Abstract:
OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. DESIGN:This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. RESULTS:Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. CONCLUSIONS:Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Blankenship CM,Hunter LL,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin Ldoi
10.1097/AUD.0000000000000562subject
Has Abstractpub_date
2018-11-01 00:00:00pages
1075-1090issue
6eissn
0196-0202issn
1538-4667journal_volume
39pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVES:Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull posi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000272
更新日期:2016-07-01 00:00:00
abstract:OBJECTIVES:We report on the ability of patients fit with bilateral cochlear implants (CIs) to distinguish the front-back location of sound sources both with and without head movements. At issue was (i) whether CI patients are more prone to front-back confusions than normal hearing listeners for wideband, high-frequency...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000581
更新日期:2018-11-01 00:00:00
abstract:OBJECTIVE:The aim of the present experiment was to assess the consequences of cochlear implantation at different ages on the development of the human central auditory system. DESIGN:Our measure of the maturity of central auditory pathways was the latency of the P1 cortical auditory evoked potential. Because P1 latenci...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200212000-00004
更新日期:2002-12-01 00:00:00
abstract:OBJECTIVE:The purpose of the study was to compare real-ear to coupler difference (RECD) values in the right and left ear of adults using three earmold configurations. DESIGN:The RECD was obtained from both ears of 18 normal hearing adults by subtracting the HA2 2-cc coupler response from the real-ear response using an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200506000-00005
更新日期:2005-06-01 00:00:00
abstract::The development of hand-held auditory screening devices has led to increased hearing screening by physicians. Ambient noise levels were assessed in examination rooms of 20 physician offices. Measurements provided Ln, Leq, Lmax, and octave band data for specialty types: pediatrics, internal medicine, family practice an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199010000-00012
更新日期:1990-10-01 00:00:00
abstract:OBJECTIVE:To investigate the middle ear dynamic characteristics in patients with otosclerosis using the sweep frequency impedance meter (SFI test) and conventional tympanometry, and also to evaluate the diagnostic efficiency of the SFI test for otosclerosis. DESIGN:The study was designed to collect a total of 25 (36 e...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200204000-00007
更新日期:2002-04-01 00:00:00
abstract::Many people with difficulties following conversations in noisy settings have "clinically normal" audiograms, that is, tone thresholds better than 20 dB HL from 0.1 to 8 kHz. This review summarizes the possible causes of such difficulties, and examines established as well as promising new psychoacoustic and electrophys...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0000000000000388
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000693
更新日期:2019-09-01 00:00:00
abstract::An analysis is presented of the detectability of the two types of otoacoustic emissions being considered for use in clinical tests of hearing. It is estimated that, for equal emission levels and equal probability of error, measurement of distortion-product emissions can be made at least 30 times faster than transient-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199210000-00008
更新日期:1992-10-01 00:00:00
abstract::The present study was designed to investigate the effects of reference microphone location on probe tube microphone measures of hearing aid response. The reference microphone of a clinical probe tube microphone system was located either at a position on the cheek (position A) or in close proximity to the microphone of...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199010000-00001
更新日期:1990-10-01 00:00:00
abstract:OBJECTIVES:This study examined joint engagement and emotional availability of parent-child interactions for toddlers with moderate hearing loss (MHL) compared with toddlers with normal hearing (NH) and in relation to children's language abilities. DESIGN:The participants in this study were 25 children with MHL (40 to ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000596
更新日期:2019-01-01 00:00:00
abstract::The relationship between otitis media with effusion (OME) at preschool age and performance on five tests of auditory perception was studied in 89 school-age children who had OME histories well documented from participation in serial screening for OME at 2-4 yr of age. The tests used at 7.5-8 yr of age were: speech-in-...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199406000-00003
更新日期:1994-06-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. DESIGN:Eight adults who were bilateral users of Nucleus 24 Contour devices participated i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000249910.80803.b9
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVE:To investigate the applicability of the self-report inventory, Satisfaction with Amplification in Daily Life (SADL), at 2 wk postfitting. DESIGN:The SADL was completed by two groups of hearing aid users, one fitted 2 wk before completion, the other at least 1 yr before. All SADLs were completed as a paper an...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200108000-00008
更新日期:2001-08-01 00:00:00
abstract::Clinical auditory brain stem response latency measures are conventionally evaluated for abnormality by reference to normative laboratory values in standard deviation units. This note suggests that the directionality of the test hypothesis should be considered when the clinical ABR is evaluated for abnormality at a pre...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199002000-00007
更新日期:1990-02-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000188201.86799.01
更新日期:2005-12-01 00:00:00
abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0b013e31827ada02
更新日期:2013-07-01 00:00:00
abstract::This study examined whether female subjects who had balanced hormonal profiles and who were experiencing the characteristic fluctuation in estrogen and progesterone levels exhibited changes in auditory function unlike subjects who were using a low-dose combined estrogen and progesterone steroid. Threshold data at 500,...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198007000-00008
更新日期:1980-07-01 00:00:00
abstract:OBJECTIVES:Relationships between cognitive and sensory functioning become stronger with advancing age, and the debate on underlying mechanisms continues. Interestingly, the potential mechanism of compensation by the unaffected sensory modality has so far been investigated in younger age groups with congenital sensory i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000531
更新日期:2018-07-01 00:00:00
abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/01.aud.0000240635.70277.3f
更新日期:2006-12-01 00:00:00
abstract::This paper includes an overview of the research on late-onset auditory deprivation, an evaluation of the evidence from retrospective and prospective studies, recommendations for future research, and a consideration of the theoretical and clinical implications of the research. The studies reviewed offer convincing evid...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199617031-00002
更新日期:1996-06-01 00:00:00
abstract:OBJECTIVE:The purpose of this study is to present descriptive results from an audiometric examination of a male twin sample, compare the values with normative databases, and explore whether there are age differences in genetic and environmental contributions to variation in hearing. DESIGN:Audiometric and questionnair...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199704000-00003
更新日期:1997-04-01 00:00:00
abstract::Elderly individuals often have more deficits in speech understanding than would be expected in younger individuals with the same degree of hearing loss. Such deficits may be attributed to the complex nature of age-related changes that occur throughout the central auditory nervous system and are generally referred to a...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/00003446-199112001-00007
更新日期:1991-12-01 00:00:00
abstract:OBJECTIVES:Conventional assessments of outcomes in deaf children with cochlear implants (CIs) have focused primarily on endpoint or product measures of speech and language. Little attention has been devoted to understanding the basic underlying core neurocognitive factors involved in the development and processing of s...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181ffd58e
更新日期:2011-02-01 00:00:00
abstract:OBJECTIVE:A new speech processing concept and its implementation cochlear implant neural net, simulation and stimulation (CINSTIM), for cochlear implant systems is currently under investigation. The main objectives of this new strategy are to improve speech perception within the early rehabilitation period for prelingu...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199602000-00009
更新日期:1996-02-01 00:00:00
abstract:OBJECTIVE:This study compares the musical perception of 17 adult recipients of the Nucleus cochlear implant using two different formant extraction processing strategies (F0F1F2 and MPEAK). DESIGN:Over a 12 mo period, participants were alternately switched between two strategies every 3 mo. Performance was evaluated us...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199706000-00008
更新日期:1997-06-01 00:00:00
abstract:OBJECTIVES:Vestibular reflexes have traditionally formed the cornerstone of vestibular evaluation, but perceptual tests have recently gained attention for use in research studies and potential clinical applications. However, the unknown reliability of perceptual thresholds limits their current importance. This is addre...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000859
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVES:To report population-based prevalence of hearing impairment based on speech recognition in noise testing in a large and inclusive sample of U.K. adults aged 40 to 69 years. The present study is the first to report such data. Prevalence of tinnitus and use of hearing aids is also reported. DESIGN:The researc...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000010
更新日期:2014-05-01 00:00:00
abstract::A moderate-bandwidth master hearing aid was used to study the relationships among low-frequency response, syllable recognition scores, and perceived speech quality. As measured on KEMAR, this hearing aid provided true high-frequency emphasis in all conditions, with three degrees of relative low-frequency de-emphasis. ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198604000-00001
更新日期:1986-04-01 00:00:00
abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199910000-00001
更新日期:1999-10-01 00:00:00