Abstract:
OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measured by sound field thresholds. It was hypothesized that speech recognition performance in both Nucleus SPEAK and Clarion CIS participants would decrease as presentation level was decreased below 50 to 60 dBA, due to audibility limitations. However, it was expected that such level effects would be less severe in CIS participants than in SPEAK participants because the Clarion v1.2 device encodes a wider acoustic dynamic range (up to 60 dB) than the Nucleus 22 device (30 dB). DESIGN:Performance-intensity (P-I) functions for vowels, consonants and sentences in quiet were obtained from each participant. P-I functions incorporated speech levels of 70, 60, 50, 40 and 30 dBA. Subjects used their clinical speech processor maps and adjusted the loudness (volume/sensitivity) controls on their processors so that speech presented at 60 dBA was comfortably loud. Maps were created using default clinical procedures and were not adjusted to optimize sound field thresholds. Sound field thresholds and dynamic ranges were measured for warbled pure tones with frequencies of 250 to 6000 Hz. RESULTS:Consonant and sentence recognition showed strong level effects for both SPEAK and CIS participants, with performance decreasing substantially at levels below 50 dBA in most individuals. Vowel recognition showed weaker level effects. For all three speech materials, SPEAK and CIS participants demonstrated similar mean performance at 70 dBA; however, SPEAK participants showed larger reductions in performance than CIS participants with decreasing level. Sound field thresholds were more sensitive for CIS participants than for SPEAK participants, supporting the hypothesis that performance differences were related to audibility. CONCLUSIONS:Cochlear implant listeners are unable to maintain good speech recognition at low presentation levels due to reduced stimulus audibility, and this may significantly limit their ability to communicate in daily life. It is likely that audibility differences between SPEAK and CIS participants in the present study can be attributed at least partly to differences in the acoustic dynamic range used by the respective processors. However, several additional factors may have contributed to differences in audibility and perception of soft speech among individual listeners with both devices. These include the minimum and maximum electrical stimulation levels specified in participants' maps and the speech processor sensitivity setting used for testing.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Donaldson GS,Allen SLdoi
10.1097/01.AUD.0000090340.09847.39subject
Has Abstractpub_date
2003-10-01 00:00:00pages
392-405issue
5eissn
0196-0202issn
1538-4667pii
00003446-200310000-00005journal_volume
24pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVE:To evaluate the effectiveness of a home-based and a laboratory-based localization training program. DESIGN:This study examined the effectiveness of a localization training program on improving the localization ability of 15 participants with a mild-to-moderately severe hearing loss. These participants had wo...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0000000000000067
更新日期:2014-11-01 00:00:00
abstract:OBJECTIVES:This study aimed to characterize horizontal plane sound localization in interfering noise at different signal-to-noise ratios (SNRs) and to compare performance across normal-hearing listeners and users of unilateral and bilateral cochlear implants (CIs). CI users report difficulties with listening in noisy e...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e318257607b
更新日期:2012-07-01 00:00:00
abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199910000-00001
更新日期:1999-10-01 00:00:00
abstract:OBJECTIVES:To undertake a systematic review of available evidence on the effect of hearing impairment and hearing aid amplification on listening effort. Two research questions were addressed: Q1) does hearing impairment affect listening effort? and Q2) can hearing aid amplification affect listening effort during speech...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/AUD.0000000000000396
更新日期:2017-05-01 00:00:00
abstract::Elderly individuals often have more deficits in speech understanding than would be expected in younger individuals with the same degree of hearing loss. Such deficits may be attributed to the complex nature of age-related changes that occur throughout the central auditory nervous system and are generally referred to a...
journal_title:Ear and hearing
pub_type: 杂志文章,评审
doi:10.1097/00003446-199112001-00007
更新日期:1991-12-01 00:00:00
abstract:OBJECTIVES:Temporal envelope and periodicity components (TEPC) in the speech signal have potentials to offer important cues for speech recognition especially in tonal languages. The aims of this study are: (i) to investigate the degree of contributions of TEPC to lexical tone identification in Cantonese; and (ii) to in...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31803153ac
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000135
更新日期:2015-05-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to characterize auditory function in patients diagnosed with post-treatment Lyme disease syndrome (PTLDS). DESIGN:Eighteen patients with PTLDS were evaluated and compared to a normal population. Evaluations consisted of pure tone and speech thresholds, word recognition (WRS), ac...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.AUD.0000100205.25774.5F
更新日期:2003-12-01 00:00:00
abstract:OBJECTIVE:To compare the performance of cochlear implant patients and normal-hearing subjects on a musical interval labeling task, and to determine whether information regarding musical interval size is available to cochlear implant patients under realistic everyday listening conditions. DESIGN:Two Nucleus cochlear im...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199710000-00002
更新日期:1997-10-01 00:00:00
abstract::Errors on a nonsense syllable test (NST) were compared to pure-tone thresholds and ages of 109 subjects with normal or sensorineural hearing loss. A strong correlation was found between the number of NST errors and hearing loss at 2000 and 250 Hz. NST errors do not appear to be related to the age of subjects. Excellen...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198702000-00008
更新日期:1987-02-01 00:00:00
abstract:OBJECTIVES:(1) To present hearing threshold data from a recent nationally representative survey in the United States (National Health and Nutrition Examination Survey, 1999-2004) in a distributional format that might be appropriate to replace Annex B in international (ISO-1999) and national (ANSI S3.44) standards and (...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e3181e9770e
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVE:A new speech processing concept and its implementation cochlear implant neural net, simulation and stimulation (CINSTIM), for cochlear implant systems is currently under investigation. The main objectives of this new strategy are to improve speech perception within the early rehabilitation period for prelingu...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199602000-00009
更新日期:1996-02-01 00:00:00
abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000345
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVES:Early-deafened, late-implanted adolescents and adults constitute a unique group of cochlear implant (CI) users, showing a large variability in outcomes. The current systematic review aimed to determine which preimplantation factors are relevant in predicting postoperative outcomes in this patient group. DES...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000889
更新日期:2020-11-01 00:00:00
abstract::We report results on a cued-listening task designed to simulate the listening problems commonly described by individuals with sensorineural hearing loss, especially those experienced by elderly persons. Against a background of multitalker babble, the subject detected targets embedded in continuous discourse. Noncohere...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199208000-00009
更新日期:1992-08-01 00:00:00
abstract:OBJECTIVES:Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the comp...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e318177d9c6
更新日期:2008-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare binaural performance of auditory localization task and speech perception in babble measure between children who use a cochlear implant (CI) in one ear and a hearing aid (HA) in the other (bimodal fitting) and those who use bilateral CIs. DESIGN:Thirteen children (mean ag...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000401
更新日期:2017-07-01 00:00:00
abstract::The ability to remove cochlear implants from children and subsequently reimplant a more complex device in the same ear was the concern of this single case study. A postlinguistically deafened child, J.L., received a single-channel cochlear implant 1 yr after contracting meningitis and suffering a profound bilateral se...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199206000-00009
更新日期:1992-06-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to examine the relationship between noise exposure history, type 1 diabetes mellitus (DM), and suprathreshold measures of auditory function. DESIGN:A cross-sectional study was conducted; 20 normal-hearing participants without type 1 DM were matched on age and sex to 20 normal-h...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000457
更新日期:2017-11-01 00:00:00
abstract:OBJECTIVES:In newer-generation Cochlear Ltd. cochlear implants, two adjacent electrodes can be electrically coupled to produce a single contact or "dual electrode" (DE). The goal of the present study was to evaluate whether relatively large impedance differences (>3.0 kOhms) between coupled electrodes affect the excita...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000098
更新日期:2015-03-01 00:00:00
abstract:OBJECTIVES:Diet may affect susceptibility of the inner ear to noise and age-related effects that lead to tinnitus and hearing loss. This study used complementary single nutrient and dietary pattern analysis based on statistical grouping of usual dietary intake in a cross-sectional analysis of tinnitus and hearing diffi...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000765
更新日期:2020-03-01 00:00:00
abstract:OBJECTIVE:The aim was to compare outcomes in the domain of self-reported hearing handicap across groups of patients fit with one versus two cochlear implants (CI, CI + CI), or with an implant and a hearing aid (HA) in the nonimplanted ear (CI + HA). DESIGN:The design was retrospective, and a preliminary step was to fa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31815d6da8
更新日期:2008-01-01 00:00:00
abstract:OBJECTIVES:Cochlear implant (CI) users suffer from a range of speech impairments, such as stuttering and vocal control of pitch and intensity. Though little research has focused on the role of auditory feedback in the speech of CI users, these speech impairments could be due in part to limited access to low-frequency c...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000690
更新日期:2019-09-01 00:00:00
abstract:OBJECTIVES:Here, we evaluate the risks of amplified music for disc-jockeys (DJs) working in nightclubs. DESIGN:Sound level measurements were performed within the DJ mixing booths. A questionnaire was used to obtain exposure to noise and length of time in the profession. Audiograms and tinnitus pitch matching was also ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31819769fc
更新日期:2009-04-01 00:00:00
abstract:OBJECTIVES:To examine differences in family environment and associations between family environment and key speech, language, and cognitive outcomes in samples of children with normal hearing and deaf and hard-of-hearing (DHH) children who use hearing aids and cochlear implants. DESIGN:Thirty families of children with...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000811
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:The purpose of this investigation was to determine whether the use of visual feedback of tonic electromyographic (EMG) activity, or the use of amplitude normalization techniques would reduce significantly the variability in cervical vestibular evoked myogenic potential (cVEMP) P13-N23 interaural amplitude as...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31827ad792
更新日期:2013-07-01 00:00:00
abstract::This study examined whether female subjects who had balanced hormonal profiles and who were experiencing the characteristic fluctuation in estrogen and progesterone levels exhibited changes in auditory function unlike subjects who were using a low-dose combined estrogen and progesterone steroid. Threshold data at 500,...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198007000-00008
更新日期:1980-07-01 00:00:00
abstract:OBJECTIVES:Diabetes mellitus (DM) is associated with a variety of sensory complications. Very little attention has been given to auditory neuropathic complications in DM. The aim of this study was to determine whether type 1 DM (T1DM) affects neural coding of the rapid temporal fluctuations of sounds, and how any defic...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000781
更新日期:2020-05-01 00:00:00
abstract:OBJECTIVES:Preliminary evidence suggests that children with hearing loss experience elevated levels of chronic fatigue compared with children with normal hearing. Chronic fatigue is associated with decreased academic performance in many clinical populations. Children with cochlear implants as a group exhibit deficits i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000242
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effe...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000380
更新日期:2017-03-01 00:00:00