Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy.

Abstract:

PURPOSE:The objective of this study was to evaluate the impact of the magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and range in pencil beam scanning proton therapy. METHODS:"Field regulation" - a feature to reduce the switching time between layers by applying a magnetic field setpoint (instead of a current setpoint) has been implemented on the proton beam delivery system at the Miami Cancer Institute. To investigate the impact of field regulation for the volumetric repainting technique, several spot maps were generated with beam delivery sequence in both directions, that is, irradiating from the deepest layer to the most proximal layer ("down" direction) as well as irradiating from the most proximal layer to the deepest layer ("up" direction). Range measurements were performed using a multi-layer ionization chamber array. Spot positions were measured using two-dimensional and three-dimensional scintillation detectors. For range and central-axis spot position, spot maps were delivered for energies ranging from 70-225 MeV. For off-axis spot positions, the maps were delivered for high-, medium, and low-energies at eight different gantry angles. The results were then compared between the "up" and "down" directions. RESULTS:The average difference in range for given energy between "up" and "down" directions was 0.0 ± 0.1 mm. The off-axis spot position results showed that 846/864 of the spots were within ±1 mm, and all off-axis spot positions were within ±1.2 mm. For spots (n = 126) at the isocenter, the evaluation between "up" and "down" directions for given energy showed the spot position difference within ±0.25 mm. At the nozzle entrance, the average differences in X and Y positions for given energy were 0.0 ± 0.2 mm and -0.0 ± 0.4 mm, respectively. At the nozzle exit, the average differences in X and Y positions for given energy were 0.0 ± 0.1 mm and -0.1 ± 0.1 mm, respectively. CONCLUSION:The volumetric repainting technique in magnetic field regulation mode resulted in acceptable spot position and range differences for our beam delivery system. The range differences were found to be within ±1 mm (TG224). For the spot positions (TG224: ±1 mm), the central axis measurements were within ±1 mm, whereas for the off-axis measurements, 97.9% of the spots were within ±1 mm, and all spots were within ±1.2 mm.

journal_name

J Appl Clin Med Phys

authors

Rana S,Bennouna J,Gutierrez AN,Rosenfeld AB

doi

10.1002/acm2.13045

subject

Has Abstract

pub_date

2020-10-15 00:00:00

issn

1526-9914

pub_type

杂志文章
  • Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification.

    abstract::Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i2.4111

    authors: Casanova Borca V,Pasquino M,Russo G,Grosso P,Cante D,Sciacero P,Girelli G,La Porta MR,Tofani S

    更新日期:2013-03-04 00:00:00

  • Gemstone spectral imaging: determination of CT to ED conversion curves for radiotherapy treatment planning.

    abstract::The monochromatic images acquired by Gemstone spectral imaging (GSI) mode on the GE CT750 HD theoretically determines the computed tomography (CT) number more accurately than that of conventional scanner. Using the former, the CT number is calculated from (synthesized) monoenergetic X-ray data. We reasoned that the mo...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i5.4335

    authors: Yagi M,Ueguchi T,Koizumi M,Ogata T,Yamada S,Takahashi Y,Sumida I,Akino Y,Konishi K,Isohashi F,Tomiyama N,Yoshioka Y,Ogawa K

    更新日期:2013-09-06 00:00:00

  • Understanding the impact of RapidArc therapy delivery errors for prostate cancer.

    abstract::The purpose of this study is to simulate random and systematic RapidArc delivery errors for external beam prostate radiotherapy plans in order to determine the dose sensitivity for each error type. Ten prostate plans were created with a single 360° arc. The DICOM files for these treatment plans were then imported into...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3409

    authors: Oliver M,Bush K,Zavgorodni S,Ansbacher W,Beckham WA

    更新日期:2011-05-20 00:00:00

  • Method and phantom to study combined effects of in-plane (x,y) and z-axis resolution for 3D CT imaging.

    abstract::Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in-plane (x,y) and z-axis (slice thickness) inf...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i5.6294

    authors: Goodenough D,Levy J,Kristinsson S,Fredriksson J,Olafsdottir H,Healy A

    更新日期:2016-09-08 00:00:00

  • Defining internal target volume using positron emission tomography for radiation therapy planning of moving lung tumors.

    abstract::Substantial disagreement exists over appropriate PET segmentation techniques for non-small cell lung cancer. Currently, no segmentation algorithm explicitly considers tumor motion in determining tumor borders. We developed an automatic PET segmentation model as a function of target volume, motion extent, and source-to...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i1.4600

    authors: Riegel AC,Bucci MK,Mawlawi OR,Ahmad M,Luo D,Chandler A,Pan T

    更新日期:2014-01-06 00:00:00

  • Voxel-based supervised machine learning of peripheral zone prostate cancer using noncontrast multiparametric MRI.

    abstract:PURPOSE:The aim of this study was to develop and assess the performance of supervised machine learning technique to classify magnetic resonance imaging (MRI) voxels as cancerous or noncancerous using noncontrast multiparametric MRI (mp-MRI), comprised of T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12992

    authors: Gholizadeh N,Simpson J,Ramadan S,Denham J,Lau P,Siddique S,Dowling J,Welsh J,Chalup S,Greer PB

    更新日期:2020-10-01 00:00:00

  • A study of GafChromic XR Type R film response with reflective-type densitometers and economical flatbed scanners.

    abstract::The GafChromic XR Type R film is a relatively new product for recording high radiation dose in interventional radiological procedures. Means of measuring the film response were studied in this investigation. Two handheld reflective-type densitometers of different models were compared in the range of 0-8 Gy. They were ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v4i4.2501

    authors: Thomas G,Chu RY,Rabe F

    更新日期:2003-10-01 00:00:00

  • CT and MR image fusion of tandem and ring applicator using rigid registration in intracavitary brachytherapy planning.

    abstract::The purpose of this study is to find the uncertainties in the reconstruction of MR compatible ring-tandem intracavitary applicators of high-dose rate image-based brachytherapy treatment planning using rigid registration of 3D MR and CT image fusion. Tandem and ring reconstruction in MR image based brachytherapy planni...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i2.4206

    authors: Oinam AS,Tomar P,Patel FD,Singh L,Rai B,Bahl A

    更新日期:2014-03-06 00:00:00

  • Maximum MLC opening effect in dynamic delivery of IMRT: leaf-positional analysis.

    abstract::The analysis of dynamic multileaf collimator (MLC) positions for the delivered intensity-modulated radiotherapy (IMRT) plans is crucial in that it may capture dose delivery problems otherwise difficult to observe and quantify in the conventional dosimetric measurements with film or with an ionization chamber. In some ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v6i2.2076

    authors: Zygmanski P,Hacker F,Friesen S,Rodenbush R,Lu HM,Chin L

    更新日期:2005-04-01 00:00:00

  • Reproducibility in patient-specific IMRT QA.

    abstract::The purpose of this study was to determine the reproducibility of patient-specific, intensity-modulated radiation therapy (IMRT) quality assurance (QA) results in a clinical setting. Six clinical patient plans were delivered to a variety of devices and analyses, including 1) radiographic film; 2) ion chamber; 3) 2D di...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i3.4741

    authors: McKenzie EM,Balter PA,Stingo FC,Jones J,Followill DS,Kry SF

    更新日期:2014-05-08 00:00:00

  • Comparison of TG-43 dosimetric parameters of brachytherapy sources obtained by three different versions of MCNP codes.

    abstract::Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elem...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v17i2.5797

    authors: Zaker N,Zehtabian M,Sina S,Koontz C,Meigooni AS

    更新日期:2016-03-08 00:00:00

  • Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    abstract::In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v11i3.3105

    authors: Yeboah C,Karotki A,Hunt D,Holly R

    更新日期:2010-06-15 00:00:00

  • Hepatic encephalopathy: a neurochemical, neuroanatomical, and neuropsychological study.

    abstract::Hepatic encephalopathy (HE) is normally diagnosed by neuropsychological (NP) tests, which are not very specific and do not reveal the underlying pathology. Magnetic resonance imaging (MRI) and spectroscopy (MRS) of the brain offer alternative and possibly more specific markers for HE. These methods were applied in con...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i1.2151

    authors: Binesh N,Huda A,Thomas MA,Wyckoff N,Bugbee M,Han S,Rasgon N,Davanzo P,Sayre J,Guze B,Martin P,Fawzy F

    更新日期:2006-01-01 00:00:00

  • Evaluation of offline adaptive planning techniques in image-guided brachytherapy of cervical cancer.

    abstract::Modern three-dimensional image-guided intracavitary high dose rate (HDR) brachytherapy is often used in combination with external beam radiotherapy (EBRT) to manage cervical cancer. Intrafraction motion of critical organs relative to the HDR applicator in the time between the planning CT and treatment delivery can cau...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12462

    authors: Liu H,Kinard J,Maurer J,Shang Q,Vanderstraeten C,Hayes L,Sintay B,Wiant D

    更新日期:2018-11-01 00:00:00

  • Dosimetric benefits of respiratory gating: a preliminary study.

    abstract::In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (C...

    journal_title:Journal of applied clinical medical physics

    pub_type: 临床试验,杂志文章

    doi:10.1120/jacmp.26.146

    authors: Butler LE,Forster KM,Stevens CW,Bloch C,Liu HH,Tucker SL,Komaki R,Liao Z,Starkschall G

    更新日期:2004-01-01 00:00:00

  • Production of neutrons in laminated barriers of radiotherapy rooms: comparison between the analytical methodology and Monte Carlo simulations.

    abstract::The necessity to build or adapt radiotherapy rooms in reduced areas leads to the search for unconventional solutions for shielding projects. In most cases, adding metals to the primary barriers is the best alternative to shield rooms properly. However, when photons with energies equal or higher than 10 MV interact wit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i6.5035

    authors: Rezende GF,Da Rosa LA,Facure A

    更新日期:2014-11-08 00:00:00

  • Dependence of intrafraction motion on fraction duration for pediatric patients with brain tumors.

    abstract::The purpose of this study was to quantify the intrafraction motion of pediatric patients with brain tumors during radiation therapy and investigate any correlation between motion, use of general anesthesia, and daily treatment duration. 100 pediatric patients with a mean age of 8.5 years (range: 1.0 to 17.8) were incl...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i4.3609

    authors: Beltran C,Merchant TE

    更新日期:2011-11-15 00:00:00

  • Feasibility of the new copper pipe method for evaluating half-value layer in computed tomography: A measurement and Monte Carlo simulation study.

    abstract::This study aimed to verify the accuracy of half-value layer (HVL) measured using the new copper pipe method with the CT ionization chamber while the X-ray tube is rotating and to compare it with the conventional nonrotating method and Monte Carlo simulation method based on the actual measurement and geometry of the ne...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12780

    authors: Okubo R,Matsubara K,Chusin T,Hibino T,Ito Y

    更新日期:2019-12-01 00:00:00

  • Long term stability of a 50 kV X-ray unit for stereotactic irradiation.

    abstract::A low-energy (50 kV) X-ray tube used for the stereotactic irradiation of intracranial lesions has been in use since 1999. The unit is calibrated prior to every procedure and during periodic quality assurance (QA) tests. The unit uses an internal and an external scintillation detector to monitor dose as well as a conve...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v7i3.2238

    authors: Biggs PJ

    更新日期:2006-08-24 00:00:00

  • Clinical and imaging characteristics of breast ductal carcinoma in situ with microinvasion.

    abstract:BACKGROUND:We analyzed the clinical and imaging characteristics of patients with breast ductal carcinoma in situ with microinvasion (DCISM) and breast ductal carcinoma in situ (DCIS). METHODS:We analyzed the records of 40 patients diagnosed with DCISM and 61 patients with DCIS who were hospitalized at Shengjing Hospit...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13122

    authors: Han S,Qiu F,Han Y,Xu Y,Yin J,Xing F,Bian X,He G

    更新日期:2020-12-17 00:00:00

  • Small field electron beam dosimetry using MOSFET detector.

    abstract::The dosimetry of very small electron fields can be challenging due to relative shifts in percent depth-dose curves, including the location of dmax, and lack of lateral electronic equilibrium in an ion chamber when placed in the beam. Conventionally a small parallel plate chamber or film is utilized to perform small fi...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i1.3267

    authors: Amin MN,Heaton R,Norrlinger B,Islam MK

    更新日期:2010-10-04 00:00:00

  • Effect of skull shape approximations in Gamma Knife dose calculations.

    abstract::Doses in Leksell GammaPlan (Elekta, Stockholm, Sweden) are calculated for each shot by summing the contribution from the 201 radiation beams emitted by the Gamma Knife (Elekta), weighted for attenuation in the tissue traversed. The patient's head is modeled based on 24 skull measurements, from which the depth to the c...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v8i3.2377

    authors: Berndt A,Beck J

    更新日期:2007-07-17 00:00:00

  • Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers.

    abstract::The increasing popularity of intensity-modulated arc therapy (IMAT) treatments requires specifically designed linac quality assurance (QA) programs. Gantry angle is one of the parameters that has a major effect on the outcome of IMAT treatments since dose reconstruction for patient-specific QA relies on the gantry ang...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v13i6.3981

    authors: Rowshanfarzad P,Sabet M,O'Connor DJ,McCowan PM,McCurdy BM,Greer PB

    更新日期:2012-11-08 00:00:00

  • Characterization of an inorganic scintillator for small-field dosimetry in MR-guided radiotherapy.

    abstract:INTRODUCTION:Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B). METHODS:The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, an...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.13012

    authors: Cusumano D,Placidi L,D'Agostino E,Boldrini L,Menna S,Valentini V,De Spirito M,Azario L

    更新日期:2020-09-01 00:00:00

  • Quantitative variations in texture analysis features dependent on MRI scanning parameters: A phantom model.

    abstract:OBJECTIVES:To evaluate the influence of MRI scanning parameters on texture analysis features. METHODS:Publicly available data from the Reference Image Database to Evaluate Therapy Response (RIDER) project sponsored by The Cancer Imaging Archive included MRIs on a phantom comprised of 18 25-mm doped, gel-filled tubes, ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12482

    authors: Buch K,Kuno H,Qureshi MM,Li B,Sakai O

    更新日期:2018-11-01 00:00:00

  • A clinical 3D/4D CBCT-based treatment dose monitoring system.

    abstract::To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx-Dose) reconstruction system based on three-dimensional (3D)/four-dimensional (4D)-cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for ...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12474

    authors: Qin A,Gersten D,Liang J,Liu Q,Grill I,Guerrero T,Stevens C,Yan D

    更新日期:2018-11-01 00:00:00

  • Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

    abstract::Physical and dosimetric characteristics of HDMLC were studied for SRS6, 6, and 10 MV X-rays from Novalis Tx. This in-built tertiary collimator consists of 60 pairs (32 × 0.25 cm; 26 × 0.5 cm and 2 × 0.7 cm) of leaves. Properties of HDMLC studied included alignment, readout and radiation field congruence, radiation pen...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v12i3.3475

    authors: Sharma DS,Dongre PM,Mhatre V,Heigrujam M

    更新日期:2011-04-14 00:00:00

  • Linac-based stereotactic radiosurgery (SRS) in the treatment of refractory trigeminal neuralgia: Detailed description of SRS procedure and reported clinical outcomes.

    abstract:PURPOSE/OBJECTIVES:To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS:Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatm...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1002/acm2.12057

    authors: Pokhrel D,Sood S,McClinton C,Saleh H,Badkul R,Jiang H,Stepp T,Camarata P,Wang F

    更新日期:2017-03-01 00:00:00

  • Commissioning and validation of BrainLAB cones for 6X FFF and 10X FFF beams on a Varian TrueBeam STx.

    abstract::Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the co...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v14i6.4493

    authors: Wiant DB,Terrell JA,Maurer JM,Yount CL,Sintay BJ

    更新日期:2013-11-04 00:00:00

  • Effect of RTOG breast/chest wall guidelines on dose-volume histogram parameters.

    abstract::Treatment planning for breast cancer has been traditionally based on clinical landmarks. The Radiation Therapy Oncology Group (RTOG) published consensus guidelines on contouring target volumes (TV) for the breast/chest wall and draining lymphatics. The effect of these guidelines on dosimetric parameters in surrounding...

    journal_title:Journal of applied clinical medical physics

    pub_type: 杂志文章

    doi:10.1120/jacmp.v15i2.4547

    authors: Rudra S,Al-Hallaq HA,Feng C,Chmura SJ,Hasan Y

    更新日期:2014-03-06 00:00:00