Hearing handicap ratings among different profiles of adult cochlear implant users.

Abstract:

OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to factor analyze the two measures used, namely, the Hearing Handicap Inventory for the Elderly (HHIE) and the Hearing Handicap Questionnaire (HHQ). Longer versus shorter-term experience with a single implant profile was compared, and further analysis confined to patients fit for less than 100 mo across the three profiles. Pre- versus postimplant self-report and performance (speech test, localization) data were also compared. RESULTS:Three factors were identified in the HHIE, labeled Emotional Distress (HHIE), Difficulty in Hearing, and Social Restriction (HHIE). Highest handicap score for Emotional Distress (HHIE) was observed in the CI + HA group. There were significantly lower scores for Difficulty in Hearing in the CI + CI group than in the CI (p = 0.02) or CI + HA (p = 0.001) groups. On the Social Restriction (HHIE) subscale, the CI + CI group reported significantly lower rating than the CI (p = 0.009) or CI + HA (p = 0.006) groups. Two factors were identified in the HHQ, labeled Emotional Distress (HHQ) and Social Restriction (HHQ). Significantly higher Emotional Distress (HHQ) score was observed in the CI + HA group than in the CI + CI group (p = 0.002); significantly lower Social Restriction (HHQ) score was found in the CI + CI group than in the CI (p = 0.02) or CI + HA (p < 0.001) groups. Pre-post speech test performance showed least contrast in the CI + HA group. CONCLUSIONS:Outcomes demonstrate an evident reduction from single or bilateral implantation in the area of emotional distress and a further advantage from bilateral implantation in the areas of hearing difficulty and social restriction.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Noble W,Tyler R,Dunn C,Bhullar N

doi

10.1097/AUD.0b013e31815d6da8

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

112-20

issue

1

eissn

0196-0202

issn

1538-4667

journal_volume

29

pub_type

杂志文章
  • Evaluation of a tinnitus masking program: a follow-up study of 598 patients.

    abstract::A follow-up study of two groups of tinnitus patients was conducted in an attempt to evaluate the tinnitus masking program. Results are discussed separately for a group of patients seen during the first three years of the program (1976 through 1978) and during the last year (1979). These results suggest an improvement ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198003000-00004

    authors: Schleuning AJ,Johnson RM,Vernon JA

    更新日期:1980-03-01 00:00:00

  • Restoring Perceived Loudness for Listeners With Hearing Loss.

    abstract:OBJECTIVES:Normalizing perceived loudness is an important rationale for gain adjustments in hearing aids. It has been demonstrated that gains required for restoring normal loudness perception for monaural narrowband signals can lead to higher-than-normal loudness in listeners with hearing loss, particularly for binaura...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000521

    authors: Oetting D,Hohmann V,Appell JE,Kollmeier B,Ewert SD

    更新日期:2018-07-01 00:00:00

  • The effects of amplitude normalization and EMG targets on cVEMP interaural amplitude asymmetry.

    abstract:OBJECTIVES:The purpose of this investigation was to determine whether the use of visual feedback of tonic electromyographic (EMG) activity, or the use of amplitude normalization techniques would reduce significantly the variability in cervical vestibular evoked myogenic potential (cVEMP) P13-N23 interaural amplitude as...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31827ad792

    authors: McCaslin DL,Jacobson GP,Hatton K,Fowler AP,DeLong AP

    更新日期:2013-07-01 00:00:00

  • The Influence of Forced Social Isolation on the Auditory Ecology and Psychosocial Functions of Listeners With Cochlear Implants During COVID-19 Mitigation Efforts.

    abstract:OBJECTIVES:The impact of social distancing on communication and psychosocial variables among individuals with hearing impairment during COVID-19 pandemic. It was our concern that patients who already found themselves socially isolated (Wie et al. 2010) as a result of their hearing loss would be perhaps more susceptible...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000991

    authors: Dunn CC,Stangl E,Oleson J,Smith M,Chipara O,Wu YH

    更新日期:2020-12-22 00:00:00

  • Reversible sensorineural hearing loss in a stroke patient.

    abstract::A case is presented of a patient with lateral pontine stroke which resulted in a moderate unilateral sensorineural hearing loss. ABR, word recognition scores, acoustic reflexes, neurological evaluation, and CT scan were consistent with brain stem lesion. Recovery of hearing, including acoustic reflexes and word recogn...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Bales JD

    更新日期:1989-04-01 00:00:00

  • Event-related potentials in pediatric cochlear implant patients.

    abstract:OBJECTIVE:The main objective of this study was to assess the correlation of auditory event related potential (ERP) measures with behavioral assessment data to identify if ERPs including mismatch negativity (MMN) can be used to categorize cochlear implant patients into good and poor performers. DESIGN:We investigated a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200412000-00008

    authors: Singh S,Liasis A,Rajput K,Towell A,Luxon L

    更新日期:2004-12-01 00:00:00

  • Age-related asymmetry on a cued-listening task.

    abstract::We report results on a cued-listening task designed to simulate the listening problems commonly described by individuals with sensorineural hearing loss, especially those experienced by elderly persons. Against a background of multitalker babble, the subject detected targets embedded in continuous discourse. Noncohere...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199208000-00009

    authors: Jerger J,Jordan C

    更新日期:1992-08-01 00:00:00

  • Comparison of the Motor Performance and Vestibular Function in Infants with a Congenital Cytomegalovirus Infection or a Connexin 26 Mutation: A Preliminary Study.

    abstract:OBJECTIVES:Hearing-impaired children are at risk for vestibular damage and delayed motor development. Two major causes of congenital hearing loss are cytomegalovirus (CMV) infection and connexin (Cx) 26 mutations. Comparison of the motor performance and vestibular function between these specific groups is still underex...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000364

    authors: Maes L,De Kegel A,Van Waelvelde H,De Leenheer E,Van Hoecke H,Goderis J,Dhooge I

    更新日期:2017-01-01 00:00:00

  • Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.

    abstract:OBJECTIVES:The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000562

    authors: Blankenship CM,Hunter LL,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-11-01 00:00:00

  • Effects of Hearing Impairment and Hearing Aid Amplification on Listening Effort: A Systematic Review.

    abstract:OBJECTIVES:To undertake a systematic review of available evidence on the effect of hearing impairment and hearing aid amplification on listening effort. Two research questions were addressed: Q1) does hearing impairment affect listening effort? and Q2) can hearing aid amplification affect listening effort during speech...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000396

    authors: Ohlenforst B,Zekveld AA,Jansma EP,Wang Y,Naylor G,Lorens A,Lunner T,Kramer SE

    更新日期:2017-05-01 00:00:00

  • Tinnitus retraining therapy: mixing point and total masking are equally effective.

    abstract:OBJECTIVES:Habituation to tinnitus cannot occur with total masking, an argument made by proponents of "tinnitus retraining therapy." We also compared the effectiveness of retraining therapy with mixing-point masking, total masking, and with counseling alone. DESIGN:Forty-eight tinnitus patients were randomly assigned ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/AUD.0b013e31824f2a6e

    authors: Tyler RS,Noble W,Coelho CB,Ji H

    更新日期:2012-09-01 00:00:00

  • Test-retest reliability of a distinctive feature difference test for hearing aid evaluation.

    abstract::A short closed-set test of speech discrimination using consonants frequently confused by the hearing impaired and scored on the basis of distinctive features was developed and examined for reliability. In experiment I the Distinctive Feature Difference (DFD) Test and the CID W-22 Test were low-pass filtered and presen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198203000-00002

    authors: Feeney MP,Franks JR

    更新日期:1982-03-01 00:00:00

  • Cost-Effective Hearing Conservation: Regulatory and Research Priorities.

    abstract::Hearing conservation programs (HCPs) mandated by the US Occupational Safety and Health Administration (OSHA) cost about $350/worker/year. Are they cost-effective? A cross-sectional model of the US adult population with and without HCPs incorporates (1) the American Medical Association's method for estimating binaural ...

    journal_title:Ear and hearing

    pub_type: 社论

    doi:10.1097/AUD.0000000000000523

    authors: Dobie RA

    更新日期:2018-07-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Evaluation of four Spanish word-recognition-ability lists.

    abstract::Tests of word recognition ability (formerly Speech Discrimination) should be suitable for the linguistic background of the person being tested. Few efforts have been made to develop a standardized test in the Spanish language. Current literature reports on six studies that have several drawbacks. The purpose of the pr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198912000-00012

    authors: Weisleder P,Hodgson WR

    更新日期:1989-12-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Effect of electrode impedance on spread of excitation and pitch perception using electrically coupled "dual-electrode" stimulation.

    abstract:OBJECTIVES:In newer-generation Cochlear Ltd. cochlear implants, two adjacent electrodes can be electrically coupled to produce a single contact or "dual electrode" (DE). The goal of the present study was to evaluate whether relatively large impedance differences (>3.0 kOhms) between coupled electrodes affect the excita...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000098

    authors: Hughes ML,Baudhuin JL,Goehring JL

    更新日期:2015-03-01 00:00:00

  • Effects of stimulus level on the speech perception abilities of children using cochlear implants or digital hearing aids.

    abstract:OBJECTIVE:The present investigation was designed to provide information to facilitate the decision of whether a child should continue using digital signal processing (DSP) hearing aids with wide dynamic range compression (WDRC) or be recommended for a cochlear implant, based on the unaided pure-tone average (PTA at 500...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000234635.48564.ce

    authors: Davidson LS

    更新日期:2006-10-01 00:00:00

  • Auditory development reflected by middle latency response.

    abstract::The auditory middle latency response (MLR) seems to have a relatively long developmental time course, extending through the first decade of life. Characteristics of each MLR component change developmentally not only with respect to waveform morphology but also with respect to response reliability, dependence on awaren...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-199610000-00008

    authors: McGee T,Kraus N

    更新日期:1996-10-01 00:00:00

  • Hearing function in patients living with HIV/AIDS.

    abstract:OBJECTIVES:During the earlier years of the HIV/AIDS epidemic, initial reports described sensorineural hearing loss in up to 49% of individuals with HIV/AIDS. During those years, patients commonly progressed to advanced stages of HIV disease and frequently had neurological complications. However, the abnormalities on pu...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000064

    authors: Luque AE,Orlando MS,Leong UC,Allen PD,Guido JJ,Yang H,Wu H

    更新日期:2014-11-01 00:00:00

  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Evaluation of a localization training program for hearing impaired listeners.

    abstract:OBJECTIVE:To evaluate the effectiveness of a home-based and a laboratory-based localization training program. DESIGN:This study examined the effectiveness of a localization training program on improving the localization ability of 15 participants with a mild-to-moderately severe hearing loss. These participants had wo...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000067

    authors: Kuk F,Keenan DM,Lau C,Crose B,Schumacher J

    更新日期:2014-11-01 00:00:00

  • The efficiency of the single- versus multiple-stimulus auditory steady state responses in infants.

    abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e3181ff352c

    authors: Hatton J,Stapells DR

    更新日期:2011-05-01 00:00:00

  • Psychophysical performance and Mandarin tone recognition in noise by cochlear implant users.

    abstract:OBJECTIVE:The present study was aimed to examine the relationship between psychophysical performance in temporal and spectral resolution and Mandarin tone recognition in noise by cochlear-implant (CI) listeners. DESIGN:Seventeen Nucleus-24 implant users, 10 postlingually deafened and 7 prelingually deafened, participa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318031512c

    authors: Wei C,Cao K,Jin X,Chen X,Zeng FG

    更新日期:2007-04-01 00:00:00

  • The effect of otitis media with effusion at preschool age on some aspects of auditory perception at school age.

    abstract::The relationship between otitis media with effusion (OME) at preschool age and performance on five tests of auditory perception was studied in 89 school-age children who had OME histories well documented from participation in serial screening for OME at 2-4 yr of age. The tests used at 7.5-8 yr of age were: speech-in-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199406000-00003

    authors: Schilder AG,Snik AF,Straatman H,van den Broek P

    更新日期:1994-06-01 00:00:00

  • Reducing Simulated Channel Interaction Reveals Differences in Phoneme Identification Between Children and Adults With Normal Hearing.

    abstract:OBJECTIVES:Channel interaction, the stimulation of overlapping populations of auditory neurons by distinct cochlear implant (CI) channels, likely limits the speech perception performance of CI users. This study examined the role of vocoder-simulated channel interaction in the ability of children with normal hearing (cN...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000615

    authors: Jahn KN,DiNino M,Arenberg JG

    更新日期:2019-03-01 00:00:00

  • Relevance of Artifact Removal and Number of Stimuli for Video Head Impulse Test Examination.

    abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000849

    authors: Trinidad-Ruiz G,Rey-Martinez J,Matiño-Soler E,Batuecas-Caletrio A,Martin-Sanz E,Perez-Fernandez N

    更新日期:2020-09-01 00:00:00

  • Factors Predicting Postoperative Unilateral and Bilateral Speech Recognition in Adult Cochlear Implant Recipients with Acoustic Hearing.

    abstract:OBJECTIVES:The first objective was to examine factors that could be predictive of postoperative unilateral (cochlear implant alone) speech recognition ability in a group of subjects with greater degrees of preoperative acoustic hearing than has been previously examined. Second, the study aimed to identify factors predi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000233

    authors: Plant K,McDermott H,van Hoesel R,Dawson P,Cowan R

    更新日期:2016-03-01 00:00:00

  • Factors affecting sensitivity of distortion-product otoacoustic emissions to ototoxic hearing loss.

    abstract:OBJECTIVES:(1) To determine the ototoxicity detection rate (sensitivity) for distortion-product otoacoustic emissions (DPOAEs) testing in adults who received ototoxic medications and experienced pure-tone threshold changes during the course of treatment; (2) to determine the extent to which DPOAE sensitivity to ototoxi...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318181ad99

    authors: Reavis KM,Phillips DS,Fausti SA,Gordon JS,Helt WJ,Wilmington D,Bratt GW,Konrad-Martin D

    更新日期:2008-12-01 00:00:00