstract:OBJECTIVE:Cardiac syndrome X defines patients with typical angina, a positive exercise ECG stress test and angiographically documented normal coronary arteries. In previous studies, post-stress prolonged left ventricular dysfunction (PLVD) using gated SPECT (G-SPECT) had been well correlated with myocardial perfusion a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f52c49

    authors: Demir H,Kahraman G,Isgoren S,Tan YZ,Kilic T,Berk F

    更新日期:2008-03-01 00:00:00

  • Quantification of the neurokinin 1 receptor ligand [¹¹C]R116301.

    abstract:PURPOSE:Neurokinin 1 (NK1) receptors have been implicated in depression, anxiety, and pain perception. Recently, it was shown that, in the human brain, a specific NK1 receptor-related signal was obtained with the novel radioligand, [¹¹C]R116301, using positron emission tomography. The purpose of this study was to evalu...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e328347e96f

    authors: Wolfensberger SP,Maruyama K,van Berckel BN,Lubberink M,Airaksinen AJ,Boellaard R,Luurtsema G,Reddingius W,Janssens FE,Veltman DJ,Windhorst AD,Leysen JE,Lammertsma AA

    更新日期:2011-10-01 00:00:00

  • 99Tcm-N,N-ethylenedicysteine scintigraphy in children with various renal disorders: a comparative study with 99Tcm-MAG3.

    abstract::We evaluated the clinical usefulness of 99Tcm-N,N-ethylenedicysteine (99Tcm-EC), a new renal tubular agent, in normal children and in children with various renal disorders and compared it with 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3). In a first group of children (Group 1), which included 15 patients and 4 normal c...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199701000-00009

    authors: Kibar M,Noyan A,Anarat A

    更新日期:1997-01-01 00:00:00

  • UK nuclear medicine survey 2003-2004.

    abstract:OBJECTIVES:This survey was designed to assess the trends in the frequencies of nuclear medicine procedures in the UK and to determine their contributions to the annual collective effective dose to the UK population. The average activities administered by nuclear medicine departments were compared with guidance on diagn...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000184939.28994.f9

    authors: Hart D,Wall BF

    更新日期:2005-11-01 00:00:00

  • FDG-PET/CT for diagnosis of primary ovarian cancer.

    abstract:BACKGROUND AND AIM:To evaluate the diagnostic value of integrated 18F-fluorodeoxyglucose (FDG) positron emission tomography and computed tomography (PET/CT) to discriminate malignant from benign ovarian tumors. METHODS:One hundred and eight women suspected of having ovarian cancer underwent preoperative FDG-PET/CT sca...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328345b339

    authors: Kitajima K,Suzuki K,Senda M,Kita M,Nakamoto Y,Onishi Y,Maeda T,Yoshikawa T,Ohno Y,Sugimura K

    更新日期:2011-07-01 00:00:00

  • Can administration of metoclopramide reduce artefacts related to abdominal activity in myocardial perfusion SPECT?

    abstract:OBJECTIVES:Myocardial perfusion SPECT is frequently affected by artefacts related to abdominal activity. Metoclopramide has been suggested to relieve this, but two previous studies have shown conflicting results. METHODS:Ninety-five patients received 10 mg metoclopramide orally after injection of 99mTc-tetrofosmin for...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/01.mnm.0000243368.73141.61

    authors: Grüning T,Brogsitter C,Khonsari M,Jones IW,Nevin SM,Burchert W

    更新日期:2006-12-01 00:00:00

  • Immunotechnological trends in radioimmunotargeting: from 'magic bullet' to 'smart bomb'.

    abstract::The impact of recent advances in the chemical and genetic engineering manipulations of antibodies on radioimmunotargeting is reviewed both in relation to radioimmunoscintigraphy and radioimmunotherapy. The resulting trends are: (1) the linking of parts of the mouse/rat and human antibody molecule; (2) the creation of ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:

    authors: Hazra DK,Britton KE,Lahiri VL,Gupta AK,Khanna P,Saran S

    更新日期:1995-02-01 00:00:00

  • Diagnostic accuracy of 18F-FDG PET/CT in characterizing ovarian lesions and staging ovarian cancer: correlation with transvaginal ultrasonography, computed tomography, and histology.

    abstract:AIMS:To (a) assess the accuracy of 18F-FDG PET/CT in distinguishing malignant from benign pelvic lesions, compared to transvaginal ultrasonography (TVUS) and (b) to establish the role of whole-body 18F-FDG PET/CT, compared to contrast enhanced computed tomography (CT), in staging patients with ovarian cancer. PATIENTS...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3281afa256

    authors: Castellucci P,Perrone AM,Picchio M,Ghi T,Farsad M,Nanni C,Messa C,Meriggiola MC,Pelusi G,Al-Nahhas A,Rubello D,Fazio F,Fanti S

    更新日期:2007-08-01 00:00:00

  • Performance of a single crystal digital gamma camera for first pass cardiac studies.

    abstract::First pass radionuclide angiocardiography (FPRNA) has gained increasing interest because of the development of new 99Tcm-labelled perfusion agents and of new 191Os/191Irm generator systems. The aim of the study was to evaluate the performance capacities of a small field of view single crystal digital gamma camera for ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199101000-00004

    authors: Dobbeleir A,Franken PR,Ham HR,Brihaye C,Guillaume M,Knapp FF,Vandevivere J

    更新日期:1991-01-01 00:00:00

  • Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    abstract:OBJECTIVES:Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. MATERIALS AND METHODS:An audit o...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000064

    authors: Iball GR,Tout D

    更新日期:2014-04-01 00:00:00

  • A method of radionuclide angiography and comparison with contrast aortography in the assessment of aorto-iliac disease.

    abstract::Forty-four patients with symptoms of lower limb arterial insufficiency were examined by radionuclide angiography using 99Tcm in vivo red cell labelling and by contrast aortography. The results of the study indicate that radionuclide angiography may well have a useful role to play in determining the type of contrast st...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198601000-00006

    authors: Grime JS,Critchley M,Whitehouse GH,Zavras G

    更新日期:1986-01-01 00:00:00

  • Totally automatic definition of renal regions of interest from 99mTc-MAG3 renograms: validation in patients with normal kidneys and in patients with suspected renal obstruction.

    abstract:INTRODUCTION:An image-processing algorithm (AUTOROI) has been developed to totally automatically (or with manual assistance) detect whole-kidney contours and generate renal regions of interest (ROI) for the extraction of the quantitative measurements used in the interpretation of Tc-mercaptoacetyltriglycine (Tc-MAG3) r...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283362aa3

    authors: Garcia EV,Folks R,Pak S,Taylor A

    更新日期:2010-05-01 00:00:00

  • Evaluation of combined cardiac positron emission tomography and coronary computed tomography angiography for the detection of coronary artery disease.

    abstract:BACKGROUND:Coronary artery disease is a leading cause of morbidity and mortality. Multiple imaging modalities are used to screen for significant coronary artery disease. We report the concordance between coronary computed tomography angiography (CTA) and stress cardiac positron emission tomography (CPET) to detect sign...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f8143b

    authors: Adams GL,Trimble MA,Brosnan RB,Russo CA,Rusband D,Honeycutt EF,Shaw LK,Hurwitz LM,Turkington TG,Hanson MW,Pagnanelli RA,Borges-Neto S

    更新日期:2008-07-01 00:00:00

  • Stress-only myocardial perfusion scintigraphy: a prospective study on the accuracy and observer agreement with quantitative coronary angiography as the gold standard.

    abstract:OBJECTIVE:Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. PATIENTS AND METHODS:A total of 109 patients with typical angina and no previous coronary artery di...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0000000000000739

    authors: Ejlersen JA,May O,Mortensen J,Nielsen GL,Lauridsen JF,Allan J

    更新日期:2017-11-01 00:00:00

  • Recovery of renal retention function by differentiating the Patlak-Rutland plot.

    abstract:INTRODUCTION:It has been suggested that renal retention function can be estimated by differentiation of the Patlak-Rutland plot. AIM:To evaluate the error resulting from this method. METHODS:A total of 5800 renograms were generated by convolving real input functions with artificial retention functions. Ten bi-exponen...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200405000-00012

    authors: Kuyvenhoven JD,Ham HR,Piepsz A

    更新日期:2004-05-01 00:00:00

  • The effects of informational intervention on state anxiety and satisfaction in patients undergoing bone scan.

    abstract::The aim of the study was to identify the most beneficial mode, in terms of anxiety reduction, of giving patients information prior to them undergoing a bone scan. (Research has identified the scan procedure as having a demonstrative effect on anxiety.) Additionally, satisfaction with the adequacy of the information wa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199411000-00011

    authors: Leckie J

    更新日期:1994-11-01 00:00:00

  • Does renal damage occur after the administration of 32P for palliation of pain from skeletal metastases?

    abstract::In normal adults, the maintenance of phosphate balance involves the reabsorption of 85-90% of filtered phosphate by the proximal tubule. At a glomerular filtration rate (GFR) of 125 ml min-1 and a plasma phosphate concentration of 1.3 mmol l-1, the filtered phosphate is approximately 235 mmol day-1. Following intraven...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199807000-00011

    authors: Nair N,Mahadeo DS,Patel R

    更新日期:1998-07-01 00:00:00

  • Kinetic analysis of 99mTc-sestamibi evaluates the protective effects by ischaemic preconditioning on ischaemic myocardium in an isolated rabbit heart.

    abstract:OBJECTIVE:To analyse the kinetic changes of uptake, washout and retention of Tc-sestamibi in order to evaluate the protective effects and possible mechanism of ischaemic preconditioning and adenosine preconditioning on myocardium injured by ischaemia/reperfusion. METHODS:Isolated ischaemia/reperfusion rabbit heart mod...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3282f1781b

    authors: Liang J,Chen HL,Zhou Y,Xie M,Xu LM,Lin G

    更新日期:2007-11-01 00:00:00