Abstract:
:In hearing aid research and application it is often necessary to transform the sound pressure level or acoustic gain measured at one physical point (e.g., 2 cc coupler) to an equivalent value at another physical point (e.g., tympanic membrane). Results of currently available studies on various transformations are summarized in this report. When no data were available, the desired transfer function was calculated as a linear combination of known contributing transfer functions. Values are given for the center frequencies of 1/3 octaves and critical bands.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Bentler RA,Pavlovic CVdoi
10.1097/00003446-198902000-00010subject
Has Abstractpub_date
1989-02-01 00:00:00pages
58-63issue
1eissn
0196-0202issn
1538-4667journal_volume
10pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract::Acoustic reflex thresholds (ARTs) at 500, 1000, and 2000 Hz from 1833 ears were subjected to multiple linear regression analyses using a stepwise inclusion model to determine the effects of hearing losses in the 500- to 4000-Hz range for each of the activators. Although statistically significant regression equations w...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198407000-00007
更新日期:1984-07-01 00:00:00
abstract:OBJECTIVES:To undertake a systematic review of available evidence on the effect of hearing impairment and hearing aid amplification on listening effort. Two research questions were addressed: Q1) does hearing impairment affect listening effort? and Q2) can hearing aid amplification affect listening effort during speech...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0000000000000396
更新日期:2017-05-01 00:00:00
abstract:OBJECTIVES:This study compared speech recognition performance on the Northwestern University Auditory Test No. 6 (NU-6) and the Connected Speech Test (CST) for three hearing aid circuits (peak clipping [PC], compression limiting [CL], and wide dynamic range compression [WDRC]) in adults with symmetrical sensorineural h...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200208000-00003
更新日期:2002-08-01 00:00:00
abstract:OBJECTIVE:To evaluate the ability of clinical test signals to match the aided levels of real speech, across a range of hearing aid circuit types and strengths. DESIGN:Hearing aids (N = 41) were set to DSL targets for moderate, severe, and profound hearing losses. These hearing aids were tested with three test signals ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200210000-00009
更新日期:2002-10-01 00:00:00
abstract:OBJECTIVE:This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus(R) multichannel auditory brainstem implant. DESIGN:Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects in...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/00003446-200206000-00002
更新日期:2002-06-01 00:00:00
abstract::The auditory middle latency response (MLR) seems to have a relatively long developmental time course, extending through the first decade of life. Characteristics of each MLR component change developmentally not only with respect to waveform morphology but also with respect to response reliability, dependence on awaren...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/00003446-199610000-00008
更新日期:1996-10-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN:This is a prospective, longitudinal study of 231 in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000542
更新日期:2018-09-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000188201.86799.01
更新日期:2005-12-01 00:00:00
abstract:OBJECTIVE:The aim of the present experiment was to assess the consequences of cochlear implantation at different ages on the development of the human central auditory system. DESIGN:Our measure of the maturity of central auditory pathways was the latency of the P1 cortical auditory evoked potential. Because P1 latenci...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-200212000-00004
更新日期:2002-12-01 00:00:00
abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198411000-00004
更新日期:1984-11-01 00:00:00
abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199006000-00002
更新日期:1990-06-01 00:00:00
abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e318181ad99
更新日期:2008-12-01 00:00:00
abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199910000-00001
更新日期:1999-10-01 00:00:00
abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e318157676d
更新日期:2007-12-01 00:00:00
abstract::In recent years there has been an increased acceptance of the cochlear implant as an appropriate sensory aid for selected hearing-impaired individuals with profound losses. With the Food and Drug Administration's release of the 3M/House single channel cochlear implant on November 29, 1984 and the Nucleus 22-channel co...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198604000-00003
更新日期:1986-04-01 00:00:00
abstract::Identification errors for initial consonants of consonants-vowels-consonants-vowels from lists A and B of the Nonsense Syllable Test were analyzed for 10 normal-hearing and 8 sensorineural hearing-impaired listeners. The Nonsense Syllable Test stimuli were presented binaurally through earphones at 6 increasing sensati...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198105000-00006
更新日期:1981-05-01 00:00:00
abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31803153ac
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVE:Recent studies indicate that high-frequency amplification may provide little benefit for listeners with moderate-to-severe high-frequency hearing loss, and may even reduce speech recognition. Moore and colleagues have proposed a direct link between this lack of benefit and the presence of regions of nonfuncti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.AUD.0000058148.27540.D9
更新日期:2003-04-01 00:00:00
abstract:OBJECTIVE:The primary purpose of this study was to determine the distortion product otoacoustic emission (DPOAE) and noise response characteristics in a large sample of older adults. Another purpose was to evaluate how specific absolute DPOAE levels or DPOAE/Noise ratios differentiated hearing status in these individua...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.AUD.0000051847.66944.2B
更新日期:2003-02-01 00:00:00
abstract::This article reviews research on the relatively recently discovered event-related potential component, the mismatch negativity (MMN), which is of great potential interest for understanding central auditory function and various forms of its pathology. This change-specific response can serve as an accurate objective mea...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:
更新日期:1995-02-01 00:00:00
abstract:OBJECTIVES:To evaluate the influence of auditory cues on postural sway in normal-hearing (NH) individuals, hearing-impaired individuals with vestibular impairment (HIVL), or hearing-impaired (HI) individuals without vestibular impairment. DESIGN:Thirty-two participants received a hearing and a vestibular evaluation (v...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000720
更新日期:2019-11-01 00:00:00
abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199202000-00004
更新日期:1992-02-01 00:00:00
abstract::To provide insight into the behavioral characteristics of people who listen excessively to loud music, the 32-item Northeastern Excessive Music Listening Survey was developed and administered to 90 subjects. Results indicate that 8 of the 90 subjects scored within a range that would suggest the presence of a maladapti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199812000-00003
更新日期:1998-12-01 00:00:00
abstract:OBJECTIVE:This study completed an evidence-based practice systematic review of the nonacoustic benefits for adult patients receiving bone-anchored hearing aid(s) (BAHAs) relative to other forms of amplification (i.e., none, bone-conduction hearing aids [BCHAs], or air-conduction hearing aids [ACHAs]). DESIGN:Systemati...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/01.aud.0000240635.70277.3f
更新日期:2006-12-01 00:00:00
abstract::A measurement of noise exposure levels of players of electronic games was made in two small arcades using a noise dosimeter. Two different measurements were made, at normal operating levels and maximum possible levels. The results showed that excessive exposure levels were possible on arcade games and that these level...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198307000-00005
更新日期:1983-07-01 00:00:00
abstract::The auditory steady state potentials may be an important technique in objective audiometry. The effects of stimulus rate, intensity, and tonal frequency on these potentials were investigated using both signal averaging and on-line Fourier analysis. Stimulus presentation rates of 40 to 45/sec result in a 40 Hz sinusoid...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198403000-00009
更新日期:1984-03-01 00:00:00
abstract:OBJECTIVES:To investigate the correlations between hearing handicap, speech recognition, listening effort, and fatigue. DESIGN:Eighty-four adults with hearing loss (65 to 85 years) completed three self-report questionnaires: the Fatigue Assessment Scale, the Effort Assessment Scale, and the Hearing Handicap Inventory ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000515
更新日期:2018-05-01 00:00:00
abstract::Humans have evolved the unique capacity to efficiently communicate using the spoken word. Hearing plays a key role as a receiver in this process and dysfunction leads to difficulties in listening and communication. It is widely accepted that effective communication is not adequately captured with current behavioral sp...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000939
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31819c4000
更新日期:2009-06-01 00:00:00
abstract:OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at a...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000250
更新日期:2016-05-01 00:00:00