Evaluation of post-stress left ventricular dysfunction and its relationship with perfusion abnormalities using gated SPECT in patients with cardiac syndrome X.

Abstract:

OBJECTIVE:Cardiac syndrome X defines patients with typical angina, a positive exercise ECG stress test and angiographically documented normal coronary arteries. In previous studies, post-stress prolonged left ventricular dysfunction (PLVD) using gated SPECT (G-SPECT) had been well correlated with myocardial perfusion abnormalities and degree of stenotic vessels in CAG in patients with coronary artery disease. However, evaluation of left ventricular myocardial perfusion, wall motion and left ventricular ejection fraction (LVEF) in patients with cardiac syndrome X, using G-SPECT had not been studied yet. Thus, the aim of this study was to analyse PLVD using (99m)Tc-MIBI GSPECT in patients with cardiac syndrome X. METHODS:Of the patients in whom G-SPECT was performed in our institution between 2004 and 2006, 17 patients with anginal chest pain, positive exercise ECG stress test and normal coronary angiograms were retrospectively included to the study (group I). Fifteen patients with normal myocardial perfusion and another 15 patients with ischaemia on G-SPECT were selected as control groups (groups II and III). (99m)Tc-MIBI G-SPECT was performed for all patients according to 2 day (stress-rest) protocol. Stress and rest LVEF were derived automatically (SLVEF and RLVEF). Difference LVEF (DLVEF) (stress-rest) was calculated. Semiquantitative analyses were made both for myocardial perfusion and wall motion (WM), using a 20-segment model and a 5-point scoring system. DLVEF, perfusion and WM scores of all groups were compared among three groups and relationship between DLVEF, perfusion and WM scores were evaluated. RESULTS:Abnormal perfusion were detected in eight (47.1%) of patients, while the remaining nine (52.9%) had normal myocardial perfusion, in group I. Six of 17 (35.3%) patients in group I had post-stress WM abnormalities. Mean of DLVEF values were -3.1+/-3.0%, 4.4+/-2.0% and -6.0+/-5.1% in groups I, II and III, respectively (P<0.05 for group II vs. group I and group III; P>0.05 for group I vs. group III). LVEF response impairment (< or =5% increase from rest to post-stress images) was found in 17 (100%), seven (46.6%), 14 (93.3%) of patients in groups I, II and III, respectively. CONCLUSION:Abnormal myocardial perfusion, concordant transient segmental WM abnormalities and LVEF response impairment are not uncommon in patients with cardiac syndrome X of this cohort of the study population. Therefore, post-stress prolonged stunning may be attributed to these findings in some of cardiac syndrome X patients as in true ischaemic patients. However, further studies with larger number of subjects and long-term follow-up are necessary to support these findings.

journal_name

Nucl Med Commun

authors

Demir H,Kahraman G,Isgoren S,Tan YZ,Kilic T,Berk F

doi

10.1097/MNM.0b013e3282f52c49

subject

Has Abstract

pub_date

2008-03-01 00:00:00

pages

208-14

issue

3

eissn

0143-3636

issn

1473-5628

pii

00006231-200803000-00003

journal_volume

29

pub_type

杂志文章
  • A review of PET normalization: striving for count rate uniformity.

    abstract::The advent of PET instrumentation signaled the beginning of a new perspective in nuclear medicine diagnostic imaging. PET systems rely on several corrections that must be applied in order to establish accurate and reliable quantification. The inherent properties of PET detector architecture and the crystals themselves...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/MNM.0b013e328365ac1e

    authors: Theodorakis L,Loudos G,Prassopoulos V,Kappas C,Tsougos I,Georgoulias P

    更新日期:2013-11-01 00:00:00

  • Scintigraphic assessments of the reparative process in osteonecrosis of the femoral head using SPECT/CT with 99mTc hydroxymethylene diphosphonate.

    abstract:OBJECTIVE:The aim of the study was to assess the degree and location of the reparative process in early osteonecrosis of the femoral head on the basis of single-photon emission computed tomography/computed tomography (SPECT/CT) with technetium-99m hydroxymethylene diphosphonate. MATERIALS AND METHODS:This study was ap...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000166

    authors: Motomura G,Yamamoto T,Abe K,Nakashima Y,Ohishi M,Hamai S,Doi T,Honda H,Iwamoto Y

    更新日期:2014-10-01 00:00:00

  • Accuracy of gated equilibrium radioventriculography in measuring left ventricular function in dogs.

    abstract::To assess the precision of gated equilibrium radioventriculography in measuring changes in left ventricular stroke volume (LVSV), we studied five dogs each with a chronically implanted electromagnetic flowmeter on the ascending aorta. Per cent changes in left ventricular stroke counts (LVSC) were compared to those in ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198812000-00009

    authors: Valette H,Bourguignon MH,Apoil E,Moyse D,Wise RA,Buchanan JW,Wagner HN Jr,Syrota A

    更新日期:1988-12-01 00:00:00

  • Recombinant human thyrotropin (rhTSH) in the management of differentiated thyroid cancer.

    abstract::Recombinant human thyrotropin (rhTSH) has been evaluated in 38 patients with differentiated thyroid cancer. The patients had all been treated previously by operation and 31 had received radioiodine 131I. The patients continued to take thyroid hormone and changed to a low iodine diet for 14 days before and throughout t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200006000-00004

    authors: Durski JM,Weigel RJ,McDougall IR

    更新日期:2000-06-01 00:00:00

  • Left ventricular function and the distribution of pulmonary and total blood volume in hypertensive and normotensive man.

    abstract::Using radionuclide methods the relationship between total and central blood volume and left ventricular function was studied in 12 patients with untreated essential hypertension and contrasted with the findings in eight normotensive subjects. The principal findings were of an increased stroke volume and end-diastolic ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198410000-00002

    authors: Mackay I,Nath K,Watson ML,Hannan WJ,Muir AL

    更新日期:1984-10-01 00:00:00

  • The early plasma concentration of 51Cr-EDTA in patients with cirrhosis and ascites: a comparison of three models.

    abstract:OBJECTIVES:The aim of the study was to determine which of three two-parameter fitting functions (exponential, linear-log, and negative-power function of time) most accurately models early chromium-51-EDTA (51Cr-EDTA) plasma concentration data prior to 120 min in patients with cirrhosis and ascites and understand how th...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000255

    authors: Wanasundara SN,Wesolowski MJ,Puetter RC,Burniston MT,Xirouchakis E,Giamalis IG,Babyn PS,Wesolowski CA

    更新日期:2015-04-01 00:00:00

  • The usefulness of fluorine-18 fluorodeoxyglucose PET in the detection of recurrence in patients with differentiated thyroid cancer with elevated thyroglobulin and negative radioiodine whole-body scan.

    abstract:INTRODUCTION:PET/computed tomography (CT) using fluorine-18 fluorodeoxyglucose (F-FDG) has been used in the diagnosis of recurrence and metastases of differentiated thyroid cancer (DTC) in cases of negative whole-body scan (WBS) despite elevated concentrations of stimulated thyroglobulin (Tg). AIM:To assess the utilit...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000563

    authors: Stangierski A,Kaznowski J,Wolinski K,Jodlowska E,Michaliszyn P,Kubiak K,Czepczynski R,Ruchala M

    更新日期:2016-09-01 00:00:00

  • Molecular biological correlation of fluorine-18 fluorodeoxyglucose uptake in esophageal squamous cell carcinoma.

    abstract:OBJECTIVE:The aim of this study was to assess the relationship between fluorine-18 fluorodeoxyglucose (F-FDG) uptake and molecular biological markers in esophageal squamous cell carcinoma (ESCC) patients. METHODS:Our patient population included 51 patients who underwent F-FDG PET/computed tomography before surgery. Ex...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000550

    authors: Hirose Y,Kaida H,Kawahara A,Matono S,Tanaka T,Kurata S,Kage M,Ishibashi M,Abe T

    更新日期:2016-10-01 00:00:00

  • Time course of thyroglobulin autoantibodies in patients with differentiated thyroid carcinoma after radioiodine therapy.

    abstract::The time course of thyroglobulin (Tg) was monitored in patients with differentiated thyroid carcinoma after ablative therapy (thyroidectomy + 131I-treatment) with particular respect to endogeneous antibodies (Tg-ABs). In 232 patients (196 without Tg-ABs, 36 with Tg-ABs at the time of treatment) a sensitivity of 88% (a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198405000-00003

    authors: Moser E,Braun S,Kirsch CM,Kleinhans E,Buell U

    更新日期:1984-05-01 00:00:00

  • Myocardial perfusion imaging versus biochemical markers in acute coronary syndromes.

    abstract::The assessment and appropriate clinical management of patients with acute chest pain and non-diagnostic electrocardiograms remain a continuing clinical problem. Accordingly, there is considerable interest in evaluating new strategies to improve early diagnostic accuracy in patients with possible acute myocardial ischa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200310000-00004

    authors: Anand DV,Lahiri A

    更新日期:2003-10-01 00:00:00

  • In vivo evaluation of three different 99mTc-labelled radiopharmaceuticals for sentinel lymph node identification.

    abstract::This work was designed to compare sentinel lymph node (SLN) uptake of 99mTc-labelled human serum albumin colloid (99mTc-HSAC), 99mTc-labelled antimony sulphur colloid (99mTc-SC) and a 99mTc-labelled dextran 70 solution (99mTc-Dx) and their selectivity in the identification of this node in the right rear footpad (RRF) ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200105000-00006

    authors: Edreira MM,Colombo LL,Perez JH,Sajaroff EO,de Castiglia SG

    更新日期:2001-05-01 00:00:00

  • Using the slope-only technique and estimated glomerular filtration rate for checking the reliability of slope-intercept measurement of glomerular filtration rate.

    abstract:AIM:To develop a strategy for checking the reliability of slope intercept measurement of glomerular filtration rate (GFR). METHODS:Six blood samples, obtained bilaterally 20-240 min after the injection of Cr-ethylenediaminetetraacetic acid (EDTA) and iohexol into opposite arms, were assayed for indicator injected cont...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328310b378

    authors: Bird NJ,Peters C,Michell AR,Peters AM

    更新日期:2008-12-01 00:00:00

  • 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease.

    abstract::The ability of 99Tcm-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients (45 male, 11 female, aged 55 +/- 5 years), with clinically recognized ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ve...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199212000-00004

    authors: Sciammarella MG,Fragasso G,Gerundini P,Maffioli L,Cappelletti A,Margonato A,Savi A,Chierchia S

    更新日期:1992-12-01 00:00:00

  • Assessment of the relationship between coronary flow rates and myocardial perfusion abnormality in patients with nonobstructive coronary artery disease: an observational study in cardiac syndrome X and coronary slow flow.

    abstract:OBJECTIVES:In this study, we evaluated and compared the level of myocardial ischaemia caused by cardiac syndrome X (CSX) and coronary slow flow (CSF) with single photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), and determined if changes in the level of myocardial ischaemia exist in CSF and ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001080

    authors: Özde C,Aktüre G,Aytekin S,Sayin AE,Ay EK,Coçkun G,Kaya A,Kayapinar O

    更新日期:2019-11-01 00:00:00

  • 177Lu-DOTATATE therapy in patients with neuroendocrine tumours including high-grade (WHO G3) neuroendocrine tumours: response to treatment and long-term survival update.

    abstract:PURPOSE:Upon diagnosis, distant metastases are encountered in 21-50% of neuroendocrine tumours (NETs). However, few systemic treatment options are available for the well-differentiated NETs in the metastatic stage. Lu-DOTATATE is one of the most effective treatments in this limited patient group. We retrospectively inv...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000874

    authors: Demirci E,Kabasakal L,Toklu T,Ocak M,Şahin OE,Alan-Selcuk N,Araman A

    更新日期:2018-08-01 00:00:00

  • Are there normal values of phase analysis parameters for left ventricular dyssynchrony in patients with no structural cardiomyopathy?: a systematic review.

    abstract:BACKGROUND:ECG-gated single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy combined with phase analysis allows for the assessment of left ventricular dyssynchrony. However, there are several software programs available thereby introducing variability in outcome and normal values. The aim ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001068

    authors: Marques de Souza Filho E,Tinoco Mesquita C,Altenburg Gismondi R,de Amorim Fernandes F,Jan Verberne H

    更新日期:2019-10-01 00:00:00

  • Optimization of the radiosynthesis of [68Ga]Ga-PSMA-11 using a Trasis MiniAiO synthesizer: do we need to heat and purify?.

    abstract::INTRODUTION:: [Ga]Ga-prostate specific membrane antigen (PSMA)-11 showed a clear gain in sensitivity for lesion detection in the biological recurrence of prostate cancer as compared to the standard [F]fluorocholine radiopharmaceutical. To meet the strong demand for [Ga]Ga-PSMA-11, we aimed to optimize an automated rad...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001233

    authors: Reverchon J,Khayi F,Roger M,Moreau A,Kryza D

    更新日期:2020-06-18 00:00:00

  • False-positive F-18 FDG uptake in PET/CT studies in pediatric patients with abdominal Burkitt's lymphoma.

    abstract:INTRODUCTION:In pediatric patients with abdominal Burkitt's lymphoma, the involvement of the gastrointestinal tract and abdominal lymph nodes are the main presenting feature of the disease. Chemotherapy is the main treatment modality and could be preceded by surgical excision of the abdominal masses. To achieve cure or...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328334fc14

    authors: Riad R,Omar W,Sidhom I,Zamzam M,Zaky I,Hafez M,Abdel-Dayem HM

    更新日期:2010-03-01 00:00:00

  • Pulmonary perfusion assessment with respiratory gated 99mTc macroaggregated albumin SPECT: preliminary results.

    abstract:PURPOSE:Respiratory gated perfusion single photon emission computed tomography (SPECT) was applied to reduce respiratory lung motion effects and to reliably assess perfusion impairment in various lung diseases. METHODS:After injection of 259 MBq of 99mTc macroaggretated albumin (99mTc-MAA), gating was performed using ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200402000-00016

    authors: Suga K,Kawakami Y,Zaki M,Yamashita T,Matsumoto T,Matsunaga N

    更新日期:2004-02-01 00:00:00

  • A meta-analysis of scintimammography: an evidence-based approach to its clinical utility.

    abstract:BACKGROUND:Scintimammography using (99m)Tc-labelled isonitriles, sestamibi and tetrofosmin, has become a mature technique in the adjunctive setting for the diagnosis of primary breast cancer. To establish an evidence base for its use, clinically, a meta-analysis was performed on both single-site and multi-centre trials...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,meta分析,评审

    doi:10.1097/00006231-200607000-00007

    authors: Hussain R,Buscombe JR

    更新日期:2006-07-01 00:00:00

  • Myocardial fatty acid imaging with 123I-labelled 9-methyl-branched pentadecanoic acid (9MPA) using SPET.

    abstract::123I-labelled 15-(p-iodophenyl)-9-(R,S)-methylpentadecanoic acid (9MPA) is a modified long-chain fatty acid that shows some beta-oxidation. Some basic aspects of this fatty acid, including myocardial uptake, distribution, clearance and differences from 201Tl myocardial perfusion, have yet to be evaluated. An average o...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199809000-00004

    authors: Nakajima K,Taki J,Yamamoto W,Takata S,Shimizu M,Tonami N

    更新日期:1998-09-01 00:00:00

  • PET-CT imaging features that differentiate between positive and negative EWSR1 translocation in Ewing sarcoma.

    abstract:OBJECTIVES:Ewing sarcoma breakpoint region 1 (EWSR1) translocation-negative tumors represent a minor portion of small round cell tumors consistent with Ewing sarcoma morphology. The purpose of this study was to differentiate EWSR1 translocation-positive tumors from EWSR1 translocation-negative tumors using PET-computed...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001031

    authors: Soffer S,Amitai MM,Weizen R,Retter A,Barshack I,Shimon O,Davidson T,Klang E

    更新日期:2019-08-01 00:00:00

  • Non-invasive quantification of cerebral blood flow for rats by microPET imaging of 15O labelled water: the application of a cardiac time-activity curve for the tracer arterial input function.

    abstract:OBJECTIVE:In-vivo quantitative cerebral blood flow (CBF) measurement using positron emission tomography (PET) has typically employed invasive arterial blood sampling procedure to determine the arterial input function (AIF). The present study was performed to provide a non-invasive quantitative CBF measurement technique...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200510000-00009

    authors: Yee SH,Jerabek PA,Fox PT

    更新日期:2005-10-01 00:00:00

  • Validation set analysis to predict postoperative outcomes by technetium-99m galactosyl serum albumin scintigraphy for hepatectomy.

    abstract:BACKGROUND:The indocyanine green retention rate at 15 min (ICGR15) is a gold standard parameter of liver function when deciding on the extent of hepatectomy. However, ICGR15 is influenced by several hepatic conditions. To evaluate auxiliary preoperative liver functional reserve, we examined the clinical significance of...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001162

    authors: Nanashima A,Hiyoshi M,Imamura N,Yano K,Hamada T,Wada T,Nishimuta M,Shimizu I,Mizutani Y

    更新日期:2020-04-01 00:00:00

  • Effect of administered activity on precision in the assessment of renal function using gamma camera renography.

    abstract::Split and total renal function are commonly assessed from time-activity curves obtained from gamma camera renography with 99Tcm-diethylenetriamine pentaacetate (99Tcm-DTPA) and 99Tcm-mercaptoacetyl-triglycine (99Tcm-MAG3). The impact of the statistical noise associated with these curves on the total precision in split...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199704000-00174

    authors: Moonen M,Jacobsson L

    更新日期:1997-04-01 00:00:00

  • A study of leucocyte labelling efficiencies obtained with 111In-oxine.

    abstract::The range of leucocyte labelling efficiencies with 111In-oxine for a group of patients extended significantly (P = 0.05) below that obtained for a series of labellings of the same normal blood from a volunteer. A retrospective analysis was made of the results in the two groups to identify the cause of this difference ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Mountford PJ,Allsopp MJ,Baird AC,North CI,Hall FM,Wells CP,Coakley AJ

    更新日期:1985-02-01 00:00:00

  • Incidental detection of apical hypertrophic cardiomyopathy by myocardial perfusion imaging.

    abstract:BACKGROUND:Echocardiography plays a central role in the diagnosis of hypertrophic cardiomyopathy (HCM). However, apical involvement of HCM may be missed because of foreshortening and inadequate clinical suspicion. These patients may be referred for single-photon emission computed tomography imaging. METHODS:We present...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328334fc41

    authors: Irwin RB,Arumugam P,Khattar RS

    更新日期:2010-04-01 00:00:00

  • Phase I/II clinical trial of the humanized anti-EGF-r monoclonal antibody h-R3 labelled with 99mTc in patients with tumour of epithelial origin.

    abstract:AIM:To evaluate the biodistribution, internal radiation dosimetry and toxicity of the humanized MAb h-R3 labelled with Tc in humans. METHODS:Twenty-five patients with suspected epithelial-derived tumours were included in this study and divided into two groups: group I consisted of 10 patients who received 3 mg/1110 MB...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200512000-00002

    authors: Torres LA,Perera A,Batista JF,Hernández A,Crombet T,Ramos M,Neninger E,Pérez M,Sánchez EL,Romero S,Aguilar V,Coca MA,Iznaga-Escobar N

    更新日期:2005-12-01 00:00:00

  • Specifying dual-detector gamma cameras and associated computer systems.

    abstract::Increasingly, dual-detector gamma cameras are being purchased as replacements for single-headed cameras. The improvement in sensitivity offered by a dual-detector device can be used in several ways: to shorten acquisition times, to improve signal-to-noise ratios, or to reduce administered doses. This paper focuses on ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-199507000-00003

    authors: Tindale WB

    更新日期:1995-07-01 00:00:00

  • Pretargeted gamma imaging of murine metastatic melanoma lung lesions with bispecific antibody and radiolabeled polymer drug conjugates.

    abstract:INTRODUCTION:Bispecific monoclonal antibodies (bsMAbs) have been developed as a pretargeting tool to reduce background activity, thereby increasing target to background (T : B) ratios. To enhance visualization of small lesions in vivo, we have used the pretargeting approach of bsMAb and negatively charged polymers radi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32834af77b

    authors: Gada KS,Patil V,Panwar R,Majewski S,Tekabe Y,Khaw BA

    更新日期:2011-12-01 00:00:00