Objective calibration of bone conductors using otoacoustic emissions.

Abstract:

OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique were investigated through subjective phase cancellation measurements and sensitivity analysis. RESULTS:Calibrations obtained using the DPOAE method were well supported by phase cancellation results. Intersession repeatability was good, and manipulation of the DPOAE data showed that the calculated calibration is relatively insensitive to small variations of emission magnitude. Bilateral stimulation through bone conduction did not display an apparent effect on emission magnitude in a single individual. CONCLUSION:Bone conductors can be accurately calibrated on an individual basis with good repeatability using DPOAEs. The technique is robust and offers an objective, noninvasive calibration method for research and specialized clinical applications. No training and only passive cooperation are required, making the procedure ideal for special groups such as children. A number of limitations will reduce the clinical utility of this technique. Important audiometric frequencies below 1 kHz cannot be tested because of noise, because individuals with significant hearing loss are unlikely to produce sufficient DPOAEs, and because commercial bone conductors typically have poor high-frequency response above 4 kHz.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Purcell D,Kunov H,Cleghorn W

doi

10.1097/00003446-199910000-00001

subject

Has Abstract

pub_date

1999-10-01 00:00:00

pages

375-92

issue

5

eissn

0196-0202

issn

1538-4667

journal_volume

20

pub_type

杂志文章
  • Cochlear implantation with the nucleus slim straight electrode in subjects with residual low-frequency hearing.

    abstract:OBJECTIVES:To measure benefit in terms of speech recognition in quiet and in noise, and conservation of residual hearing in three groups of subjects implanted with the Nucleus Straight Research Array cochlear implant. This device incorporates the Nucleus Slim Straight electrode carrier designed to be easier to insert i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000444781.15858.f1

    authors: Skarzynski H,Lorens A,Matusiak M,Porowski M,Skarzynski PH,James CJ

    更新日期:2014-03-01 00:00:00

  • Audiologic findings in botulism poisoning.

    abstract::Botulism poisoning results in a presynaptic failure of neuromuscular transmission, and may be expected to impair Eustachian tube and stapedius reflex function. The audiologic findings in five normal-hearing patients with type A botulism poisoning are presented. Results were varied. Two patients demonstrated type B or ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199108000-00007

    authors: Pijl S

    更新日期:1991-08-01 00:00:00

  • Children's recognition of spectrally degraded cartoon voices.

    abstract:OBJECTIVES:Although the spectrally degraded input provided by cochlear implants (CIs) is sufficient for speech perception in quiet, it poses problems for talker identification. The present study examined the ability of normally hearing (NH) children and child CI users to recognize cartoon voices while listening to spec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a468d0

    authors: van Heugten M,Volkova A,Trehub SE,Schellenberg EG

    更新日期:2014-01-01 00:00:00

  • Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise.

    abstract:OBJECTIVE:The purposes of this study were to (a) examine the accuracy of cochlear implant recipients who use different types of devices and signal processing strategies on pitch ranking as a function of size of interval and frequency range and (b) to examine the relations between this pitch perception measure and demog...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3180479318

    authors: Gfeller K,Turner C,Oleson J,Zhang X,Gantz B,Froman R,Olszewski C

    更新日期:2007-06-01 00:00:00

  • Auditory N1 component to gaps in continuous narrowband noises.

    abstract:OBJECTIVES:To determine whether (1) the auditory N1 component can be elicited to gaps in continuous narrowband noises, (2) psychophysical and electrophysiological gap thresholds (PGTs and EGTs) are similar to one another, and (3) EGTs are the same for all narrowband noise center frequencies. DESIGN:PGTs and EGTs were ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181b1354f

    authors: Atcherson SR,Gould HJ,Mendel MI,Ethington CA

    更新日期:2009-12-01 00:00:00

  • Evaluation of Long-Term Cochlear Implant Use in Subjects With Acquired Unilateral Profound Hearing Loss: Focus on Binaural Auditory Outcomes.

    abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000359

    authors: Mertens G,De Bodt M,Van de Heyning P

    更新日期:2017-01-01 00:00:00

  • Effects of Head Movements on Sound-Source Localization in Single-Sided Deaf Patients With Their Cochlear Implant On Versus Off.

    abstract:OBJECTIVES:We investigated the ability of single-sided deaf listeners implanted with a cochlear implant (SSD-CI) to (1) determine the front-back and left-right location of sound sources presented from loudspeakers surrounding the listener and (2) use small head rotations to further improve their localization performanc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000882

    authors: Pastore MT,Natale SJ,Clayton C,Dorman MF,Yost WA,Zhou Y

    更新日期:2020-11-01 00:00:00

  • Longitudinal changes in word recognition by patients who use the Ineraid cochlear implant.

    abstract::The time course for reacquisition of spondee word recognition was examined for 27 patients who use the Ineraid cochlear implant. At 1 month postfitting, test scores ranged from 0 to 84% correct. The median score was 10% correct. At 22 to 28 months postfitting, the scores ranged from 0 to 100% correct. The median score...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199012000-00008

    authors: Dorman MF,Dankowski K,McCandless G,Parkin JL,Smith L

    更新日期:1990-12-01 00:00:00

  • Middle ear dynamic characteristics in patients with otosclerosis.

    abstract:OBJECTIVE:To investigate the middle ear dynamic characteristics in patients with otosclerosis using the sweep frequency impedance meter (SFI test) and conventional tympanometry, and also to evaluate the diagnostic efficiency of the SFI test for otosclerosis. DESIGN:The study was designed to collect a total of 25 (36 e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200204000-00007

    authors: Zhao F,Wada H,Koike T,Ohyama K,Kawase T,Stephens D

    更新日期:2002-04-01 00:00:00

  • Features from normal and sensorineural listeners' nonsense syllable test errors.

    abstract::Identification errors for initial consonants of consonants-vowels-consonants-vowels from lists A and B of the Nonsense Syllable Test were analyzed for 10 normal-hearing and 8 sensorineural hearing-impaired listeners. The Nonsense Syllable Test stimuli were presented binaurally through earphones at 6 increasing sensati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198105000-00006

    authors: Doyle KJ,Danhauer JL,Edgerton BJ

    更新日期:1981-05-01 00:00:00

  • Speech-in-speech listening on the LiSN-S test by older adults with good audiograms depends on cognition and hearing acuity at high frequencies.

    abstract:OBJECTIVES:The main objective was to investigate age-related differences on the listening in spatialized noise-sentences (LiSN-S) test in adults with normal audiometric thresholds in most of the speech range. A second objective was to examine the contributions of auditory, cognitive, and linguistic abilities to LiSN-S ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000096

    authors: Besser J,Festen JM,Goverts ST,Kramer SE,Pichora-Fuller MK

    更新日期:2015-01-01 00:00:00

  • Labeling of musical interval size by cochlear implant patients and normally hearing subjects.

    abstract:OBJECTIVE:To compare the performance of cochlear implant patients and normal-hearing subjects on a musical interval labeling task, and to determine whether information regarding musical interval size is available to cochlear implant patients under realistic everyday listening conditions. DESIGN:Two Nucleus cochlear im...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199710000-00002

    authors: Pijl S

    更新日期:1997-10-01 00:00:00

  • Use of the Connected Speech Test (CST) with hearing-impaired listeners.

    abstract::Two studies were performed in which hearing-impaired subjects responded to the Connected Speech Test (CST). In experiment 1, 40 subjects, divided into four groups according to extent and configuration of hearing loss, responded to the CST version 1 (CSTv1). This version of the test consisted of 57 passages of connecte...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198808000-00005

    authors: Cox RM,Alexander GC,Gilmore C,Pusakulich KM

    更新日期:1988-08-01 00:00:00

  • Callsign Acquisition Test (CAT): speech intelligibility in noise.

    abstract:OBJECTIVE:The study was designed to assess the effects of noise on the intelligibility of speech elements used in the Callsign Acquisition Test (CAT), developed by the U.S. Army Research Laboratory. The CAT consists of 126 test items, or callsigns, each of which is made up of a two-syllable word selected from the 18-it...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000202289.32228.f6

    authors: Rao MD,Letowski T

    更新日期:2006-04-01 00:00:00

  • Cochlear Reflectance and Otoacoustic Emission Predictions of Hearing Loss.

    abstract:OBJECTIVES:Cochlear reflectance (CR) is the cochlear contribution to ear-canal reflectance. CR is a type of otoacoustic emission (OAE) that is calculated as a transfer function between forward pressure and reflected pressure. The purpose of this study was to compare wideband CR to distortion-product (DP) OAEs in two wa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000677

    authors: Neely ST,Fultz SE,Kopun JG,Lenzen NM,Rasetshwane DM

    更新日期:2019-07-01 00:00:00

  • Changes in the Compressive Nonlinearity of the Cochlea During Early Aging: Estimates From Distortion OAE Input/Output Functions.

    abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000319

    authors: Ortmann AJ,Abdala C

    更新日期:2016-09-01 00:00:00

  • Top-Down Processes in Simulated Electric-Acoustic Hearing: The Effect of Linguistic Context on Bimodal Benefit for Temporally Interrupted Speech.

    abstract:OBJECTIVES:Previous studies have documented the benefits of bimodal hearing as compared with a cochlear implant alone, but most have focused on the importance of bottom-up, low-frequency cues. The purpose of the present study was to evaluate the role of top-down processing in bimodal hearing by measuring the effect of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000298

    authors: Oh SH,Donaldson GS,Kong YY

    更新日期:2016-09-01 00:00:00

  • Recognizing spoken words: the neighborhood activation model.

    abstract:OBJECTIVE:A fundamental problem in the study of human spoken word recognition concerns the structural relations among the sound patterns of words in memory and the effects these relations have on spoken word recognition. In the present investigation, computational and experimental methods were employed to address a num...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199802000-00001

    authors: Luce PA,Pisoni DB

    更新日期:1998-02-01 00:00:00

  • The risks of amplified music for disc-jockeys working in nightclubs.

    abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819769fc

    authors: Potier M,Hoquet C,Lloyd R,Nicolas-Puel C,Uziel A,Puel JL

    更新日期:2009-04-01 00:00:00

  • Auditory steady state cortical responses indicate deviant phonemic-rate processing in adults with dyslexia.

    abstract:OBJECTIVES:Speech intelligibility is strongly influenced by the ability to process temporal modulations. It is hypothesized that in dyslexia, deficient processing of rapidly changing auditory information underlies a deficient development of phonological representations, causing reading and spelling problems. Low-freque...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31822c26b9

    authors: Poelmans H,Luts H,Vandermosten M,Boets B,Ghesquière P,Wouters J

    更新日期:2012-01-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Evaluation of a localization training program for hearing impaired listeners.

    abstract:OBJECTIVE:To evaluate the effectiveness of a home-based and a laboratory-based localization training program. DESIGN:This study examined the effectiveness of a localization training program on improving the localization ability of 15 participants with a mild-to-moderately severe hearing loss. These participants had wo...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000067

    authors: Kuk F,Keenan DM,Lau C,Crose B,Schumacher J

    更新日期:2014-11-01 00:00:00

  • The influence of clicks versus short tone bursts on the vestibular evoked myogenic potentials.

    abstract:OBJECTIVE:Vestibular evoked myogenic potential (VEMP) has become a diagnostic tool to evaluate the integrity of sacculo-collic reflex. To obtain a more consistent VEMP response in normal-hearing subjects, we examine whether clicks or short tone bursts are more effective in eliciting VEMP responses. DESIGN:Prospective ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000069225.80220.CB

    authors: Cheng PW,Huang TW,Young YH

    更新日期:2003-06-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.

    abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000562

    authors: Blankenship CM,Hunter LL,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-11-01 00:00:00

  • Hearing deficits correlated with the timing of systemic disturbance as indicated by primary incisor defects.

    abstract::A correlation of hearing deficits and enamel defects was investigated in 18 children presenting to a pediatric neurology service for hearing evaluation. Eleven had enamel defects. Five had defects consistent with a systemic insult occurring as early as 14 weeks gestation, two between 29 to 33 weeks gestation, and four...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198509000-00006

    authors: Murray GS,Johnsen DC

    更新日期:1985-09-01 00:00:00

  • The leisure-noise dilemma: hearing loss or hearsay? What does the literature tell us?

    abstract::The authors undertook a review of the literature, focussing on publications describing the following: (1) Pure tone threshold data for adolescents/young adults; (2) Measurements/estimates of noise exposure from leisure activities; and (3) The relationship between hearing threshold levels (HTLs) and leisure-noise expos...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000451498.92871.20

    authors: Carter L,Williams W,Black D,Bundy A

    更新日期:2014-09-01 00:00:00

  • Phase stability of auditory steady state responses in newborn infants.

    abstract:OBJECTIVES:This study examined the phases of auditory steady state responses (ASSRs) evoked by exponentially amplitude-modulated (AM) tones in 44 newborn infants (within 3 days of birth) and in 15 older infants (within 3 to 15 wks of birth). Our hypothesis was that the phases of the ASSRs would show orderly changes wit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318212085e

    authors: Choi JM,Purcell DW,John MS

    更新日期:2011-09-01 00:00:00

  • Spoken word recognition development in children with residual hearing using cochlear implants and hearing AIDS in opposite ears.

    abstract:OBJECTIVE:With broadening candidacy criteria for cochlear implantation, a greater number of pediatric candidates have usable residual hearing in their nonimplanted ears. This population potentially stands to benefit from continued use of conventional amplification in their nonimplanted ears. The purposes of this invest...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200508001-00010

    authors: Holt RF,Kirk KI,Eisenberg LS,Martinez AS,Campbell W

    更新日期:2005-08-01 00:00:00

  • Cost-Effective Hearing Conservation: Regulatory and Research Priorities.

    abstract::Hearing conservation programs (HCPs) mandated by the US Occupational Safety and Health Administration (OSHA) cost about $350/worker/year. Are they cost-effective? A cross-sectional model of the US adult population with and without HCPs incorporates (1) the American Medical Association's method for estimating binaural ...

    journal_title:Ear and hearing

    pub_type: 社论

    doi:10.1097/AUD.0000000000000523

    authors: Dobie RA

    更新日期:2018-07-01 00:00:00