Abstract:
:Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to-background ratio (the VMSBR model). The purpose of this work was to apply the VMSBR model and six other segmentation algorithms to a sample of lung tumors. PET and 4D CT were performed in the same imaging session for 23 patients (24 tumors) for radiation therapy planning. Internal target volumes (ITVs) were autosegmented on maximum intensity projection (MIP) of cine CT. ITVs were delineated on PET using the following methods: 15%, 35%, and 42% of maximum activity concentration, standardized uptake value (SUV) of 2.5 g/mL, 15% of mean activity concentration plus background, a linear function of mean SUV, and the VMSBR model. Predicted threshold values from each method were compared to measured optimal threshold values, and resulting volume magnitudes were compared to cine-CT-derived ITV. Correlation between predicted and measured threshold values ranged from slopes of 0.29 for the simplest single-threshold techniques to 0.90 for the VMSBR technique. R2 values ranged from 0.07 for the simplest single-threshold techniques to 0.86 for the VMSBR technique. The VMSBR segmentation technique that included volume, motion, and source-to-background ratio, produced accurate ITVs in patients when compared with cine-CT-derived ITV.
journal_name
J Appl Clin Med Physjournal_title
Journal of applied clinical medical physicsauthors
Riegel AC,Bucci MK,Mawlawi OR,Ahmad M,Luo D,Chandler A,Pan Tdoi
10.1120/jacmp.v15i1.4600subject
Has Abstractpub_date
2014-01-06 00:00:00pages
4600issue
1issn
1526-9914journal_volume
15pub_type
杂志文章abstract::This study investigates the dosimetry and radiobiological model variation when a second photon arc was added to prostate volumetric-modulated arc therapy (VMAT) using the single-arc technique. Dosimetry and radiobiological model comparison between the single-arc and double-arc prostate VMAT plans were performed on fiv...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i3.4053
更新日期:2013-05-06 00:00:00
abstract::We investigate the sensitivity of IMRT commissioning using the TG-119 C-shape phantom and credentialing with the IROC head and neck phantom to treatment planning system commissioning errors. We introduced errors into the various aspects of the commissioning process for a 6X photon energy modeled using the analytical a...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5452
更新日期:2016-01-08 00:00:00
abstract::The use of solid carbon fiber table materials in radiotherapy has become more common with the implementation of image-guided radiotherapy (IGRT), since the solid materials give less imaging artifacts than the so-called tennis racket couchtops. The downside of the solid carbon fiber couch inserts is that they increase ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i4.3554
更新日期:2011-11-15 00:00:00
abstract::The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i5.5768
更新日期:2015-09-08 00:00:00
abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12462
更新日期:2018-11-01 00:00:00
abstract::The analysis of dynamic multileaf collimator (MLC) positions for the delivered intensity-modulated radiotherapy (IMRT) plans is crucial in that it may capture dose delivery problems otherwise difficult to observe and quantify in the conventional dosimetric measurements with film or with an ionization chamber. In some ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v6i2.2076
更新日期:2005-04-01 00:00:00
abstract::The purpose of this work is to prospectively assess the setup accuracy that can be achieved with a stereotactic body localizer (SBL) in immobilizing patients for stereotactic intensity-modulated radiotherapy (IMRT) for prostate cancer. By quantifying this important factor and target mobility in the SBL, we expect to p...
journal_title:Journal of applied clinical medical physics
pub_type: 临床试验,杂志文章
doi:10.1120/jacmp.v5i2.1947
更新日期:2004-04-01 00:00:00
abstract::We clarified the relationship between the display size of MRI images and observer performance using a digital contrast-detail (d-CD) phantom. The d-CD phantom was developed using Microsoft Visual Basic 2010 Express. It had a 512 × 512 matrix in size and a total of 100 holes, whose diameter increased stepwise from 4 to...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i1.5876
更新日期:2016-01-08 00:00:00
abstract::Peripheral lung lesions treated with a single fraction of stereotactic ablative body radiotherapy (SABR) utilizing volumetric modulated arc therapy (VMAT) delivery and flattening filter-free (FFF) beams represent a potentially high-risk scenario for clinically significant dose blurring effects due to interplay between...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12919
更新日期:2020-08-01 00:00:00
abstract::We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i2.5123
更新日期:2015-03-08 00:00:00
abstract::In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, gl...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i3.5200
更新日期:2015-05-08 00:00:00
abstract::A method to evaluate the electron beam energy constancy by employing the computed radiography (CR) system has been developed. In this method, a right triangular plastic wedge is used to produce a curve of the CR storage phosphor plate signal versus the wedge thickness. The curve, which resembles the percentage depth i...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v10i4.2911
更新日期:2009-10-15 00:00:00
abstract::Varian (Palo Alto, California, United States) recently released an online adaptation treatment platform, Ethos, which has introduced a new Dose Preview and Automated Plan Generation module despite sharing identical beam data with the existing Halcyon linac. The module incorporates a preconfigured beam model and the Ac...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.13056
更新日期:2020-12-01 00:00:00
abstract::Magnetic Resonance Imaging (MRI) is increasingly being used for improving tumor delineation and tumor tracking in the presence of respiratory motion. The purpose of this work is to design and build an MR compatible motion platform and to use it for evaluating the geometric accuracy of MR imaging techniques during resp...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12274
更新日期:2018-03-01 00:00:00
abstract::This study details the generation, verification, and implementation of a treatment planning system (TPS) couch top model for patient support system used in conjunction with a dedicated stereotactic linear accelerator. Couch top model was created within the TPS using CT simulation images of the kVue Calpyso-compatible ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v16i4.5441
更新日期:2015-07-08 00:00:00
abstract::Many head-and-neck cancer (HNC) patients treated with radiotherapy suffer significant anatomical changes due to tumor shrinkage or weight loss. The purpose of this study was to assess dose changes over target volumes and organs at risk during intensity-modulated radiotherapy for HNC patients. Sixteen HNC IMRT patients...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i6.3723
更新日期:2012-11-08 00:00:00
abstract:PURPOSE:To assess the noise characteristics of the new adaptive statistical iterative reconstruction (ASiR-V) in comparison to ASiR. METHODS:A water phantom was acquired with common clinical scanning parameters, at five different levels of CTDIvol . Images were reconstructed with different kernels (STD, SOFT, and BONE...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12253
更新日期:2018-03-01 00:00:00
abstract::Physical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X-rays from Novalis Tx. This in-built tertiary collimator consists of 60 pairs (32 × 0.25 cm; 26 × 0.5 cm and 2 × 0.7 cm) of leaves. Properties of HDMLC studied included alignment, readout and radiation field congruence, radiation pen...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i3.3475
更新日期:2011-04-14 00:00:00
abstract::Monte Carlo (MC)-based dose calculations are generally superior to analytical dose calculations (ADC) in modeling the dose distribution for proton pencil beam scanning (PBS) treatments. The purpose of this paper is to present a methodology for commissioning and validating an accurate MC code for PBS utilizing a parame...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12420
更新日期:2018-09-01 00:00:00
abstract::A new method of generating wedge-shaped dose distributions through dynamic multileaf collimator dose delivery rather than computer-controlled jaw motion is presented. The method starts with the calculation of a wedge-shaped beam profile for the desired wedge angle. The resultant wedge beam profile is then passed to th...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v6i3.2060
更新日期:2005-07-01 00:00:00
abstract::External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which i...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i2.3295
更新日期:2011-01-19 00:00:00
abstract::A thorax phantom was used to assess radiotherapy dose deviations induced by respiratory motion of the target volume. Both intensity modulated and static, non-modulated treatment plans were planned on CT scans of the phantom. The plans were optimized using various CT reconstructions, to investigate whether they had an ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12847
更新日期:2020-04-01 00:00:00
abstract::Prostate cancer radiotherapy workflows, solely based on magnetic resonance imaging (MRI), are now in clinical use. In these workflows, intraprostatic gold fiducial markers (GFM) show similar signal behavior as calcifications and bleeding in T2-weighted MRI-images. Accurate GFM identification in MRI-only radiotherapy w...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12478
更新日期:2018-11-01 00:00:00
abstract::Magnetic resonance imaging (MRI) is regularly used for stereotactic imaging of Gamma Knife (GK) radiosurgery patients for GK treatment planning. MRI-induced thermal injuries have occurred and been reported for GK patients with attached metallic headframes. Depending on the specific MR imaging and headframe conditions,...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v13i4.3613
更新日期:2012-07-05 00:00:00
abstract::Routine constancy checks of electron energy are often time consuming because of the necessity to measure a dose at two depths. A technique is described that uses a double-wedge shaped phantom positioned on a Profiler diode array for measuring an electron energy constancy metric similar to R(50). The double-wedge elect...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v4i3.2516
更新日期:2003-07-01 00:00:00
abstract::Hypofractionated treatments generally increase the complexity of a treatment plan due to the more stringent constraints of normal tissues and target coverage. As a result, treatment plans contain more modulated MLC motions that may require extra efforts for accurate dose calculation. This study explores methods to min...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v17i2.4989
更新日期:2016-03-08 00:00:00
abstract::We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovo...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v11i1.3146
更新日期:2010-01-28 00:00:00
abstract::We retrospectively generated IMRT plans for 14 NSCLC patients who had experienced grade 2 or 3 esophagitis (CTCAE version 3.0). We generated 11-beam and reduced esophagus dose plan types to compare changes in the volume and length of esophagus receiving doses of 50, 55, 60, 65, and 70 Gy. Changes in planning target vo...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v14i4.4248
更新日期:2013-07-08 00:00:00
abstract::Locally advanced non-small-cell lung cancer (NSCLC) is a common disease with a low overall survival even with aggressive treatments. Standard imaging (CT and PET/CT) provide no information about normal lung function. We therefore, sought to pilot HeMRI in patients with non-small-cell lung cancer before and after defin...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1120/jacmp.v12i2.3357
更新日期:2011-01-31 00:00:00
abstract:PURPOSE:Although breast density is considered a strong risk factor of breast cancer, its quantitative assessment is difficult. To investigate a quantitative method of measuring breast density using dual-energy mammographic imaging with central digital breast tomosynthesis in physically uniform and nonuniform phantoms. ...
journal_title:Journal of applied clinical medical physics
pub_type: 杂志文章
doi:10.1002/acm2.12618
更新日期:2019-06-01 00:00:00