Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.

Abstract:

PURPOSE:To evaluate gadolinium-enhanced three-dimensional magnetic resonance (MR) angiography for thoracic aortic disease and to compare this technique with conventional thoracic MR imaging. MATERIALS AND METHODS:One hundred eight consecutive patients underwent 122 thoracic MR examinations, including conventional MR imaging followed by enhanced three-dimensional MR angiography. A gradient-echo sequence was used at 1.5 T (116 examinations) and 1.0 T (6 examinations) during infusion of 0.2 mmol/kg gadopentetate dimeglumine. Two independent readers (A and B), with varied experience in thoracic MR angiography, retrospectively evaluated the images for presence of aortic dissection, aneurysm, arch vessel disease, and protruding atheroma. Correlation with findings of surgery or other imaging modalities was available in 98 cases. RESULTS:Enhanced MR angiography was sensitive (92%-96%) and specific (100%) for acute and chronic aortic dissection (n = 26) and was as useful as conventional MR imaging in the diagnosis of aneurysm (n = 43) and arch vessel disease (n = 7). One of two intramural hematomas were overlooked at MR angiography by reader A, and both were overlooked by reader B. CONCLUSION:Enhanced three-dimensional MR angiography is a rapid and accurate imaging modality in diagnosis of thoracic aortic disease but is insensitive to intramural hematoma.

journal_name

Radiology

journal_title

Radiology

authors

Krinsky GA,Rofsky NM,DeCorato DR,Weinreb JC,Earls JP,Flyer MA,Galloway AC,Colvin SB

doi

10.1148/radiology.202.1.8988210

subject

Has Abstract

pub_date

1997-01-01 00:00:00

pages

183-93

issue

1

eissn

0033-8419

issn

1527-1315

journal_volume

202

pub_type

杂志文章
  • Determination of regional ejection fraction in patients with myocardial infarction by using merged late gadolinium enhancement and cine MR: feasibility study.

    abstract:PURPOSE:To quantify regional ejection fraction (EF) in patients with myocardial infarction (MI) by using merged late gadolinium enhancement (LGE) and cine magnetic resonance (MR) imaging, and compare this method with the standardized 17-segment American Heart Association approach. MATERIALS AND METHODS:After instituti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2493080340

    authors: Masci PG,Dymarkowski S,Rademakers FE,Bogaert J

    更新日期:2009-01-01 00:00:00

  • Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: initial experience.

    abstract::The purpose of this study was to develop an automated scheme to facilitate detection of localized ground-glass opacity (GGO) in the lung at computed tomography (CT). Institutional review board approval and informed consent were not required. Two radiologists reviewed CT images from 14 patients (five men, nine women) w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2372041461

    authors: Kim KG,Goo JM,Kim JH,Lee HJ,Min BG,Bae KT,Im JG

    更新日期:2005-11-01 00:00:00

  • MR imaging evaluation of endometrial carcinoma: results of an NCI cooperative study.

    abstract::A prospective study to assess the usefulness of magnetic resonance (MR) imaging in the evaluation of endometrial carcinoma was undertaken by five institutions under the auspices of the National Cancer Institute. Six different MR imagers were used, ranging in magnetic field strength from 0.15 T to 1.5 T. For each unit,...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.3.2028000

    authors: Hricak H,Rubinstein LV,Gherman GM,Karstaedt N

    更新日期:1991-06-01 00:00:00

  • Liver metastases from colorectal carcinoma: detection with continuous CT angiography.

    abstract::A diagnostic approach to assess liver metastases from colorectal carcinoma was prospectively evaluated in 30 patients with and without metastases on the basis of findings at conventional computed tomography (CT). With the technique, termed continuous CT angiography (CCTA), CT data were continuously sampled for 24 seco...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.1.1523300

    authors: Oudkerk M,van Ooijen B,Mali SP,Tjiam SL,Schmitz PI,Wiggers T

    更新日期:1992-10-01 00:00:00

  • Pneumonia caused by Pittsburgh pneumonia agent: radiologic manifestations.

    abstract::Using an objective scoring system, chest radiographs were reviewed in 23 cases of pneumonia due to the Pittsburgh pneumonia agent (PPA, Tatlockia micdadei, Legionella micdadei), including six cases of pneumonia with simultaneous isolation of PPA and L pneumophila (Legionnaires' disease). Infiltrates were typically seg...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.3.6695060

    authors: Muder RR,Reddy SC,Yu VL,Kroboth FJ

    更新日期:1984-03-01 00:00:00

  • Angiographic diagnosis of fourth ventricle tumors.

    abstract::Twelve primary fourth ventricle tumors and 22 medulloblastomas occupying mainly the fourth ventricle were analyzed, with emphasis on the differential diagnosis, vascularity, and some unusual findings. Though both types of tumor often have identical manifestations, the correct diagnosis can be made in most cases by car...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/128.2.393

    authors: Numaguchi Y,Kishikawa T,Fukui M,Komaki S,Russell WJ,Ikeda J,Okudera T,Matsuura K,Kitamura K

    更新日期:1978-08-01 00:00:00

  • Corrosive esophageal stricture: safety and effectiveness of balloon dilation.

    abstract::The safety and long-term effectiveness of fluoroscopically guided balloon dilation for corrosive esophageal stricture was evaluated in 22 patients with a follow-up period of more than 1 year (range, 13-52 months). The average interval between corrosive agent ingestion and initial balloon dilation was 18 years (range, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.184.2.1620830

    authors: Song HY,Han YM,Kim HN,Kim CS,Choi KC

    更新日期:1992-08-01 00:00:00

  • Aggressive neuroblastoma simulating Wilms tumor.

    abstract::Solid intrarenal neoplasms in children are usually Wilms tumors. Occasionally, however, a neuroblastoma appears to be intrarenal. In six cases where this phenomenon was observed, the histologic findings of each tumor were identical: undifferentiated neuroblastoma. In each case the child's condition rapidly and progres...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.1.2827230

    authors: Rosenfield NS,Leonidas JC,Barwick KW

    更新日期:1988-01-01 00:00:00

  • Subtraction radiography: techniques and limitations.

    abstract::Subtraction radiography permits the use of 7-10 times less contrast material than is required without subtraction techniques. The first-order, second-order, and composite mask techniques are described and evaluated. While the second-order technique gives more complete cancellation of common structures, the more common...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.1.65

    authors: Ort MG,Gregg EC,Kaufman B

    更新日期:1977-07-01 00:00:00

  • Autocorrection in MR imaging: adaptive motion correction without navigator echoes.

    abstract::A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.3.r00jn19904

    authors: Manduca A,McGee KP,Welch EB,Felmlee JP,Grimm RC,Ehman RL

    更新日期:2000-06-01 00:00:00

  • Performance of Screening Breast MRI across Women with Different Elevated Breast Cancer Risk Indications.

    abstract::Background Screening breast MRI is recommended for women with BRCA mutation or a history of chest radiation, but guidelines are equivocal for MRI screening of women with a personal history of breast cancer or high-risk lesion. Purpose To evaluate screening breast MRI performance across women with different elevated br...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019181136

    authors: Sippo DA,Burk KS,Mercaldo SF,Rutledge GM,Edmonds C,Guan Z,Hughes KS,Lehman CD

    更新日期:2019-07-01 00:00:00

  • New method for fast MR imaging of the knee.

    abstract::Thirty-five patients with suspected internal derangements of the knee were examined with conventional two-dimensional (2D) spin-echo magnetic resonance (MR) imaging techniques and a new rapid three-dimensional (3D) method called 3D FASTER (field echo acquisition with a short repetition time and echo reduction). A 9-mi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.3.2813780

    authors: Harms SE,Flamig DP,Fisher CF,Fulmer JM

    更新日期:1989-12-01 00:00:00

  • Portal-systemic encephalopathy: presence of basal ganglia lesions with high signal intensity on MR images.

    abstract::Sixteen patients with cirrhosis of the liver underwent cranial magnetic resonance (MR) imaging and transarterial portography to evaluate the relationship between basal ganglia lesions and portal-systemic collateral vessels. No neuropsychiatric disturbance was observed in any of the patients at the time of the MR exami...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014310

    authors: Inoue E,Hori S,Narumi Y,Fujita M,Kuriyama K,Kadota T,Kuroda C

    更新日期:1991-05-01 00:00:00

  • A comparison of methods for assessing patient body burden following 131I therapy for thyroid cancer.

    abstract::The effectiveness of three methods of assessing the patient body burden following 131I therapy was compared: (a) urine assay, (b) external exposure rate measurements, and (c) predictions based on a pretherapy diagnostic work-up. The urine assay method exhibited the greatest potential for error and personnel risk. The ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.3.7444070

    authors: Thomas SR,Maxon HR,Fritz KM,Kereiakes JG,Connell WD

    更新日期:1980-12-01 00:00:00

  • The juxtaphrenic peak in upper lobe collapse.

    abstract::Steeple-shaped shadows adjacent to the diaphragm are common in upper lobe collapse due to a variety of causes. They call attention to upper lobe collapse and should not be considered indicative of intrinsic lower lobe abnormality. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355230

    authors: Kattan KR,Eyler WR,Felson B

    更新日期:1980-03-01 00:00:00

  • Computed transaxial imaging using single gamma emitters.

    abstract::Emission computed tomography (ECT) studies were performed on test objects and dogs. Conjugate views were obtained for 60 to 120 projections equispaced around 360 degrees by rotation of the subjects in front of a gamma camera. A convolution reconstruction algorithm in which gamma ray attenuation corrections are include...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.1.187

    authors: Gustafson DE,Berggren MJ,Singh M,Dewanjee MK

    更新日期:1978-10-01 00:00:00

  • Gallbladder disease: appearance of associated transient increased attenuation in the liver at biphasic, contrast-enhanced dynamic CT.

    abstract:PURPOSE:To evaluate the frequency, location, and appearance of transient increased attenuation in the liver during arterial-phase helical or incremental computed tomography (CT) in patients with gallbladder disease without hepatic extension. MATERIALS AND METHODS:Findings in dynamic CT examinations in 31 patients with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.3.9280250

    authors: Ito K,Awaya H,Mitchell DG,Honjo K,Fujita T,Uchisako H,Moritani K,Nomura S,Higuchi M,Kada T,Matsumoto T,Matsunaga N

    更新日期:1997-09-01 00:00:00

  • Early familial dilated cardiomyopathy: identification with determination of disease state parameter from cine MR image data.

    abstract:PURPOSE:To characterize early changes in cardiac anatomy and function for lamin A/C gene (LMNA) mutation carriers by using magnetic resonance (MR) imaging and to develop tools to analyze and visualize the findings. MATERIALS AND METHODS:The ethical review board of the institution approved the study, and informed writt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2491071584

    authors: Koikkalainen JR,Antila M,Lötjönen JM,Heliö T,Lauerma K,Kivistö SM,Sipola P,Kaartinen MA,Kärkkäinen ST,Reissell E,Kuusisto J,Laakso M,Oresic M,Nieminen MS,Peuhkurinen KJ

    更新日期:2008-10-01 00:00:00

  • Practical and technical considerations in establishing an intraoperative radiation therapy program in the community practice.

    abstract::The Radiation Oncology Center in Sacramento, California, has developed a procedure for establishing an intraoperative radiation therapy facility in a community practice. The logistics pertaining to personnel, equipment, physical measurements, and quality assurance are presented. Particular emphasis is given to the mos...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380970

    authors: Wolkov HB,Chenery SG,Asche DR,McPeek EC,Hanks GE,Holmes TW

    更新日期:1988-07-01 00:00:00

  • Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

    abstract::Spiral volumetric computed tomography (CT) with single breath-hold technique was compared with conventional sequential CT in 39 patients. The spiral CT protocol consisted of a 10 mm/sec table feed during a 24-second breath hold at 145 mA, with reconstruction of images at 10-mm intervals; one (n = 21) or two (n = 18) s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.187.2.8475300

    authors: Remy-Jardin M,Remy J,Giraud F,Marquette CH

    更新日期:1993-05-01 00:00:00

  • Retrievable vena caval filter percutaneously introduced.

    abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001390

    authors: Lund G,Rysavy J,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Ultrasonography in the staging of endometrial adenocarcinoma.

    abstract::Adenocarcinoma of the endometrium commonly presents at an early stage and is readily diagnosed by dilatation and curettage. Ultrasound has not bee accurate in differentiating this malignant neoplasm from benign causes of uterine enlargement such as leiomyoma. In this study, the sonographic findings in 21 patients with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.3.7280250

    authors: Requard CK,Wicks JD,Mettler FA Jr

    更新日期:1981-09-01 00:00:00

  • Ethmoid sinus disease: CT evaluation in 400 cases. Part II. Postoperative findings.

    abstract::Clinical, pathologic, and computed tomographic (CT) findings were reviewed in 400 patients with ethmoid sinus disease, including 272 who had undergone surgery. The postoperative appearance of ethmoid sinuses on CT scans is a highly neglected subject in radiologic literature. The unique ethmoid anatomy permits a variet...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3704140

    authors: Som PM,Lawson W,Biller HF,Lanzieri CF

    更新日期:1986-06-01 00:00:00

  • Nonionic versus ionic contrast media in intravenous urography: clinical trial in 1,000 consecutive patients.

    abstract::A double-blind clinical trial was performed in 1,000 consecutive patients to compare the safety and efficacy of intravenously administered nonionic (iohexol) and ionic (metrizoate) urographic contrast media. The patients ranged in age from 10 to 80 years. The incidence of mild to moderate adverse effects was 7.7% with...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.167.3.3283830

    authors: Jacobsson BF,Jorulf H,Kalantar MS,Narasimham DL

    更新日期:1988-06-01 00:00:00

  • Heterogeneity in the campomelic syndromes. Long-and short-bone varieties.

    abstract::Analysis of 9 cases of bilateral bent limbs (campomelia) and dwarfism, as well as a review of the literature, indicate that campomelic syndrome appears to be a well-defined distinct disorder which the authors call long-limbed campomelic syndrome. Other neonates with congenital bent-limbed dwarfism can be classified as...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.641

    authors: Khajavi A,Lachman R,Rimoin D,Schimke RN,Dorst J,Handmaker S,Ebbin A,Perreault G

    更新日期:1976-09-01 00:00:00

  • Reperfusion and irreversible myocardial injury: identification with a nonionic MR imaging contrast medium.

    abstract::The potential of a new nonionic gadolinium complex--gadodiamide injection--to (a) allow distinction between reperfused and occlusive infarction and (b) enable differentiation between reperfused reversible and irreversible myocardial injury was investigated. Three groups of rats were used: 10 with reversibly reperfused...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.182.3.1535880

    authors: Saeed M,Wendland MF,Takehara Y,Masui T,Higgins CB

    更新日期:1992-03-01 00:00:00

  • A comparison of saddle-shaped and solenoidal coils for magnetic resonance imaging.

    abstract::Differences in magnetic resonance (MR) imaging signal-to-noise (S/N) performance between saddle-shaped and solenoidal coils have been postulated. Each coil shape is tied to a particular magnetic field configuration, so that they are not typically interchangeable except in special situations. The solenoidal coil is pre...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3964940

    authors: Arakawa M,Crooks LE,McCarten B,Hoenninger JC,Watts JC,Kaufman L

    更新日期:1985-01-01 00:00:00

  • Anatomic variations in the first extensor compartment of the wrist: accuracy of US.

    abstract:PURPOSE:To evaluate the accuracy of ultrasonography (US) in determining the anatomic variations in the first extensor compartment of the wrist. MATERIALS AND METHODS:Approval from the anatomic donations department was obtained. The first extensor compartment of the wrist of 40 nonembalmed cadaveric forearms (15 male a...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10092265

    authors: Rousset P,Vuillemin-Bodaghi V,Laredo JD,Parlier-Cuau C

    更新日期:2010-11-01 00:00:00

  • Suspected local recurrence after radical prostatectomy: endorectal coil MR imaging.

    abstract:PURPOSE:To evaluate endorectal coil magnetic resonance (MR) imaging in the depiction of local recurrence after radical prostatectomy. MATERIALS AND METHODS:Endorectal MR images were reviewed retrospectively in 82 patients who underwent prostatectomy. The interval between prostatectomy and MR imaging ranged between 0.5...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2312030011

    authors: Sella T,Schwartz LH,Swindle PW,Onyebuchi CN,Scardino PT,Scher HI,Hricak H

    更新日期:2004-05-01 00:00:00

  • Case 224: Cardiac Involvement in Erdheim-Chester Disease.

    abstract::History A 61-year-old man with no relevant medical history was admitted to the emergency department with symptoms of congestive heart failure and a 1-week history of chest pain, progressive dyspnea, abdominal swelling, bipedal edema, and anorexia. Laboratory test results, including complete blood count and electrolyte...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015131751

    authors: de Miguel Criado J,Aguilera Del Hoyo LF,García Del Salto L,Cueva Pérez E,Casado Cerrada J,Nieto Llanos S,Porro Fernández JC,Fraga Rivas P

    更新日期:2015-12-01 00:00:00