Does the 40-Hz auditory steady-state response show the binaural masking level difference?

Abstract:

:In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) BMLDs for both signal and noise interaural inversions. Results showed clear behavioral BMLD but no 40-Hz ASSR BMLD. However, ASSR amplitudes were significantly smaller in dichotic compared with diotic conditions. Thus, although 40-Hz ASSR thresholds do not reflect the BMLD, the amplitude suppression under dichotic conditions may be a precursor to the subsequent <20-Hz ASSR and behavioral BMLDs.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Ishida IM,Stapells DR

doi

10.1097/AUD.0b013e3181b61cc8

subject

Has Abstract

pub_date

2009-12-01 00:00:00

pages

713-5

issue

6

eissn

0196-0202

issn

1538-4667

journal_volume

30

pub_type

杂志文章
  • Incidence rates of clinically significant tinnitus: 10-year trend from a cohort study in England.

    abstract:OBJECTIVE:To investigate the incidence of tinnitus that burdens the health service in England. DESIGN:This was an observational study of 4.7 million residents of England under 85 years of age who were at risk for developing clinically significant tinnitus (sigT). SigT was defined by a discharge from hospital with a pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000121

    authors: Martinez C,Wallenhorst C,McFerran D,Hall DA

    更新日期:2015-05-01 00:00:00

  • Using multichannel wide-dynamic range compression in severely hearing-impaired listeners: effects on speech recognition and quality.

    abstract:OBJECTIVE:The objective of this study was to compare speech recognition across a sampling of amplification choices available for listeners with severe loss. This includes conventional options (linear with peak clipping and linear with compression limiting) and newer strategies (multichannel wide-dynamic range compressi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200504000-00002

    authors: Souza PE,Jenstad LM,Folino R

    更新日期:2005-04-01 00:00:00

  • Discriminating and responsiveness abilities of two hearing handicap scales.

    abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199006000-00002

    authors: Mulrow CD,Tuley MR,Aguilar C

    更新日期:1990-06-01 00:00:00

  • Transfer functions and correction factors used in hearing aid evaluation and research.

    abstract::In hearing aid research and application it is often necessary to transform the sound pressure level or acoustic gain measured at one physical point (e.g., 2 cc coupler) to an equivalent value at another physical point (e.g., tympanic membrane). Results of currently available studies on various transformations are summ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198902000-00010

    authors: Bentler RA,Pavlovic CV

    更新日期:1989-02-01 00:00:00

  • The effect of otitis media with effusion at preschool age on some aspects of auditory perception at school age.

    abstract::The relationship between otitis media with effusion (OME) at preschool age and performance on five tests of auditory perception was studied in 89 school-age children who had OME histories well documented from participation in serial screening for OME at 2-4 yr of age. The tests used at 7.5-8 yr of age were: speech-in-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199406000-00003

    authors: Schilder AG,Snik AF,Straatman H,van den Broek P

    更新日期:1994-06-01 00:00:00

  • Relationship between two dichotic listening tests and the Token test for children.

    abstract::The relationship between two dichotic listening tasks was studied. The two dichotic tests used were the Staggered Spondaic Word (SSW) test and the directed Dichotic Consonant-Vowel (CV) test. These measures were administered to 104 children between the ages of 6.0 and 8.0 yrs. The subjects were divided into two groups...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198311000-00003

    authors: Harris VL,Keith RW,Novak KK

    更新日期:1983-11-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Do hearing loss and cognitive function modulate benefit from different binaural noise-reduction settings?

    abstract:OBJECTIVES:Although previous research indicates that cognitive skills influence benefit from different types of hearing aid algorithms, comparatively little is known about the role of, and potential interaction with, hearing loss. This holds true especially for noise reduction (NR) processing. The purpose of the presen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000003

    authors: Neher T,Grimm G,Hohmann V,Kollmeier B

    更新日期:2014-05-01 00:00:00

  • Auditory perception changes after reimplantation in a child cochlear implant user.

    abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199206000-00009

    authors: Chute PM,Hellman SA,Parisier SC,Tartter VC,Economou A

    更新日期:1992-06-01 00:00:00

  • The additive effect of co-occurring anxiety and depression on health status, quality of life and coping strategies in help-seeking tinnitus sufferers.

    abstract:OBJECTIVE:Evaluating the effect of anxiety and depression on clinical measures of general health, tinnitus-specific quality of life, and coping abilities. DESIGN:Two hundred sixty-five chronic, subjective tinnitus sufferers were divided into four psychological symptom groups according to cut-off scores on anxiety and ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181888f83

    authors: Bartels H,Middel BL,van der Laan BF,Staal MJ,Albers FW

    更新日期:2008-12-01 00:00:00

  • The contribution of amplitude envelope cues to sentence identification in young and aged listeners.

    abstract:OBJECTIVE:The purpose of this study was to examine the importance of amplitude envelope cues to sentence identification for aged listeners. We also examined the effect of increasing alterations (i.e., compression ratio) and amount of available frequency content (i.e., number of channels) for this population. DESIGN:Th...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200104000-00004

    authors: Souza PE,Kitch V

    更新日期:2001-04-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • Measures of digit span and verbal rehearsal speed in deaf children after more than 10 years of cochlear implantation.

    abstract:OBJECTIVES:Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of s...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181ffd58e

    authors: Pisoni DB,Kronenberger WG,Roman AS,Geers AE

    更新日期:2011-02-01 00:00:00

  • Noise levels in physicians' offices.

    abstract::The development of hand-held auditory screening devices has led to increased hearing screening by physicians. Ambient noise levels were assessed in examination rooms of 20 physician offices. Measurements provided Ln, Leq, Lmax, and octave band data for specialty types: pediatrics, internal medicine, family practice an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00012

    authors: Alvord LS

    更新日期:1990-10-01 00:00:00

  • Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.

    abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000562

    authors: Blankenship CM,Hunter LL,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-11-01 00:00:00

  • Pre- and Postoperative Binaural Unmasking for Bimodal Cochlear Implant Listeners.

    abstract:OBJECTIVES:Cochlear implants (CIs) are increasingly recommended to individuals with residual bilateral acoustic hearing. Although new hearing-preserving electrode designs and surgical approaches show great promise, CI recipients are still at risk to lose acoustic hearing in the implanted ear, which could prevent the ab...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000420

    authors: Sheffield BM,Schuchman G,Bernstein JGW

    更新日期:2017-09-01 00:00:00

  • List equivalency of the CID everyday sentences (Harris revision) under three signal-to-noise ratios.

    abstract::The primary purpose of this study was to determine list equivalency of Harris' revision of the CID Everyday Sentence Lists under three signal-to-noise ratios: O dB, --3 dB, and --6 dB. On the basis of list means, nonsignificant groupings of lists were found at each noise level; however, lists were not equivalent at an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198309000-00006

    authors: Rippy JV,Dancer JE,Pittenger JB

    更新日期:1983-09-01 00:00:00

  • Unilateral Hearing Loss: Understanding Speech Recognition and Localization Variability-Implications for Cochlear Implant Candidacy.

    abstract:OBJECTIVES:At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000380

    authors: Firszt JB,Reeder RM,Holden LK

    更新日期:2017-03-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Vestibular-evoked myogenic potential in the prediction of recovery from acute low-tone sensorineural hearing loss.

    abstract:OBJECTIVE:Click and galvanic stimulations of vestibular-evoked myogenic potential (c-VEMP and g-VEMP) were applied to measure the interaural difference (IAD) of saccular responses in patients with acute low-tone sensorineural hearing loss (ALHL). This study intended to explore the relationship between saccular asymmetr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/AUD.0b013e3181c5b743

    authors: Wang CT,Fang KM,Young YH,Cheng PW

    更新日期:2010-04-01 00:00:00

  • Behavioral Measures of Listening Effort in School-Age Children: Examining the Effects of Signal-to-Noise Ratio, Hearing Loss, and Amplification.

    abstract:OBJECTIVES:Increased listening effort in school-age children with hearing loss (CHL) could compromise learning and academic achievement. Identifying a sensitive behavioral measure of listening effort for this group could have both clinical and research value. This study examined the effects of signal-to-noise ratio (SN...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000623

    authors: McGarrigle R,Gustafson SJ,Hornsby BWY,Bess FH

    更新日期:2019-03-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Children's recognition of spectrally degraded cartoon voices.

    abstract:OBJECTIVES:Although the spectrally degraded input provided by cochlear implants (CIs) is sufficient for speech perception in quiet, it poses problems for talker identification. The present study examined the ability of normally hearing (NH) children and child CI users to recognize cartoon voices while listening to spec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a468d0

    authors: van Heugten M,Volkova A,Trehub SE,Schellenberg EG

    更新日期:2014-01-01 00:00:00

  • Prevalence of Hearing Loss Among a Representative Sample of Canadian Children and Adolescents, 3 to 19 Years of Age.

    abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000345

    authors: Feder KP,Michaud D,McNamee J,Fitzpatrick E,Ramage-Morin P,Beauregard Y

    更新日期:2017-01-01 00:00:00

  • Noise levels of electronic arcade games: a potential hearing hazard to children.

    abstract::A measurement of noise exposure levels of players of electronic games was made in two small arcades using a noise dosimeter. Two different measurements were made, at normal operating levels and maximum possible levels. The results showed that excessive exposure levels were possible on arcade games and that these level...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198307000-00005

    authors: Plakke BL

    更新日期:1983-07-01 00:00:00

  • Changes in the Compressive Nonlinearity of the Cochlea During Early Aging: Estimates From Distortion OAE Input/Output Functions.

    abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000319

    authors: Ortmann AJ,Abdala C

    更新日期:2016-09-01 00:00:00

  • Ocular and cervical vestibular-evoked myogenic potentials: a study to determine whether air- or bone-conducted stimuli are optimal.

    abstract:OBJECTIVES:The aim of this study was to determine whether bone-conducted vibration (BCV) or air-conducted sound (ACS) is the optimal mode for eliciting both ocular vestibular-evoked myogenic potentials (oVEMPs) and cervical VEMPs (cVEMPs). DESIGN:Twelve healthy volunteers, five patients with unilateral chronic otitis ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/AUD.0b013e3181bdbac0

    authors: Wang SJ,Weng WJ,Jaw FS,Young YH

    更新日期:2010-04-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Maturation of Mechanical Impedance of the Skin-Covered Skull: Implications for Soft Band Bone-Anchored Hearing Systems Fitted in Infants and Young Children.

    abstract:OBJECTIVES:Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull posi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000272

    authors: Mackey AR,Hodgetts WE,Scott D,Small SA

    更新日期:2016-07-01 00:00:00