Predicting the outcome of asymptomatic univesicular liver hydatids: diagnostic accuracy of unenhanced CT.

Abstract:

OBJECTIVES:To establish the role of unenhanced CT in predicting the outcome of liver hydatid cysts. We sought to determine whether the presence of laminated membrane detachment (LMD) or pericyst degenerative changes (PDCs) detected on CT were reliable signs for predicting a favorable outcome of liver hydatids. METHODS:In a 20-year-long study, we prospectively followed changes occurred in CT of 106 cysts of 98 patients with incidentally discovered asymptomatic univesicular liver hydatids who accepted to enter a watch-and-wait program. An "unfavorable" outcome was defined as the occurrence of a complication (most commonly, cyst fistula or infection) or increase in the cyst size during the follow-up; otherwise, the outcome was considered "favorable." The parameters derived from a binary logistic regression analysis (with the outcome taken as the dependent variable), after appropriate transformation of the independent variables (presence of LMD or PDCs on CT), were used to calculate the sensitivity, specificity, positive and negative likelihood ratios, and positive and negative predictive values of the presence of either the abovementioned CT findings for the prediction of a favorable outcome. RESULTS:The presence of LMD or PDCs had a high specificity (88%) and positive predictive value (96%) for a favorable outcome; they had high false-negative rates. CONCLUSIONS:The presence of either LMD or PDCs on unenhanced CT, in incidentally discovered asymptomatic univesicular liver hydatids, was associated with a high probability of a favorable outcome. Their absence does not rule out a favorable outcome. KEY POINTS:• Computed tomography can be used for predicting the outcome of those with incidentally discovered univesicular liver hydatids. • The presence of laminated membrane detachment and/or pericyst degenerative changes is associated with a favorable outcome. • Their absence does not necessarily indicate an unfavorable outcome.

journal_name

Eur Radiol

journal_title

European radiology

authors

Habibzadeh F,Habibzadeh P,Shakibafard A,Saidi F

doi

10.1007/s00330-020-07681-0

subject

Has Abstract

pub_date

2021-01-16 00:00:00

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-07681-0

pub_type

杂志文章
  • A national patient dose survey and setting of reference levels for interventional radiology in Bulgaria.

    abstract:OBJECTIVES:A national study on patient dose values in interventional radiology and cardiology was performed in order to assess current practice in Bulgaria, to estimate the typical patient doses and to propose reference levels for the most common procedures. METHODS:Fifteen units and more than 1,000 cases were include...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-012-2386-5

    authors: Zotova R,Vassileva J,Hristova J,Pirinen M,Järvinen H

    更新日期:2012-06-01 00:00:00

  • Thoracic complications in uremic patients and in patients undergoing dialytic treatment: state of the art.

    abstract::No organ in the chest is spared the negative effects of uremia. The dialytic treatment itself is often associated with a large array of thoracic complications. We review the main thoracic manifestations of the terminal uremia from the radiological point of view, such as: uremic pleuritis and pericarditis, uremic pneum...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/BF02742931

    authors: Gavelli G,Zompatori M

    更新日期:1997-01-01 00:00:00

  • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

    abstract:OBJECTIVE:The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS:31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2062-1

    authors: Bamberg F,Dierks A,Nikolaou K,Reiser MF,Becker CR,Johnson TR

    更新日期:2011-07-01 00:00:00

  • Multiparametric computer-aided differential diagnosis of Alzheimer's disease and frontotemporal dementia using structural and advanced MRI.

    abstract:OBJECTIVES:To investigate the added diagnostic value of arterial spin labelling (ASL) and diffusion tensor imaging (DTI) to structural MRI for computer-aided classification of Alzheimer's disease (AD), frontotemporal dementia (FTD), and controls. METHODS:This retrospective study used MRI data from 24 early-onset AD an...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4691-x

    authors: Bron EE,Smits M,Papma JM,Steketee RME,Meijboom R,de Groot M,van Swieten JC,Niessen WJ,Klein S

    更新日期:2017-08-01 00:00:00

  • Correction to: Radiomics on multi-modalities MR sequences can subtype patients with non-metastatic nasopharyngeal carcinoma (NPC) into distinct survival subgroups.

    abstract::The original version of this article, published on 14 March 2019, unfortunately contained a mistake. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-019-06184-x

    authors: Zhuo EH,Zhang WJ,Li HJ,Zhang GY,Jing BZ,Zhou J,Cui CY,Chen MY,Sun Y,Liu LZ,Cai HM

    更新日期:2019-07-01 00:00:00

  • Diagnostic value of time-resolved CT angiography for the lower leg.

    abstract:OBJECTIVE:The aim of this study was to test the feasibility of time-resolved computed tomography angiography (TR-CTA) for use in the lower leg. METHODS:Fifty-nine patients with suspected peripheral arterial occlusive disease were examined with a standard CTA (S-CTA) of the lower run-off and with an additional TR-CTA o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1861-0

    authors: Sommer WH,Helck A,Bamberg F,Albrecht E,Becker CR,Weidenhagen R,Kramer H,Reiser MF,Nikolaou K

    更新日期:2010-12-01 00:00:00

  • Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method.

    abstract:OBJECTIVE:Tissue perfusion is frequently determined from dynamic contrast-enhanced CT or MRI image series by means of the steepest slope method. It was thus the aim of this study to systematically evaluate the reliability of this analysis method on the basis of simulated tissue curves. METHODS:9600 tissue curves were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1787-6

    authors: Brix G,Zwick S,Griebel J,Fink C,Kiessling F

    更新日期:2010-09-01 00:00:00

  • Diagnostic value of MRI in tuberculous meningitis.

    abstract::In this study 15 patients with clinical findings and positive cerebrospinal fluid analyses for tuberculous meningitis were evaluated with magnetic resonance imaging (MRI). Tuberculous meningitis was diagnosed in 11 cases when thick meningeal enhancement was present after intravenous injection of gadolinium diethylenet...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00180618

    authors: Tayfun C,Uçöz T,Taşar M,Ataç K,Oğur,Oztürk T,Yinanç MA

    更新日期:1996-01-01 00:00:00

  • Ultrasound-guided core-needle biopsy of the testis for focal indeterminate intratesticular lesions.

    abstract::The aim of this study was to evaluate ultrasound (US)-guided core-needle testicular biopsy. Twelve biopsies were performed in eleven patients, under US guidance using disposable 16- or 18-gauge needles, between April 2003 and October 2006. Details were entered on a database and records reviewed 9 months to 3 years aft...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1072-0

    authors: Soh E,Berman LH,Grant JW,Bullock N,Williams MV

    更新日期:2008-12-01 00:00:00

  • Development and validation of a quantitative method for estimation of the urate burden in patients with gouty arthritis using dual-energy computed tomography.

    abstract:OBJECTIVES:To develop a method that allows approximating the mass of monosodium uric acid (MSU) in a gouty tophus using phantom measurements and including tophus density into the calculation of the dual-energy computed tomography (DECT) tophus volumetry. METHODS:We prepared specimens of different concentrations of MSU...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06350-1

    authors: Kotlyarov M,Hermann KGA,Mews J,Hamm B,Diekhoff T

    更新日期:2020-01-01 00:00:00

  • Fluorescence imaging with near-infrared light: new technological advances that enable in vivo molecular imaging.

    abstract::A recent development in biomedical imaging is the non-invasive mapping of molecular events in intact tissues using fluorescence. Underpinning to this development is the discovery of bio-compatible, specific fluorescent probes and proteins and the development of highly sensitive imaging technologies for in vivo fluores...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1524-x

    authors: Ntziachristos V,Bremer C,Weissleder R

    更新日期:2003-01-01 00:00:00

  • Upright, weight-bearing, dynamic-kinetic MRI of the spine: initial results.

    abstract::The potential relative beneficial aspects of upright, weight-bearing (pMRI), dynamic-kinetic (kMRI) spinal imaging over that of recumbent MRI (rMRI) include the revelation of occult spinal disease dependent on true axial loading, the unmasking of kinetic-dependent spinal disease and the ability to scan the patient in ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2666-4

    authors: Jinkins JR,Dworkin JS,Damadian RV

    更新日期:2005-09-01 00:00:00

  • Fibrotic idiopathic interstitial pneumonias: HRCT findings that predict mortality.

    abstract:OBJECTIVES:The study aims were to identify CT features that predict outcome of fibrotic idiopathic interstitial pneumonia (IIP) when information from lung biopsy data is unavailable. METHODS:HRCTs of 146 consecutive patients presenting with fibrotic IIP were studied. Visual estimates were made of the extent of abnorma...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2098-2

    authors: Edey AJ,Devaraj AA,Barker RP,Nicholson AG,Wells AU,Hansell DM

    更新日期:2011-08-01 00:00:00

  • Neoadjuvant chemotherapy in breast cancer-response evaluation and prediction of response to treatment using dynamic contrast-enhanced and diffusion-weighted MR imaging.

    abstract:OBJECTIVE:To explore the predictive value of MRI parameters and tumour characteristics before neoadjuvant chemotherapy (NAC) and to compare changes in tumour size and tumour apparent diffusion coefficient (ADC) during treatment, between patients who achieved pathological complete response (pCR) and those who did not. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2020-3

    authors: Fangberget A,Nilsen LB,Hole KH,Holmen MM,Engebraaten O,Naume B,Smith HJ,Olsen DR,Seierstad T

    更新日期:2011-06-01 00:00:00

  • Ultrasonography has a diagnostic value in the assessment of cervical radiculopathy: A prospective pilot study.

    abstract:OBJECTIVE:This study investigated the diagnostic accuracy of the difference in the cross-sectional areas (CSAs) of affected cervical nerve roots (NRs) for diagnosing cervical radiculopathy (CR). METHODS:In total, 102 CR patients and 219 healthy volunteers were examined with ultrasound. The CSA of the cervical NR at ea...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4704-9

    authors: Takeuchi M,Wakao N,Hirasawa A,Murotani K,Kamiya M,Osuka K,Takayasu M

    更新日期:2017-08-01 00:00:00

  • Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing.

    abstract::Streak artifact is an important source of image degradation in computed tomographic imaging. In coronary MDCT angiography, streak artifact from pacemaker leads in the SVC can render segments of the right coronary artery uninterpretable. With current technology in clinical practice, there is no effective way to elimina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1013-y

    authors: Meyer LT,Boll DT

    更新日期:2008-11-01 00:00:00

  • Respiratory lumenal change of the pharynx and trachea in normal subjects and COPD patients: assessment by cine-MRI.

    abstract::The purpose of this study was to use cine-MRI during continuous respiration to measure the respiratory lumenal diameter change in the pharynx and at an upper tracheal level. Fifteen non-smokers and 23 chronic obstructive pulmonary disease (COPD) patients with smoking history (median 50 pack-years) were included. Cine-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2461-7

    authors: Heussel CP,Ley S,Biedermann A,Rist A,Gast KK,Schreiber WG,Kauczor HU

    更新日期:2004-12-01 00:00:00

  • Prognostic impact of nomogram based on whole tumour size, tumour disappearance ratio on CT and SUVmax on PET in lung adenocarcinoma.

    abstract:OBJECTIVES:Lung adenocarcinoma frequently manifests as subsolid nodules, and the solid portion and ground-glass-opacity (GGO) portion on CT have different prognostic significance. Therefore, current T descriptor, defined as the whole tumour diameter without discrimination between solid and GGO, is insufficient. We aime...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4029-0

    authors: Song SH,Ahn JH,Lee HY,Lee G,Choi JY,Kang J,Kim EY,Han J,Kwon OJ,Lee KS,Kim HK,Choi YS,Kim J,Shim YM

    更新日期:2016-06-01 00:00:00

  • Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography.

    abstract:OBJECTIVES:To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). METHODS:Fifty-three patients who underwent st...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4238-1

    authors: Tanabe Y,Kido T,Uetani T,Kurata A,Kono T,Ogimoto A,Miyagawa M,Soma T,Murase K,Iwaki H,Mochizuki T

    更新日期:2016-11-01 00:00:00

  • Invasive interval cancers in the Ostergötland Mammographic Screening Programme: radiological analysis.

    abstract::The aim of this study was to find out by radiological analysis whether it is possible to prevent interval cancers in screening programmes without a concomitant increase in false positives. Re-scrutiny of all mammograms of 544 interval cancers was implemented. Blinded re-scrutiny of screening mammograms of 390 interval...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1007/s003300050452

    authors: Vitak B

    更新日期:1998-01-01 00:00:00

  • "In-house" pharmacological management for computed tomography coronary angiography: heart rate reduction, timing and safety of different drugs used during patient preparation.

    abstract::We retrospectively evaluated the effect, timing and safety of different pharmacological strategies during 64-slice CT coronary angiography (CT-CA). From the institutional database of CT-CAwe enrolled 560 consecutive patients with suspected coronary artery disease. The type of drug preparation (group 1 = no treatment; ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1509-0

    authors: Maffei E,Palumbo AA,Martini C,Tedeschi C,Tarantini G,Seitun S,Ruffini L,Aldrovandi A,Weustink AC,Meijboom WB,Mollet NR,Krestin GP,de Feyter PJ,Cademartiri F

    更新日期:2009-12-01 00:00:00

  • Proper timing for the evaluation of neonatal brain white matter development: a diffusion tensor imaging study.

    abstract:OBJECTIVE:We aimed to determine the timing for assessing birth status of the developing brain (i.e. brain maturity at birth) by exploring the postnatal age-related changes in neonatal brain white matter (WM). METHODS:The institutional review board approved this study and all informed parental consents were obtained. 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5665-y

    authors: Jin C,Li Y,Li X,Wang M,Liu C,Gao J,Sun Q,Qiu D,Zeng L,Zhou X,Li G,Zhang J,Zheng J,Yang J

    更新日期:2019-03-01 00:00:00

  • Diffusion-weighted imaging of bone marrow: current status.

    abstract::Diffusion-weighted imaging allows for measurement of tissue microstructure and reflects the random motion of water protons. It provides a new method to study bone marrow and bone marrow alterations on the basis of altered water-proton mobility in various diseases. Different diffusion-weighted methods have proved to be...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-1873-0

    authors: Baur A,Dietrich O,Reiser M

    更新日期:2003-07-01 00:00:00

  • Non-cardiac findings on coronary computed tomography and magnetic resonance imaging.

    abstract::Both multislice computed tomography (CT) and magnetic resonance imaging (MRI) are emerging as methods to detect coronary artery stenoses and assess cardiac function and morphology. Non-cardiac structures are also amenable to assessment by these non-invasive tests. We investigated the rate of significant and insignific...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0570-1

    authors: Dewey M,Schnapauff D,Teige F,Hamm B

    更新日期:2007-08-01 00:00:00

  • Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner.

    abstract::The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6+/-1.4) who had been admitted for coronary artery bypass graft sur...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-004-2325-1

    authors: Khan MF,Herzog C,Ackermann H,Wagner TO,Maataoui A,Harth M,Abolmaali ND,Jacobi V,Vogl TJ

    更新日期:2004-08-01 00:00:00

  • Radiomic features from the peritumoral brain parenchyma on treatment-naïve multi-parametric MR imaging predict long versus short-term survival in glioblastoma multiforme: Preliminary findings.

    abstract:OBJECTIVE:Despite 90 % of glioblastoma (GBM) recurrences occurring in the peritumoral brain zone (PBZ), its contribution in patient survival is poorly understood. The current study leverages computerized texture (i.e. radiomic) analysis to evaluate the efficacy of PBZ features from pre-operative MRI in predicting long-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4637-3

    authors: Prasanna P,Patel J,Partovi S,Madabhushi A,Tiwari P

    更新日期:2017-10-01 00:00:00

  • Head-to-head comparison of multiple cardiovascular magnetic resonance techniques for the detection and quantification of intramyocardial haemorrhage in patients with ST-elevation myocardial infarction.

    abstract:OBJECTIVES:T2*-weighted (T2*w) is deemed as a reference standard for post-infarction intramyocardial haemorrhage (IMH). However, high proportion of T2* images is affected by off-resonance artefacts hampering image interpretation. Diagnostic accuracy and precision of alternative techniques for IMH diagnosis and quantifi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07254-1

    authors: Pavon AG,Georgiopoulos G,Vincenti G,Muller O,Monney P,Berchier G,Cirillo C,Eeckhout E,Schwitter J,Masci PG

    更新日期:2020-09-14 00:00:00

  • Does gadoxetate disodium affect MRE measurements in the delayed hepatobiliary phase?

    abstract:OBJECTIVES:To assess if the administration of gadoxetate disodium (Gd-EOB-DTPA) significantly affects hepatic magnetic resonance elastography (MRE) measurements in the delayed hepatobiliary phase (DHBP). METHODS:A total of 47 patients (15 females, 32 males; age range 23-78 years, mean 54.28 years) were assigned to sta...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5616-7

    authors: Plaikner M,Kremser C,Zoller H,Steurer M,Glodny B,Jaschke W,Henninger B

    更新日期:2019-02-01 00:00:00

  • Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    abstract:OBJECTIVES:Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patie...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-017-5023-5

    authors: Stacul F,Bertolotto M,Thomsen HS,Pozzato G,Ugolini D,Bellin MF,Bongartz G,Clement O,Heinz-Peer G,van der Molen A,Reimer P,Webb JAW,ESUR Contrast Media Safety Committee.

    更新日期:2018-02-01 00:00:00

  • A case of spontaneous hemorrhage of the abdominal wall caused by rupture of a deep iliac circumflex artery treated by transcatheter arterial embolization.

    abstract::We report an uncommon case of spontaneous massive hemorrhage of the abdominal wall caused by rupture of a deep iliac circumflex (DIC) artery. Enhanced computed tomography (CT) demonstrated a marked extravasation in a huge hematoma of the abdominal wall. Although a pelvic arteriogram demonstrated no extravasation, a su...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050432

    authors: Katsumori T,Nakajima K

    更新日期:1998-01-01 00:00:00