Protein binding of atracurium and other short-acting neuromuscular blocking agents and their interaction with human cholinesterases.

Abstract:

:The interaction of three new non-depolarizing neuromuscular blocking agents--atracurium, vecuronium and Duador--on human red cell acetylcholinesterase (AChE; EC 3.1.1.7) and human plasma butyrylcholinesterase (BuChE; EC 3.1.1.8) was investigated. The binding of these neuromuscular blockers to human plasma proteins (protein binding) was also studied with a new method not requiring dialysis. For sake of comparison the protein binding and the interaction of tubocurarine and pancuronium with AChE and BuChE were observed also. None of the drugs studied was a substrate of AChE or BuChE. All had a relatively weak inhibitory effect on AChE (I50 greater than 10(-5) mol litre-1 in assay systems containing 5% haemolysed red cells). Of the three new neuromuscular blockers, vecuronium and Duador were relatively potent inhibitors of BuChE (I50 less than 10(-5) mol litre-1 in assay systems containing 5% plasma), but less potent than pancuronium (I50 = 6.1 X 10(-8) mol litre-1). All neuromuscular blocking drugs tested, especially vecuronium and pancuronium, were strongly (77-91%) bound to plasma proteins.

journal_name

Br J Anaesth

authors

Foldes FF,Deery A

subject

Has Abstract

pub_date

1983-01-01 00:00:00

pages

31S-34S

eissn

0007-0912

issn

1471-6771

journal_volume

55 Suppl 1

pub_type

杂志文章
  • Spontaneous recovery of the thumb twitch from neuromuscular block by suxamethonium in anaesthetized man.

    abstract::The neuromuscular blocking effect of repeated bolus administration of suxamethonium 1 mg/kg was observed in 10 healthy surgical patients under enflurane-nitrous oxide-oxygen anaesthesia. Tachyphylaxis and slow recovery of the thumb twitch occurred in close dose-relationships with transition of Phase I block to Phase I...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/48.2.91

    authors: Lee C,Chen D,Nagel EL,Katz RL

    更新日期:1976-02-01 00:00:00

  • Aged erythrocytes: a fine wine or sour grapes?

    abstract::Blood transfusion saves many lives but carries significant risk of injury. Currently, red blood cell (RBC) concentrates can be stored up to 42 days. Concerns have recently been raised about the safety and efficacy of transfusing stored RBCs. Refrigerated storage results in a 'storage lesion' that is reflected by metab...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1093/bja/aet405

    authors: Cohen B,Matot I

    更新日期:2013-12-01 00:00:00

  • Postoperative analgesia with Duromorph.

    abstract::The analgesic effects and bioavailability of a slow-release preparation of morphine (Duromorph) were studied in 12 patients with acute postoperative pain. Duromorph produced significant analgesia within 1-2 h of administration i.m., and there was a progressive decrease in the mean pain score for at least 8 h. None of ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/57.10.949

    authors: Charway CL,Calvey TN,Williams NE,Murray GR

    更新日期:1985-10-01 00:00:00

  • Accuracy of new gas flowmeters.

    abstract::The accuracy of five new oxygen and nitrous oxide flowmeter units was investigated using the bubble meter method. The results were compared with those previously found in flowmeters withdrawn from clinical use. New oxygen flowmeters demonstrated less inaccuracies than old flowmeters. No differences were found between ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/52.1.97

    authors: Waaben J,Brinkløv MM,Stokke DB

    更新日期:1980-01-01 00:00:00

  • Perioperative tobacco use interventions in Japan: a survey of thoracic surgeons and anaesthesiologists.

    abstract:BACKGROUND:Tobacco use interventions in surgical patients who smoke could benefit both their short-term outcome and long-term health. Anaesthesiologists and surgeons can play key roles in delivering these interventions. This study determined the practices, attitudes, and beliefs of these physicians regarding tobacco us...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,多中心研究

    doi:10.1093/bja/aem400

    authors: Kai T,Maki T,Takahashi S,Warner DO

    更新日期:2008-03-01 00:00:00

  • Large volume N2O uptake alone does not explain the second gas effect of N2O on sevoflurane during constant inspired ventilation.

    abstract:BACKGROUND:The second gas effect (SGE) is considered to be significant only during periods of large volume N(2)O uptake (VN(2)O); however, the SGE of small VN(2)O has not been studied. We hypothesized that the SGE of N(2)O on sevoflurane would become less pronounced when sevoflurane administration is started 60 min aft...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1093/bja/ael008

    authors: Hendrickx JF,Carette R,Lemmens HJ,De Wolf AM

    更新日期:2006-03-01 00:00:00

  • Revised cardiac risk index and postoperative morbidity after elective orthopaedic surgery: a prospective cohort study.

    abstract:BACKGROUND:The revised cardiac risk index (RCRI) is associated strongly with increased cardiac ischaemic risk and perioperative death. Associations with non-cardiac morbidity in non-cardiac surgery have not been explored. In the elective orthopaedic surgical population, morbidity is common but preoperative predictors a...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,多中心研究

    doi:10.1093/bja/aeq245

    authors: Ackland GL,Harris S,Ziabari Y,Grocott M,Mythen M,SOuRCe Investigators.

    更新日期:2010-12-01 00:00:00

  • Postoperative hypoxaemia and oxygen therapy.

    abstract::Arterial blood and expired gas samples were taken from 20 patients before operation and on the first day after upper abdominal surgery. After operation the patients were studied breathing air and also breathing 35% oxygen from a venturi-type mask. Preoperative Pao2 with age was exaggerated by operation. Pao2 after ope...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/47.4.491

    authors: Drummond GB

    更新日期:1975-04-01 00:00:00

  • Total i.v. anaesthesia with propofol and alfentanil: dose requirements for propofol and the effect of premedication with clonidine.

    abstract::We determined in 51 healthy patients undergoing body surface surgery the dose requirements for propofol, as part of a total i.v. anaesthesia technique with an alfentanil infusion. After premedication with temazepam, patients received alfentanil 50 micrograms kg-1 followed by an infusion of 50 micrograms kg-1 h-1. Pati...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1093/bja/65.2.157

    authors: Richards MJ,Skues MA,Jarvis AP,Prys-Roberts C

    更新日期:1990-08-01 00:00:00

  • Post-tetanic count and single twitch height at the onset of reflex movement after administration of vecuronium under different types of anaesthesia.

    abstract::We have studied post-tetanic count (PTC) and single twitch height at the onset of reflex movement to carinal stimulation after administration of vecuronium with five different types of anaesthesia. Seventy-five adult patients were allocated randomly to five groups of 15 patients each, to receive one of the following a...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验,收录出版

    doi:10.1093/bja/72.6.688

    authors: Saitoh Y,Kaneda K,Toyooka H,Amaha K

    更新日期:1994-06-01 00:00:00

  • A microprocessor-controlled gas mixing device.

    abstract::This paper describes the use of solenoid valves for the production of binary gas mixtures. The system is controlled by a microprocessor and is capable of delivering accurate flows and concentrations of gases over the ranges commonly used in anaesthesia. Since the flow produced by the valves is pulsatile, a system for ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/58.9.1041

    authors: Palayiwa E,Hahn CE,Sugg BR,Lindsay-Scott D,Tyrrell PJ

    更新日期:1986-09-01 00:00:00

  • Accuracy and precision of the ultrasound cardiac output monitor (USCOM 1A) in pregnancy: comparison with three-dimensional transthoracic echocardiography.

    abstract:BACKGROUND:Cardiac output (CO) monitoring is helpful in the assessment of critically ill pregnant women, but invasive monitors are often unsuitable for use. We aimed to measure agreement between the non-invasive ultrasound cardiac output monitor (USCOM) and three-dimensional transthoracic echocardiography (3D-TTE) in p...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aeu162

    authors: McNamara H,Barclay P,Sharma V

    更新日期:2014-10-01 00:00:00

  • Anaesthesia for a patient undergoing transthoracic endoscopic vagotomy.

    abstract::We describe the anaesthetic management of a patient who underwent transthoracic endoscopic vagotomy. One-lung ventilation was necessary to provide adequate surgical access. Potential intraoperative problems involved arterial oxygen saturation during one-lung ventilation, unequal intrathoracic pressures causing mediast...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/68.3.318

    authors: Chui PT,Gin T,Chung SC

    更新日期:1992-03-01 00:00:00

  • Suspected opioid-induced hyperalgesia in an infant.

    abstract::One explanation for diminished opioid analgesic efficacy is opioid-induced hyperalgesia (OIH). We report a case of OIH in an infant with gastroschisis, requiring multiple surgical interventions and prolonged sedation for ventilation. This is the first report of OIH in an infant. On day 41 of life after nine separate s...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aer332

    authors: Hallett BR,Chalkiadis GA

    更新日期:2012-01-01 00:00:00

  • Comparison of chloral hydrate and midazolam by mouth as premedicants in children undergoing otolaryngological surgery.

    abstract::Chloral hydrate 25, 50 or 75 mg kg-1 or midazolam 0.4, 0.5 or 0.6 mg kg-1, all given by mouth in combination with atropine 0.03 mg kg-1, were compared as premedication in 248 children in a randomized, double-blind study. Chloral hydrate was significantly less palatable than midazolam. The anxiolytic effect of chloral ...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/61.4.390

    authors: Saarnivaara L,Lindgren L,Klemola UM

    更新日期:1988-10-01 00:00:00

  • Inspired oxygen fraction after cardiopulmonary bypass: effects on pulmonary function with regard to endothelin-1 concentrations and venous admixture.

    abstract::Twenty consecutive patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) were allocated at random to group 1 (n = 10, high inspired oxygen fraction (FIO2) after CPB), or group 2 (n = 10, moderate FIO2 after CPB). The effects of each FIO2 on arterial and mixed venous concentrations of endothelin-1 (ET-1...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/84.5.565

    authors: Reber A,Budmiger B,Wenk M,Haefeli WE,Wolff T,Bein T,Skarvan K

    更新日期:2000-05-01 00:00:00

  • Contralateral effect of amitriptyline and bupivacaine for sciatic nerve block in an animal model of inflammation.

    abstract:BACKGROUND:Using a carrageenan inflammation rat model, we evaluated two experimental approaches to prolong sciatic nerve block on contralateral hyperalgesia. Method. We performed ipsilateral sciatic nerve block on the inflamed hind paw with bupivacaine-loaded microspheres suspended in dexamethasone (bupivacaine 12.5 mg...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aeh264

    authors: Estebe JP,Gentili ME,Le Corre P,Leduc C,Moulinoux JP,Ecoffey C

    更新日期:2004-11-01 00:00:00

  • Evaluation of a disposable patient-controlled analgesia device in children.

    abstract::A disposable patient-controlled analgesia (PCA) device was evaluated in 20 children after major abdominal, urological and orthopaedic surgery. All patients were given a high dependency level of nursing care in general wards. Efficacy (as assessed by hourly pain scores) was comparable to that achieved in a matched cont...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/68.4.411

    authors: Irwin M,Gillespie JA,Morton NS

    更新日期:1992-04-01 00:00:00

  • Acoustic monitoring of intraoperative neuromuscular block.

    abstract::Standard methods for accurate intraoperative measurement of neuromuscular block are either expensive or inconvenient and are not used widely. We have evaluated a new method of monitoring neuromuscular block using a low-frequency microphone. The method is based on the phenomenon of low-frequency sound emission by contr...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1093/bja/83.3.405

    authors: Dascalu A,Geller E,Moalem Y,Manoah M,Enav S,Rudick Z

    更新日期:1999-09-01 00:00:00

  • Recordings of, and an anatomical explanation for, false positive loss of resistance during lumbar extradural analgesia.

    abstract::Loss of resistance dorsal to the ligamentum flavum was recorded in 10 of 16 patients aged 43--75 yr whilst performing extradural anaesthesia at the L2--3 interspace via the midline approach. Degeneration of the interspinous ligament with cavity formation is observed frequently in the elderly and may account for false ...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/51.3.253

    authors: Sharrock NE

    更新日期:1979-03-01 00:00:00

  • Comparison of bispectral index, 95% spectral edge frequency and approximate entropy of the EEG, with changes in heart rate variability during induction of general anaesthesia.

    abstract::We have compared bispectral index (BIS), 95% spectral edge frequency (SEF) and approximate entropy (ApEn) in 37 patients during induction and recovery from a short general anaesthetic. Heart rate variability (HRV) was also compared during induction only. These indices were noted at the start of induction, when a syrin...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1093/bja/82.5.666

    authors: Sleigh JW,Donovan J

    更新日期:1999-05-01 00:00:00

  • Recovery after total intravenous general anaesthesia or spinal anaesthesia for total knee arthroplasty: a randomized trial.

    abstract:BACKGROUND:This study was undertaken to compare the effects of general anaesthesia (GA) and spinal anaesthesia (SA) on the need for postoperative hospitalization and early postoperative comfort in patients undergoing fast-track total knee arthroplasty (TKA). METHODS:One hundred and twenty subjects were randomly alloca...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1093/bja/aet104

    authors: Harsten A,Kehlet H,Toksvig-Larsen S

    更新日期:2013-09-01 00:00:00

  • Comparison of the laryngoscopy views with the size 1 Miller and Macintosh laryngoscope blades lifting the epiglottis or the base of the tongue in infants and children

    abstract:BACKGROUND:Miller laryngoscope blades are preferred for laryngoscopy in infants and children <2 yr of age. Despite their long history, the laryngeal view with the Miller blade size 1 has never been compared with that with the Macintosh (MAC) blade in children. This prospective, single-blinded, randomized study was desi...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1093/bja/aeu228

    authors: Passi Y,Sathyamoorthy M,Lerman J,Heard C,Marino M

    更新日期:2014-11-01 00:00:00

  • Baroreceptor control of regional haemodynamics during halothane anaesthesia in the dog.

    abstract::Regional haemodynamic control by the cardiovascular baroreceptors was examined in dogs anaesthetized with 1 + MAC halothane in oxygen (1%). The open-loop relationships between carotid sinus pressure (CSP) and regional haemodynamics in the iliac, renal, mesenteric, aortic and coeliac beds were examined before vagotomy,...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/49.6.535

    authors: Bagshaw RJ,Cox RH

    更新日期:1977-06-01 00:00:00

  • Pharmacokinetics of Org NC45 (norcuron) in patients with and without renal failure.

    abstract::To determine the influence of renal failure on the pharmacokinetics and neuromuscular blockade of Org NC 45 (Norcuron), a new monoquaternary homologue of pancuronium, 13 patients under halothane and nitrous oxide anesthesia were studied. Org NC 45 was administered by 2-min infusion in doses of 0.28 mg kg-1 (normal ren...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/53.10.1049

    authors: Fahey MR,Morris RB,Miller RD,Nguyen TL,Upton RA

    更新日期:1981-10-01 00:00:00

  • Determinants of outcome in critically ill octogenarians after surgery: an observational study.

    abstract:BACKGROUND:The population in the UK is growing older and the number of elderly patients cared for on intensive care units (ICU) is increasing. This study was designed to identify risk factors for mortality in critically ill patients of >80 yr of age after surgery. METHODS:We identified 275 patients, aged 80 yr or grea...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章

    doi:10.1093/bja/aem307

    authors: Ford PN,Thomas I,Cook TM,Whitley E,Peden CJ

    更新日期:2007-12-01 00:00:00

  • Impact of phenylephrine administration on cerebral tissue oxygen saturation and blood volume is modulated by carbon dioxide in anaesthetized patients.

    abstract:BACKGROUND:Multiple studies have shown that cerebral tissue oxygen saturation (Sct(O(2))) is decreased after phenylephrine treatment. We hypothesized that the negative impact of phenylephrine administration on Sct(O(2)) is affected by arterial blood carbon dioxide partial pressure (Pa(CO(2))) because CO(2) is a powerfu...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1093/bja/aes023

    authors: Meng L,Gelb AW,Alexander BS,Cerussi AE,Tromberg BJ,Yu Z,Mantulin WW

    更新日期:2012-05-01 00:00:00

  • Gasless laparoscopic cholecystectomy: comparison of postoperative recovery with conventional technique.

    abstract::We have compared, in a randomized study in 26 patients, immediate and late postoperative recovery after elective laparoscopic cholecystectomy using the gasless, mechanical abdominal wall lift method with conventional carbon dioxide pneumoperitoneum. After the gasless method, tracheal extubation was performed significa...

    journal_title:British journal of anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/bja/77.5.576

    authors: Koivusalo AM,Kellokumpu I,Lindgren L

    更新日期:1996-11-01 00:00:00

  • Anaesthesia and sleep apnoea.

    abstract::Sleep disordered breathing is a common problem affecting all age groups, particularly in association with certain other medical conditions and syndromes. The pathological consequences of the disorder may be severe, with significant implications for the perioperative management of sufferers. Research into the effects o...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1093/bja/86.2.254

    authors: Loadsman JA,Hillman DR

    更新日期:2001-02-01 00:00:00

  • Analysis of individual patient data from clinical trials: epidural morphine for postoperative pain.

    abstract:BACKGROUND:Individual patient information from clinical trials is infrequently available, but can provide insights for clinical trials and practice. METHODS:We analysed individual patient information from five randomized trials (913 patients) of i.v. patient-controlled analgesia (IVPCA) plus epidural placebo, morphine...

    journal_title:British journal of anaesthesia

    pub_type: 杂志文章,meta分析

    doi:10.1093/bja/aep300

    authors: Mhuircheartaigh RJ,Moore RA,McQuay HJ

    更新日期:2009-12-01 00:00:00