Prevalence of Hearing Loss Among a Representative Sample of Canadian Children and Adolescents, 3 to 19 Years of Age.

Abstract:

OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAEs) for children and adolescents, aged 3 to 19 years. DESIGN:This cross-sectional population-based study presents findings from the 2012/2013 Canadian Health Measures Survey, entailing an in-person household interview and hearing measurements conducted in a mobile examination clinic. The initial study sample included 2591 participants, aged 3 to 19 years, representing 6.5 million Canadians (3.3 million males). After exclusions, subsamples consisted of 2434 participants, aged 3 to 19 years and 1879 participants, aged 6 to 19 years, with valid audiometric results. Eligible participants underwent otoscopic examination, tympanometry, DPOAE, and audiometry. HL was defined as a pure-tone average >20 dB for 6- to 18-year olds and ≥26 dB for 19-year olds, for one or more of the following: four-frequency (0.5, 1, 2, and 4 kHz) pure-tone average, high-frequency (3, 4, 6, and 8 kHz) pure-tone average, and low-frequency (0.5, 1, and 2 kHz) pure-tone average. Mild HL was defined as >20 to 40 dB (6- to 18-year olds) and ≥26 to 40 dB (19-year olds). Moderate or worse HL was defined as >40 dB (6- to 19-year olds). HL in 3- to 5-year olds (n = 555) was defined as absent DPOAEs as audiometry was not conducted. Self-reported HL was evaluated using the Health Utilities Index Mark 3 hearing questions. RESULTS:The primary study outcome indicates that 7.7% of Canadian youth, aged 6 to 19, had any HL, for one or more pure-tone average. Four-frequency pure-tone average and high-frequency pure-tone average HL prevalence was 4.7 and 6.0%, respectively, whereas 5.8% had a low-frequency pure-tone average HL. Significantly more children/adolescents had unilateral HL. Mild HL was significantly more common than moderate or worse HL for each pure-tone average. Among Canadians, aged 6 to 19, less than 2.2% had sensorineural HL. Among Canadians, aged 3 to 19, less than 3.5% had conductive HL. Absent DPOAEs were found in 7.1% of 3- to 5-year olds, and in 3.4% of 6- to 19-year olds. Among participants eligible for the hearing evaluation and excluding missing data cases (n = 2575), 17.0% had excessive or impacted pus/wax in one or both ears. Self-reported HL in Canadians, aged 6 to 19, was 0.6 E% and 65.3% (aged 3 to 19) reported never having had their hearing tested. E indicates that a high sampling variability is associated with the estimate (coefficient of variation between 16.6% and 33.3%) and should be interpreted with caution. CONCLUSIONS:This study provides the first estimates of audiometrically measured HL prevalence among Canadian children and adolescents. A larger proportion of youth have measured HL than was previously reported using self-report surveys, indicating that screening using self-report or proxy may not be effective in identifying individuals with mild HL. Results may underestimate the true prevalence of HL due to the large number excluded and the presentation of impacted or excessive earwax or pus, precluding an accurate or complete hearing evaluation. The majority of 3- to 5-year olds with absent DPOAEs likely had conductive HL. Nonetheless, this type of HL which can be asymptomatic, may become permanent if left untreated. Future research will benefit from analyses, which includes the slight HL category, for which there is growing support, and from studies that identify factors contributing to HL in this population.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Feder KP,Michaud D,McNamee J,Fitzpatrick E,Ramage-Morin P,Beauregard Y

doi

10.1097/AUD.0000000000000345

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

7-20

issue

1

eissn

0196-0202

issn

1538-4667

journal_volume

38

pub_type

杂志文章
  • Comparison of real-ear to coupler difference values in the right and left ear of adults using three earmold configurations.

    abstract:OBJECTIVE:The purpose of the study was to compare real-ear to coupler difference (RECD) values in the right and left ear of adults using three earmold configurations. DESIGN:The RECD was obtained from both ears of 18 normal hearing adults by subtracting the HA2 2-cc coupler response from the real-ear response using an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200506000-00005

    authors: Munro KJ,Buttfield LM

    更新日期:2005-06-01 00:00:00

  • Functional hearing loss and its relationship to resolved hearing levels.

    abstract::The nature of functional hearing loss was retrospectively studied with respect to hearing sensitivity after resolution of the nonorganic components in 63 adults with bilateral exaggerated losses (126 ears). The configuration of the functional components (difference between the functional and resolved thresholds) was f...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198505000-00005

    authors: Gelfand SA,Silman S

    更新日期:1985-05-01 00:00:00

  • Highly variable population-based prevalence rates of unilateral hearing loss after the application of common case definitions.

    abstract:OBJECTIVES:This study shows how population-based estimates of the prevalence of unilateral hearing loss (UHL) in children aged 6 to 19 yrs can differ considerably with various applications of commonly accepted case definitions. It also examines demographic variables and risk factors related to UHL. DESIGN:The Third Na...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181bb69db

    authors: Ross DS,Visser SN,Holstrum WJ,Qin T,Kenneson A

    更新日期:2010-02-01 00:00:00

  • Labeling of musical interval size by cochlear implant patients and normally hearing subjects.

    abstract:OBJECTIVE:To compare the performance of cochlear implant patients and normal-hearing subjects on a musical interval labeling task, and to determine whether information regarding musical interval size is available to cochlear implant patients under realistic everyday listening conditions. DESIGN:Two Nucleus cochlear im...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199710000-00002

    authors: Pijl S

    更新日期:1997-10-01 00:00:00

  • Evaluation of Long-Term Cochlear Implant Use in Subjects With Acquired Unilateral Profound Hearing Loss: Focus on Binaural Auditory Outcomes.

    abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000359

    authors: Mertens G,De Bodt M,Van de Heyning P

    更新日期:2017-01-01 00:00:00

  • Changes in the Compressive Nonlinearity of the Cochlea During Early Aging: Estimates From Distortion OAE Input/Output Functions.

    abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000319

    authors: Ortmann AJ,Abdala C

    更新日期:2016-09-01 00:00:00

  • Chronic Conductive Hearing Loss Is Associated With Speech Intelligibility Deficits in Patients With Normal Bone Conduction Thresholds.

    abstract:OBJECTIVES:The main objective of this study is to determine whether chronic sound deprivation leads to poorer speech discrimination in humans. DESIGN:We reviewed the audiologic profile of 240 patients presenting normal and symmetrical bone conduction thresholds bilaterally, associated with either an acute or chronic u...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000787

    authors: Okada M,Welling DB,Liberman MC,Maison SF

    更新日期:2020-05-01 00:00:00

  • A systematic review of the nonacoustic benefits of bone-anchored hearing AIDS.

    abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000240635.70277.3f

    authors: Johnson CE,Danhauer JL,Reith AC,Latiolais LN

    更新日期:2006-12-01 00:00:00

  • Interleaved Processors Improve Cochlear Implant Patients' Spectral Resolution.

    abstract:OBJECTIVE:Cochlear implant patients have difficulty in noisy environments, in part, because of channel interaction. Interleaving the signal by sending every other channel to the opposite ear has the potential to reduce channel interaction by increasing the space between channels in each ear. Interleaving still potentia...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000249

    authors: Aronoff JM,Stelmach J,Padilla M,Landsberger DM

    更新日期:2016-03-01 00:00:00

  • Signal to noise constraints on maximum length sequence auditory brain stem responses.

    abstract::In conventional auditory brain stem response (ABR) testing, the stimulus rate must be low enough that the responses do not overlap. By using stimulus patterns derived from the pseudorandom binary series known as maximum length sequences (MLSs), it is possible to stimulate at mean rates of hundreds of clicks per second...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199212000-00004

    authors: Marsh RR

    更新日期:1992-12-01 00:00:00

  • Sound Localization and Speech Perception in Noise of Pediatric Cochlear Implant Recipients: Bimodal Fitting Versus Bilateral Cochlear Implants.

    abstract:OBJECTIVES:The aim of this study was to compare binaural performance of auditory localization task and speech perception in babble measure between children who use a cochlear implant (CI) in one ear and a hearing aid (HA) in the other (bimodal fitting) and those who use bilateral CIs. DESIGN:Thirteen children (mean ag...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000401

    authors: Choi JE,Moon IJ,Kim EY,Park HS,Kim BK,Chung WH,Cho YS,Brown CJ,Hong SH

    更新日期:2017-07-01 00:00:00

  • Hearing impairment and health-related quality of life: the Blue Mountains Hearing Study.

    abstract:OBJECTIVES:To assess the association between hearing impairment and health-related quality of life (HRQOL) in an older population, using the self-administered 36-item Short-Form Health Survey (SF-36). DESIGN:Participants of the Blue Mountains Hearing Study (BMHS, N = 2956) attended a comprehensive interview and hearin...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31803126b6

    authors: Chia EM,Wang JJ,Rochtchina E,Cumming RR,Newall P,Mitchell P

    更新日期:2007-04-01 00:00:00

  • Development of the Connected Speech Test (CST).

    abstract::This paper describes the first phase in the development of the Connected Speech Test (CST). This test of intelligibility of everyday speech has been developed primarily for use as a criterion measure in investigations of hearing aid benefit. The test consists of 48 passages of conversationally produced connected speec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710001-00010

    authors: Cox RM,Alexander GC,Gilmore C

    更新日期:1987-10-01 00:00:00

  • Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.

    abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000562

    authors: Blankenship CM,Hunter LL,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-11-01 00:00:00

  • Phase stability of auditory steady state responses in newborn infants.

    abstract:OBJECTIVES:This study examined the phases of auditory steady state responses (ASSRs) evoked by exponentially amplitude-modulated (AM) tones in 44 newborn infants (within 3 days of birth) and in 15 older infants (within 3 to 15 wks of birth). Our hypothesis was that the phases of the ASSRs would show orderly changes wit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318212085e

    authors: Choi JM,Purcell DW,John MS

    更新日期:2011-09-01 00:00:00

  • Deaf children's processing of auditory, visual, and combined stimuli.

    abstract::One hundred eighty-four deaf children were presented auditory, visual (speechreading), and combined stimuli. Some subjects showed an enhancement of their processing abilities in the combined mode, some demonstrated no improvement, and others yielded reduced scores. A method of data analysis is proposed which could con...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198005000-00003

    authors: Holmes DW,Groccia B,Johnson K,Green W

    更新日期:1980-05-01 00:00:00

  • The effects of reversing the polarity of frequency-limited single-cycle stimuli on the human auditory brain stem response.

    abstract::This study was conducted to investigate morphologic differences in the ABR as a result of reversing the stimulus polarity of frequency-limited single-cycle stimuli in normal-hearing subjects. The results clearly demonstrate that large latency differences occur between condensation and rarefaction stimuli for low-frequ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199506000-00008

    authors: Orlando MS,Folsom RC

    更新日期:1995-06-01 00:00:00

  • Analog and zero phase-shift digital filtering of the auditory brain stem response waveform.

    abstract::Auditory brain stem response waveforms, derived from normal ears, were analyzed with a computer-based digital filtering program as a means of systematically evaluating the effects of phase-shift distortion. Off-line analysis involved the stimulated responses of a Butterworth-type filter at five high-pass and four low-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198612000-00006

    authors: Domico WD,Kavanagh KT

    更新日期:1986-12-01 00:00:00

  • Does the 40-Hz auditory steady-state response show the binaural masking level difference?

    abstract::In contrast to the transient (N1-P2) and steady-state (<20 Hz) cortical responses, neither the transient (auditory brain stem response) nor the steady-state (80 Hz) brain stem responses show the binaural masking level difference (BMLD). This study determined behavioral and 40-Hz auditory steady-state response (ASSR) B...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b61cc8

    authors: Ishida IM,Stapells DR

    更新日期:2009-12-01 00:00:00

  • The Moderating Effect of Success Importance on the Relationship Between Listening Demand and Listening Effort.

    abstract::A common element of the psychophysiological research on listening effort is the focus on listening demand as determinant of effort. The article discusses preceding studies and theorizing on effort to show that the link between listening demand and listening effort is moderated by various variables. Moreover, I will pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000295

    authors: Richter M

    更新日期:2016-07-01 00:00:00

  • Speech-in-speech listening on the LiSN-S test by older adults with good audiograms depends on cognition and hearing acuity at high frequencies.

    abstract:OBJECTIVES:The main objective was to investigate age-related differences on the listening in spatialized noise-sentences (LiSN-S) test in adults with normal audiometric thresholds in most of the speech range. A second objective was to examine the contributions of auditory, cognitive, and linguistic abilities to LiSN-S ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000096

    authors: Besser J,Festen JM,Goverts ST,Kramer SE,Pichora-Fuller MK

    更新日期:2015-01-01 00:00:00

  • Human Frequency Following Responses to Vocoded Speech: Amplitude Modulation Versus Amplitude Plus Frequency Modulation.

    abstract:OBJECTIVES:The most commonly employed speech processing strategies in cochlear implants (CIs) only extract and encode amplitude modulation (AM) in a limited number of frequency channels. proposed a novel speech processing strategy that encodes both frequency modulation (FM) and AM to improve CI performance. Using behav...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000756

    authors: Suresh CH,Krishnan A,Luo X

    更新日期:2020-03-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • Evaluation of four Spanish word-recognition-ability lists.

    abstract::Tests of word recognition ability (formerly Speech Discrimination) should be suitable for the linguistic background of the person being tested. Few efforts have been made to develop a standardized test in the Spanish language. Current literature reports on six studies that have several drawbacks. The purpose of the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198912000-00012

    authors: Weisleder P,Hodgson WR

    更新日期:1989-12-01 00:00:00

  • Psychometric Properties of Cognitive-Motor Dual-Task Studies With the Aim of Developing a Test Protocol for Persons With Vestibular Disorders: A Systematic Review.

    abstract:OBJECTIVES:Patients suffering from vestibular disorders (VD) often present with impairments in cognitive domains such as visuospatial ability, memory, executive function, attention, and processing speed. These symptoms can be attributed to extensive vestibular projections throughout the cerebral cortex and subcortex on...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000748

    authors: Danneels M,Van Hecke R,Keppler H,Degeest S,Cambier D,van de Berg R,Van Rompaey V,Maes L

    更新日期:2020-01-01 00:00:00

  • The Cost of Ménière's Disease: A Novel Multisource Approach.

    abstract:OBJECTIVES:To estimate the annual cost of Ménière's disease and the cost per person in the UK population and to investigate the direct and indirect costs of the condition. DESIGN:The authors utilized a multidata approach to provide the first estimate of the cost of Ménière's. Data from the UK Biobank (a study of 500,0...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000264

    authors: Tyrrell J,Whinney DJ,Taylor T

    更新日期:2016-05-01 00:00:00

  • Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor.

    abstract:OBJECTIVE:To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200110000-00007

    authors: Faulkner A,Rosen S,Wilkinson L

    更新日期:2001-10-01 00:00:00

  • Changes in transient-evoked otoacoustic emissions in the first month of life.

    abstract:OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819c4000

    authors: Prieve BA,Hancur-Bucci CA,Preston JL

    更新日期:2009-06-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Use of probe tube microphone measurements in hearing aid selection for children: some initial clinical experiences.

    abstract::Some initial experiences are described in which ear canal probe tube microphone measurements are used to determine hearing aid settings for children. Decisions are based upon ideas developed by Seewald and Ross (in Amplification for the Hearing Impaired, New York: Grune & Stratton, 1988: 213-267) and Seewald, Ross, an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198910000-00002

    authors: Hawkins DB,Morrison TM,Halligan PL,Cooper WA

    更新日期:1989-10-01 00:00:00