Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

Abstract:

OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity to binaural cues, which may explain the large localization errors seen in many patients. Previous work has shown that interaural place of stimulation mismatch can lead to off-centered auditory images being perceived even though interaural time and level differences (ITD and ILD, respectively) were zero. Large interaural mismatches reduced the ability to use ITDs for auditory image lateralization. In contrast, lateralization with ILDs was still possible but the mapping of ILDs to spatial locations was distorted. This study extends the previous work by systematically investigating the effect of interaural place of stimulation mismatch on ITD and ILD sensitivity directly and examining whether "centering" methods can be used to mitigate some of the negative effects of interaural place of stimulation mismatch. DESIGN:Interaural place of stimulation mismatch was deliberately introduced for this study. Interaural pitch-matching techniques were used to identify a pitch-matched pair of electrodes across the ears approximately at the center of the array. Mismatched pairs were then created by maintaining one of the pitch-matched electrodes constant, and systematically varying the contralateral electrode by two, four, or eight electrode positions (corresponding to approximately 1.5, 3, and 6 mm of interaural place of excitation differences). The stimuli were 300 msec, constant amplitude pulse trains presented at 100 pulses per second. ITD and ILD just noticeable differences (JNDs) were measured using a method of constant stimuli with a two-interval, two-alternative forced choice task. The results were fit with a psychometric function to obtain the JNDs. In experiment I, ITD and ILD JNDs were measured as a function of the simulated place of stimulation mismatch. In experiment II, the auditory image of mismatched pair was centered by adjusting the stimulation level according to a lateralization task. ITD and ILD JNDs were then remeasured and compared with the results of experiment I. RESULTS:ITD and ILD JNDs were best (lowest thresholds) for pairs of electrodes at or near the pitch-matched pair. Thresholds increased systematically with increasing amounts of interaural mismatch. Deliberate and careful centering of auditory images did not significantly improve ITD JNDs but did improve ILD JNDs at very large amounts of simulated mismatch. CONCLUSIONS:Interaural place of stimulation mismatch decreases sensitivity to binaural cues that are important for accurate sound localization. However, deliberate and careful centering of auditory images does not seem to significantly counteract the effects of mismatch. Hence, to obtain maximal sound localization benefits of bilateral implantation, clinical and surgical techniques are needed that take into account differences in electrode array insertion depths across the ears.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Kan A,Litovsky RY,Goupell MJ

doi

10.1097/AUD.0000000000000135

subject

Has Abstract

pub_date

2015-05-01 00:00:00

pages

e62-8

issue

3

eissn

0196-0202

issn

1538-4667

journal_volume

36

pub_type

杂志文章
  • Effects of channel-to-electrode mappings on speech reception with the ineraid cochlear implant.

    abstract:OBJECTIVE:Research was conducted to assess multichannel saliency with the Ineraid cochlear prosthesis. The goal was to determine whether tonotopically ordered stimulation benefits speech reception. DESIGN:In a single high-performing subject, changes in speech reception were studied during two dramatic alterations to t...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199510000-00002

    authors: Rabinowitz WM,Eddington DK

    更新日期:1995-10-01 00:00:00

  • Evaluation of Speed and Accuracy of Next-Generation Auditory Steady State Response and Auditory Brainstem Response Audiometry in Children With Normal Hearing and Hearing Loss.

    abstract:OBJECTIVES:The first objective of this study was to compare the predicted audiometric thresholds obtained by auditory steady state response (ASSR) and auditory brainstem response (ABR) in infants and toddlers when both techniques use optimal stimuli and detection algorithms. This information will aid in determining the...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/AUD.0000000000000580

    authors: Sininger YS,Hunter LL,Hayes D,Roush PA,Uhler KM

    更新日期:2018-11-01 00:00:00

  • Identification, assessment, and management of children with unilateral sensorineural hearing loss.

    abstract::Because some unilaterally hearing-impaired children appear to experience difficulty in communication and educational progress, it seems only appropriate to reassess the identification and management strategies that are used with these children. Accordingly, this paper presents some general information on identificatio...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198602000-00008

    authors: Bess FH,Klee T,Culbertson JL

    更新日期:1986-02-01 00:00:00

  • The influence of nonaudiological variables on audiological rehabilitation outcomes.

    abstract::The link between nonaudiological variables and outcomes measurement is explored. Hearing impairment can affect an individual's everyday communication in numerous ways. Both audiological and nonaudiological variables interact with each other to produce a unique predicament for each individual with hearing impairment. T...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200008001-00003

    authors: Kricos PB

    更新日期:2000-08-01 00:00:00

  • Ocular and cervical vestibular-evoked myogenic potentials: a study to determine whether air- or bone-conducted stimuli are optimal.

    abstract:OBJECTIVES:The aim of this study was to determine whether bone-conducted vibration (BCV) or air-conducted sound (ACS) is the optimal mode for eliciting both ocular vestibular-evoked myogenic potentials (oVEMPs) and cervical VEMPs (cVEMPs). DESIGN:Twelve healthy volunteers, five patients with unilateral chronic otitis ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/AUD.0b013e3181bdbac0

    authors: Wang SJ,Weng WJ,Jaw FS,Young YH

    更新日期:2010-04-01 00:00:00

  • Exploring the role of the modulation spectrum in phoneme recognition.

    abstract:OBJECTIVES:The ability of human listeners to identify consonants (presented as nonsense syllables) on the basis of primarily temporal information was compared with the predictions of a simple model based on the amplitude modulation spectra of the stimuli calculated for six octave-spaced carrier frequencies (250 to 8000...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31817e73ef

    authors: Gallun F,Souza P

    更新日期:2008-10-01 00:00:00

  • Using Thresholds in Noise to Identify Hidden Hearing Loss in Humans.

    abstract:OBJECTIVES:Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resist...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000543

    authors: Ridley CL,Kopun JG,Neely ST,Gorga MP,Rasetshwane DM

    更新日期:2018-09-01 00:00:00

  • Consonant recognition and confusion patterns among elderly hearing-impaired subjects.

    abstract::This study investigated whether unique consonant recognition and confusion patterns are associated with hearing loss among elderly listeners. Subjects were all greater than 65 years, and had normal hearing, or gradually or sharply sloping sensorineural hearing losses. Recognition of 19 consonants, paired with each of ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198710000-00003

    authors: Gordon-Salant S

    更新日期:1987-10-01 00:00:00

  • Speech recognition ability of children with unilateral sensorineural hearing loss as a function of amplification, speech stimuli and listening condition.

    abstract::The purpose of this investigation was to examine three types of audiological recommendations [unaided, CROS (contralateral routing of signals) and personal FM system] and their impact upon speech recognition ability of children with unilateral sensorineural hearing loss. Each of these recommendations was tested under ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199008000-00003

    authors: Kenworthy OT,Klee T,Tharpe AM

    更新日期:1990-08-01 00:00:00

  • Chronic Conductive Hearing Loss Is Associated With Speech Intelligibility Deficits in Patients With Normal Bone Conduction Thresholds.

    abstract:OBJECTIVES:The main objective of this study is to determine whether chronic sound deprivation leads to poorer speech discrimination in humans. DESIGN:We reviewed the audiologic profile of 240 patients presenting normal and symmetrical bone conduction thresholds bilaterally, associated with either an acute or chronic u...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000787

    authors: Okada M,Welling DB,Liberman MC,Maison SF

    更新日期:2020-05-01 00:00:00

  • Predictive properties of the video head impulse test: measures of caloric symmetry and self-report dizziness handicap.

    abstract:OBJECTIVES:The purpose of this investigation was to determine whether a predictable relationship existed between self-reported dizziness handicap and video Head Impulse Test (vHIT) results in a large sample of patients reporting to a dizziness clinic. Secondary objectives included describing the characteristics of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000047

    authors: McCaslin DL,Jacobson GP,Bennett ML,Gruenwald JM,Green AP

    更新日期:2014-09-01 00:00:00

  • Psychophysiological therapy for tinnitus.

    abstract::Twenty-two patients with complaints of severe tinnitus received psychophysiological therapy. Biofeedback sessions were supplemented with body relaxation techniques through the use of audio cassette tapes. The experimental group was matched to a control group according to age and sex. The individuals' names in the cont...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198612000-00009

    authors: White TP,Hoffman SR,Gale EN

    更新日期:1986-12-01 00:00:00

  • Hearing handicap ratings among different profiles of adult cochlear implant users.

    abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31815d6da8

    authors: Noble W,Tyler R,Dunn C,Bhullar N

    更新日期:2008-01-01 00:00:00

  • Features from normal and sensorineural listeners' nonsense syllable test errors.

    abstract::Identification errors for initial consonants of consonants-vowels-consonants-vowels from lists A and B of the Nonsense Syllable Test were analyzed for 10 normal-hearing and 8 sensorineural hearing-impaired listeners. The Nonsense Syllable Test stimuli were presented binaurally through earphones at 6 increasing sensati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198105000-00006

    authors: Doyle KJ,Danhauer JL,Edgerton BJ

    更新日期:1981-05-01 00:00:00

  • Validating a Method to Assess Lipreading, Audiovisual Gain, and Integration During Speech Reception With Cochlear-Implanted and Normal-Hearing Subjects Using a Talking Head.

    abstract:OBJECTIVES:Watching a talker's mouth is beneficial for speech reception (SR) in many communication settings, especially in noise and when hearing is impaired. Measures for audiovisual (AV) SR can be valuable in the framework of diagnosing or treating hearing disorders. This study addresses the lack of standardized meth...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000502

    authors: Schreitmüller S,Frenken M,Bentz L,Ortmann M,Walger M,Meister H

    更新日期:2018-05-01 00:00:00

  • Acoustic radiation produced by B-71, B-72, and KH 70 bone vibrators.

    abstract::The amount of acoustic radiation produced by two samples of a Radioear B-71, B-72, and Pracitronic KH 70 bone vibrator was determined for 30 normal-hearing subjects at 4000 Hz. The mean amount of acoustic radiation was very similar for both samples of each vibrator type but significantly (p less than 0.05) different b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198610000-00010

    authors: Frank T,Crandell CC

    更新日期:1986-10-01 00:00:00

  • Noise levels in physicians' offices.

    abstract::The development of hand-held auditory screening devices has led to increased hearing screening by physicians. Ambient noise levels were assessed in examination rooms of 20 physician offices. Measurements provided Ln, Leq, Lmax, and octave band data for specialty types: pediatrics, internal medicine, family practice an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00012

    authors: Alvord LS

    更新日期:1990-10-01 00:00:00

  • Changes in transient-evoked otoacoustic emissions in the first month of life.

    abstract:OBJECTIVE:Current Joint Committee on Infant Hearing guidelines recommend the use of transient-evoked otoacoustic emissions (TEOAEs) as a screening tool to identify hearing loss for newborns cared for in the well-baby nursery. Newborns who do not pass the TEOAE screen before leaving the hospital are typically rescreened...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31819c4000

    authors: Prieve BA,Hancur-Bucci CA,Preston JL

    更新日期:2009-06-01 00:00:00

  • Perceptual benefit and functional outcomes for children using sequential bilateral cochlear implants.

    abstract:OBJECTIVE:To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. DESIGN:A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 1...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31806dc194

    authors: Galvin KL,Mok M,Dowell RC

    更新日期:2007-08-01 00:00:00

  • Callsign Acquisition Test (CAT): speech intelligibility in noise.

    abstract:OBJECTIVE:The study was designed to assess the effects of noise on the intelligibility of speech elements used in the Callsign Acquisition Test (CAT), developed by the U.S. Army Research Laboratory. The CAT consists of 126 test items, or callsigns, each of which is made up of a two-syllable word selected from the 18-it...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000202289.32228.f6

    authors: Rao MD,Letowski T

    更新日期:2006-04-01 00:00:00

  • The Relation Between Child Versus Parent Report of Chronic Fatigue and Language/Literacy Skills in School-Age Children with Cochlear Implants.

    abstract:OBJECTIVES:Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits i...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000242

    authors: Werfel KL,Hendricks AE

    更新日期:2016-03-01 00:00:00

  • Use of test-retest measures to evaluate performance stability in adults with cochlear implants.

    abstract:OBJECTIVE:This study was designed to evaluate performance stability with test-retest measures of electrical thresholds, electrical maximum acceptable loudness levels, sound-field thresholds, and audition-only speech tests. The hypothesis was that the standard error of measurement differs from one individual to another ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199504000-00006

    authors: Skinner MW,Holden LK,Demorest ME,Holden TA

    更新日期:1995-04-01 00:00:00

  • Hormonal influence on auditory function.

    abstract::This study examined whether female subjects who had balanced hormonal profiles and who were experiencing the characteristic fluctuation in estrogen and progesterone levels exhibited changes in auditory function unlike subjects who were using a low-dose combined estrogen and progesterone steroid. Threshold data at 500,...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198007000-00008

    authors: Cox JR

    更新日期:1980-07-01 00:00:00

  • Auditory steady state cortical responses indicate deviant phonemic-rate processing in adults with dyslexia.

    abstract:OBJECTIVES:Speech intelligibility is strongly influenced by the ability to process temporal modulations. It is hypothesized that in dyslexia, deficient processing of rapidly changing auditory information underlies a deficient development of phonological representations, causing reading and spelling problems. Low-freque...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31822c26b9

    authors: Poelmans H,Luts H,Vandermosten M,Boets B,Ghesquière P,Wouters J

    更新日期:2012-01-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Hearing aid patients in private practice and public health (Veterans Affairs) clinics: are they different?

    abstract:OBJECTIVE:In hearing aid research, it is commonplace to combine data across subjects whose hearing aids were provided in different service delivery models. There is reason to question whether these types of patients are always similar enough to justify this practice. To explore this matter, this investigation evaluated...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/01.aud.0000188188.01311.0b

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2005-12-01 00:00:00

  • How Do You Deal With Uncertainty? Cochlear Implant Users Differ in the Dynamics of Lexical Processing of Noncanonical Inputs.

    abstract:OBJECTIVES:Work in normal-hearing (NH) adults suggests that spoken language processing involves coping with ambiguity. Even a clearly spoken word contains brief periods of ambiguity as it unfolds over time, and early portions will not be sufficient to uniquely identify the word. However, beyond this temporary ambiguity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000681

    authors: McMurray B,Ellis TP,Apfelbaum KS

    更新日期:2019-07-01 00:00:00

  • Effects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.

    abstract:OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measur...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000090340.09847.39

    authors: Donaldson GS,Allen SL

    更新日期:2003-10-01 00:00:00

  • Longitudinal Development of Distortion Product Otoacoustic Emissions in Infants With Normal Hearing.

    abstract:OBJECTIVES:The purpose of this study was to describe normal characteristics of distortion product otoacoustic emission (DPOAE) signal and noise level in a group of newborns and infants with normal hearing followed longitudinally from birth to 15 months of age. DESIGN:This is a prospective, longitudinal study of 231 in...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000542

    authors: Hunter LL,Blankenship CM,Keefe DH,Feeney MP,Brown DK,McCune A,Fitzpatrick DF,Lin L

    更新日期:2018-09-01 00:00:00

  • The efficiency of the single- versus multiple-stimulus auditory steady state responses in infants.

    abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e3181ff352c

    authors: Hatton J,Stapells DR

    更新日期:2011-05-01 00:00:00