Event-related potentials in pediatric cochlear implant patients.

Abstract:

OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated auditory event-related potentials to standard and deviant speech stimuli presented in a pseudorandom sequence in 35 cochlear implant patients between the ages of 7 and 17 yr. We compared the occurrence, latencies, and amplitudes of P1, N2, and MMN with overall behavioral outcome in these children. Behavioral measures included category of auditory performance scores and speech intelligibility rating scores. RESULTS:Auditory ERPs in response to standard stimuli were identifiable in 30 of 35 patients, demonstrating a major positive component (P1) followed by a negativity (N2) with absence of N1 in all patients. The P1 component in prelingually deaf patients showed a statistically significant reduction in its latency with increasing duration of implant use. MMN was recorded in 80-85% of star performers but in only 15-20% of poor performers. Patients with higher SIR scores demonstrated statistically significant longer duration of MMN compared with those with a lower SIR score. CONCLUSIONS:These results indicate that MMN can be used to assess the functional status of the auditory cortex in terms of auditory memory and discrimination in young children with cochlear implants and may provide an objective mechanism for differentiating good from poor performers.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Singh S,Liasis A,Rajput K,Towell A,Luxon L

doi

10.1097/00003446-200412000-00008

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

598-610

issue

6

eissn

0196-0202

issn

1538-4667

pii

00003446-200412000-00008

journal_volume

25

pub_type

杂志文章
  • Monothermal Caloric Screening to Improve Healthcare Value.

    abstract:OBJECTIVES:To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN:Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary refe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000262

    authors: Thatcher AL,Beckerman ML,Telian SA,King WM

    更新日期:2016-05-01 00:00:00

  • Age-related asymmetry on a cued-listening task.

    abstract::We report results on a cued-listening task designed to simulate the listening problems commonly described by individuals with sensorineural hearing loss, especially those experienced by elderly persons. Against a background of multitalker babble, the subject detected targets embedded in continuous discourse. Noncohere...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199208000-00009

    authors: Jerger J,Jordan C

    更新日期:1992-08-01 00:00:00

  • Parents' preferences for services for children with hearing loss: a conjoint analysis study.

    abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318157676d

    authors: Fitzpatrick E,Coyle DE,Durieux-Smith A,Graham ID,Angus DE,Gaboury I

    更新日期:2007-12-01 00:00:00

  • Development of the Connected Speech Test (CST).

    abstract::This paper describes the first phase in the development of the Connected Speech Test (CST). This test of intelligibility of everyday speech has been developed primarily for use as a criterion measure in investigations of hearing aid benefit. The test consists of 48 passages of conversationally produced connected speec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710001-00010

    authors: Cox RM,Alexander GC,Gilmore C

    更新日期:1987-10-01 00:00:00

  • Search for Electrophysiological Indices of Hidden Hearing Loss in Humans: Click Auditory Brainstem Response Across Sound Levels and in Background Noise.

    abstract:OBJECTIVES:Recent studies in animals indicate that even moderate levels of exposure to noise can damage synaptic ribbons between the inner hair cells and auditory nerve fibers without affecting audiometric thresholds, giving rise to the use of the term "hidden hearing loss" (HHL). Despite evidence across several animal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000905

    authors: Suresh CH,Krishnan A

    更新日期:2020-07-13 00:00:00

  • Spoken word recognition development in children with residual hearing using cochlear implants and hearing AIDS in opposite ears.

    abstract:OBJECTIVE:With broadening candidacy criteria for cochlear implantation, a greater number of pediatric candidates have usable residual hearing in their nonimplanted ears. This population potentially stands to benefit from continued use of conventional amplification in their nonimplanted ears. The purposes of this invest...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200508001-00010

    authors: Holt RF,Kirk KI,Eisenberg LS,Martinez AS,Campbell W

    更新日期:2005-08-01 00:00:00

  • Human auditory evoked potentials to frequency-modulated tones.

    abstract::Three experiments evaluated steady state and transient auditory evoked potentials (EPs) to tones that were sinusoidally modulated in frequency and to tones that alternated between two frequencies with a linear ramp. The steady state responses to sinusoidal FM were small and difficult to record at both the first and se...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198906000-00003

    authors: Maiste A,Picton T

    更新日期:1989-06-01 00:00:00

  • Effects of a Nucleus multichannel cochlear implant upon speech production in children.

    abstract::The purpose of this report is to describe the speech production of children participating in the Food and Drug Administration's approved clinical trials for the Nucleus multichannel cochlear implant. A significant increase in the ability to imitate nonsegmental aspects of speech was noted after using the implant; howe...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-199108001-00007

    authors: Tobey EA,Hasenstab S

    更新日期:1991-08-01 00:00:00

  • The effect of reference microphone placement on sound pressure levels at an ear level hearing aid microphone.

    abstract::The present study was designed to investigate the effects of reference microphone location on probe tube microphone measures of hearing aid response. The reference microphone of a clinical probe tube microphone system was located either at a position on the cheek (position A) or in close proximity to the microphone of...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00001

    authors: Feigin JA,Barlow NL,Stelmachowicz PG

    更新日期:1990-10-01 00:00:00

  • Perception of rhythmic and sequential pitch patterns by normally hearing adults and adult cochlear implant users.

    abstract:OBJECTIVE:This study compares the musical perception of 17 adult recipients of the Nucleus cochlear implant using two different formant extraction processing strategies (F0F1F2 and MPEAK). DESIGN:Over a 12 mo period, participants were alternately switched between two strategies every 3 mo. Performance was evaluated us...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199706000-00008

    authors: Gfeller K,Woodworth G,Robin DA,Witt S,Knutson JF

    更新日期:1997-06-01 00:00:00

  • Effects of an adaptive filter hearing aid on speech recognition in noise by hearing-impaired subjects.

    abstract::In a digitally controlled adaptive filter, ongoing detection and spectral analysis of quasi steady state noise are performed, and analog filter parameters are adjusted to provide greatest attenuation in frequency regions where noise energy is greatest. Attenuation introduced by the filter affects both speech and noise...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198802000-00012

    authors: van Tasell DJ,Larsen SY,Fabry DA

    更新日期:1988-02-01 00:00:00

  • Pitfalls in neurotologic diagnosis.

    abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198804000-00007

    authors: Telian SA,Kileny PR

    更新日期:1988-04-01 00:00:00

  • Features from normal and sensorineural listeners' nonsense syllable test errors.

    abstract::Identification errors for initial consonants of consonants-vowels-consonants-vowels from lists A and B of the Nonsense Syllable Test were analyzed for 10 normal-hearing and 8 sensorineural hearing-impaired listeners. The Nonsense Syllable Test stimuli were presented binaurally through earphones at 6 increasing sensati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198105000-00006

    authors: Doyle KJ,Danhauer JL,Edgerton BJ

    更新日期:1981-05-01 00:00:00

  • Predictability of speech-in-noise performance from real ear measures of directional hearing AIDS.

    abstract:OBJECTIVE:Inability to understand speech in noise has been cited repeatedly as the principal complaint of hearing aid users. While data exist documenting the benefit provided by hearing aids with directional microphones when listening to speech in noise, little work has been done to develop a standard clinical protocol...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000121236.56217.8f

    authors: Dhar S,Humes LE,Calandruccio L,Barlow NN,Hipskind N

    更新日期:2004-04-01 00:00:00

  • Cochlear versus retrocochlear presbyacusis: clinical correlates.

    abstract::This study reviews audiologic findings on cases of hearing-impaired elderly adults who were matched on the basis of peripheral hearing loss and who were divided into cochlear and retrocochlear groups on the basis of auditory brain stem response (ABR) test results. ABR test results were compared to other audiologic tes...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199102000-00008

    authors: Rizzo SR Jr,Gutnick HN

    更新日期:1991-02-01 00:00:00

  • The Moderating Effect of Success Importance on the Relationship Between Listening Demand and Listening Effort.

    abstract::A common element of the psychophysiological research on listening effort is the focus on listening demand as determinant of effort. The article discusses preceding studies and theorizing on effort to show that the link between listening demand and listening effort is moderated by various variables. Moreover, I will pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000295

    authors: Richter M

    更新日期:2016-07-01 00:00:00

  • Consonant recognition and confusion patterns among elderly hearing-impaired subjects.

    abstract::This study investigated whether unique consonant recognition and confusion patterns are associated with hearing loss among elderly listeners. Subjects were all greater than 65 years, and had normal hearing, or gradually or sharply sloping sensorineural hearing losses. Recognition of 19 consonants, paired with each of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710000-00003

    authors: Gordon-Salant S

    更新日期:1987-10-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Labeling of musical interval size by cochlear implant patients and normally hearing subjects.

    abstract:OBJECTIVE:To compare the performance of cochlear implant patients and normal-hearing subjects on a musical interval labeling task, and to determine whether information regarding musical interval size is available to cochlear implant patients under realistic everyday listening conditions. DESIGN:Two Nucleus cochlear im...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199710000-00002

    authors: Pijl S

    更新日期:1997-10-01 00:00:00

  • Auditory Acclimatization to Bilateral Hearing Aids: Effects on Sentence-in-Noise Processing Times and Speech-Evoked Potentials.

    abstract:OBJECTIVES:Using a longitudinal design, the present study sought to substantiate indications from two previous cross-sectional studies that hearing aid (HA) experience leads to improved speech processing abilities as quantified using eye-gaze measurements. Another aim was to explore potential concomitant changes in eve...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000476

    authors: Habicht J,Finke M,Neher T

    更新日期:2018-01-01 00:00:00

  • Noise-induced otoacoustic emission loss with or without hearing loss.

    abstract::The association between audiometric hearing thresholds and click-evoked otoacoustic emission (CEOAE) spectral properties was examined in 129 adult subjects with and without a noise-induced hearing loss (NIHL). Subjects were grouped according to their "beginning of hearing loss frequency" and their exposure to hazardou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199512000-00007

    authors: Attias J,Furst M,Furman V,Reshef I,Horowitz G,Bresloff I

    更新日期:1995-12-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • New York State universal newborn hearing screening demonstration project: effects of screening protocol on inpatient outcome measures.

    abstract:OBJECTIVE:To examine differences among various test protocols on the fail rate at hospital discharge for infants in the well-baby nursery (WBN) and neonatal intensive care unit (NICU) who received hearing screening through a universal newborn hearing screening demonstration project. DESIGN:The outcomes of several scre...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00003446-200004000-00007

    authors: Gravel J,Berg A,Bradley M,Cacace A,Campbell D,Dalzell L,DeCristofaro J,Greenberg E,Gross S,Orlando M,Pinheiro J,Regan J,Spivak L,Stevens F,Prieve B

    更新日期:2000-04-01 00:00:00

  • Test-retest reliability of the hearing handicap inventory for adults.

    abstract::The test-retest reliability of the Hearing Handicap Inventory for Adults (HHIA) was assessed on a sample of 28 hearing-impaired adults. Reliability estimates were obtained to set the stage for using the HHIA as an outcome measure in aural rehabilitation. The test-retest reliability was quite high (r = 0.97) and the st...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199110000-00009

    authors: Newman CW,Weinstein BE,Jacobson GP,Hug GA

    更新日期:1991-10-01 00:00:00

  • Exploring the role of the modulation spectrum in phoneme recognition.

    abstract:OBJECTIVES:The ability of human listeners to identify consonants (presented as nonsense syllables) on the basis of primarily temporal information was compared with the predictions of a simple model based on the amplitude modulation spectra of the stimuli calculated for six octave-spaced carrier frequencies (250 to 8000...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31817e73ef

    authors: Gallun F,Souza P

    更新日期:2008-10-01 00:00:00

  • Longitudinal changes in word recognition by patients who use the Ineraid cochlear implant.

    abstract::The time course for reacquisition of spondee word recognition was examined for 27 patients who use the Ineraid cochlear implant. At 1 month postfitting, test scores ranged from 0 to 84% correct. The median score was 10% correct. At 22 to 28 months postfitting, the scores ranged from 0 to 100% correct. The median score...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199012000-00008

    authors: Dorman MF,Dankowski K,McCandless G,Parkin JL,Smith L

    更新日期:1990-12-01 00:00:00

  • Noise levels in physicians' offices.

    abstract::The development of hand-held auditory screening devices has led to increased hearing screening by physicians. Ambient noise levels were assessed in examination rooms of 20 physician offices. Measurements provided Ln, Leq, Lmax, and octave band data for specialty types: pediatrics, internal medicine, family practice an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00012

    authors: Alvord LS

    更新日期:1990-10-01 00:00:00

  • Air-Conducted Vestibular Evoked Myogenic Potential Testing in Children, Adolescents, and Young Adults: Thresholds, Frequency Tuning, and Effects of Sound Exposure.

    abstract:OBJECTIVES:Pediatric vestibular evaluations incorporate cervical and ocular vestibular evoked myogenic potential (c- and oVEMP, respectively) testing; however, in children, c- and oVEMP thresholds have been minimally investigated and frequency tuning is unknown. Children are also at risk for unsafe sound exposure secon...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000607

    authors: Rodriguez AI,Thomas MLA,Janky KL

    更新日期:2019-01-01 00:00:00

  • Hearing handicap ratings among different profiles of adult cochlear implant users.

    abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31815d6da8

    authors: Noble W,Tyler R,Dunn C,Bhullar N

    更新日期:2008-01-01 00:00:00

  • Discriminating and responsiveness abilities of two hearing handicap scales.

    abstract::Several scales exist for screening handicap and assessing rehabilitation in elderly individuals with hearing loss. There are few comparative studies, however, to suggest which scales perform best. Using receiver-operating curves and responsiveness indices, we examined the relative discriminating ability and sensitivit...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199006000-00002

    authors: Mulrow CD,Tuley MR,Aguilar C

    更新日期:1990-06-01 00:00:00