Complications of percutaneous stereotactic vacuum assisted breast biopsy system utilizing radio frequency.

Abstract:

OBJECTIVE:The Breast Lesion Excision System (BLES) is a novel, automatic breast biopsy device that utilizes radiofrequency to excise suspicious non-palpable mammographic lesions. The purpose of the present prospective study is to report and evaluate the complications of this new technique. MATERIALS AND METHODS:In a two year period, we used the BLES device in 132 consecutive patients (134 procedures) with non-palpable mammographic lesions. The inclusion criteria consisted of suspicious microcalcifications, solid lesions and asymmetric density. In order to retrieve an intact biopsy specimen, we used the 12mm, 15mm or 20mm tissue basket under local anesthesia, depending on the size of the lesion. Complications were recorded and classified as immediate if occurring during or shortly after the procedure, or late, if occurring in the post-procedure days. RESULTS:The procedure was considered successful in all cases, with mammographic confirmation of appropriate excision of the targeted lesion. Although, in a single case the basket initially failed to deploy. Immediate complications were encountered in 11 patients, with minor hemorrhage being the most common (n=6). 17 patients suffered late complications, in seven of whom delayed wound healing was observed. Overall, 27 patients suffered Grade 1 complications (20.14%), one patient experienced a Grade 2 complication while no patients encountered Grade 3-5 complications. CONCLUSIONS:According to our experience, the BLES device is an efficient and safe breast biopsy method, with low complication rates, which are minor in their majority. It appears to be a very promising alternative to other, minimally invasive, breast biopsy techniques.

journal_name

Eur J Radiol

authors

Al-Harethee W,Theodoropoulos G,Filippakis GM,Papapanagiotou I,Matiatou M,Georgiou G,Kalles V,Koulocheri D,Nonni A,Konstadoulakis MM,Manouras A,Zografos GC

doi

10.1016/j.ejrad.2011.12.023

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

623-6

issue

4

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(11)00891-6

journal_volume

82

pub_type

杂志文章
  • Diagnostic value of MRI in comparison to scintigraphy, PET, MS-CT and PET/CT for the detection of metastases of bone.

    abstract::The initial localization of metastases in the bone in patients with solid tumors has a relatively good prognosis in comparison with visceral metastasization. The early detection of bone marrow metastases allows for a rapid initiation of therapy and a subsequent reduction in the morbidity rate. Modern MRI is superior t...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.01.016

    authors: Ghanem N,Uhl M,Brink I,Schäfer O,Kelly T,Moser E,Langer M

    更新日期:2005-07-01 00:00:00

  • Advances in paediatric CNS ultrasound.

    abstract::Advanced paediatric ultrasound of the central nervous system (CNS) requires 7 MHz sector and linear transducers, equipment which is highly sensitive to flow velocity (Power Doppler) and additional transcranial axial, coronal and sagittal imaging. New diagnostic possibilities include recognition of subarachnoid hemorrh...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(97)00087-9

    authors: Winkler P

    更新日期:1998-01-01 00:00:00

  • Factors affecting the rate of false positive marks in CAD in full-field digital mammography.

    abstract:OBJECTIVE:To assess the effect of breast density, fibroglandular tissue volume, and breast volume on the rate of false-positive marks of a computer-assisted detection software in digital mammography. MATERIALS AND METHODS:222 patients with normal digital mammograms and a minimum follow-up of 22 months were retrospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.02.017

    authors: Engelken F,Bremme R,Bick U,Hammann-Kloss S,Fallenberg EM

    更新日期:2012-08-01 00:00:00

  • CT features of retroperitoneal neurilemmoma.

    abstract:PURPOSE:The aim of this study was to characterize the CT features of retroperitoneal neurilemmoma. METHODS:The CT findings were reviewed in seven patients with retroperitoneal neurilemmoma. RESULTS:All of the tumours were well-demarcated round or oval masses. In five cases, heterogeneous contrast enhancement was note...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00032-6

    authors: Kinoshita T,Naganuma H,Ishii K,Itoh H

    更新日期:1998-03-01 00:00:00

  • Visualization of morphological parenchymal changes in emphysema: comparison of different MRI sequences to 3D-HRCT.

    abstract:PURPOSE:Thin-section CT is the modality of choice for morphological imaging the lung parenchyma, while proton-MRI might be used for functional assessment. However, the capability of MRI to visualize morphological parenchymal alterations in emphysema is undetermined. Thus, the aim of the study was to compare different M...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.029

    authors: Ley-Zaporozhan J,Ley S,Eberhardt R,Kauczor HU,Heussel CP

    更新日期:2010-01-01 00:00:00

  • Accelerated MRI of the knee. Quality and efficiency of compressed sensing.

    abstract:PURPOSE:To evaluate potential clinical acceleration factors of Compressed SENSE (CS)1 in direct comparison with SENSE for fat saturated (fs)2, proton density-weighted (PD)3 2D and 3D sequences of the knee. METHOD:Twenty healthy volunteers were scanned with a 3 T scanner, all receiving a standard, fs 2D PD, three CS (C...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109273

    authors: Iuga AI,Abdullayev N,Weiss K,Haneder S,Brüggemann-Bratke L,Maintz D,Rau R,Bratke G

    更新日期:2020-11-01 00:00:00

  • Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    abstract:AIM:To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measu...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00014-5

    authors: Blomley MJ,McBride A,Mohammedtagi S,Albrecht T,Harvey CJ,Jäger R,Standfield NJ,Dawson P

    更新日期:1999-06-01 00:00:00

  • Pulmonary arteriovenous malformation (PAVM) reperfusion after percutaneous embolization: Sensitivity and specificity of non-enhanced CT.

    abstract:PURPOSE:To evaluate the sensitivity and specificity of non-enhanced chest CT to detect reperfusion after pulmonary arteriovenous malformation (PAVM) embolization. MATERIALS AND METHODS:The Institutional Review Board approved this retrospective HIPAA-compliant study and waived the need for patient consent. All consecut...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.11.014

    authors: Bélanger C,Chartrand-Lefebvre C,Soulez G,Faughnan ME,Tahir MR,Giroux MF,Gilbert P,Perreault P,Bouchard L,Oliva VL,Therasse E

    更新日期:2016-01-01 00:00:00

  • Computed tomography and endosonography in the preoperative staging of rectal carcinoma.

    abstract::In 30 patients with rectal carcinoma the accuracy of computed tomography (CT) and endosonography (ES) was compared with the surgical specimen. Three cases were overstaged by ES and 4 cases were understaged by CT. The accuracy of ES was 84% and of CT only 76%. Both methods had advantages and limitations. An accurate st...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Rotte KH,Klühs L,Kleinau H,Kriedemann E

    更新日期:1989-08-01 00:00:00

  • Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease.

    abstract:PURPOSE:To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:This study was approved by o...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.09.010

    authors: Nambu A,Zach J,Schroeder J,Jin G,Kim SS,Kim YI,Schnell C,Bowler R,Lynch DA

    更新日期:2016-11-01 00:00:00

  • Comparison of automated 4-chamber cardiac views versus axial views for measuring right ventricular enlargement in patients with suspected pulmonary embolism.

    abstract:PURPOSE:Compare the right ventricle to left ventricle (RV/LV) diameter ratio obtained from axial pulmonary CT angiograms (CTPA) with those derived from automatically generated 4-chamber (4-CH) reformats in patients with suspected pulmonary embolism (PE). METHODS:In this institutional review board-approved study we inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.041

    authors: Wittenberg R,van Vliet JW,Ghaye B,Peters JF,Schaefer-Prokop CM,Coche E

    更新日期:2012-02-01 00:00:00

  • Cardiac magnetic resonance characteristics in young survivors of aborted sudden cardiac death.

    abstract:PURPOSE:We aimed to identify and assess cardiac abnormalities by cardiovascular magnetic resonance (CMR) in a non-ischaemic aborted sudden cardiac death (SCD) population and to establish possible predictors of SCD. METHODS:Thirty-six consecutive SCD survivors [median age 37.6 years (IQR 24.1-43.2), 31% female] with no...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.06.004

    authors: Zaremba T,Brøndberg AK,Jensen HK,Kim WY

    更新日期:2018-08-01 00:00:00

  • Resting-state functional connectivity MRI analysis in Human Immunodeficiency Virus and Hepatitis C Virus co-infected subjects. A pilot study.

    abstract:BACKGROUND AND PURPOSE:Hepatitis C virus (HCV) co-infection's role on cognitive impairment of human immunodeficiency virus (HIV) positive patients is still debated and functional neuroimaging evaluation on this matter is lacking. To provide further insight about HCV's neuro-effects on HIV associated neurocognitive diso...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.03.022

    authors: Corgiolu S,Barberini L,Suri JS,Mandas A,Costaggiu D,Piano P,Zaccagna F,Lucatelli P,Balestrieri A,Saba L

    更新日期:2018-05-01 00:00:00

  • Statin-induced focal myositis of the upper extremity. A report of two cases.

    abstract::Statins are widely used to lower increased cholesterol levels with the aim to prevent major cardiovascular events. However, they bare the risk of myotoxic side effects. We report on two patients with focal weakness and pain in the upper extremities. In both patients, abnormal MRI signal heights in the muscle groups in...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.031

    authors: Wagner M,Mühldorfer-Fodor M,Prommersberger KJ,Schmitt R

    更新日期:2011-02-01 00:00:00

  • Posterior ankle impingement in athletes: Pathogenesis, imaging features and differential diagnoses.

    abstract::Posterior ankle impingement is a clinical diagnosis which can be seen following a traumatic hyper-plantar flexion event and may lead to painful symptoms in athletes such as female dancers ('en pointe'), football players, javelin throwers and gymnasts. Symptoms of posterior ankle impingement are due to failure to accom...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2015.07.017

    authors: Hayashi D,Roemer FW,D'Hooghe P,Guermazi A

    更新日期:2015-11-01 00:00:00

  • Whole-body magnetic resonance imaging: Incidental findings in paediatric and adult populations.

    abstract:PURPOSE:To determine the prevalence and characterise the significance of incidental findings on whole-body MRI in paediatric and adult populations. METHODS:A retrospective, single-institution study over a period of 8 years. The study population comprised 325 paediatric (0-18 yrs) patients and 148 adults (19-40 yrs) re...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109156

    authors: Preez HD,Lasker I,Rajakulasingam R,Saifuddin A

    更新日期:2020-09-01 00:00:00

  • Pericardial and thoracic peri-aortic adipose tissues contribute to systemic inflammation and calcified coronary atherosclerosis independent of body fat composition, anthropometric measures and traditional cardiovascular risks.

    abstract:BACKGROUND:Coronary atherosclerosis has traditionally been proposed to be associated with several cardiovascular risk factors and anthropometric measures. However, clinical data regarding the independent value of visceral adipose tissue in addition to such traditional predictors remains obscure. MATERIALS AND METHODS:...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.035

    authors: Yun CH,Lin TY,Wu YJ,Liu CC,Kuo JY,Yeh HI,Yang FS,Chen SC,Hou CJ,Bezerra HG,Hung CL,Cury RC

    更新日期:2012-04-01 00:00:00

  • Could ultrasonic elastography help the diagnosis of breast cancer with the usage of sonographic BI-RADS classification?

    abstract:OBJECTIVES:The purpose was to evaluate whether BI-RADS (the Breast Imaging Recording and Data System) combined with UE (ultrasound elastography) could improve the differentiation and characterization of benign and malignant breast lesions by comparing with BI-RADS. METHODS:A total of 1080 patients with 1194 breast les...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2015.08.015

    authors: Hao SY,Ou B,Li LJ,Peng YL,Wang Y,Liu LS,Xiao Y,Liu SJ,Wu CJ,Jiang YX,Parajuly SS,Xu P,Hao Y,Li J,Zhi H,Luo BM

    更新日期:2015-12-01 00:00:00

  • MR-pathologic correlation of lung specimens.

    abstract::The aim of this study was to assess the feasibility of a new MR-pathologic correlation method utilizing a high-resolution MR technique with a 3-inch surface coil and elimination of susceptibility by replacing air in the pulmonary alveoli of lung specimens with water. Inflated cadaver lung specimens of various lung dis...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00270-x

    authors: Hatabu H,Uematsu H,Hasegawa I,Itoh H

    更新日期:2002-12-01 00:00:00

  • Wall enhancement characteristics of vertebrobasilar nonsaccular aneurysms and their relationship to symptoms.

    abstract:PURPOSE:This study aims to explore wall enhancement characteristics of vertebrobasilar nonsaccular aneurysms (VBNAs) and their relationship to clinical symptoms. METHODS:We retrospectively analyzed VBNAs in the high resolution MR vessel wall imaging (HR-VWI) databases at two institutions. The aneurysmal basic characte...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109064

    authors: Cao L,Zhu C,Eisenmenger L,Du X,Liu J,Yang Q,Lu J,Li K,Saloner D

    更新日期:2020-08-01 00:00:00

  • Rapid estimation of split renal function in kidney donors using software developed for computed tomographic renal volumetry.

    abstract:PURPOSE:To evaluate the speed and precision of split renal volume (SRV) measurement, which is the ratio of unilateral renal volume to bilateral renal volume, using a newly developed software for computed tomographic (CT) volumetry and to investigate the usefulness of SRV for the estimation of split renal function (SRF)...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.11.013

    authors: Kato F,Kamishima T,Morita K,Muto NS,Okamoto S,Omatsu T,Oyama N,Terae S,Kanegae K,Nonomura K,Shirato H

    更新日期:2011-07-01 00:00:00

  • Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    abstract:OBJECTIVES:To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. METHODS:A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.12.019

    authors: Grueneisen J,Sawicki LM,Wetter A,Kirchner J,Kinner S,Aktas B,Forsting M,Ruhlmann V,Umutlu L

    更新日期:2017-04-01 00:00:00

  • Preliminary European intravenous clinical experience with a new, low osmolar, nonionic contrast medium: ioversol (Optiray).

    abstract::The intravenous clinical trial program of ioversol (Optiray), a low osmolar, nonionic, monomeric contrast agent characterized by high hydrophilicity, is evaluated on the basis of results from the first clinical trials conducted in Europe as part of the development of the 300 and 350 mgI/ml formulations: 7 double-blind...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/0720-048x(91)90094-c

    authors: Le Mignon MM,Azau C,Arthaud A,Bonnemain B

    更新日期:1991-09-01 00:00:00

  • Prostate MRI technical parameters standardization: A systematic review on adherence to PI-RADSv2 acquisition protocol.

    abstract:PURPOSE:The Prostate Imaging-Reporting and Data System has been developed to standardize prostate MRI in terms of acquisition, interpretation and reporting. It received a major revision in late 2014 (PI-RADSv2). Recently, doubts have been raised on imaging facilities adherence to its acquisition protocol. With this sys...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析

    doi:10.1016/j.ejrad.2019.108662

    authors: Cuocolo R,Stanzione A,Ponsiglione A,Verde F,Ventimiglia A,Romeo V,Petretta M,Imbriaco M

    更新日期:2019-11-01 00:00:00

  • T1 mapping for detection of left ventricular myocardial fibrosis in hypertrophic cardiomyopathy: a preliminary study.

    abstract:PURPOSE:To investigate the diagnostic value of T1 mapping imaging of evaluating fibrosis in patients with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS:21 subjects with HCM and 18 healthy volunteers underwent conventional late gadolinium enhancement (LGE) imaging and T1 mapping imaging. The region of myocar...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.12.014

    authors: Lu M,Zhao S,Yin G,Jiang S,Zhao T,Chen X,Tian L,Zhang Y,Wei Y,Liu Q,He Z,Xue H,An J,Shah S

    更新日期:2013-05-01 00:00:00

  • High-resolution functional MRI of the human amygdala at 7 T.

    abstract::Functional magnetic resonance imaging (fMRI) has become the primary non-invasive method for investigating the human brain function. With an increasing number of ultra-high field MR systems worldwide possibilities of higher spatial and temporal resolution in combination with increased sensitivity and specificity are ex...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.09.025

    authors: Sladky R,Baldinger P,Kranz GS,Tröstl J,Höflich A,Lanzenberger R,Moser E,Windischberger C

    更新日期:2013-05-01 00:00:00

  • Fibular lipoma with areas of bone infarct calcification.

    abstract::An anatomico-radiological study of a painful intraosseous lipoma of the fibula is reported. A blown up cortex and a rearrangement of surrounding cancellous bone trabeculae were observed. The lipoma contained two small bone infarcts. A radiological differential diagnosis with calcified chondroma as well as the pathogen...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Lagier R

    更新日期:1985-08-01 00:00:00

  • The spectrum of pulmonary sarcoidosis: variations of high-resolution CT findings and clues for specific diagnosis.

    abstract::Sarcoidosis is a systemic disease of unknown cause, characterized by widespread non-caseating granulomas. There is a wide spectrum of radiologic manifestations in pulmonary sarcoidosis, providing challenges to radiologists. However, recognition of the key features of sarcoidosis with knowledge of its pathologic backgr...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2008.09.038

    authors: Nishino M,Lee KS,Itoh H,Hatabu H

    更新日期:2010-01-01 00:00:00

  • Contrast-enhanced ultrasound study of primary hepatic angiosarcoma: a pitfall of non-enhancement.

    abstract:OBJECTIVE:To investigate the contrast-enhanced ultrasound (CEUS) characteristics of primary hepatic angiosarcoma (PHA). METHODS:The sonographic findings and CEUS images of PHA in three patients were retrospectively analyzed. RESULTS:In our study, 3 cases of PHA (2 multiple nodules and 1 solitary mass) showed similar ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.026

    authors: Wang L,Lv K,Chang XY,Xia Y,Yang ZY,Jiang YX,Dai Q,Tan L,Li JC

    更新日期:2012-09-01 00:00:00

  • Can the IVIM model be used for renal perfusion imaging?

    abstract:OBJECTIVE:Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incohe...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)01161-3

    authors: Müller MF,Prasad PV,Edelman RR

    更新日期:1998-02-01 00:00:00