Pancreatic cancer detected by positron emission tomography with 18F-labelled deoxyglucose: method and first results.

Abstract:

:In order to evaluate the utility of positron emission tomography (PET) with 18F-labelled deoxyglucose (FDG) for detection of pancreatic cancer 15 patients with pancreatic masses shown by computed tomography were investigated. Static PET scans covering an axial field of view of 15 cm were obtained 45 min after intravenous injection of 150-300 MBq FDG. Focally increased FDG accumulation was present in 12 out of 13 patients with histologically proven adenocarcinoma, in particular in eight of nine lymph node and four of five liver metastases. Scans of two patients with chronic pancreatitis confirmed by surgery revealed a normal FDG distribution. Contrast between tumour and normal tissue depended the metabolic situation prior to FDG injection. High ratios were found in fasting patients whereas no elevated FDG uptake was measured in an insulin-dependent diabetic suffering from carcinoma of the pancreatic head. We conclude that FDG PET might have the potential for detection and even differentiation of pancreatic carcinoma from chronic pancreatitis. Further studies are necessary to substantiate these preliminary findings and to optimize results in diabetic patients.

journal_name

Nucl Med Commun

authors

Bares R,Klever P,Hellwig D,Hauptmann S,Fass J,Hambuechen U,Zopp L,Mueller B,Buell U,Schumpelick V

doi

10.1097/00006231-199307000-00013

subject

Has Abstract

pub_date

1993-07-01 00:00:00

pages

596-601

issue

7

eissn

0143-3636

issn

1473-5628

journal_volume

14

pub_type

杂志文章
  • The appearance of the pyramidal lobe on thyroid scintigraphy.

    abstract::The standard nuclear medicine textbooks describe the pyramidal lobe of the thyroid as arising from the upper part of the thyroid lobes. Anatomy and surgical texts however describe it as a thyroglossal tract remnant and state that it arises from the isthmus. Review of 150 thyroid scintigrams confirms that on scintigrap...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198403000-00006

    authors: Savage PE,Khan O,Grover S,Ott R,McCready VR

    更新日期:1984-03-01 00:00:00

  • Acute myocardial infarction delineated by noninvasive thallium-201/technetium-99m pyrophosphate tomography.

    abstract::The purpose of this study was to validate different scintigraphic approaches for assessing acute myocardial infarctions. 201Tl, 99Tcm pyrophosphate (PPi) and combined 201Tl/99Tcm PPi tomograms were evaluated in 115 consecutive patients, in 85 of whom clinical examination revealed acute myocardial infarction. The overa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199009000-00005

    authors: Krause T,Joseph A,Kutzner C,Kasper W,Schuemichen C,Just H,Moser E

    更新日期:1990-09-01 00:00:00

  • Clinical value of cystatin C and beta-trace protein in glomerular filtration rate in renal transplant cases with stable renal graft functions: comparison by the 99mTc-DTPA plasma sample method.

    abstract:AIM:The aim of this study was to investigate the value of cystatin C and beta-trace protein (BTP) levels in determination of the glomerular filtration rate (GFR) by accepting the technetium-99m diethylenetriamine pentaacetic acid (Tc-DTPA) method as the gold standard for GFR measurement in renal transplant patients wit...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000116

    authors: Oner AO,Aydin F,Demirelli S,Budak ES,Davran F,Akbas H,Kocak H,Suleymanlar G,Gungor F

    更新日期:2014-07-01 00:00:00

  • Quantification in clinical fluorodeoxyglucose positron emission tomography.

    abstract::Positron emission tomography (PET) is increasingly used clinically to provide functional information on disease processes, especially in oncology using the glucose analogue 2-[18F]fluoro-2-deoxy-D-glucose (F-FDG). In the clinical setting it has become standard practice to use simplified imaging protocols compared to t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/01.mnm.0000134327.85170.6b

    authors: Hallett WA

    更新日期:2004-07-01 00:00:00

  • Predictive approaches for post-therapy PET/CT in patients with extranodal natural killer/T-cell lymphoma: a retrospective study.

    abstract:PURPOSE:The aim of this study was to assess the prognostic capacity of three methods of fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT analysis carried out after therapy in patients with extranodal natural killer/T-cell lymphoma (ENKTL). The three methods of PET/CT analysis included the International Harmonization Proje...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000731

    authors: Jiang C,Liu J,Li L,Kosik RO,Su M,Zou L,Tian R

    更新日期:2017-11-01 00:00:00

  • The impact of Ga-68 DOTATATE PET/CT imaging on management of patients with paragangliomas.

    abstract:OBJECTIVE:Paragangliomas are rare tumours of neural crest origin that express high levels of somatostatin receptor. Ga-68 DOTATATE PET/CT is a widely accepted method for imaging of neuroendocrine tumours. This study was performed to review a Ga-68 DOTATATE PET/CT patient database and to establish the impact of the moda...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001130

    authors: Skoura E,Priftakis D,Novruzov F,Caplin ME,Gnanasegaran G,Navalkissoor S,Bomanji J

    更新日期:2020-02-01 00:00:00

  • A 99Tcm-labelled leukotriene B4 receptor antagonist for scintigraphic detection of infection in rabbits.

    abstract::In a search for a rapid and accurate imaging agent for scintigraphic detection of infection and inflammation, an LTB4 receptor antagonist, 99Tcm-RP517, which contains the hydrazino nicotinamide moiety, has been developed recently. To study the in vivo behaviour of 99Tcm-RP517, rabbits with Escherichia coli infection w...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200011000-00010

    authors: Brouwers AH,Laverman P,Boerman OC,Oyen WJ,Barrett JA,Harris TD,Edwards DS,Corstens FH

    更新日期:2000-11-01 00:00:00

  • Evaluation of a matched filter resolution recovery reconstruction algorithm for SPECT-CT imaging.

    abstract:AIM:The aim of our study was to assess improvements in spatial resolution and noise control from the application of the Astonish resolution recovery algorithm for single photon emission computed tomography imaging. Secondary aims were to compare acquisitions made with low-energy general purpose collimators with those o...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32835ce5b5

    authors: O'Mahoney E,Murray I

    更新日期:2013-03-01 00:00:00

  • The structural failure of a multi-hole collimator.

    abstract::During measurements of the extrinsic spatial resolution of a gamma camera, it was noted that there was a variation with the position in the field of view. The problem was traced to the collimator, and this was confirmed by inspection of the parallel hole structure. Removal of the cover showed that the lead foil honeyc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200009000-00012

    authors: Harris AM,Ward RJ

    更新日期:2000-09-01 00:00:00

  • Immunoscintigraphy (BW 250/183) in neonates and infants with fever of unknown origin.

    abstract::Fever of unknown origin is defined as a temperature above 39.0 degrees C together with a white blood cell count > or = 15,000 mm-3, the duration of fever exceeding 2 weeks and a correct diagnosis not being obtained in the first week of hospitalization. In neonates and infants with fever of unknown origin, the localiza...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199811000-00003

    authors: Gratz S,Behr TM,Herrmann A,Meller J,Conrad M,Zappel H,Becker W

    更新日期:1998-11-01 00:00:00

  • The use of dual-isotope imaging to compare the gastrointestinal transit of food and pancreatic enzyme pellets in cystic fibrosis patients.

    abstract::Cystic fibrosis patients require pancreatic enzyme supplements to aid food digestion. It is suspected that incorrect delivery of this enzyme may result in both significant malabsorption and the development of strictures in the proximal colon caused by the high-dose supplement reaching this region before the food. Inve...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199808000-00006

    authors: Hillel PG,Tindale WB,Taylor CJ,Frier M,Senior S,Ghosal S

    更新日期:1998-08-01 00:00:00

  • Stunning phenomenon after a radioactive iodine- ¹³¹I diagnostic whole-body scan: Is it really a point of clinical consideration?

    abstract:PURPOSE:Stunning of thyroid remnants after diagnostic scanning (Dx-WBS) using radioactive iodine- (¹³¹I) may limit the efficacy of I therapy. We aimed to evaluate this assumption in a prospectively designed study. METHODS:Forty patients who underwent thyroidectomy for differentiated thyroid carcinoma were studied and ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e328362ad63

    authors: Amin A,Amin M,Badwey A

    更新日期:2013-08-01 00:00:00

  • Augmentation of parathyroid 201Tl/99Tcm scanning by infusion of trisodium edetate.

    abstract::A significant number of patients with primary hyperparathyroidism have negative preoperative 201Tl/99Tcm subtraction localization scans. In this study an attempt was made to improve scan localization by creating a period of relative hypocalcaemia and increased parathyroid hormone (PTH) secretion before scanning. Six p...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199109000-00005

    authors: Gallacher SJ,Fraser WD,Logue FC,Boyle IT,Gray HW,McKillop JH

    更新日期:1991-09-01 00:00:00

  • Immediate 201Tl reinjection: an alternative approach in myocardial perfusion scintigraphy? A comparison with contrast angiographic findings.

    abstract::Thallium-201 (201Tl) stress-redistribution/reinjection imaging provides a reliable diagnostic approach in patients evaluated for myocardial ischaemia. Immediate reinjection of 201Tl after completing the stress images followed by imaging 1 h later shortens the investigation time to 2.5 h and may provide a novel approac...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:

    authors: van Eck-Smit BL,van der Wall EE,Zwinderman AH,Pauwels EK

    更新日期:1995-10-01 00:00:00

  • Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas.

    abstract:OBJECTIVE:To verify the negative predictive value of pulmonary ventilation/perfusion scintigraphy with single photon emission computed tomography (V/Q SPECT) in ruling out pulmonary thromboembolism. METHODS:V/Q SPECT using 99mTc-Technegas was performed on 584 patients to rule out pulmonary thromboembolism between Octo...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e32827a8e99

    authors: Leblanc M,Leveillée F,Turcotte E

    更新日期:2007-08-01 00:00:00

  • Prediction of lymph node metastasis by PET/CT metabolic parameters in patients with esophageal squamous cell carcinoma.

    abstract:OBJECTIVE:The aim of this study was to investigate the capability of F-FDG PET/computed tomography (CT)-related metabolic parameters to predict lymph node metastasis (LNM) and occult lymph node metastasis (OLNM) in patients with esophageal squamous cell carcinoma (ESCC). METHODS:Totally 84 patients undergoing curative...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001050

    authors: Xu M,Wang L,Ouyang M,Lin J,Wang L,Zheng X,Miao S,Tang K

    更新日期:2019-09-01 00:00:00

  • Localization of parathyroid disease with 'sequential multiphase and dual-tracer' technique and comparison with neck ultrasound.

    abstract:OBJECTIVE:The aim of the study was to evaluate the accuracy of the sequential multiphase and dual-tracer (SMADT) technique utilizing technetium-99m pertechnetate (99mTcO4) and dynamic technetium-99m-2-methoxyisobutylisonitrile (99mTc-MIBI) with single-photon emission computed tomography/computed tomography (SPECT/CT) f...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000215

    authors: Berner AM,Haroon A,Nowosinska E,Offiah C,Luqman M,Newell M,Jan H

    更新日期:2015-01-01 00:00:00

  • Evaluation of different normalization procedures for the calculation of the standardized uptake value in therapy response monitoring studies.

    abstract:OBJECTIVES:The aim of this prospective study was to assess the influence of different normalization procedures on relative changes in standardized uptake values (SUV) of F-2-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) for the assessment of chemotherapy response in patients with colorectal carcinoma ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e32832bdc80

    authors: Vriens D,de Geus-Oei LF,van Laarhoven HW,Timmer-Bonte JN,Krabbe PF,Visser EP,Oyen WJ

    更新日期:2009-07-01 00:00:00

  • Quantitative assessment of cardiac mechanical dyssynchrony and prediction of response to cardiac resynchronization therapy in patients with nonischaemic dilated cardiomyopathy using gated myocardial perfusion SPECT.

    abstract:OBJECTIVE:The aim of the study was to evaluate gated myocardial perfusion SPECT (GMPS) in the prediction of response to cardiac resynchronization therapy (CRT) in nonischaemic dilated cardiomyopathy patients. PATIENTS AND METHODS:Thirty-two patients (23 men, mean age 57.5±12.1 years) with severe heart failure, who wer...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0000000000000282

    authors: Mukherjee A,Patel CD,Naik N,Sharma G,Roy A

    更新日期:2015-05-01 00:00:00

  • Measurement uncertainty of lesion and reference mediastinum standardized uptake value in lung cancer.

    abstract:OBJECTIVE:To assess standardized uptake value (SUV) measurement uncertainty (MU) of lung cancer lesions with uptake greater than mediastinum but less than or equal to the liver and that of the mediastinum blood pool, and to compare lesion SUV with mediastinum SUV by assessing MU of their ratio. PATIENTS AND METHODS:Dy...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000677

    authors: Laffon E,Milpied N,Marthan R

    更新日期:2017-06-01 00:00:00

  • Thyroid lobe ablation with iodine- ¹³¹I in patients with differentiated thyroid carcinoma: a randomized comparison between 1.1 and 3.7 GBq activities.

    abstract:PURPOSE:The present study was undertaken to evaluate the ablation rate after administration of 1.1 or 3.7 GBq of iodine- (¹³¹I) to patients with low-risk differentiated thyroid carcinoma (DTC) primarily treated by lobectomy. PATIENTS AND METHODS:Enrolled were 136 consecutive patients affected by histologically proven ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/MNM.0b013e3283622f3d

    authors: Giovanella L,Piccardo A,Paone G,Foppiani L,Treglia G,Ceriani L

    更新日期:2013-08-01 00:00:00

  • Clinical competence in myocardial perfusion scintigraphic stress testing: general training guidelines and assessment.

    abstract::The suggestion by the National Institute for Clinical Excellence (NICE) to more than triple the number of myocardial perfusion scintigraphy (MPS) procedures carried out by the NHS each year is a challenge both in terms of numbers of gamma cameras available to carry out the scans and qualified staff to supervise stress...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,实务指引

    doi:10.1097/MNM.0b013e32818a6e72

    authors: Jones I,Latus K,Bartle L,Gardner M,Parkin V,Guideline Development and Writing Group, British Nuclear Medicine Society and British Nuclear Cardiac Society.

    更新日期:2007-07-01 00:00:00

  • Morphine-augmented hepatobiliary scintigraphy: a meta-analysis.

    abstract::The aim of this study was to compare the sensitivity and specificity of morphine-augmented hepatobiliary scintigraphy (MA-HBS) with that of conventional hepatobiliary scintigraphy (C-HBS) for acute cholecystitis. The results of most MA-HBS studies cannot be compared with C-HBS estimates, since articles describing C-HB...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199512000-00013

    authors: Cabana MD,Alavi A,Berlin JA,Shea JA,Kim CK,Williams SV

    更新日期:1995-12-01 00:00:00

  • GFR measurement by simulating constant infusion with data acquired using a CdTe detector. A feasibility study.

    abstract::Conventional nuclear medicine methods for measuring glomerular filtration rate, GFR, are invalidated if the initial injection of radiopharmaceutical is tissued. An analytical method proposed by Veall and Gibbs in 1982 overcomes this difficulty but does require multiple blood samples. This paper investigates whether it...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198611000-00003

    authors: Casey M,Barker F,Duffy G

    更新日期:1986-11-01 00:00:00

  • 99Tcm-methoxy-isobutyl-isonitrile SPECT to evaluate a perfusion index from regional myocardial uptake after exercise and at rest. Results of a four hour protocol in patients with coronary heart disease and in controls.

    abstract::In 70 patients with angiographically confirmed coronary heart disease and in 10 controls, a 4 h exercise (E) (injection of 150 MBq 99Tcm-MIBI) rest (R) (800 MBq) protocol was employed. Of these, 10 patients with 21 myocardial defects after E received a third injection 24 h after. SPECT was used to image myocardial dis...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199002000-00002

    authors: Buell U,Dupont F,Uebis R,Kaiser HJ,Kleinhans E,Reske SN,Hanrath P

    更新日期:1990-02-01 00:00:00

  • Formulation and characterization of lutetium-177-labeled stannous (tin) colloid for radiosynovectomy.

    abstract:OBJECTIVE:Easy large-scale production, easy availability, cost-effectiveness, long half-life, and favorable radiation characteristics have made lutetium-177 (Lu) a preferred radionuclide for use in therapy. Lutetium-177-labeled stannous (Lu-Sn) colloid particles were formulated for application in radiosynovectomy, foll...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000684

    authors: Arora G,Singh M,Jha P,Tripathy S,Bal C,Mukherjee A,Shamim SA

    更新日期:2017-07-01 00:00:00

  • Myocardial perfusion imaging versus biochemical markers in acute coronary syndromes.

    abstract::The assessment and appropriate clinical management of patients with acute chest pain and non-diagnostic electrocardiograms remain a continuing clinical problem. Accordingly, there is considerable interest in evaluating new strategies to improve early diagnostic accuracy in patients with possible acute myocardial ischa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200310000-00004

    authors: Anand DV,Lahiri A

    更新日期:2003-10-01 00:00:00

  • Spontaneous variability of left ventricular ejection fraction assessed with the Cardioscint.

    abstract::A miniature, non-imaging caesium iodide nuclear probe optically coupled to a photodiode (the 'Cardioscint') has been developed which, in conjunction with a modified personal computer, is capable of continuous on-line monitoring of left ventricular function and ST-segment level at the bedside. The purpose of this study...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199205000-00004

    authors: Broadhurst P,Liu XJ,Cashman PM,Raftery EB,Lahiri A

    更新日期:1992-05-01 00:00:00

  • Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging.

    abstract:OBJECTIVES:The purpose of this study was to compare quantitative ECG-gated single-photon emission computed tomography (SPECT) (QGS) and model-based ECG-gated single-photon emission computed tomography (MBGS) for determination of end-diastolic cardiac volume (EDV), end-systolic cardiac volume (ESV), and left ventricular...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283294d19

    authors: Khorsand A,Gyöngyösi M,Graf S,Zamini S,Schuster E,Sochor H,Porenta G

    更新日期:2009-04-01 00:00:00

  • Quantifying the value of diagnostic tests.

    abstract::This paper considers the different statistics that can be derived from studies on the value of diagnostic tests. Well-accepted quantities, such as sensitivity and specificity, are reviewed and the value of the likelihood ratio in communicating particular test results is highlighted. A new quantity, the 'diagnostic val...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-199810000-00010

    authors: Lloyd JJ,Talbot PR,Lawson RS

    更新日期:1998-10-01 00:00:00