Changes in transient-evoked otoacoustic emissions in the first month of life.

Abstract:

OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened as outpatients by 1 mo of age, at which time, approximately 50 to 70% pass screening criteria. To better understand why many infants are referred at initial screening but pass at the rescreening, more complete knowledge of developmental differences in the TEOAE levels, noise floor, or a combination of both for infants who pass and fail birth screening is needed. In addition, it has been shown that infants with occluding ear-canal debris are more likely to not pass TEOAE screening at the hospital than those without occluding ear-canal debris. This study explores whether changes in TEOAE levels in half-octave frequency bands are related to changes in ear-canal debris over the first month of life. DESIGN:Seventy-nine neonates from a well-baby nursery had their hearing screened before leaving the hospital and again at approximately 1 mo of age. All participants passed the follow-up screening. Overall TEOAE levels and levels in half-octave frequency bands centered at 1.5, 2, 3, and 4 kHz were measured. Judgments of ear-canal debris were made by otoscopy and were rated using one of three categories at both visits. RESULTS:TEOAE levels in infants significantly increased from birth to 1 mo of age across all frequencies tested, regardless of whether they passed or failed the screening at birth. The increase in TEOAE level was frequency dependent, with the greatest increases occurring in the highest frequency bands. No significant correlation between debris change and frequency-specific changes was found for either ear. Infants who failed the screening at birth but who subsequently passed at 1 mo of age had significantly lower TEOAE levels at the rescreening than did infants with passing TEOAE levels at birth. However, pass/fail status at birth was only a weak predictor of TEOAE levels at 1 mo of age. CONCLUSIONS:The increase in TEOAE levels during the first month of life is frequency dependent, with greater increases occurring at higher frequencies. Increased TEOAE levels were not associated with changes in ear-canal debris.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Prieve BA,Hancur-Bucci CA,Preston JL

doi

10.1097/AUD.0b013e31819c4000

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

330-9

issue

3

eissn

0196-0202

issn

1538-4667

journal_volume

30

pub_type

杂志文章
  • The Benefits of Increased Sensation Level and Bandwidth for Spatial Release From Masking.

    abstract:OBJECTIVE:Spatial release from masking (SRM) can increase speech intelligibility in complex listening environments. The goal of the present study was to document how speech-in-speech stimuli could be best processed to encourage optimum SRM for listeners who represent a range of ages and amounts of hearing loss. We exam...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000352

    authors: Jakien KM,Kampel SD,Gordon SY,Gallun FJ

    更新日期:2017-01-01 00:00:00

  • The use of averaged electrode voltages to assess the function of nucleus internal cochlear implant devices in children.

    abstract::Averaged electrode voltages (AEVs) provide an objective measure of the output of the Nucleus multichannel cochlear implant device. AEVs are the peak-to-peak voltages of each electrode in the internal array and are recorded from electrodes placed on the scalp. This article summarizes average voltage data for 25 childre...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199404000-00007

    authors: Mahoney MJ,Proctor LA

    更新日期:1994-04-01 00:00:00

  • Hearing deficits correlated with the timing of systemic disturbance as indicated by primary incisor defects.

    abstract::A correlation of hearing deficits and enamel defects was investigated in 18 children presenting to a pediatric neurology service for hearing evaluation. Eleven had enamel defects. Five had defects consistent with a systemic insult occurring as early as 14 weeks gestation, two between 29 to 33 weeks gestation, and four...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198509000-00006

    authors: Murray GS,Johnsen DC

    更新日期:1985-09-01 00:00:00

  • Time course and cost of misdirecting auditory spatial attention in younger and older adults.

    abstract:OBJECTIVES:The effects of directing, switching, and misdirecting auditory spatial attention in a complex listening situation were investigated in 8 younger and 8 older listeners with normal-hearing sensitivity below 4 kHz. DESIGN:In two companion experiments, a target sentence was presented from one spatial location a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31829bf6ec

    authors: Singh G,Pichora-Fuller MK,Schneider BA

    更新日期:2013-11-01 00:00:00

  • Auditory perception changes after reimplantation in a child cochlear implant user.

    abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199206000-00009

    authors: Chute PM,Hellman SA,Parisier SC,Tartter VC,Economou A

    更新日期:1992-06-01 00:00:00

  • Noise levels of electronic arcade games: a potential hearing hazard to children.

    abstract::A measurement of noise exposure levels of players of electronic games was made in two small arcades using a noise dosimeter. Two different measurements were made, at normal operating levels and maximum possible levels. The results showed that excessive exposure levels were possible on arcade games and that these level...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198307000-00005

    authors: Plakke BL

    更新日期:1983-07-01 00:00:00

  • Repeatability of high-frequency bone conduction thresholds.

    abstract::The purpose of this study was to determine the repeatability of high-frequency, bone conduction thresholds and to increase the data base concerning high-frequency, bone conduction threshold levels. Bone conduction thresholds were obtained on 30 subjects having normal, low, and mid frequency (0.25 to 8 kHz) hearing thr...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-198712000-00010

    authors: Frank T,Ragland AE

    更新日期:1987-12-01 00:00:00

  • Auditory Acclimatization to Bilateral Hearing Aids: Effects on Sentence-in-Noise Processing Times and Speech-Evoked Potentials.

    abstract:OBJECTIVES:Using a longitudinal design, the present study sought to substantiate indications from two previous cross-sectional studies that hearing aid (HA) experience leads to improved speech processing abilities as quantified using eye-gaze measurements. Another aim was to explore potential concomitant changes in eve...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000476

    authors: Habicht J,Finke M,Neher T

    更新日期:2018-01-01 00:00:00

  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Real ear attenuation at threshold for three audiometric headphone devices: implications for maximum permissible ambient noise level standards.

    abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199202000-00004

    authors: Franks JR,Engel DP 3rd,Themann CL

    更新日期:1992-02-01 00:00:00

  • Impact of Lexical Parameters and Audibility on the Recognition of the Freiburg Monosyllabic Speech Test.

    abstract:OBJECTIVE:Correct word recognition is generally determined by audibility, but lexical parameters also play a role. The focus of this study was to examine both the impact of audibility and lexical parameters on speech recognition of test words of the clinical German Freiburg monosyllabic speech test, and subsequently on...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000737

    authors: Winkler A,Carroll R,Holube I

    更新日期:2020-01-01 00:00:00

  • Identification of middle ear effusion by aural acoustic admittance and otoscopy.

    abstract::The ability of aural acoustic immittance measures and validated pneumatic otoscopy to identify middle ear effusion (MEE) was determined for a group of children with chronic or recurrent otitis media. The measures were made immediately prior to surgery for placement of tympanostomy tubes, with the validating diagnosis ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199408000-00005

    authors: Nozza RJ,Bluestone CD,Kardatzke D,Bachman R

    更新日期:1994-08-01 00:00:00

  • Four earplugs in search of a rating system.

    abstract:OBJECTIVE:The performance of four insert earplugs was evaluated by determining the Noise Reduction Rating (NRR) and the Subject-Fit Noise Reduction Rating [NRR(SF)]. The NRR and NRR(SF) were calculated from real-ear attenuation at threshold (REAT) data collected using the experimenter-fit protocol described in the now-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200006000-00005

    authors: Franks JR,Murphy WJ,Johnson JL,Harris DA

    更新日期:2000-06-01 00:00:00

  • Test-retest reliability of the hearing handicap inventory for adults.

    abstract::The test-retest reliability of the Hearing Handicap Inventory for Adults (HHIA) was assessed on a sample of 28 hearing-impaired adults. Reliability estimates were obtained to set the stage for using the HHIA as an outcome measure in aural rehabilitation. The test-retest reliability was quite high (r = 0.97) and the st...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199110000-00009

    authors: Newman CW,Weinstein BE,Jacobson GP,Hug GA

    更新日期:1991-10-01 00:00:00

  • Melodic contour identification by cochlear implant listeners.

    abstract:OBJECTIVE:While the cochlear implant provides many deaf patients with good speech understanding in quiet, music perception and appreciation with the cochlear implant remains a major challenge for most cochlear implant users. The present study investigated whether a closed-set melodic contour identification (MCI) task c...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000261689.35445.20

    authors: Galvin JJ 3rd,Fu QJ,Nogaki G

    更新日期:2007-06-01 00:00:00

  • The leisure-noise dilemma: hearing loss or hearsay? What does the literature tell us?

    abstract::The authors undertook a review of the literature, focussing on publications describing the following: (1) Pure tone threshold data for adolescents/young adults; (2) Measurements/estimates of noise exposure from leisure activities; and (3) The relationship between hearing threshold levels (HTLs) and leisure-noise expos...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000451498.92871.20

    authors: Carter L,Williams W,Black D,Bundy A

    更新日期:2014-09-01 00:00:00

  • Reliability of Vestibular Perceptual Threshold Testing About the Yaw Axis.

    abstract:OBJECTIVES:Vestibular reflexes have traditionally formed the cornerstone of vestibular evaluation, but perceptual tests have recently gained attention for use in research studies and potential clinical applications. However, the unknown reliability of perceptual thresholds limits their current importance. This is addre...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000859

    authors: Lee TL,Shayman CS,Oh Y,Peterka RJ,Hullar TE

    更新日期:2020-11-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Maturation of the contralaterally recorded auditory brain stem response.

    abstract::Ipsilaterally and contralaterally recorded auditory brain stem responses to 80 dB nHL clicks were recorded from 37 infants, aged 2 weeks to 20 mo and from six adults, all with normal auditory function. With increasing age, contralateral waves A, B, C, and D and ipsilateral waves III and V decreased in latency, with th...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199106000-00002

    authors: Stapells DR,Mosseri M

    更新日期:1991-06-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Discriminating and responsiveness abilities of two hearing handicap scales.

    abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199006000-00002

    authors: Mulrow CD,Tuley MR,Aguilar C

    更新日期:1990-06-01 00:00:00

  • Perception of rhythmic and sequential pitch patterns by normally hearing adults and adult cochlear implant users.

    abstract:OBJECTIVE:This study compares the musical perception of 17 adult recipients of the Nucleus cochlear implant using two different formant extraction processing strategies (F0F1F2 and MPEAK). DESIGN:Over a 12 mo period, participants were alternately switched between two strategies every 3 mo. Performance was evaluated us...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199706000-00008

    authors: Gfeller K,Woodworth G,Robin DA,Witt S,Knutson JF

    更新日期:1997-06-01 00:00:00

  • Transfer functions and correction factors used in hearing aid evaluation and research.

    abstract::In hearing aid research and application it is often necessary to transform the sound pressure level or acoustic gain measured at one physical point (e.g., 2 cc coupler) to an equivalent value at another physical point (e.g., tympanic membrane). Results of currently available studies on various transformations are summ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198902000-00010

    authors: Bentler RA,Pavlovic CV

    更新日期:1989-02-01 00:00:00

  • Behavioral Pure-Tone Threshold Shifts Caused by Tympanic Membrane Electrodes.

    abstract:OBJECTIVE:To determine whether tympanic membrane (TM) electrodes induce behavioral pure-tone threshold shifts. DESIGN:Pure-tone thresholds (250 to 8000 Hz) were measured twice in test (n = 18) and control (n = 10) groups. TM electrodes were placed between first and second threshold measurements in the test group, wher...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000275

    authors: Smith SB,Lichtenhan J,Cone B

    更新日期:2016-07-01 00:00:00

  • Auditory N1 component to gaps in continuous narrowband noises.

    abstract:OBJECTIVES:To determine whether (1) the auditory N1 component can be elicited to gaps in continuous narrowband noises, (2) psychophysical and electrophysiological gap thresholds (PGTs and EGTs) are similar to one another, and (3) EGTs are the same for all narrowband noise center frequencies. DESIGN:PGTs and EGTs were ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b1354f

    authors: Atcherson SR,Gould HJ,Mendel MI,Ethington CA

    更新日期:2009-12-01 00:00:00

  • Hypercholesterolemia is correlated with an increased risk of idiopathic sudden sensorineural hearing loss: a historical prospective cohort study.

    abstract:OBJECTIVE:Despite the many studies on the associated risk of cardiovascular and cerebrovascular events in patients with hypercholesterolemia (HCh), an association between HCh and the development of idiopathic sudden sensorineural hearing loss (ISSNHL) has been examined in only a few case-control studies. We tested the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a76637

    authors: Chang SL,Hsieh CC,Tseng KS,Weng SF,Lin YS

    更新日期:2014-03-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • The mismatch negativity: a powerful tool for cognitive neuroscience.

    abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:

    authors: Näätänen R

    更新日期:1995-02-01 00:00:00

  • Retest stability of the communication profile for the hearing impaired.

    abstract::Retest stability of the Communication Profile for the Hearing Impaired (CPHI) was assessed in a sample of 101 active-duty military personnel who attended the Aural Rehabilitation Program at Walter Reed Army Medical Center. Pretests were administered by referring audiologists; retests were administered from 6 to 40 wee...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198810000-00002

    authors: Demorest ME,Erdman SA

    更新日期:1988-10-01 00:00:00

  • Impact of laser eustachian tuboplasty on middle ear ventilation, hearing, and tinnitus in chronic tube dysfunction.

    abstract:OBJECTIVES:Long-term Eustachian tube dysfunction (ETD) predisposes to various secondary middle ear diseases. Most surgical and prosthetical interventions on the Eustachian tube itself have proven to be ineffective, whereas middle ear surgeries treat the sequelae of ETD without major influence on the underlying tubal pa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e85614

    authors: Caffier PP,Sedlmaier B,Haupt H,Göktas O,Scherer H,Mazurek B

    更新日期:2011-02-01 00:00:00