Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.

Abstract:

:For patients with medically inoperable early-stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy, early treatment plans were based on a simpler dose calculation algorithm, the pencil beam (PB) calculation. Because these patients had the longest treatment follow-up, identifying dose differences between the PB calculated dose and Monte Carlo calculated dose is clinically important for understanding of treatment outcomes. Previous studies found significant dose differences between the PB dose calculation and more accurate dose calculation algorithms, such as convolution-based or Monte Carlo (MC), mostly for three-dimensional conformal radiotherapy (3D CRT) plans. The aim of this study is to investigate whether these observed dose differences also exist for intensity-modulated radiotherapy (IMRT) plans for both centrally and peripherally located tumors. Seventy patients (35 central and 35 peripheral) were retrospectively selected for this study. The clinical IMRT plans that were initially calculated with the PB algorithm were recalculated with the MC algorithm. Among these paired plans, dosimetric parameters were compared for the targets and critical organs. When compared to MC calculation, PB calculation overestimated doses to the planning target volumes (PTVs) of central and peripheral tumors with different magnitudes. The doses to 95% of the central and peripheral PTVs were overestimated by 9.7% ± 5.6% and 12.0% ± 7.3%, respectively. This dose overestimation did not affect doses to the critical organs, such as the spinal cord and lung. In conclusion, for NSCLC treated with IMRT, dose differences between the PB and MC calculations were different from that of 3D CRT. No significant dose differences in critical organs were observed between the two calculations.

journal_name

J Appl Clin Med Phys

authors

Liu H,Zhuang T,Stephans K,Videtic G,Raithel S,Djemil T,Xia P

doi

10.1120/jacmp.v16i6.5514

subject

Has Abstract

pub_date

2015-11-08 00:00:00

pages

91–99

issue

6

issn

1526-9914

journal_volume

16

pub_type

杂志文章
  • A review of patient questions from physicist-patient consults.

    abstract:PURPOSE:To provide insight into the types of questions asked to medical physicists by patients during one-on-one physicist-patient consults at one institution. MATERIALS AND METHODS:Medical physicists trained in patient communication techniques met with patients to provide an overview of the treatment planning and del...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12942

    authors: Atwood TF,Brown DW,Juang T,Moore KL,McConnell KA,Steers JM,Murphy JD,Mundt AJ,Pawlicki T

    更新日期:2020-08-01 00:00:00

  • Optimal slice thickness for object detection with longitudinal partial volume effects in computed tomography.

    abstract::Longitudinal partial volume effects (z-axial PVE), which occur when an object partly occupies a slice, degrade image resolution and contrast in computed tomography (CT). Z-axial PVE is unavoidable for subslice objects and reduces their contrast according to their fraction contained within the slice. This effect can be...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12005

    authors: Monnin P,Sfameni N,Gianoli A,Ding S

    更新日期:2017-01-01 00:00:00

  • The investigation on the location effect of external markers in respiratory-gated radiotherapy.

    abstract:PURPOSE:To investigate the effect of the marker placement on the correlation relationship between the motions of external markers and the internal target under different breathing patterns for several lung cancer patients. METHOD AND MATERIAL:To monitor and record simultaneous motions of internal target and associated...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v9i2.2758

    authors: Yan H,Zhu G,Yang J,Lu M,Ajlouni M,Kim JH,Yin FF

    更新日期:2008-04-16 00:00:00

  • A protocol to extend the longitudinal coverage of on-board cone-beam CT.

    abstract::The longitudinal coverage of a LINAC-mounted CBCT scan is limited to the corresponding dimensional limits of its flat panel detector, which is often shorter than the length of the treatment field. These limits become apparent when fields are designed to encompass wide regions, as when providing nodal coverage. Therefo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i4.3796

    authors: Zheng D,Lu J,Jefferson A,Zhang C,Wu J,Sleeman W,Weiss E,Dogan N,Song S,Williamson J

    更新日期:2012-07-05 00:00:00

  • Measurement of gantry rotation time in modern ct.

    abstract::The purpose of this study was to develop and evaluate a noninvasive method to assess rotation time in modern commercial computed tomography (CT) systems. The rotation time was measured at a selected nominal rotation time (400 ms) utilizing two types of solid-state detectors: the RTI's CT Dose Profiler (CTDP) and Unfor...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4517

    authors: Fukuda A,Lin PJ,Matsubara K,Miyati T

    更新日期:2014-01-06 00:00:00

  • A quality assurance procedure to evaluate cone-beam CT image center congruence with the radiation isocenter of a linear accelerator.

    abstract::A quality assurance (QA) procedure was developed to evaluate the congruence between the cone-beam computed tomography (CBCT) image center and the radiation isocenter on a Varian Trilogy linac. In contrast to the published QA procedures, this method did not require a ball bearing (BB) phantom to be placed exactly at th...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i4.3297

    authors: Du W,Yang JN,Chang EL,Luo D,McAleer MF,Shiu A,Martel MK

    更新日期:2010-07-02 00:00:00

  • Assessment of error in the MV radiation isocenter position calculated with the Elekta XVI software.

    abstract::The assessment of the coincidence of imaging and radiation isocenters is an important task of regular quality assurance of medical linear accelerators (linacs) as recommended in national and international quality assurance guidelines. A previously reported investigation of the accuracy of the Elekta XVI software to lo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12861

    authors: Chojnowski JM,Warr GB,Sykes JR,Thwaites DI

    更新日期:2020-05-01 00:00:00

  • The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media.

    abstract::A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one with...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4382

    authors: Kan MW,Leung LH,Yu PK

    更新日期:2013-11-04 00:00:00

  • Clinical validation of ring-mounted halcyon linac for lung SBRT: comparison to SBRT-dedicated C-arm linac treatments.

    abstract::Stereotactic body radiotherapy (SBRT) of lung tumors via the ring-mounted Halcyon Linac, a fast kilovoltage cone beam CT-guided treatment with coplanar geometry, a single energy 6MV flattening filter free (FFF) beam and volumetric modulated arc therapy (VMAT) is a fast, safe, and feasible treatment modality for select...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13146

    authors: Pokhrel D,Visak J,Critchfield LC,Stephen J,Bernard ME,Randall M,Kudrimoti M

    更新日期:2020-12-20 00:00:00

  • Intrafractional relationship changes between an external breathing signal and fiducial marker positions in pancreatic cancer patients.

    abstract:BACKGROUND AND PURPOSE:The purpose of this study of pancreatic cancer patients treated with respiratory-guided stereotactic body radiotherapy (SBRT) on a standard linac was to investigate (a) the intrafractional relationship change (IRC) between a breathing signal and the tumor position, (b) the impact of IRC on the de...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12841

    authors: Pettersson N,Oderinde OM,Murphy J,Simpson D,Cerviño LI

    更新日期:2020-03-01 00:00:00

  • Physical and biological impacts of collimator-scattered protons in spot-scanning proton therapy.

    abstract::To improve the penumbra of low-energy beams used in spot-scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused on patient-specific brass collimators, the collimator-scattered protons' physical and biological effects were investigated. The Geant4 Monte Carlo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12653

    authors: Ueno K,Matsuura T,Hirayama S,Takao S,Ueda H,Matsuo Y,Yoshimura T,Umegaki K

    更新日期:2019-07-01 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • Role of adaptive radiation therapy for pediatric patients with diffuse pontine glioma.

    abstract::We investigate the role of adaptive radiation therapy in pediatric patients with diffuse pontine glioma and the impact of steroid-related weight gain on treatment parameters utilizing cone-beam CT. Fifteen patients with diffuse pontine glioma were treated with three-dimensional conformal radiation therapy and enrolled...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:

    authors: Beltran C,Sharma S,Merchant TE

    更新日期:2011-01-30 00:00:00

  • Technical Note: Comparison of the internal target volume (ITV) contours and dose calculations on 4DCT, average CBCT, and 4DCBCT imaging for lung stereotactic body radiation therapy (SBRT).

    abstract:PURPOSE:To investigate the differences between internal target volumes (ITVs) contoured on the simulation 4DCT and daily 4DCBCT images for lung cancer patients treated with stereotactic body radiotherapy (SBRT) and determine the dose delivered on 4D planning technique. METHODS:For nine patients, 4DCBCTs were acquired ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13041

    authors: Dumas M,Laugeman E,Sevak P,Snyder KC,Mao W,Chetty IJ,Ajlouni M,Wen N

    更新日期:2020-10-12 00:00:00

  • Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.

    abstract::The goal of this study was to investigate small field output factors (OFs) for flat-tening filter-free (FFF) beams on a dedicated stereotactic linear accelerator-based system. From this data, the collimator exchange effect was quantified, and detector-specific correction factors were generated. Output factors for 16 j...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6433

    authors: Qin Y,Zhong H,Wen N,Snyder K,Huang Y,Chetty IJ

    更新日期:2016-11-08 00:00:00

  • Effectiveness of a novel gas-release endorectal balloon in the removal of rectal gas for prostate proton radiation therapy.

    abstract::Endorectal balloons (ERBs) are routinely used in prostate proton radiation therapy to immobilize the prostate and spare the rectal wall. Rectal gas can distend the rectum and displace the prostate even in the presence of ERBs. The purpose of this work was to quantify the effects an ERB with a passive gas release condu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i5.3945

    authors: Wootton LS,Kudchadker RJ,Beddar AS,Lee AK

    更新日期:2012-09-06 00:00:00

  • Can Hyperpolarized Helium MRI add to radiation planning and follow-up in lung cancer?

    abstract::Locally advanced non-small-cell lung cancer (NSCLC) is a common disease with a low overall survival even with aggressive treatments. Standard imaging (CT and PET/CT) provide no information about normal lung function. We therefore, sought to pilot HeMRI in patients with non-small-cell lung cancer before and after defin...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i2.3357

    authors: Allen AM,Albert M,Caglar HB,Zygmanski P,Soto R,Killoran J,Sun Y

    更新日期:2011-01-31 00:00:00

  • Effect of RTOG breast/chest wall guidelines on dose-volume histogram parameters.

    abstract::Treatment planning for breast cancer has been traditionally based on clinical landmarks. The Radiation Therapy Oncology Group (RTOG) published consensus guidelines on contouring target volumes (TV) for the breast/chest wall and draining lymphatics. The effect of these guidelines on dosimetric parameters in surrounding...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i2.4547

    authors: Rudra S,Al-Hallaq HA,Feng C,Chmura SJ,Hasan Y

    更新日期:2014-03-06 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Using C-Arm X-ray images from marker insertion to confirm the gold fiducial marker identification in an MRI-only prostate radiotherapy workflow.

    abstract::Prostate cancer radiotherapy workflows, solely based on magnetic resonance imaging (MRI), are now in clinical use. In these workflows, intraprostatic gold fiducial markers (GFM) show similar signal behavior as calcifications and bleeding in T2-weighted MRI-images. Accurate GFM identification in MRI-only radiotherapy w...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12478

    authors: Gustafsson C,Persson E,Gunnlaugsson A,Olsson LE

    更新日期:2018-11-01 00:00:00

  • Experience in implementing continuous arterial spin labeling on a commercial MR scanner.

    abstract::Continuous arterial spin labeling (CASL) is a technique for performing quantitative perfusion measurements without the need for exogenous contrast agent administration. This technique has seen limited use in the clinic due to problems of poor sensitivity and the potential for artifacts. In addition, CASL requires the ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.v6i1.2068

    authors: Steger TR,Jackson EF

    更新日期:2005-01-01 00:00:00

  • 100 days with scans of the same Catphan phantom on the same CT scanner.

    abstract::Quality control (QC) of CT scanners is important to evaluate image quality and radiation dose. Different QC phantoms for testing image quality parameters on CT are commercially available, and Catphan phantoms are widely used for this purpose. More data from measured image quality parameters on CT are necessary to asse...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12186

    authors: Husby E,Svendsen ED,Andersen HK,Martinsen ACT

    更新日期:2017-11-01 00:00:00

  • Evaluation of the MIM Symphony treatment planning system for low-dose-rate- prostate brachytherapy.

    abstract::MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i5.5057

    authors: Dhanesar SK,Lim TY,Du W,Bruno TL,Frank SJ,Kudchadker RJ

    更新日期:2015-09-08 00:00:00

  • Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.

    abstract::An inverse treatment planning (ITP) module on a commercial treatment planning system (TPS) (Helax AB, Uppsala, Sweden) is being used for an in-house clinical trial for treatment of nasopharyngeal cancer with contralateral parotid sparing. Intensity modulated radiation therapy (IMRT) fields are delivered by step and sh...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i2.2580

    authors: MacKenzie MA,Lachaine M,Murray B,Fallone BG,Robinson D,Field GC

    更新日期:2002-04-01 00:00:00

  • Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors.

    abstract::The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i5.4931

    authors: Sio TT,Jensen AR,Miller RC,Fong de los Santos LE,Hallemeier CL,Foster NR,Park SS,Bauer HJ,Chang K,Garces YI,Olivier KR

    更新日期:2014-09-08 00:00:00

  • Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.

    abstract:PURPOSE:To evaluate the quality of patient-specific complicated treatment plans, including commercialized treatment planning systems (TPS) and commissioned beam data, we developed a process of quality assurance (QA) using a Monte Carlo (MC) platform. Specifically, we constructed an interface system that automatically c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12718

    authors: Lee B,Jeong S,Chung K,Yoon M,Park HC,Han Y,Jung SH

    更新日期:2019-10-01 00:00:00

  • Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar IMRT, coplanar IMRT, and VMAT.

    abstract::The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i1.5126

    authors: Yoo S,Blitzblau R,Yin FF,Horton JK

    更新日期:2015-01-08 00:00:00

  • The accuracy of dynamic wedge dose computation in the ADAC Pinnacle RTP system.

    abstract::The nonphysical wedge is a modality that uses computer-controlled jaw motion to generate wedge-shaped dose distributions. There are Varian enhanced dynamic wedges (EDWs) and Siemens virtual wedges (VWs). We recently commissioned dynamic wedges on both Varian and Siemens LINACs. The beam data, acquired with a Wellhofer...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v5i4.1964

    authors: Shao H,Wu X,Luo C,Crooks A,Bernstein A,Markoe A

    更新日期:2004-10-01 00:00:00

  • AAPM Task Group 103 report on peer review in clinical radiation oncology physics.

    abstract::This report provides guidelines for a peer review process between two clinical radiation oncology physicists. While the Task Group's work was primarily focused on ensuring timely and productive independent reviews for physicists in solo practice, these guidelines may also be appropriate for physicists in a group setti...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章,实务指引

    doi:10.1120/jacmp.v6i4.2142

    authors: Halvorsen PH,Das IJ,Fraser M,Freedman DJ,Rice RE 3rd,Ibbott GS,Parsai EI,Robin TT Jr,Thomadsen BR,American Association of Physicists in Medicine.

    更新日期:2005-10-01 00:00:00

  • Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.

    abstract::During volume-modulated arc therapies (VMAT), dosimetric errors are introduced by multiple open dynamic leaf gaps that are present in fixed diaphragm linear accelerators. The purpose of this work was to develop a methodology for adjusting the rounded leaf end modeling parameters to improve out-of-field dose agreement ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i6.6343

    authors: Young LA,Yang F,Cao N,Meyer J