Physical and biological impacts of collimator-scattered protons in spot-scanning proton therapy.

Abstract:

:To improve the penumbra of low-energy beams used in spot-scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused on patient-specific brass collimators, the collimator-scattered protons' physical and biological effects were investigated. The Geant4 Monte Carlo code was used to model the collimators mounted on the scanning nozzle of the Hokkaido University Hospital. A systematic survey was performed in water phantom with various-sized rectangular targets; range (5-20 cm), spread-out Bragg peak (SOBP) (5-10 cm), and field size (2 × 2-16 × 16 cm2 ). It revealed that both the range and SOBP dependences of the physical dose increase had similar trends to passive scattering methods, that is, it increased largely with the range and slightly with the SOBP. The physical impact was maximized at the surface (3%-22% for the tested geometries) and decreased with depth. In contrast, the field size (FS) dependence differed from that observed in passive scattering: the increase was high for both small and large FSs. This may be attributed to the different phase-space shapes at the target boundary between the two dose delivery methods. Next, the biological impact was estimated based on the increase in dose-averaged linear energy transfer (LETd ) and relative biological effectiveness (RBE). The LETd of the collimator-scattered protons were several keV/μm higher than that of unscattered ones; however, since this large increase was observed only at the positions receiving a small scattered dose, the overall LETd increase was negligible. As a consequence, the RBE increase did not exceed 0.05. Finally, the effects on patient geometries were estimated by testing two patient plans, and a negligible RBE increase (0.9% at most in the critical organs at surface) was observed in both cases. Therefore, the impact of collimator-scattered protons is almost entirely attributed to the physical dose increase, while the RBE increase is negligible.

journal_name

J Appl Clin Med Phys

authors

Ueno K,Matsuura T,Hirayama S,Takao S,Ueda H,Matsuo Y,Yoshimura T,Umegaki K

doi

10.1002/acm2.12653

subject

Has Abstract

pub_date

2019-07-01 00:00:00

pages

48-57

issue

7

issn

1526-9914

journal_volume

20

pub_type

杂志文章
  • Gantry angle dependent beam control optimization of a traveling wave linear accelerator to improve VMAT delivery.

    abstract:INTRODUCTION:Increased modulation and dynamical delivery of external beam radiotherapy (EBRT), such as volumetric modulated arc therapy (VMAT) with dynamic gantry rotation, continuously variable dose rate (CVDR) and field shapes that change during the beam, place greater demands on the performance of linear accelerator...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13047

    authors: van Appeldoorn AA,Kok JGM,Wolthaus JWH

    更新日期:2020-10-23 00:00:00

  • Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

    abstract::For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dos...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i6.5514

    authors: Liu H,Zhuang T,Stephans K,Videtic G,Raithel S,Djemil T,Xia P

    更新日期:2015-11-08 00:00:00

  • Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy.

    abstract:PURPOSE:The objective of this study was to evaluate the impact of the magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and range in pencil beam scanning proton therapy. METHODS:"Field regulation" - a feature to reduce the switching time between layers by applying ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13045

    authors: Rana S,Bennouna J,Gutierrez AN,Rosenfeld AB

    更新日期:2020-10-15 00:00:00

  • Quantitative analysis of image quality for acceptance and commissioning of an MRI simulator with a semiautomatic method.

    abstract::Magnetic Resonance Imaging (MRI) simulation differs from diagnostic MRI in purpose, technical requirements, and implementation. We propose a semiautomatic method for image acceptance and commissioning for the scanner, the radiofrequency (RF) coils, and pulse sequences for an MRI simulator. The ACR MRI accreditation la...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12311

    authors: Chen X,Dai J

    更新日期:2018-05-01 00:00:00

  • Experience in implementing continuous arterial spin labeling on a commercial MR scanner.

    abstract::Continuous arterial spin labeling (CASL) is a technique for performing quantitative perfusion measurements without the need for exogenous contrast agent administration. This technique has seen limited use in the clinic due to problems of poor sensitivity and the potential for artifacts. In addition, CASL requires the ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v6i1.2068

    authors: Steger TR,Jackson EF

    更新日期:2005-01-01 00:00:00

  • Generation of wedge-shaped dose distributions through dynamic multileaf collimator dose delivery.

    abstract::A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i3.2060

    authors: Zhu J

    更新日期:2005-07-01 00:00:00

  • TOPAS Simulation of the Mevion S250 compact proton therapy unit.

    abstract::As proton therapy becomes increasingly popular, so does the need for Monte Carlo simulation studies involving accurate beam line modeling of proton treatment units. In this study, the 24 beam configurations of the Mevion S250 proton therapy system installed recently at our institution were modeled using the TOolkit fo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12077

    authors: Prusator M,Ahmad S,Chen Y

    更新日期:2017-05-01 00:00:00

  • Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy.

    abstract::MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5057

    authors: Dhanesar SK,Lim TY,Du W,Bruno TL,Frank SJ,Kudchadker RJ

    更新日期:2015-09-08 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00

  • Radiation therapy plan checks in a paperless clinic.

    abstract::Traditional quality assurance checks of a patient's radiation therapy plan involve printing out treatment parameters from the treatment planning system and the "record and verify" (R&V) system and visually checking the information for one-to-one correspondence. In a paperless environment, one can automate this process...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v10i1.2905

    authors: Siochi RA,Pennington EC,Waldron TJ,Bayouth JE

    更新日期:2009-01-27 00:00:00

  • Dosimetric characteristics of a cubic-block-piled compensator for intensity-modulated radiation therapy in the Pinnacle radiotherapy treatment planning system.

    abstract::We examined the dose distributions generated by Pinnacle3 (Philips Radiation Oncology Systems, Milpitas, CA) for intensity-modulated radiotherapy (IMRT) plans using a cubic-block-piled compensator as the intensity modulator for 4-MV and 10-MV photon beams. The Pinnacle treatment planning system (TPS) uses an algorithm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i1.2323

    authors: Sasaki K,Obata Y

    更新日期:2006-06-16 00:00:00

  • A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners.

    abstract::The GafChromic XR Type R film is a relatively new product for recording high radiation dose in interventional radiological procedures. Means of measuring the film response were studied in this investigation. Two handheld reflective-type densitometers of different models were compared in the range of 0-8 Gy. They were ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i4.2501

    authors: Thomas G,Chu RY,Rabe F

    更新日期:2003-10-01 00:00:00

  • Assessment of an organ-based tube current modulation in thoracic computed tomography.

    abstract::Recently, specific computed tomography (CT) scanners have been equipped with organ-based tube current modulation (TCM) technology. It is possible that organ-based TCM will replace the conventional dose-reduction technique of reducing the effective milliampere-second. The aim of this study was to determine if organ-bas...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i2.3731

    authors: Matsubara K,Sugai M,Toyoda A,Koshida H,Sakuta K,Takata T,Koshida K,Iida H,Matsui O

    更新日期:2012-03-08 00:00:00

  • Frameless stereotactic body radiation therapy for multiple lung metastases.

    abstract::Two patients with multiple lung metastases (≥ 5) were treated using frameless stereotactic body radiation therapy (SBRT) on an Elekta Axesse linear accelerator equipped with an interdigitation-capable multileaf collimator and four-dimensional cone-beam CT (4D CBCT). The technique and the early clinical outcomes were e...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i4.4737

    authors: Li Q,Mu J,Gu W,Chen Y,Ning Z,Jin J,Pei H

    更新日期:2014-07-08 00:00:00

  • Electron energy constancy verification using a double-wedge phantom.

    abstract::Routine constancy checks of electron energy are often time consuming because of the necessity to measure a dose at two depths. A technique is described that uses a double-wedge shaped phantom positioned on a Profiler diode array for measuring an electron energy constancy metric similar to R(50). The double-wedge elect...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i3.2516

    authors: Wells DM,Picco PJ,Ansbacher W

    更新日期:2003-07-01 00:00:00

  • Evaluation of three APBI techniques under NSABP B-39 guidelines.

    abstract::This work compares two accelerated partial breast irradiation modalities, MammoSite brachytherapy and three dimensional conformal radiotherapy (3D-CRT), to a new method, SAVI brachytherapy, following NSABP B-39 guidelines. A total of 21 patients treated at UC San Diego with the SAVI device were evaluated in this compa...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i1.3021

    authors: Scanderbeg D,Yashar C,White G,Rice R,Pawlicki T

    更新日期:2009-12-03 00:00:00

  • Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system.

    abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v5i2.1947

    authors: Wang L,Jacob R,Chen L,Ma C,Movsas B,Feigenberg S,Konski A

    更新日期:2004-04-01 00:00:00

  • Comparative analysis for renal stereotactic body radiotherapy using Cyberknife, VMAT and proton therapy based treatment planning.

    abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12308

    authors: Baydoun A,Vapiwala N,Ponsky LE,Awan M,Kassaee A,Sutton D,Podder TK,Zhang Y,Dobbins D,Muzic RF Jr,Traughber B,Machtay M,Ellis R

    更新日期:2018-03-14 00:00:00

  • On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

    abstract::In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobb...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i1.5792

    authors: Du W,Johnson JL,Jiang W,Kudchadker RJ

    更新日期:2016-01-08 00:00:00

  • Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning.

    abstract::The monochromatic images acquired by Gemstone spectral imaging (GSI) mode on the GE CT750 HD theoretically determines the computed tomography (CT) number more accurately than that of conventional scanner. Using the former, the CT number is calculated from (synthesized) monoenergetic X-ray data. We reasoned that the mo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4335

    authors: Yagi M,Ueguchi T,Koizumi M,Ogata T,Yamada S,Takahashi Y,Sumida I,Akino Y,Konishi K,Isohashi F,Tomiyama N,Yoshioka Y,Ogawa K

    更新日期:2013-09-06 00:00:00

  • Voxel-based supervised machine learning of peripheral zone prostate cancer using noncontrast multiparametric MRI.

    abstract:PURPOSE:The aim of this study was to develop and assess the performance of supervised machine learning technique to classify magnetic resonance imaging (MRI) voxels as cancerous or noncancerous using noncontrast multiparametric MRI (mp-MRI), comprised of T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12992

    authors: Gholizadeh N,Simpson J,Ramadan S,Denham J,Lau P,Siddique S,Dowling J,Welsh J,Chalup S,Greer PB

    更新日期:2020-10-01 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Brachytherapy treatment planning commissioning: effect of the election of proper bibliography and finite size of TG-43 input data on standard treatments.

    abstract::The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.4730

    authors: Valdés CN,Píriz GH,Lozano E

    更新日期:2015-07-08 00:00:00

  • A fast, independent dose check of HDR plans.

    abstract::High dose rate (HDR) brachytherapy often involves optimization routines to calculate the dwell times and positions of a radioactive source along specified applicator paths. These routines optimize the dwells in such a way as to deliver the prescribed dose at one or more points while satisfying various constraints. The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i2.2530

    authors: Lachaine ME,Gorman JC,Palisca MG

    更新日期:2003-04-01 00:00:00

  • Dosimetric comparison of three intensity-modulated radiation therapies for left breast cancer after breast-conserving surgery.

    abstract:PURPOSE:This study aimed to evaluate dosimetric differences of intensity-modulated radiation therapy (IMRT) in target and normal tissues after breast-conserving surgery. METHODS:IMRT five-field plan I, IMRT six-field plan II, and field-in-field-direct machine parameter optimization-IMRT plan III were designed for each...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12287

    authors: Zhang HW,Hu B,Xie C,Wang YL

    更新日期:2018-05-01 00:00:00

  • Using an onboard kilovoltage imager to measure setup deviation in intensity-modulated radiation therapy for head-and-neck patients.

    abstract::The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i4.2439

    authors: Mechalakos JG,Hunt MA,Lee NY,Hong LX,Ling CC,Amols HI

    更新日期:2007-09-24 00:00:00

  • A line-profile based double partial fusion method for acquiring planning CT of oversized patients in radiation treatment.

    abstract::True 3D CT dataset for treatment planning of an oversized patient is difficult to acquire due to the bore size and field of view (FOV) reconstruction. This project aims to provide a simple approach to reconstruct true CT data for oversize patients using CT scanner with limited FOV by acquiring double partial CT (left ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i2.3629

    authors: Wu H,Zhao Q,Cao M,Das I

    更新日期:2012-03-08 00:00:00

  • Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique.

    abstract::This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on fiv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4053

    authors: Chow JC,Jiang R

    更新日期:2013-05-06 00:00:00

  • Dose perturbation in the radiotherapy of breast cancer patients implanted with the Magna-Site: a Monte Carlo study.

    abstract::External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which i...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3295

    authors: Chatzigiannis C,Lymperopoulou G,Sandilos P,Dardoufas C,Yakoumakis E,Georgiou E,Karaiskos P

    更新日期:2011-01-19 00:00:00

  • Utilization of a 3D printer to fabricate boluses used for electron therapy of skin lesions of the eye canthi.

    abstract::This work describes the use of 3D printing technology to create individualized boluses for patients treated with electron beam therapy for skin lesions of the eye canthi. It aimed to demonstrate the effectiveness of 3D-printed over manually fabricated paraffin boluses. The study involved 11 patients for whom the const...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12013

    authors: Łukowiak M,Jezierska K,Boehlke M,Więcko M,Łukowiak A,Podraza W,Lewocki M,Masojć B,Falco M

    更新日期:2017-01-01 00:00:00