A line-profile based double partial fusion method for acquiring planning CT of oversized patients in radiation treatment.

Abstract:

:True 3D CT dataset for treatment planning of an oversized patient is difficult to acquire due to the bore size and field of view (FOV) reconstruction. This project aims to provide a simple approach to reconstruct true CT data for oversize patients using CT scanner with limited FOV by acquiring double partial CT (left and right side) images. An efficient line profile-based method has been developed to minimize the difference of the CT numbers in the overlapping region between the right and left images and to generate a complete true 3D CT dataset in the natural state. New image processing modules have been developed and integrated to the Insight Segmentation & Registration Toolkit (ITK 3.6) package. For example, different modules for image cropping, line profile generation, line profile matching, and optimized partial image fusion have been developed. The algorithm has been implemented for images containing the bony structure of the spine and tested on 3D CT planning datasets from both phantom and real patients with satisfactory results in both cases. The proposed optimized line profile-based partial registration method provides a simple and accurate method for acquiring a complete true 3D CT dataset for an oversized patient using CT scanning with small bore size, that can be used for accurate treatment planning.

journal_name

J Appl Clin Med Phys

authors

Wu H,Zhao Q,Cao M,Das I

doi

10.1120/jacmp.v13i2.3629

subject

Has Abstract

pub_date

2012-03-08 00:00:00

pages

3629

issue

2

issn

1526-9914

journal_volume

13

pub_type

杂志文章
  • Comparative analysis for renal stereotactic body radiotherapy using Cyberknife, VMAT and proton therapy based treatment planning.

    abstract:PURPOSE:We conducted this dosimetric analysis to evaluate the feasibility of a multi-center stereotactic body radiation therapy (SBRT) trial for renal cell carcinoma (RCC) using different SBRT platforms. MATERIALS/METHODS:The computed tomography (CT) simulation images of 10 patients with unilateral RCC previously trea...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12308

    authors: Baydoun A,Vapiwala N,Ponsky LE,Awan M,Kassaee A,Sutton D,Podder TK,Zhang Y,Dobbins D,Muzic RF Jr,Traughber B,Machtay M,Ellis R

    更新日期:2018-03-14 00:00:00

  • A quality assurance tool for helical tomotherapy using a step-wedge phantom and the on-board MVCT detector.

    abstract::The purpose of this study was to develop and evaluate filmless quality assurance (QA) tools for helical tomotherapy by using the signals from the on-board megavoltage computed tomography (MVCT) detector and applying a dedicated step-wedge phantom. The step-wedge phantom is a 15 cm long step-like aluminum block positio...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i1.3585

    authors: Althof V,van Haaren P,Westendorp R,Nuver T,Kramer D,Ikink M,Bel A,Minken A

    更新日期:2012-01-05 00:00:00

  • Effect of skull shape approximations in Gamma Knife dose calculations.

    abstract::Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i3.2377

    authors: Berndt A,Beck J

    更新日期:2007-07-17 00:00:00

  • Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system.

    abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12618

    authors: Lu KM,Yeh DM,Cao BH,Lin CY,Liang CY,Zhou YB,Tsai CJ

    更新日期:2019-06-01 00:00:00

  • Development and performance evaluation of a high-speed multileaf collimator.

    abstract::Multileaf collimator (MLC) tracking represents a promising technique for motion management in radiotherapy. However, the conflict between limited leaf speed/acceleration and the demand for tracking fast target motion is now a prominent issue. Conventional MLCs typically have a maximum leaf speed of 3-4 cm/s and a maxi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12026

    authors: Zhang X,Ye P,Zhang H

    更新日期:2017-01-01 00:00:00

  • Reproducibility in patient-specific IMRT QA.

    abstract::The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D di...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4741

    authors: McKenzie EM,Balter PA,Stingo FC,Jones J,Followill DS,Kry SF

    更新日期:2014-05-08 00:00:00

  • Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.

    abstract::Stereotactic body radiation therapy (SBRT) has been increasingly used as an efficacious treatment modality for early-stage non-small cell lung cancer. The accuracy of dose calculations is compromised due to the presence of inhomogeneity. For the purpose of a consistent prescription, radiation doses were calculated wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4011

    authors: Zhuang T,Djemil T,Qi P,Magnelli A,Stephans K,Videtic G,Xia P

    更新日期:2013-03-04 00:00:00

  • Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique.

    abstract::This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on fiv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i3.4053

    authors: Chow JC,Jiang R

    更新日期:2013-05-06 00:00:00

  • Bleeding detection in wireless capsule endoscopy videos - Color versus texture features.

    abstract::Wireless capsule endoscopy (WCE) is an effective technology that can be used to make a gastrointestinal (GI) tract diagnosis of various lesions and abnormalities. Due to a long time required to pass through the GI tract, the resulting WCE data stream contains a large number of frames which leads to a tedious job for c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12662

    authors: Pogorelov K,Suman S,Azmadi Hussin F,Saeed Malik A,Ostroukhova O,Riegler M,Halvorsen P,Hooi Ho S,Goh KL

    更新日期:2019-08-01 00:00:00

  • The performance of the progressive resolution optimizer (PRO) for RapidArc planning in targets with low-density media.

    abstract::A new version of progressive resolution optimizer (PRO) with an option of air cavity correction has been implemented for RapidArc volumetric-modulated arc therapy (RA). The purpose of this study was to compare the performance of this new PRO with the use of air cavity correction option (PRO10_air) against the one with...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4382

    authors: Kan MW,Leung LH,Yu PK

    更新日期:2013-11-04 00:00:00

  • Peer support: A needs assessment for social support from trained peers in response to stress among medical physicists.

    abstract:PURPOSE:Previous studies suggest that within radiation oncology, medical physicists (MP) experience high workloads. Little is known about how MPs use social support (SS) in times of stress. METHODS:In collaboration with the Workgroup on Prevention of Medical Error, the American Association of Physicists in Medicine ad...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12675

    authors: Johnson J,Ford E,Yu J,Buckey C,Fogh S,Evans SB

    更新日期:2019-09-01 00:00:00

  • Future trends in the supply and demand for radiation oncology physicists.

    abstract::Significant controversy surrounds the 2012 / 2014 decision announced by the Trustees of the American Board of Radiology (ABR) in October of 2007. According to the ABR, only medical physicists who are graduates of a Commission on Accreditation of Medical Physics Education Programs, Inc. (CAMPEP) accredited academic or ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i2.3005

    authors: Mills MD,Thornewill J,Esterhay RJ

    更新日期:2010-04-12 00:00:00

  • Dose deviations induced by respiratory motion for radiotherapy of lung tumors: Impact of CT reconstruction, plan complexity, and fraction size.

    abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12847

    authors: Sande EPS,Acosta Roa AM,Hellebust TP

    更新日期:2020-04-01 00:00:00

  • Automatic calculation of patient size metrics in computed tomography: What level of computational accuracy do we need?

    abstract:OBJECTIVES:To compare the effectiveness of two different patient size metrics based on water equivalent diameter (Dw ), the mid-scan water equivalent diameter Dw_c , and the mean (average) water equivalent diameter in the imaged region, Dw_ave , for automatic detection of accidental changes in computed tomography (CT) ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12240

    authors: Sarmento S,Mendes B,Gouvêa M

    更新日期:2018-01-01 00:00:00

  • Assessment and management of radiotherapy beam intersections with the treatment couch.

    abstract::The impact of the treatment couch on a radiotherapy plan is rarely fully assessed during the treatment planning process. Incorporating a couch model into the treatment planning system (TPS) enables the planner to avoid or dosimetrically evaluate beam-couch intersections. In this work, we demonstrate how existing TPS t...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i2.3171

    authors: Van Prooijen M,Kanesalingam T,Islam MK,Heaton RK

    更新日期:2010-04-19 00:00:00

  • Electron energy constancy verification using a double-wedge phantom.

    abstract::Routine constancy checks of electron energy are often time consuming because of the necessity to measure a dose at two depths. A technique is described that uses a double-wedge shaped phantom positioned on a Profiler diode array for measuring an electron energy constancy metric similar to R(50). The double-wedge elect...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i3.2516

    authors: Wells DM,Picco PJ,Ansbacher W

    更新日期:2003-07-01 00:00:00

  • Improved dosimetric accuracy with semi-automatic contour propagation of organs-at-risk in glioblastoma patients undergoing chemoradiation.

    abstract:BACKGROUND:We study the changes in organs-at-risk (OARs) morphology as contoured on serial MRIs during chemoradiation therapy (CRT) of glioblastoma (GBM). The dosimetric implication of assuming non-deformable OAR changes and the accuracy and feasibility of semi-automatic OAR contour propagation are investigated. METHO...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12758

    authors: Lee S,Stewart J,Lee Y,Myrehaug S,Sahgal A,Ruschin M,Tseng CL

    更新日期:2019-12-01 00:00:00

  • Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients.

    abstract::Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12922

    authors: Branco D,Kry S,Taylor P,Rong J,Zhang X,Peterson C,Frank S,Followill D

    更新日期:2020-08-01 00:00:00

  • Assessment of PlanIQ Feasibility DVH for head and neck treatment planning.

    abstract:INTRODUCTION:Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provid...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12165

    authors: Fried DV,Chera BS,Das SK

    更新日期:2017-09-01 00:00:00

  • Commissioning of Varian ring & tandem HDR applicators: reproducibility and interobserver variability of dwell position offsets.

    abstract::Studies have shown that source dwells within Varian's HDR CT/MR compatible ring applicators can deviate from intended positions by several millimeters. Quantifying this offset is an important part of commissioning. The aims of this study were to: 1) determine the reproducibility of the offset, 2) study the interobserv...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3447

    authors: McMahon R,Zhuang T,Steffey BA,Song H,Craciunescu OI

    更新日期:2011-11-15 00:00:00

  • The development of a 4D treatment planning methodology to simulate the tracking of central lung tumors in an MRI-linac.

    abstract:PURPOSE:Targeting and tracking of central lung tumors may be feasible on the Elekta MRI-linac (MRL) due to the soft-tissue visualization capabilities of MRI. The purpose of this work is to develop a novel treatment planning methodology to simulate tracking of central lung tumors with the MRL and to quantify the benefit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12233

    authors: Al-Ward SM,Kim A,McCann C,Ruschin M,Cheung P,Sahgal A,Keller BM

    更新日期:2018-01-01 00:00:00

  • Improving a scissor-action couch for conformal arc radiotherapy and radiosurgery.

    abstract::We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob h...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v5i3.2026

    authors: Li K,Yu CX,Ma L

    更新日期:2004-07-01 00:00:00

  • Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.

    abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4600

    authors: Riegel AC,Bucci MK,Mawlawi OR,Ahmad M,Luo D,Chandler A,Pan T

    更新日期:2014-01-06 00:00:00

  • Comparison of two algorithms for determining beam weights and wedge filters.

    abstract::This article compares two algorithms for determining beam weights and wedge filters for conformal treatment planning. One algorithm, which is based on dose-gradient analysis, provides analytic formulas for determining beam weights, wedge angles, and collimator angles (i.e., wedge orientations) so that the dose distrib...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v3i3.2562

    authors: Dai J,Zhu Y

    更新日期:2002-07-01 00:00:00

  • A new homogeneity index based on statistical analysis of the dose-volume histogram.

    abstract::The goal of the present study was to develop a new dose-volume histogram (DVH)- based homogeneity index for effectively evaluating the dose homogeneity of intensity-modulated radiotherapy plans. The new index, called the sigma-index ("S-index") is defined as the standard deviation of the normalized differential DVH cu...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i2.2390

    authors: Yoon M,Park SY,Shin D,Lee SB,Pyo HR,Kim DY,Cho KH

    更新日期:2007-03-20 00:00:00

  • Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    abstract::In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3105

    authors: Yeboah C,Karotki A,Hunt D,Holly R

    更新日期:2010-06-15 00:00:00

  • Quantitative analysis of image quality for acceptance and commissioning of an MRI simulator with a semiautomatic method.

    abstract::Magnetic Resonance Imaging (MRI) simulation differs from diagnostic MRI in purpose, technical requirements, and implementation. We propose a semiautomatic method for image acceptance and commissioning for the scanner, the radiofrequency (RF) coils, and pulse sequences for an MRI simulator. The ACR MRI accreditation la...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12311

    authors: Chen X,Dai J

    更新日期:2018-05-01 00:00:00

  • Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

    abstract::The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v16i4.5350

    authors: Viel F,Lee R,Gete E,Duzenli C

    更新日期:2015-07-08 00:00:00

  • Small field electron beam dosimetry using MOSFET detector.

    abstract::The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small fi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i1.3267

    authors: Amin MN,Heaton R,Norrlinger B,Islam MK

    更新日期:2010-10-04 00:00:00

  • Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

    abstract::The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (P...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1002/acm2.12709

    authors: Zhang Y,Le AH,Tian Z,Iqbal Z,Chiu T,Gu X,Pugachev A,Reynolds R,Park YK,Lin MH,Stojadinovic S

    更新日期:2019-10-01 00:00:00