Accuracy of cochlear implant recipients on pitch perception, melody recognition, and speech reception in noise.

Abstract:

OBJECTIVE:The purposes of this study were to (a) examine the accuracy of cochlear implant recipients who use different types of devices and signal processing strategies on pitch ranking as a function of size of interval and frequency range and (b) to examine the relations between this pitch perception measure and demographic variables, melody recognition, and speech reception in background noise. DESIGN:One hundred fourteen cochlear implant users and 21 normal-hearing adults were tested on a pitch discrimination task (pitch ranking) that required them to determine direction of pitch change as a function of base frequency and interval size. Three groups were tested: (a) long electrode cochlear implant users (N = 101); (b) short electrode users that received acoustic plus electrical stimulation (A+E) (N = 13); and (c) a normal-hearing (NH) comparison group (N = 21). Pitch ranking was tested at standard frequencies of 131 to 1048 Hz, and the size of the pitch-change intervals ranged from 1 to 4 semitones. A generalized linear mixed model (GLMM) was fit to predict pitch ranking and to determine if group differences exist as a function of base frequency and interval size. Overall significance effects were measured with Chi-square tests and individual effects were measured with t-tests. Pitch ranking accuracy was correlated with demographic measures (age at time of testing, length of profound deafness, months of implant use), frequency difference limens, familiar melody recognition, and two measures of speech reception in noise. RESULTS:The long electrode recipients performed significantly poorer on pitch discrimination than the NH and A+E group. The A+E users performed similarly to the NH listeners as a function of interval size in the lower base frequency range, but their pitch discrimination scores deteriorated slightly in the higher frequency range. The long electrode recipients, although less accurate than participants in the NH and A+E groups, tended to perform with greater accuracy within the higher frequency range. There were statistically significant correlations between pitch ranking and familiar melody recognition as well as with pure-tone frequency difference limens at 200 and 400 Hz. CONCLUSIONS:Low-frequency acoustic hearing improves pitch discrimination as compared with traditional, electric-only cochlear implants. These findings have implications for musical tasks such as familiar melody recognition.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Gfeller K,Turner C,Oleson J,Zhang X,Gantz B,Froman R,Olszewski C

doi

10.1097/AUD.0b013e3180479318

subject

Has Abstract

pub_date

2007-06-01 00:00:00

pages

412-23

issue

3

eissn

0196-0202

issn

1538-4667

pii

00003446-200706000-00014

journal_volume

28

pub_type

杂志文章
  • The influence of RECD transducer when deriving real-ear sound pressure level.

    abstract:OBJECTIVE:The main aim of the present study was to compare the derived and directly measured real-ear hearing instrument performance for a range of commonly used hearing instruments. A secondary aim was to compare the real-ear to coupler difference (RECD) measured using the ER-3A insert earphone and a selection of hear...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000224123.22568.82

    authors: Munro KJ,Millward KE

    更新日期:2006-08-01 00:00:00

  • Effects of channel-to-electrode mappings on speech reception with the ineraid cochlear implant.

    abstract:OBJECTIVE:Research was conducted to assess multichannel saliency with the Ineraid cochlear prosthesis. The goal was to determine whether tonotopically ordered stimulation benefits speech reception. DESIGN:In a single high-performing subject, changes in speech reception were studied during two dramatic alterations to t...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199510000-00002

    authors: Rabinowitz WM,Eddington DK

    更新日期:1995-10-01 00:00:00

  • Retest stability of the communication profile for the hearing impaired.

    abstract::Retest stability of the Communication Profile for the Hearing Impaired (CPHI) was assessed in a sample of 101 active-duty military personnel who attended the Aural Rehabilitation Program at Walter Reed Army Medical Center. Pretests were administered by referring audiologists; retests were administered from 6 to 40 wee...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198810000-00002

    authors: Demorest ME,Erdman SA

    更新日期:1988-10-01 00:00:00

  • Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

    abstract:OBJECTIVE:Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). DESIGN:Audiometric and noise e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181d94e68

    authors: Zhao YM,Qiu W,Zeng L,Chen SS,Cheng XR,Davis RI,Hamernik RP

    更新日期:2010-08-01 00:00:00

  • Restoring Perceived Loudness for Listeners With Hearing Loss.

    abstract:OBJECTIVES:Normalizing perceived loudness is an important rationale for gain adjustments in hearing aids. It has been demonstrated that gains required for restoring normal loudness perception for monaural narrowband signals can lead to higher-than-normal loudness in listeners with hearing loss, particularly for binaura...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000521

    authors: Oetting D,Hohmann V,Appell JE,Kollmeier B,Ewert SD

    更新日期:2018-07-01 00:00:00

  • Longitudinal Development of Distortion Product Otoacoustic Emissions in Infants With Normal Hearing.

    abstract:OBJECTIVES:The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN:This is a prospective, longitudinal study of 231 in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000542

    authors: Hunter LL,Blankenship CM,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-09-01 00:00:00

  • Four earplugs in search of a rating system.

    abstract:OBJECTIVE:The performance of four insert earplugs was evaluated by determining the Noise Reduction Rating (NRR) and the Subject-Fit Noise Reduction Rating [NRR(SF)]. The NRR and NRR(SF) were calculated from real-ear attenuation at threshold (REAT) data collected using the experimenter-fit protocol described in the now-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200006000-00005

    authors: Franks JR,Murphy WJ,Johnson JL,Harris DA

    更新日期:2000-06-01 00:00:00

  • Predictability of speech-in-noise performance from real ear measures of directional hearing AIDS.

    abstract:OBJECTIVE:Inability to understand speech in noise has been cited repeatedly as the principal complaint of hearing aid users. While data exist documenting the benefit provided by hearing aids with directional microphones when listening to speech in noise, little work has been done to develop a standard clinical protocol...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000121236.56217.8f

    authors: Dhar S,Humes LE,Calandruccio L,Barlow NN,Hipskind N

    更新日期:2004-04-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Late-onset auditory deprivation: a review of past research and an assessment of future research needs.

    abstract::This paper includes an overview of the research on late-onset auditory deprivation, an evaluation of the evidence from retrospective and prospective studies, recommendations for future research, and a consideration of the theoretical and clinical implications of the research. The studies reviewed offer convincing evid...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199617031-00002

    authors: Neuman AC

    更新日期:1996-06-01 00:00:00

  • Maturation of Mechanical Impedance of the Skin-Covered Skull: Implications for Soft Band Bone-Anchored Hearing Systems Fitted in Infants and Young Children.

    abstract:OBJECTIVES:Little is known about the maturational changes in the mechanical properties of the skull and how they might contribute to infant-adult differences in bone conduction hearing sensitivity. The objective of this study was to investigate the mechanical impedance of the skin-covered skull for different skull posi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000272

    authors: Mackey AR,Hodgetts WE,Scott D,Small SA

    更新日期:2016-07-01 00:00:00

  • Neurophysiological Differences in Emotional Processing by Cochlear Implant Users, Extending Beyond the Realm of Speech.

    abstract:OBJECTIVE:Cochlear implants (CIs) restore a sense of hearing in deaf individuals. However, they do not transmit the acoustic signal with sufficient fidelity, leading to difficulties in recognizing emotions in voice and in music. The study aimed to explore the neurophysiological bases of these limitations. DESIGN:Twent...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000701

    authors: Deroche MLD,Felezeu M,Paquette S,Zeitouni A,Lehmann A

    更新日期:2019-09-01 00:00:00

  • Sensory-Cognitive Interactions in Older Adults.

    abstract::The objective of this study was regarding sensory and cognitive interactions in older adults published since 2009, the approximate date of the most recent reviews on this topic. After an electronic database search of articles published in English since 2009 on measures of hearing and cognition or vision and cognition ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000303

    authors: Humes LE,Young LA

    更新日期:2016-07-01 00:00:00

  • Effect of eye closure, mental concentration, and nonauditory sensory stimulation on the threshold and magnitude of the acoustic reflex.

    abstract::Acoustic reflex threshold and magnitude were measured for normal-hearing subjects in four experiments under conditions of: (1) tight and relaxed eyelid closure; (2) eyes open and closed in light, focusing on a spot, reading, and solving a visual maze; (3) tactile stimulation; and (4) performing a mental task. Measurem...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198207000-00007

    authors: Robinette MS,Snyder KS

    更新日期:1982-07-01 00:00:00

  • Callsign Acquisition Test (CAT): speech intelligibility in noise.

    abstract:OBJECTIVE:The study was designed to assess the effects of noise on the intelligibility of speech elements used in the Callsign Acquisition Test (CAT), developed by the U.S. Army Research Laboratory. The CAT consists of 126 test items, or callsigns, each of which is made up of a two-syllable word selected from the 18-it...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000202289.32228.f6

    authors: Rao MD,Letowski T

    更新日期:2006-04-01 00:00:00

  • SSW test performance-intensity functions for hearing-impaired adults.

    abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198411000-00004

    authors: Flynn PA,Danhauer JL,Gerber SE,Goller MC,Arnst DJ

    更新日期:1984-11-01 00:00:00

  • The Role of Lexical Tone Information in the Recognition of Mandarin Sentences in Listeners With Hearing Aids.

    abstract:OBJECTIVES:Lexical tone information provides redundant cues for the recognition of Mandarin sentences in listeners with normal hearing in quiet conditions. The contribution of lexical tones to Mandarin sentence recognition in listeners with hearing aids (HAs) is unclear. This study aimed to remove lexical tone informat...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000774

    authors: Chen Y,Wong LLN,Qian J,Kuehnel V,Christina Voss S,Chen F

    更新日期:2020-05-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • Visual Acuity and Cognition in Older Adults With and Without Hearing Loss: Evidence For Late-Life Sensory Compensation?

    abstract:OBJECTIVES:Relationships between cognitive and sensory functioning become stronger with advancing age, and the debate on underlying mechanisms continues. Interestingly, the potential mechanism of compensation by the unaffected sensory modality has so far been investigated in younger age groups with congenital sensory i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000531

    authors: Wettstein M,Wahl HW,Heyl V

    更新日期:2018-07-01 00:00:00

  • Hearing impairment and health-related quality of life: the Blue Mountains Hearing Study.

    abstract:OBJECTIVES:To assess the association between hearing impairment and health-related quality of life (HRQOL) in an older population, using the self-administered 36-item Short-Form Health Survey (SF-36). DESIGN:Participants of the Blue Mountains Hearing Study (BMHS, N = 2956) attended a comprehensive interview and hearin...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31803126b6

    authors: Chia EM,Wang JJ,Rochtchina E,Cumming RR,Newall P,Mitchell P

    更新日期:2007-04-01 00:00:00

  • Multisite Randomized Controlled Trial to Compare Two Methods of Tinnitus Intervention to Two Control Conditions.

    abstract:OBJECTIVES:In this four-site clinical trial, we evaluated whether tinnitus masking (TM) and tinnitus retraining therapy (TRT) decreased tinnitus severity more than the two control groups: an attention-control group that received tinnitus educational counseling (and hearing aids if needed; TED), and a 6-month-wait-list ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1097/AUD.0000000000000330

    authors: Henry JA,Stewart BJ,Griest S,Kaelin C,Zaugg TL,Carlson K

    更新日期:2016-11-01 00:00:00

  • Evaluation of streamlined programming procedures for the Nucleus cochlear implant with the Contour electrode array.

    abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000188201.86799.01

    authors: Plant K,Law MA,Whitford L,Knight M,Tari S,Leigh J,Pedley K,Nel E

    更新日期:2005-12-01 00:00:00

  • Current state of knowledge: outcomes research in children with mild to severe hearing impairment--approaches and methodological considerations.

    abstract::This paper will provide a backdrop to the others in this section on outcomes of children with mild to moderate sensorineural hearing loss. Our objective here is to provide an overview of the research approaches used to study the outcomes of these children to provide guidance for future studies of children with mild to...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e318157f093

    authors: Tomblin B,Hebbeler K

    更新日期:2007-12-01 00:00:00

  • Interleaved Processors Improve Cochlear Implant Patients' Spectral Resolution.

    abstract:OBJECTIVE:Cochlear implant patients have difficulty in noisy environments, in part, because of channel interaction. Interleaving the signal by sending every other channel to the opposite ear has the potential to reduce channel interaction by increasing the space between channels in each ear. Interleaving still potentia...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000249

    authors: Aronoff JM,Stelmach J,Padilla M,Landsberger DM

    更新日期:2016-03-01 00:00:00

  • Using multichannel wide-dynamic range compression in severely hearing-impaired listeners: effects on speech recognition and quality.

    abstract:OBJECTIVE:The objective of this study was to compare speech recognition across a sampling of amplification choices available for listeners with severe loss. This includes conventional options (linear with peak clipping and linear with compression limiting) and newer strategies (multichannel wide-dynamic range compressi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200504000-00002

    authors: Souza PE,Jenstad LM,Folino R

    更新日期:2005-04-01 00:00:00

  • Americans hear as well or better today compared with 40 years ago: hearing threshold levels in the unscreened adult population of the United States, 1959-1962 and 1999-2004.

    abstract:OBJECTIVES:(1) To present hearing threshold data from a recent nationally representative survey in the United States (National Health and Nutrition Examination Survey, 1999-2004) in a distributional format that might be appropriate to replace Annex B in international (ISO-1999) and national (ANSI S3.44) standards and (...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e9770e

    authors: Hoffman HJ,Dobie RA,Ko CW,Themann CL,Murphy WJ

    更新日期:2010-12-01 00:00:00

  • Pre- and Postoperative Binaural Unmasking for Bimodal Cochlear Implant Listeners.

    abstract:OBJECTIVES:Cochlear implants (CIs) are increasingly recommended to individuals with residual bilateral acoustic hearing. Although new hearing-preserving electrode designs and surgical approaches show great promise, CI recipients are still at risk to lose acoustic hearing in the implanted ear, which could prevent the ab...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000420

    authors: Sheffield BM,Schuchman G,Bernstein JGW

    更新日期:2017-09-01 00:00:00

  • The risks of amplified music for disc-jockeys working in nightclubs.

    abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819769fc

    authors: Potier M,Hoquet C,Lloyd R,Nicolas-Puel C,Uziel A,Puel JL

    更新日期:2009-04-01 00:00:00

  • Evaluation of electroacoustic test signals I: comparison with amplified speech.

    abstract:OBJECTIVE:To evaluate the ability of clinical test signals to match the aided levels of real speech, across a range of hearing aid circuit types and strengths. DESIGN:Hearing aids (N = 41) were set to DSL targets for moderate, severe, and profound hearing losses. These hearing aids were tested with three test signals ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200210000-00009

    authors: Scollie SD,Seewald RC

    更新日期:2002-10-01 00:00:00

  • Impact of Lexical Parameters and Audibility on the Recognition of the Freiburg Monosyllabic Speech Test.

    abstract:OBJECTIVE:Correct word recognition is generally determined by audibility, but lexical parameters also play a role. The focus of this study was to examine both the impact of audibility and lexical parameters on speech recognition of test words of the clinical German Freiburg monosyllabic speech test, and subsequently on...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000737

    authors: Winkler A,Carroll R,Holube I

    更新日期:2020-01-01 00:00:00