Reproducibility--an important factor determining the quality of computer-aided detection (CAD) systems.

Abstract:

PURPOSE:To test the reproducibility of markings on mammography films set by a commercial computer aided detection (CAD) system. PATIENTS AND METHODS:One hundred unilateral mammography examinations (each in CC and MLO) of 100 patients with mammographically detected suspicious foci, which were histopathologically proven to be malignant, were scanned three times with the CAD system, retrospectively. Every fifth patient of the institutional tumor case sampler was enrolled in the study. Only cases with one visible lesion were included in the study. Reproducibility and sensitivity (in both the strict and the broader sense) were determined. Strict sensitivity means the correct set of markers in both images, whereas broader sensitivity means the correct set in at least one of the images. Sixteen of 100 malignancies were indicated by focal suspicious microcalcification clusters, 53 tumors by masses and 31 cases by both signs of breast cancer. The CAD evaluation was divided into only two different markers: one for microcalcifications and one for masses. Thus, 47 (16+31) tumor-induced microcalcifications and 84 (53+31) malignancy-related masses were checked using the CAD system. RESULTS:Eighteen of 100 unilateral mammography examinations revealed identical patterns in all three scans (18% reproducibility). Eleven of 47 suspicious focal microcalcification clusters and 43/84 masses were correctly marked on both mammographic views in all three CAD scans (strict and broader sensitivity, 23.4 and 51.1%, respectively). Six of 47 microcalcification clusters and 8/84 masses were totally missed in all images by the system (false negative rate, 12.8 and 9.6%, respectively). CONCLUSION:Reproducibility is essential for CAD systems. Currently, reproducibility of the used CAD system appears to be insufficient for clinical routine. Improvement of the system characteristics would make such systems valuable as a 'second reader' in clinical examination.

journal_name

Eur J Radiol

authors

Malich A,Azhari T,Böhm T,Fleck M,Kaiser WA

doi

10.1016/s0720-048x(00)00189-3

keywords:

subject

Has Abstract

pub_date

2000-12-01 00:00:00

pages

170-4

issue

3

eissn

0720-048X

issn

1872-7727

pii

S0720048X00001893

journal_volume

36

pub_type

杂志文章
  • Biliary complications after liver transplantation: Assessment with MR cholangiopancreatography and MR imaging at 3T device.

    abstract:PURPOSE:Our study was aimed to assess the diagnostic value of MR cholangiopancreatography (MRCP) and MR imaging at 3 T device when evaluating biliary adverse events after liver transplantation. MATERIALS AND METHODS:A series of 384 MR examinations in 232 liver transplant subjects with suspected biliary complications (...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.07.009

    authors: Boraschi P,Donati F,Pacciardi F,Ghinolfi D,Falaschi F

    更新日期:2018-09-01 00:00:00

  • Differentiation between benign and malignant colon tumors using fast dynamic gadolinium-enhanced MR colonography; a feasibility study.

    abstract:BACKGROUND:Colorectal cancer will present itself as a bowel obstruction in 16-23% of all cases. However, not all obstructing tumors are malignant and the differentiation between a benign and a malignant tumor can be difficult. The purpose of our study was to determine whether fast dynamic gadolinium-enhanced MR imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.033

    authors: Achiam MP,Andersen LP,Klein M,Løgager V,Chabanova E,Thomsen HS,Rosenberg J

    更新日期:2010-06-01 00:00:00

  • Background parenchymal enhancement and fibroglandular tissue on breast MRI in women with high genetic risk: Are changes before and after risk-reducing salpingo-oophorectomy associated with breast cancer risk?

    abstract:BACKGROUND:Parenchymal enhancement and fibroglandular tissue on breast MRI in women with high genetic risk: are changes before and after risk-reducing salpingo-oophorectomy associated with breast cancer risk? OBJECTIVE:To evaluate changes in the level of background parenchymal enhancement (BPE) and amount of fibroglan...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.10.030

    authors: Bermot C,Saint-Martin C,Malhaire C,Sebbag-Sfez D,Mouret-Fourme E,Carton M,Thibault FE

    更新日期:2018-12-01 00:00:00

  • Clinical utility of real-time ultrasound-multimodality fusion guidance for percutaneous biopsy of focal liver lesions.

    abstract:OBJECTIVES:To prospectively evaluate the clinical value of real-time ultrasonography (US)-computed tomography (CT)/magnetic resonance imaging (MRI) fusion imaging for percutaneous needle biopsy of focal liver lesions (FLLs), and to compare its biopsy success rate with that of conventional US-guided biopsy in a propensi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.04.002

    authors: Ahn SJ,Lee JM,Chang W,Lee SM,Kang HJ,Yang HK,Han JK

    更新日期:2018-06-01 00:00:00

  • Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization.

    abstract:OBJECTIVE:To assess the usefulness of the spectral curve slope of dual-energy CT (DECT) for differentiating between hepatocellular carcinoma (HCC), hepatic metastasis, hemangioma (HH) and cysts. METHODS:In total, 121 patients were imaged in the portal venous phase using dual-energy mode. Of these patients, 23 patients...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.07.009

    authors: Wang Q,Shi G,Qi X,Fan X,Wang L

    更新日期:2014-10-01 00:00:00

  • Image quality of mammographic systems.

    abstract::The image quality in mammography was evaluated for all the 56 equipment-image receptor combinations used in Finland with two phantoms containing test objects of three types and different sizes. We obtained 2-8 fold variations for the smallest sizes of the three objects (specks, fibres and masses) visible in the X-ray ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Karila KT

    更新日期:1987-08-01 00:00:00

  • Assessment of the diagnostic accuracy of T2*-weighted MR imaging for identifying hepatocellular carcinoma with liver explant correlation.

    abstract:BACKGROUND:T2*-weighted MRI may represent a novel method for identifying hepatocellular carcinoma (HCC). The goal of this study was to assess the diagnostic accuracy of T2*-weighted MRI for HCC with liver explant correlation. MATERIALS AND METHODS:A retrospective review identified 25 patients who had undergone liver t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.027

    authors: Hardie AD,Nance JW,Boulter DJ,Kizziah MK

    更新日期:2011-12-01 00:00:00

  • Complications of percutaneous stereotactic vacuum assisted breast biopsy system utilizing radio frequency.

    abstract:OBJECTIVE:The Breast Lesion Excision System (BLES) is a novel, automatic breast biopsy device that utilizes radiofrequency to excise suspicious non-palpable mammographic lesions. The purpose of the present prospective study is to report and evaluate the complications of this new technique. MATERIALS AND METHODS:In a t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.12.023

    authors: Al-Harethee W,Theodoropoulos G,Filippakis GM,Papapanagiotou I,Matiatou M,Georgiou G,Kalles V,Koulocheri D,Nonni A,Konstadoulakis MM,Manouras A,Zografos GC

    更新日期:2013-04-01 00:00:00

  • Measurement of canine pancreatic perfusion using dynamic computed tomography: influence of input-output vessels on deconvolution and maximum slope methods.

    abstract:OBJECTIVE:We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. METHODS:We examined nine beagles injected with iohexol (200 mgI kg(-1)) at 5.0 ml s(-1). The abdominal ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.06.016

    authors: Kishimoto M,Tsuji Y,Katabami N,Shimizu J,Lee KJ,Iwasaki T,Miyake Y,Yazumi S,Chiba T,Yamada K

    更新日期:2011-01-01 00:00:00

  • Interstitial lung abnormalities in treatment-naïve advanced non-small-cell lung cancer patients are associated with shorter survival.

    abstract:OBJECTIVE:Interstitial lung diseases are associated with increased risk of lung cancer. The prevalence of ILA at diagnosis of advanced non-small-cell lung cancer (NSCLC) and its impact on overall survival (OS) remain to be investigated. MATERIALS AND METHOD:The study included 120 treatment-naïve stage IV NSCLC patient...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.01.021

    authors: Nishino M,Cardarella S,Dahlberg SE,Araki T,Lydon C,Jackman DM,Rabin MS,Hatabu H,Johnson BE

    更新日期:2015-05-01 00:00:00

  • Carotid artery stenting and follow-up: value of 64-MSCT angiography as complementary imaging method to color-coded duplex sonography.

    abstract:PURPOSE:To compare 64-multi-slice-CT angiography (64-MSCTA) to color-coded duplex sonography (CCDS) in the follow-up after carotid artery stenting (CAS). METHODS:Thirty patients who had an MSCTA and CCDS examination prior and after CAS were included. Twelve closed-cell and 24 open-cell stents were implanted. Neointima...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.007

    authors: Nolz R,Wibmer A,Beitzke D,Gentzsch S,Willfort-Ehringer A,Lammer J,Thurnher M,Schoder M

    更新日期:2012-01-01 00:00:00

  • Differentiation between ductal carcinoma in situ and mastopathy using dynamic contrast-enhanced magnetic resonance imaging and a model of contrast enhancement.

    abstract::The purpose of this study was to retrospectively evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate between ductal carcinoma in situ (DCIS) and mastopathy by analyzing their time-intensity curves (TICs) using the two-compartment pharmacokinetic model with an ass...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.09.039

    authors: Nishiura M,Tamaki Y,Murase K

    更新日期:2011-12-01 00:00:00

  • Diagnostic accuracy of imaging methods for the diagnosis of skeletal malignancies: A retrospective analysis against a pathology-proven reference.

    abstract:OBJECTIVES:To examine the diagnostic accuracy of imaging modalities in skeletal tumours versus pathology reports. MATERIALS AND METHODS:Pathology reports of bone biopsies were compared to diagnostic imaging with X-ray, computed tomography (CT), magnetic resonance imaging (MRI), bone scintigraphy (BS), and (18)F-fluoro...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.10.012

    authors: Lange MB,Nielsen ML,Andersen JD,Lilholt HJ,Vyberg M,Petersen LJ

    更新日期:2016-01-01 00:00:00

  • Chest radiographic findings in childhood lipoid pneumonia following aspiration of animal fat.

    abstract::The pulmonary radiological manifestations of lipoid pneumonia following a cultural practice of forced feeding of rendered animal fat (ghee) in 24 Saudi children are described. The age range is 15 days to 11 years with 68% of cases being in infancy. The chest radiographic appearances encountered could be grouped into f...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90077-z

    authors: Annobil SH,Ogunbiyi AO,Benjamin B

    更新日期:1993-04-01 00:00:00

  • Angioseal versus manual compression for haemostasis following peripheral vascular diagnostic and interventional procedures--a randomized controlled trial.

    abstract::The aim of this study was to compare the angioseal device to manual compression for femoral artery puncture following peripheral vascular procedures, in the context of day case vascular procedures. One hundred patients were prospectively randomised to haemostasis using the angioseal device or manual compression follow...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2006.09.007

    authors: Upponi SS,Ganeshan AG,Warakaulle DR,Phillips-Hughes J,Boardman P,Uberoi R

    更新日期:2007-02-01 00:00:00

  • Value of MR-based radiomics in differentiating uveal melanoma from other intraocular masses in adults.

    abstract:PURPOSE:To assess the performance of machine learning (ML)-based magnetic resonance imaging (MRI) radiomics analysis for discriminating between uveal melanoma (UM) and other intraocular masses. METHODS:This retrospective study analyzed 245 patients with intraocular masses (165 UMs and 80 other intraocular masses). Rad...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109268

    authors: Su Y,Xu X,Zuo P,Xia Y,Qu X,Chen Q,Guo J,Wei W,Xian J

    更新日期:2020-10-01 00:00:00

  • Inferomedially projecting pneumatised secondary middle turbinate.

    abstract::Secondary middle turbinate (SMT), a rare variation of the nasal cavity, is a bony projection covered by soft tissue that arises from the lateral nasal wall. It is almost always bilateral and usually projects superomedially without any ostiomeatal unit obstruction. Herein, we report a case of bilateral inferomedially p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00447-8

    authors: Apaydin FD,Duce MN,Yildiz A,Eğilmez H,Ozer C,Talas UD

    更新日期:2002-07-01 00:00:00

  • Shadowing and reverberation artifacts in abdominal ultrasonography.

    abstract::The different features of 821 acoustic shadows recorded during abdominal US examinations were analysed to find out whether any of the features may be used in routine work to help to identify the often invisible structure casting the shadow. A constant shadow with closely spaced high level reverberation echoes is stron...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Suramo I,Päivänsalo M,Vuoria P

    更新日期:1985-05-01 00:00:00

  • Schwannoma of the trachea.

    abstract::We recently encountered a tracheal schwannoma presenting as a polypoid mass. Computed tomography (CT) was very effective in evaluation of the size, shape and site of this rare tumour. Furthermore, CT images in the prone position made it easy to exclude tumour extension into the mediastinum. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Ikezoe J,Sone S,Higashihara T,Morimoto S,Arisawa J,Kuriyama K,Monden Y,Nakahara K,Azuma T,Machi S

    更新日期:1986-02-01 00:00:00

  • Postoperative MR evaluation of chondral repair in the knee.

    abstract::Articular cartilage abnormalities of the knee are a cause of significant patient morbidity. Several surgical techniques have been developed to treat these lesions to improve patient symptoms and to delay or prevent the development of osteoarthritis. MRI has been shown to be an accurate non-invasive test for the evalua...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.01.022

    authors: Polster J,Recht M

    更新日期:2005-05-01 00:00:00

  • The evidence for carotid stenting versus carotid endarterectomy in symptomatic patients.

    abstract::Large randomized trials have demonstrated the value of surgical intervention for symptomatic carotid artery disease in stroke prevention. More recently trials have also demonstrated benefit in asymptomatic patients. However, the benefit of surgery comes with significant burden in terms of a risk of both stroke at the ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.ejrad.2006.05.022

    authors: Gaines PA

    更新日期:2006-10-01 00:00:00

  • Detection of biliary and vascular anatomy in living liver donors: value of gadobenate dimeglumine enhanced MR and MDCT angiography.

    abstract:OBJECTIVE:To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. METHODS:Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiog...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.07.001

    authors: Artioli D,Tagliabue M,Aseni P,Sironi S,Vanzulli A

    更新日期:2010-11-01 00:00:00

  • High-resolution MR imaging for nodal staging in rectal cancer: are there any criteria in addition to the size?

    abstract:PURPOSE:MR staging of nodal metastases in patients with rectal cancer using criteria based on size, shape and signal intensity can be difficult, because > or =50% of the nodes are less than 5 mm in size. Therefore new MR criteria were evaluated to see whether it can improve the MR assessment of nodal metastases in rect...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2003.12.005

    authors: Kim JH,Beets GL,Kim MJ,Kessels AG,Beets-Tan RG

    更新日期:2004-10-01 00:00:00

  • Clinical evaluation of a computer simulated prediction model of contrast enhancement of the liver in spiral CT.

    abstract:OBJECTIVE:A software program was developed simulating a compartmental model of blood circulation based on differential equations. The aim of this study was to compare software-simulated levels of hepatic enhancement with the true values in patients and to test how many patients reach the simulated hepatic enhancement l...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/S0720-048X(03)00217-1

    authors: Schöber W,Kopp A,Scherf C,Mehnert F,Heuschmid M,Duda SH,Claussen CD,Pereira P

    更新日期:2004-07-01 00:00:00

  • Assessment of cardiac implantable electric device lead perforation using a metal artifact reduction algorithm in cardiac computed tomography.

    abstract:PURPOSE:CT is considered the non-invasive gold standard for evaluating cardiac implantable electronic devices (CIEDs) lead perforation, but metal artifacts caused by the lead tip affect the image quality and make a definitive diagnosis challenging. We compared the performances of the metal artifact reduction (MAR) algo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109530

    authors: Kidoh M,Oda S,Nakato K,Sakabe D,Kanazawa H,Takashio S,Nakaura T,Nagayama Y,Sasao A,Hatemura M,Funama Y,Kaikita K,Tsujita K,Ikeda O,Azuma M,Hirai T

    更新日期:2021-01-09 00:00:00

  • Contrast enhanced ultrasound in liver imaging.

    abstract::Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2004.03.022

    authors: Nielsen MB,Bang N

    更新日期:2004-06-01 00:00:00

  • Diagnostic ultrasound equipment. Safety and dosimetry.

    abstract::A survey of present opinions on the safety of diagnostic ultrasound applications is presented together with some data on output levels. Physical mechanisms involved in potential adverse effects are described. Labelling requirements of the equipment are defined and specified. These requirements are contained in a recen...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Thijssen JM,van Beekum WT,Daniëls O,Koch CW,Lanćee CT,Somer JC,de Vlieger M,Wladimiroff JW

    更新日期:1989-02-01 00:00:00

  • Pulmonary lymphangioleiomyomatosis: analysis of disease manifestation by region-based quantification of lung parenchyma.

    abstract:PURPOSE:Lymphangioleiomyomatosis (LAM) is characterized by proliferation of smooth muscle tissue that causes bronchial obstruction and secondary cystic destruction of lung parenchyma. The aim of this study was to evaluate the typical distribution of cystic defects in LAM with quantitative volumetric chest computed tomo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.12.019

    authors: Theilig D,Doellinger F,Kuhnigk JM,Temmesfeld-Wollbrueck B,Huebner RH,Schreiter N,Poellinger A

    更新日期:2015-04-01 00:00:00

  • "One-stop-shop" staging: should we prefer FDG-PET/CT or MRI for the detection of bone metastases?

    abstract:AIM:The aim of this study was to compare the diagnostic accuracy of fully diagnostic, contrast-enhanced whole-body FDG-PET/CT and whole-body MRI for detection of bone metastases in patients suffering from newly diagnosed non-small cell lung cancer and malignant melanoma. MATERIAL AND METHODS:109 consecutive non-small ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.10.031

    authors: Heusner T,Gölitz P,Hamami M,Eberhardt W,Esser S,Forsting M,Bockisch A,Antoch G

    更新日期:2011-06-01 00:00:00

  • Diffusion tensor magnetic resonance imaging of glial brain tumors.

    abstract:AIM:To evaluate the author's experience with the use of diffusion tensor magnetic resonance imaging (DTI) on patients with glial tumors. METHODS:A retrospective evaluation of a group of 24 patients with glial tumors was performed. There were eight patients with Grade II, eight patients with Grade III and eight patient...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.030

    authors: Ferda J,Kastner J,Mukensnabl P,Choc M,Horemuzová J,Ferdová E,Kreuzberg B

    更新日期:2010-06-01 00:00:00