Relevance of Artifact Removal and Number of Stimuli for Video Head Impulse Test Examination.

Abstract:

OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifacts. We compared several variations of the dataset. The first variation used only samples without artifacts, the second used all samples (with and without artifacts), and the rest used only samples with each type of artifact. We calculated the relative efficiency (RE) of evaluating an increasingly large number of samples (3 to 19 per side) when compared with the complete sample (20 impulses per side). RESULTS:Overshoot was associated with significantly higher speed (p = 0.005), higher duration (p < 0.001) and lower amplitude of the impulses (p = 0.002), and consequent higher saccades' latency (p = 0.035) and lower amplitude (p = 0.025). Loss of track was associated with lower gain (p = 0.035). Blink was associated with a higher number of saccades (p < 0.001), and wrong way was associated with lower saccade latency (p = 0.012). The coefficient of quartile deviation escalated as the number of artifacts of any type rose, indicating an increment of variability. Overshoot increased the probability of the impulse to lay on the outlier range for gain and peak speed. Blink did so for the number of saccades, and wrong way for the saccade amplitude and speed. RE reached a tolerable level of 1.1 at 7 to 10 impulses for all measurements except the PR score. CONCLUSIONS:Our results suggest the necessity of removing artifacts after collecting VHIT samples to improve the accuracy and precision of results. Ten impulses are sufficient for achieving acceptable RE for all measurements except the PR score.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Trinidad-Ruiz G,Rey-Martinez J,Matiño-Soler E,Batuecas-Caletrio A,Martin-Sanz E,Perez-Fernandez N

doi

10.1097/AUD.0000000000000849

subject

Has Abstract

pub_date

2020-09-01 00:00:00

pages

1397-1406

issue

5

eissn

0196-0202

issn

1538-4667

pii

00003446-202009000-00031

journal_volume

41

pub_type

杂志文章
  • Real ear attenuation at threshold for three audiometric headphone devices: implications for maximum permissible ambient noise level standards.

    abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199202000-00004

    authors: Franks JR,Engel DP 3rd,Themann CL

    更新日期:1992-02-01 00:00:00

  • The contribution of family history to hearing loss in an older population.

    abstract:OBJECTIVES:Although it has been well established that the prevalence of and severity of hearing loss increase with age, the contribution of familial factors to age-related hearing loss cannot be quantified. This is largely because hearing loss in older people has both genetic and environmental contributions. As environ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31817349d6

    authors: McMahon CM,Kifley A,Rochtchina E,Newall P,Mitchell P

    更新日期:2008-08-01 00:00:00

  • Current state of knowledge: outcomes research in children with mild to severe hearing impairment--approaches and methodological considerations.

    abstract::This paper will provide a backdrop to the others in this section on outcomes of children with mild to moderate sensorineural hearing loss. Our objective here is to provide an overview of the research approaches used to study the outcomes of these children to provide guidance for future studies of children with mild to...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e318157f093

    authors: Tomblin B,Hebbeler K

    更新日期:2007-12-01 00:00:00

  • Converting insertion gain to and from headphone coupler responses.

    abstract:OBJECTIVE:The paper aims to show how insertion gain responses can be translated into equivalent headphone responses, and vice versa. DESIGN:The relationship between the response types is theoretically derived by allowing for real ear to coupler differences and for real ear unaided responses. RESULTS:The necessary cor...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199708000-00009

    authors: Dillon H

    更新日期:1997-08-01 00:00:00

  • The additive effect of co-occurring anxiety and depression on health status, quality of life and coping strategies in help-seeking tinnitus sufferers.

    abstract:OBJECTIVE:Evaluating the effect of anxiety and depression on clinical measures of general health, tinnitus-specific quality of life, and coping abilities. DESIGN:Two hundred sixty-five chronic, subjective tinnitus sufferers were divided into four psychological symptom groups according to cut-off scores on anxiety and ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181888f83

    authors: Bartels H,Middel BL,van der Laan BF,Staal MJ,Albers FW

    更新日期:2008-12-01 00:00:00

  • Identifying dead regions in the cochlea: psychophysical tuning curves and tone detection in threshold-equalizing noise.

    abstract:OBJECTIVE:Recent studies indicate that high-frequency amplification may provide little benefit for listeners with moderate-to-severe high-frequency hearing loss, and may even reduce speech recognition. Moore and colleagues have proposed a direct link between this lack of benefit and the presence of regions of nonfuncti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000058148.27540.D9

    authors: Summers V,Molis MR,Müsch H,Walden BE,Surr RK,Cord MT

    更新日期:2003-04-01 00:00:00

  • Distortion product otoacoustic emission test performance for a priori criteria and for multifrequency audiometric standards.

    abstract:OBJECTIVES:1) To describe distortion product otoacoustic emission (DPOAE) test performance when a priori response criteria are applied to a large set of DPOAE data. 2) To describe DPOAE test performance when multifrequency definitions of auditory function are used. 3) To determine DPOAE test performance when a single d...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199908000-00007

    authors: Gorga MP,Neely ST,Dorn PA

    更新日期:1999-08-01 00:00:00

  • Pitfalls in neurotologic diagnosis.

    abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198804000-00007

    authors: Telian SA,Kileny PR

    更新日期:1988-04-01 00:00:00

  • Middle ear dynamic characteristics in patients with otosclerosis.

    abstract:OBJECTIVE:To investigate the middle ear dynamic characteristics in patients with otosclerosis using the sweep frequency impedance meter (SFI test) and conventional tympanometry, and also to evaluate the diagnostic efficiency of the SFI test for otosclerosis. DESIGN:The study was designed to collect a total of 25 (36 e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200204000-00007

    authors: Zhao F,Wada H,Koike T,Ohyama K,Kawase T,Stephens D

    更新日期:2002-04-01 00:00:00

  • Results from a European clinical investigation of the Nucleus multichannel auditory brainstem implant.

    abstract:OBJECTIVE:This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus(R) multichannel auditory brainstem implant. DESIGN:Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects in...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-200206000-00002

    authors: Nevison B,Laszig R,Sollmann WP,Lenarz T,Sterkers O,Ramsden R,Fraysse B,Manrique M,Rask-Andersen H,Garcia-Ibanez E,Colletti V,von Wallenberg E

    更新日期:2002-06-01 00:00:00

  • Comparison of cognitive function in deaf children between before and after cochlear implant.

    abstract:OBJECTIVES:This study was conducted to examine improvements of cognitive abilities after cochlear implantation in deaf children. We also examined the psychosocial factors that predict good outcomes of cochlear implantation. DESIGN:A neuropsychological test battery was administered to 17 deaf children (mean age, 7 yr 2...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318031541b

    authors: Shin MS,Kim SK,Kim SS,Park MH,Kim CS,Oh SH

    更新日期:2007-04-01 00:00:00

  • Clinical findings for a group of infants and young children with auditory neuropathy.

    abstract:OBJECTIVE:To examine the prevalence of auditory neuropathy in a group of infants at risk for hearing impairment and to present an overview of the clinical findings for affected children. DESIGN:Results for 20 subjects who showed repeatable cochlear microphonic potentials in the absence of click-evoked auditory brain s...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199906000-00006

    authors: Rance G,Beer DE,Cone-Wesson B,Shepherd RK,Dowell RC,King AM,Rickards FW,Clark GM

    更新日期:1999-06-01 00:00:00

  • The Emotional Communication in Hearing Questionnaire (EMO-CHeQ): Development and Evaluation.

    abstract:OBJECTIVES:The objectives of this research were to develop and evaluate a self-report questionnaire (the Emotional Communication in Hearing Questionnaire or EMO-CHeQ) designed to assess experiences of hearing and handicap when listening to signals that contain vocal emotion information. DESIGN:Study 1 involved interne...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000611

    authors: Singh G,Liskovoi L,Launer S,Russo F

    更新日期:2019-03-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Objective calibration of bone conductors using otoacoustic emissions.

    abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199910000-00001

    authors: Purcell D,Kunov H,Cleghorn W

    更新日期:1999-10-01 00:00:00

  • The influence of clicks versus short tone bursts on the vestibular evoked myogenic potentials.

    abstract:OBJECTIVE:Vestibular evoked myogenic potential (VEMP) has become a diagnostic tool to evaluate the integrity of sacculo-collic reflex. To obtain a more consistent VEMP response in normal-hearing subjects, we examine whether clicks or short tone bursts are more effective in eliciting VEMP responses. DESIGN:Prospective ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000069225.80220.CB

    authors: Cheng PW,Huang TW,Young YH

    更新日期:2003-06-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Audiologic findings in botulism poisoning.

    abstract::Botulism poisoning results in a presynaptic failure of neuromuscular transmission, and may be expected to impair Eustachian tube and stapedius reflex function. The audiologic findings in five normal-hearing patients with type A botulism poisoning are presented. Results were varied. Two patients demonstrated type B or ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199108000-00007

    authors: Pijl S

    更新日期:1991-08-01 00:00:00

  • Transcutaneous vagus nerve stimulation modulates tinnitus-related beta- and gamma-band activity.

    abstract:OBJECTIVES:The ability of a treatment method to interfere with tinnitus-related neural activity patterns, such as cortical gamma rhythms, has been suggested to indicate its potential in relieving tinnitus. Therapeutic modulation of gamma-band oscillations with vagus nerve stimulation has been recently reported in epile...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000123

    authors: Hyvärinen P,Yrttiaho S,Lehtimäki J,Ilmoniemi RJ,Mäkitie A,Ylikoski J,Mäkelä JP,Aarnisalo AA

    更新日期:2015-05-01 00:00:00

  • Does the 40-Hz auditory steady-state response show the binaural masking level difference?

    abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b61cc8

    authors: Ishida IM,Stapells DR

    更新日期:2009-12-01 00:00:00

  • Effect of electrode impedance on spread of excitation and pitch perception using electrically coupled "dual-electrode" stimulation.

    abstract:OBJECTIVES:In newer-generation Cochlear Ltd. cochlear implants, two adjacent electrodes can be electrically coupled to produce a single contact or "dual electrode" (DE). The goal of the present study was to evaluate whether relatively large impedance differences (>3.0 kOhms) between coupled electrodes affect the excita...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000098

    authors: Hughes ML,Baudhuin JL,Goehring JL

    更新日期:2015-03-01 00:00:00

  • Otodental dysplasia: a five year study.

    abstract::Peripheral auditory sensitivity is documented over a 5-year period on 4 cases with otodental dysplasia. Age of onset is noted for the proband and indicates that onset of this progressive hearing loss occurs as early as the first decade. Findings suggest that the hearing loss plateaus by the fourth decade, resulting in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198103000-00007

    authors: Cook RA,Cox JR,Jorgenson RJ

    更新日期:1981-03-01 00:00:00

  • Parents' preferences for services for children with hearing loss: a conjoint analysis study.

    abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318157676d

    authors: Fitzpatrick E,Coyle DE,Durieux-Smith A,Graham ID,Angus DE,Gaboury I

    更新日期:2007-12-01 00:00:00

  • Behavioral Measures of Listening Effort in School-Age Children: Examining the Effects of Signal-to-Noise Ratio, Hearing Loss, and Amplification.

    abstract:OBJECTIVES:Increased listening effort in school-age children with hearing loss (CHL) could compromise learning and academic achievement. Identifying a sensitive behavioral measure of listening effort for this group could have both clinical and research value. This study examined the effects of signal-to-noise ratio (SN...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000623

    authors: McGarrigle R,Gustafson SJ,Hornsby BWY,Bess FH

    更新日期:2019-03-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • Speech recognition performance of patients with sensorineural hearing loss under unaided and aided conditions using linear and compression hearing AIDS.

    abstract:OBJECTIVES:This study compared speech recognition performance on the Northwestern University Auditory Test No. 6 (NU-6) and the Connected Speech Test (CST) for three hearing aid circuits (peak clipping [PC], compression limiting [CL], and wide dynamic range compression [WDRC]) in adults with symmetrical sensorineural h...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200208000-00003

    authors: Shanks JE,Wilson RH,Larson V,Williams D

    更新日期:2002-08-01 00:00:00

  • Distortion-product and click-evoked otoacoustic emissions of preterm and full-term infants.

    abstract::Full-term and preterm infants were evaluated with click-evoked and distortion-product otoacoustic emissions (CEOEs and DPOEs). The CEOEs and DPOEs recorded from each individual ear were analyzed by calculating the root-mean-square levels within half-octave bands. The fail criterion of the OE tests was that the half-oc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199308000-00005

    authors: Smurzynski J,Jung MD,Lafreniere D,Kim DO,Kamath MV,Rowe JC,Holman MC,Leonard G

    更新日期:1993-08-01 00:00:00

  • Relationship Between Diet, Tinnitus, and Hearing Difficulties.

    abstract:OBJECTIVES:Diet may affect susceptibility of the inner ear to noise and age-related effects that lead to tinnitus and hearing loss. This study used complementary single nutrient and dietary pattern analysis based on statistical grouping of usual dietary intake in a cross-sectional analysis of tinnitus and hearing diffi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000765

    authors: Dawes P,Cruickshanks KJ,Marsden A,Moore DR,Munro KJ

    更新日期:2020-03-01 00:00:00

  • Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise.

    abstract:OBJECTIVE:The purposes of this study were to (a) examine the accuracy of cochlear implant recipients who use different types of devices and signal processing strategies on pitch ranking as a function of size of interval and frequency range and (b) to examine the relations between this pitch perception measure and demog...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3180479318

    authors: Gfeller K,Turner C,Oleson J,Zhang X,Gantz B,Froman R,Olszewski C

    更新日期:2007-06-01 00:00:00

  • List equivalency of the CID everyday sentences (Harris revision) under three signal-to-noise ratios.

    abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198309000-00006

    authors: Rippy JV,Dancer JE,Pittenger JB

    更新日期:1983-09-01 00:00:00