Abstract:
OBJECTIVES:T2*-weighted (T2*w) is deemed as a reference standard for post-infarction intramyocardial haemorrhage (IMH). However, high proportion of T2* images is affected by off-resonance artefacts hampering image interpretation. Diagnostic accuracy and precision of alternative techniques for IMH diagnosis and quantification have been seldomly investigated. METHODS AND RESULTS:Between April 2016 and May 2017, 50 ST-segment elevation myocardial infarction patients (66% male, 57 ± 17 years) and 15 healthy controls (60% male, 58 ± 13) were consecutively enrolled. Subjects underwent head-to-head comparison of single mid-infarct slice acquired on black-blood T2-weighted short-TI-inversion recovery (T2w-STIR), bright-blood T2prep-steady-state-free precession (T2prep-SSFP), and T2/T1 maps for IMH diagnosis and quantification against T2*w. All images were graded for quality (grade 1: very poor; grade 4: excellent) and diagnostic confidence (Likert scale, 1: very unsure and 5: highly confident). Reduced relaxation time/hypointense region (hypocore) embedded in infarct-related oedema on T2 map, T1 map, and T2w-STIR had the best overall diagnostic accuracy (per-subject: 91%, 86%, and 86%, respectively; per segment: 95%, 93%, and 93%, respectively). By mixed-effects analysis, image quality, and diagnostic confidence were higher for T2 map and T1 maps than T2*w (p < 0.05 for both scores). For IMH quantification, hypocore on T2 map and T1 map strongly correlated (Spearman's r > 0.7, p < 0.001 for both) with IMH extent on T2*w and presented an overall excellent agreement on Bland-Altman analysis. By linear mixed model analysis, absolute hypocore size did not differ among T1-, T2 map, and T2*w. T2/T1 maps had the best intra- and inter-observer reproducibility among CMR techniques. CONCLUSION:Hypocore on T2/T1 map is the best alternative technique to T2*w for diagnosing and quantifying IMH in post-STEMI patients. KEY POINT:• Mapping techniques are the best alternatives for diagnosing post-infarction intramyocardial haemorrhage. • Mapping techniques are valuable tools for imaging intramyocardial haemorrhage.
journal_name
Eur Radioljournal_title
European radiologyauthors
Pavon AG,Georgiopoulos G,Vincenti G,Muller O,Monney P,Berchier G,Cirillo C,Eeckhout E,Schwitter J,Masci PGdoi
10.1007/s00330-020-07254-1subject
Has Abstractpub_date
2020-09-14 00:00:00eissn
0938-7994issn
1432-1084pii
10.1007/s00330-020-07254-1pub_type
杂志文章abstract:OBJECTIVES:The purpose of this study was to assess the protective effect of premedication and changing contrast media (CM) against repeat adverse reactions (ARs) to iodinated CM. METHODS:Between January 2006 and September 2014, 771 cases with previous ARs to CM were administered CM. The same CM that had caused ARs pre...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4028-1
更新日期:2016-07-01 00:00:00
abstract::This was a radiologists' preference study to compare a digital chest radiography system that utilizes a large-area silicon flat-panel detector with conventional radiography for visualizing anatomic regions of the chest. Conventional and digital posteroanterior (PA) and lateral chest radiographs were obtained in 115 pa...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000795
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVE:To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT). METHODS:A scout dose (60 mg) was injected into the hepatic artery of five pigs and S...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1613-1
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVE:To update quality standards for CT colonography based on consensus among opinion leaders within the European Society of Gastrointestinal and Abdominal Radiology (ESGAR). MATERIAL AND METHODS:A multinational European panel of nine members of the ESGAR CT colonography Working Group (representing six EU countri...
journal_title:European radiology
pub_type: 杂志文章,实务指引
doi:10.1007/s00330-012-2632-x
更新日期:2013-03-01 00:00:00
abstract:OBJECTIVE:To determine the diagnostic value of non-contrast-enhanced, 3D-high-resolution, ECG-gated, multi-step MR angiography (non-ceMRA) of the lower extremities using a modified turbo-spin-echo technique in comparison to 1.0-molar contrast-enhanced MR angiography (ceMRA) in patients with suspected peripheral vascula...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1932-2
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVE:To investigate the detection rate of pulmonary nodules in ultralow-dose CT acquisitions. MATERIALS AND METHODS:In this lung phantom study, 232 nodules (115 solid, 117 ground-glass) of different sizes were randomly distributed in a lung phantom in 60 different arrangements. Every arrangement was acquired once...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-4192-3
更新日期:2016-10-01 00:00:00
abstract::The increasing availability of high-field (3 T) MR scanners requires adapting and optimizing clinical imaging protocols to exploit the theoretically higher signal-to-noise ratio (SNR) of the higher field strength. Our aim was to establish reliable and stable protocols meeting the clinical demands for imaging the neuro...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1984-7
更新日期:2003-09-01 00:00:00
abstract::Earlier studies have shown that single-energy quantitative computed tomography (SEQCT) is a reliable method for bone mineral density (BMD) measurements in thoracic and lumbar vertebrae. Moreover, SEQCT has proved to be a useful parameter in the selection of appropriate implants in cervical spondylodesis. The aim of th...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050312
更新日期:1997-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the changes in mammographic density after tamoxifen discontinuation in premenopausal women with oestrogen receptor-positive breast cancers and the underlying factors METHODS: A total of 213 consecutive premenopausal women with breast cancer who received tamoxifen treatment after curative surgery ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5293-y
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVES:To compare the diagnostic accuracy and sensitivity of Gd-EOB-DTPA MRI and diffusion-weighted (DWI) imaging alone and in combination for detecting colorectal liver metastases in patients who had undergone preoperative chemotherapy. METHODS:Thirty-two consecutive patients with a total of 166 liver lesions wer...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2658-0
更新日期:2013-03-01 00:00:00
abstract::Erdheim-Chester (EC) disease belongs to the group of lipoid granulomatosis. Symmetric sclerosis of the meta- and diaphysis of long tubular bones are pathognomonic radiologic changes. Additionally, other skeletal segments can be affected. Extraskeletal manifestations can occur in almost all organs; lungs, pericardium, ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300050647
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVES:To evaluate a new approach for reconstructing angiographic images by application of wavelet transforms on CT perfusion data. METHODS:Fifteen consecutive patients with suspected stroke were examined with a multi-detector CT acquiring 32 dynamic phases (∆t = 1.5s) of 99 slices (total slab thickness 99mm) at 8...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3651-1
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVES:To retrospectively evaluate the feasibility of CT assessment-based direct surgical resection of part-solid nodules (PSNs) with solid components > 5 mm without preoperative percutaneous transthoracic needle biopsies (PTNBs). METHODS:From January 2009-December 2014, 85 PSNs with solid components > 5 mm on CT ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-4917-6
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVES:To investigate the repeatability, reproducibility, and staging and monitoring of the performance of native T1 mapping for noninvasively assessing liver fibrosis in comparison with acoustic radiation force impulse (ARFI) elastography. METHODS:The repeatability and reproducibility were explored in 8 male Spra...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06335-0
更新日期:2020-01-01 00:00:00
abstract::Accessory ossicles and sesamoid bones are frequent findings in routine radiographs of the ankle and foot. They are commonly considered fortuitous and unrelated to the patient's complaint; however, they may eventually cause painful syndromes or degenerative changes in response to overuse and trauma. They may also suffe...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-2011-8
更新日期:2003-12-01 00:00:00
abstract:OBJECTIVES:Opportunistic screening for osteoporosis using computed tomography (CT) examinations that happen to visualise the spine can be used to identify patients with osteoporosis. We sought to verify the diagnostic performance of vertebral Hounsfield unit (HU) measurements on routine CT examinations for diagnosing o...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3584-0
更新日期:2015-07-01 00:00:00
abstract::The aim of this preliminary study was to retrospectively evaluate the usefulness of high b-value diffusion-weighted MR imaging (DWI) in the detection of gallbladder carcinoma. Fifteen patients with gallbladder carcinoma and 14 other patients were included in this study. All patients and subjects underwent DWI, and ima...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1322-9
更新日期:2009-07-01 00:00:00
abstract::Although the predominant form of tuberculosis is pulmonary disease, an increasing number of cases with extra-pulmonary involvement have been reported. The diagnosis of extra-pulmonary tuberculosis is often difficult because of its protean clinical manifestations and non-specific laboratory findings. Abdominal lymph no...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-1943-3
更新日期:2004-04-01 00:00:00
abstract::The RETAIN project (Radiological Examinations Transfer on an ATM Integrated Network) has aimed at testing videoconferencing and DICOM image transfers to get advice about difficult radiological cases over an asynchronous transfer mode (ATM)-based network, which affords a more comfortable interface than narrow-band netw...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050029
更新日期:2000-01-01 00:00:00
abstract::In the absence of reliable supplies of X-ray film, direct fluoroscopy is still extensively used in Albania, with chest radiology a particularly common application. This paper aims to quantify both patient skin dose and the risk-related quantity effective dose for direct fluoroscopy units based in seven different Alban...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000462
更新日期:2001-01-01 00:00:00
abstract::The objective of this study was to optimize ankle joint MR imaging in volunteers at 1.5 Tesla (T) and 3.0 T, and to compare these optimized sequences concerning image quality and performance in assessing cartilage, ligament and tendon pathology in fresh human cadaver specimens. Initially our clinical ankle protocol co...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0446-4
更新日期:2007-06-01 00:00:00
abstract::Almost the entire world, not only China, is currently experiencing the outbreak of a novel coronavirus that causes respiratory disease, severe pneumonia, and even death. The outbreak began in Wuhan, China, in December of 2019 and is currently still ongoing. This novel coronavirus is highly contagious and has resulted ...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-020-06827-4
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVES:To investigate pulmonary vasculature opacification during CTPA using an optimised patient-specific protocol for administering contrast agent. METHODS:CTPA was performed on 200 patients with suspected PE. Patients were assigned to two protocol groups: protocol A, fixed 80 ml contrast agent; protocol B used a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-013-2919-6
更新日期:2013-11-01 00:00:00
abstract:OBJECTIVES:This study aimed to evaluate automated breast ultrasound (ABUS) compared to hand-held traditional ultrasound (HHUS) in the visualisation and BIRADS characterisation of breast lesions. MATERIALS AND METHODS:From January 2016 to January 2017, 1,886 women with breast density category C or D (aged 48.6±10.8 yea...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-017-5011-9
更新日期:2018-02-01 00:00:00
abstract:OBJECTIVES:To compare speed of sound (SoS) ultrasound (US) of the calves with Dixon magnetic resonance imaging (MRI) for fat content quantification. MATERIALS AND METHODS:The study was approved by the local ethics committee. Fifty calf muscles of 35 women (age range 22-81 years) prospectively underwent an US and subse...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06885-8
更新日期:2020-10-01 00:00:00
abstract:OBJECTIVES:We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. METHODS:Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 20...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4216-7
更新日期:2016-10-01 00:00:00
abstract::Our objective was to determine the value of the Ottawa knee rules when applied by users with different levels of clinical training. We used a prospective patient survey by the medical students and surgery residents of a European university trauma centre. The study group consisted of 261 eligible patients who presented...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-001-1198-9
更新日期:2002-05-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of diffusion-weighted MRI (DWI) in addition to T2-weighted (T2W) MRI for nodal restaging after chemoradiation in rectal cancer. METHODS:Thirty patients underwent chemoradiation followed by MRI (1.5 T) and surgery. Imaging consisted of T2W-MRI and DWI (b0, 500, 1000). On T2W-MRI, ...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-010-1937-x
更新日期:2011-02-01 00:00:00
abstract::Because of the increasing incidence of primary central nervous system lymphoma (PCNSL), it is essential to recognize this disease in order to start appropriate treatment. We present the characteristic CT and MRI features of this tumour. The findings of 32 CT and 31 MR of 37 immunocompetent patients with biopsy-proved ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300101037
更新日期:2002-02-01 00:00:00
abstract::Our objective was to evaluate, in a routine clinical setting, the role of spiral CT as a second procedure in patients with clinically suspected pulmonary embolism (PE) and abnormal perfusion scan. We prospectively studied the role of spiral CT in 279 patients suspected of PE. All patients started their diagnostic algo...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-002-1709-3
更新日期:2003-07-01 00:00:00