Abstract:
PURPOSE:To determine the computed tomographic (CT) detector configuration, patient size, and image noise limitations that will result in acceptable image quality of 80-kV images obtained at abdominal dual-energy CT. MATERIALS AND METHODS:The Institutional Review Board approved this HIPAA-compliant retrospective study from archival material from patients consenting to the use of medical records for research purposes. A retrospective review of contrast material-enhanced abdominal dual-energy CT scans in 116 consecutive patients was performed. Three gastrointestinal radiologists noted detector configuration and graded image quality and artifacts at specified levels-midliver, midpancreas, midkidneys, and terminal ileum-by using two five-point scales. In addition, an organ-specific enhancement-to-noise ratio and background noise were measured in each patient. Patient size was measured by using the longest linear dimension at the level of interest, weight, lean body weight, body mass index, and body surface area. Detector configuration, patient sizes, and image noise levels that resulted in unacceptable image quality and artifact rankings (score of 4 or higher) were determined by using multivariate logistic regression. RESULTS:A 14 × 1.2-mm detector configuration resulted in fewer images with unacceptable quality than did the 64 × 0.6-mm configuration at all anatomic levels (P = .004, .01, and .02 for liver, pancreas, and kidneys, respectively). Image acceptability for the kidneys and ileum was significantly greater than that for the liver for all readers and detector configurations (P < .001). For the 14 × 1.2-mm detector configuration, patient longest linear dimensions yielding acceptable image quality across readers ranged from 34.9 to 35.8 cm at the four anatomic levels. CONCLUSION:An 80-kV abdominal CT can be performed with appropriate diagnostic quality in a substantial percentage of the population, but it is not recommended beyond the described patient size for each anatomic level. The 14 × 1.2-mm detector configuration should be preferred.
journal_name
Radiologyjournal_title
Radiologyauthors
Guimarães LS,Fletcher JG,Harmsen WS,Yu L,Siddiki H,Melton Z,Huprich JE,Hough D,Hartman R,McCollough CHdoi
10.1148/radiol.10092016subject
Has Abstractpub_date
2010-12-01 00:00:00pages
732-42issue
3eissn
0033-8419issn
1527-1315pii
radiol.10092016journal_volume
257pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Between the portal vein and the inferior vena cava lies a small space that may be occupied by multiple anatomic structures including the caudate and papillary processes of the caudate lobe of the liver, portacaval lymph nodes, replaced or accessory right hepatic arteries, posterosuperior pancreaticoduodenal vessels, t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.2.4011910
更新日期:1985-08-01 00:00:00
abstract::Clinically useful quantities of 52Fe have been prepared at the Brookhaven Linac Isotope Producer (BLIP) by bombarding manganese or nickel targets with medium energy protons. After chemical separation, 52Fe is loaded onto a generator column from which carrier-free 52Mn is eluted. The 52mMn generator is potentially usef...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/132.2.475
更新日期:1979-08-01 00:00:00
abstract::Corticosteroids and local anesthetics are some of the most commonly administered medications in radiology departments. These medications have marked variability in their formulations, which may increase their adverse event profile for specific procedures. In particular, certain corticosteroid preparations are associat...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2523081929
更新日期:2009-09-01 00:00:00
abstract::In 41 patients with clinical evidence of pancreatic islet cell tumors, CT detected 21 of 27 tumors that were proved at surgery (sensitivity 78%) and correctly excluded the diagnosis in 14 of 14 patients with no evidence of tumor at long-term follow-up. Using rapid sequence CT scanning and bolus contrast material infus...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.150.2.6318260
更新日期:1984-02-01 00:00:00
abstract:PURPOSE:To determine if water diffusivity within lymphomas and high-grade astrocytomas correlates with cellularity. MATERIALS AND METHODS:Echo-planar diffusion-weighted magnetic resonance (MR) images obtained in 11 patients with brain lymphomas (19 lesions) and in 17 patients with astrocytomas (19 lesions) were retros...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2241010637
更新日期:2002-07-01 00:00:00
abstract:PURPOSE:To determine if prominent vascularity and low pulsatility index (PI) and resistive index (RI) in endometrial arteries help differentiate carcinoma from benign lesions. MATERIALS AND METHODS:Forty-five postmenopausal women with at least 8-mm-thick endometrium at endovaginal ultrasound (US) underwent color duple...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.195.3.7753990
更新日期:1995-06-01 00:00:00
abstract::We describe a modification of a tracheostomy tube that allows treatment of carcinoma recurrence in the tracheal stoma using intracavitary radiation therapy. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.1.3952320
更新日期:1986-04-01 00:00:00
abstract::The authors present a gastric mucosal biopsy technique with use of a nasogastric catheter and biopsy forceps after double-contrast upper gastrointestinal fluoroscopy in patients with clinical symptoms of dyspepsia. In 51 patients (18 men and 33 women, aged 27-73 years [mean, 46 years]), 136 aggregates (specimens compo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.1.8134590
更新日期:1994-04-01 00:00:00
abstract::During a 17-year period, 33 injuries produced radiographic abnormalities in 26 members of a professional football team. Sites of injury were correlated with playing position and protective equipment worn at the time of injury. Fractures of multiple transverse processes of the lumbar spine are reported in offensive hal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/117.1.33
更新日期:1975-10-01 00:00:00
abstract:PURPOSE:To assess prospectively the concordance of enhancement patterns of focal liver masses on contrast material-enhanced ultrasonographic (US) scans with patterns on contrast-enhanced computed tomographic (CT) scans or magnetic resonance (MR) images. MATERIALS AND METHODS:This study was approved by the institutiona...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2421051006
更新日期:2007-01-01 00:00:00
abstract::Fifty-five liver metastases in 21 patients were treated with interstitial laser photocoagulation (ILP). Tumors were irradiated with a neodymium yttrium aluminum garnet laser via optical fibers passed through 19-gauge needles inserted under ultrasound (US) guidance. Heating of the tumor was evident at real-time US as a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.187.2.8475270
更新日期:1993-05-01 00:00:00
abstract::Purpose To evaluate the performance of the 2010 Society of Radiologists in Ultrasound (SRU) consensus guidelines in the risk stratification of symptomatic and asymptomatic adnexal cysts. Materials and Methods An institutional review board-approved retrospective review was performed, including adnexal cysts detected wi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161625
更新日期:2017-11-01 00:00:00
abstract::The pulmonary manifestations of blastomycosis were observed in 51 patients and correlated with their location in the lungs and the clinical appearance of the patient. Blastomycosis is primarily an airbone infection that occurs in both acute and chronic forms and follows a specific pathway within the lungs. It must be ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.1.25
更新日期:1976-07-01 00:00:00
abstract::To prevent platelet aggregation following percutaneous transluminal angioplasty (PTA), cyclooxygenase inhibitors such as acetylsalicylic acid (ASA) and indomethacin are recommended. However, ASA blocks both the proaggregating effects of thromboxane (TXA2) and the antiaggregating and vasodilating effects of prostacycli...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.149.3.6227930
更新日期:1983-12-01 00:00:00
abstract::Pilomatrixomas (calcifying epitheliomas of Malherbe) are benign soft-tissue tumors that occur in the dermis or subcutaneous tissues; about 40% are found in children under 10 years of age. More than 80% have microscopic calcification and/or ossification. Although the incidence of radiographically visible calcification ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/123.1.151
更新日期:1977-04-01 00:00:00
abstract::Cardiac masses are usually first detected at echocardiography. In their further evaluation, cardiac magnetic resonance (MR) imaging has become a highly valuable technique. MR imaging offers incremental value owing to its larger field of view, superior tissue contrast, versatility in image planes, and unique ability to...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.13121239
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:To assess the feasibility of automatic needle-guide tracking by using a real-time phase-only cross correlation ( POCC phase-only cross correlation ) algorithm-based sequence for transrectal 3-T in-bore magnetic resonance (MR)-guided prostate biopsies. MATERIALS AND METHODS:This study was approved by the ethics...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132067
更新日期:2014-12-01 00:00:00
abstract::Background Several changes have been made to the revised 2017 international consensus guidelines for management of pancreatic intraductal papillary mucinous neoplasms (IPMNs). However, the diagnostic performance is yet to be verified. Purpose To evaluate the revised guidelines for predicting malignant potential of pan...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019190144
更新日期:2019-10-01 00:00:00
abstract::An 8-F guiding catheter has been developed for use with coaxial angioplasty balloon catheters in angioplasty of the femoral artery from the contralateral approach when antegrade puncture of the ipsilateral femoral artery is not possible. The catheter may be used for angioplasty of the femoral artery bifurcation and th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.177.2.2145610
更新日期:1990-11-01 00:00:00
abstract:PURPOSE:To determine the effects of the Valsalva maneuver on intraluminal colon pressure during air enema studies. MATERIALS AND METHODS:Air enema studies were performed in four adult volunteers, and intraluminal colon pressure measurements were recorded with a high-speed electronic strip chart and aneroid gauge metho...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.202.3.9051040
更新日期:1997-03-01 00:00:00
abstract:PURPOSE:To evaluate gadolinium-enhanced three-dimensional magnetic resonance (MR) angiography for thoracic aortic disease and to compare this technique with conventional thoracic MR imaging. MATERIALS AND METHODS:One hundred eight consecutive patients underwent 122 thoracic MR examinations, including conventional MR i...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.202.1.8988210
更新日期:1997-01-01 00:00:00
abstract::A new software program provides the real-time display of high-resolution computed tomographic reformation in the axial, coronal, sagittal, or oblique views. The advantages of this new technique over the standard multiplanar format include (a) larger image display format, (b) reconstruction of entire dataset for each o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.170.1.2909110
更新日期:1989-01-01 00:00:00
abstract::Purpose To evaluate the associations among mathematical modeling with the use of magnetic resonance (MR) imaging-based texture features and deep myometrial invasion (DMI), lymphovascular space invasion (LVSI), and histologic high-grade endometrial carcinoma. Materials and Methods Institutional review board approval wa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017161950
更新日期:2017-09-01 00:00:00
abstract::Eight patients with liver disease and seriously abnormal blood coagulation underwent biopsy of the liver performed through a percutaneously introduced sheath, followed by embolization of the biopsy track with steel coils. In all cases the biopsy procedure produced profuse bleeding through the sheath. However, the blee...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.1.3420270
更新日期:1988-10-01 00:00:00
abstract::Four nodules, visualized with 99mTc pertechnetate at 20-60 min., were not visualized with either 123I or 131I at 2-4 hours. Each nodule was demonstrated to have autonomy of function in excess of surrounding normal tissue when imaged with radioiodine after TSH suppression. Rapid turnover of an iodine moiety would seem ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/119.3.737
更新日期:1976-06-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of 64-section multidetector computed tomography (CT) for the assessment of perfusion defects (PDs), regional wall motion (RWM), and global left ventricular (LV) function. MATERIALS AND METHODS:All myocardial infarction (MI) patients signed informed consent. The IRB approved the study a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2482071478
更新日期:2008-08-01 00:00:00
abstract:PURPOSE:To describe thin-section pulmonary computed tomographic (CT) features in asymptomatic elderly individuals. MATERIALS AND METHODS:Institutional review board approval was given, and informed consent was obtained. Two study groups (older group, over 75 years of age; younger group, under 55 years) were prospective...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2512081242
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:To prospectively evaluate the feasibility and clinical value of computed tomography (CT)-guided iodine 125 ((125)I) brachytherapy to treat bilateral lung recurrences from colorectal carcinoma. MATERIALS AND METHODS:This study was approved by Sun Yat-sen University Cancer Center Institutional Review Board and a...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.2015150641
更新日期:2016-03-01 00:00:00
abstract::We performed 32 overpressure radionuclide cisternography (ORNC) studies to examine 26 patients who were clinically suspected of having cerebrospinal fluid (CSF) fistula with rhinorrhea. Fifteen (47%) of these cisternography studies were positive, and the site of the leak was identified. No leak could be demonstrated i...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.3.3881800
更新日期:1985-03-01 00:00:00
abstract::In 24 CT studies in children with brain stem gliomas, the CT appearance was seen to vary with the tumor's physical characteristics. Infiltrative tumors produce diffuse enlargement of the brain stem; they are isodense with brain parenchyma or of decreased density and may show partial enhancement. Some gliomas grow foca...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.1.7350640
更新日期:1980-01-01 00:00:00