How Do You Deal With Uncertainty? Cochlear Implant Users Differ in the Dynamics of Lexical Processing of Noncanonical Inputs.

Abstract:

OBJECTIVES:Work in normal-hearing (NH) adults suggests that spoken language processing involves coping with ambiguity. Even a clearly spoken word contains brief periods of ambiguity as it unfolds over time, and early portions will not be sufficient to uniquely identify the word. However, beyond this temporary ambiguity, NH listeners must also cope with the loss of information due to reduced forms, dialect, and other factors. A recent study suggests that NH listeners may adapt to increased ambiguity by changing the dynamics of how they commit to candidates at a lexical level. Cochlear implant (CI) users must also frequently deal with highly degraded input, in which there is less information available in the input to recover a target word. The authors asked here whether their frequent experience with this leads to lexical dynamics that are better suited for coping with uncertainty. DESIGN:Listeners heard words either correctly pronounced (dog) or mispronounced at onset (gog) or offset (dob). Listeners selected the corresponding picture from a screen containing pictures of the target and three unrelated items. While they did this, fixations to each object were tracked as a measure of the time course of identifying the target. The authors tested 44 postlingually deafened adult CI users in 2 groups (23 used standard electric only configurations, and 21 supplemented the CI with a hearing aid), along with 28 age-matched age-typical hearing (ATH) controls. RESULTS:All three groups recognized the target word accurately, though each showed a small decrement for mispronounced forms (larger in both types of CI users). Analysis of fixations showed a close time locking to the timing of the mispronunciation. Onset mispronunciations delayed initial fixations to the target, but fixations to the target showed partial recovery by the end of the trial. Offset mispronunciations showed no effect early, but suppressed looking later. This pattern was attested in all three groups, though both types of CI users were slower and did not commit fully to the target. When the authors quantified the degree of disruption (by the mispronounced forms), they found that both groups of CI users showed less disruption than ATH listeners during the first 900 msec of processing. Finally, an individual differences analysis showed that within the CI users, the dynamics of fixations predicted speech perception outcomes over and above accuracy in this task and that CI users with the more rapid fixation patterns of ATH listeners showed better outcomes. CONCLUSIONS:Postlingually deafened CI users process speech incrementally (as do ATH listeners), though they commit more slowly and less strongly to a single item than do ATH listeners. This may allow them to cope more flexible with mispronunciations.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

McMurray B,Ellis TP,Apfelbaum KS

doi

10.1097/AUD.0000000000000681

subject

Has Abstract

pub_date

2019-07-01 00:00:00

pages

961-980

issue

4

eissn

0196-0202

issn

1538-4667

journal_volume

40

pub_type

杂志文章
  • Validating a Method to Assess Lipreading, Audiovisual Gain, and Integration During Speech Reception With Cochlear-Implanted and Normal-Hearing Subjects Using a Talking Head.

    abstract:OBJECTIVES:Watching a talker's mouth is beneficial for speech reception (SR) in many communication settings, especially in noise and when hearing is impaired. Measures for audiovisual (AV) SR can be valuable in the framework of diagnosing or treating hearing disorders. This study addresses the lack of standardized meth...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000502

    authors: Schreitmüller S,Frenken M,Bentz L,Ortmann M,Walger M,Meister H

    更新日期:2018-05-01 00:00:00

  • Vestibular Function Modulates the Benefit of Hearing Aids in People With Hearing Loss During Static Postural Control.

    abstract:OBJECTIVES:To evaluate the influence of auditory cues on postural sway in normal-hearing (NH) individuals, hearing-impaired individuals with vestibular impairment (HIVL), or hearing-impaired (HI) individuals without vestibular impairment. DESIGN:Thirty-two participants received a hearing and a vestibular evaluation (v...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000720

    authors: Maheu M,Behtani L,Nooristani M,Houde MS,Delcenserie A,Leroux T,Champoux F

    更新日期:2019-11-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • Audiovisual integration and lipreading abilities of older adults with normal and impaired hearing.

    abstract:OBJECTIVE:The purpose of the current study was to examine how age-related hearing impairment affects lipreading and auditory-visual integration. The working hypothesis for the investigation was that presbycusic hearing loss would increase reliance on visual speech information, resulting in better lipreading and auditor...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31812f7185

    authors: Tye-Murray N,Sommers MS,Spehar B

    更新日期:2007-09-01 00:00:00

  • Deaf children's processing of auditory, visual, and combined stimuli.

    abstract::One hundred eighty-four deaf children were presented auditory, visual (speechreading), and combined stimuli. Some subjects showed an enhancement of their processing abilities in the combined mode, some demonstrated no improvement, and others yielded reduced scores. A method of data analysis is proposed which could con...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198005000-00003

    authors: Holmes DW,Groccia B,Johnson K,Green W

    更新日期:1980-05-01 00:00:00

  • Sensory-Cognitive Interactions in Older Adults.

    abstract::The objective of this study was regarding sensory and cognitive interactions in older adults published since 2009, the approximate date of the most recent reviews on this topic. After an electronic database search of articles published in English since 2009 on measures of hearing and cognition or vision and cognition ...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000303

    authors: Humes LE,Young LA

    更新日期:2016-07-01 00:00:00

  • Clinical findings for a group of infants and young children with auditory neuropathy.

    abstract:OBJECTIVE:To examine the prevalence of auditory neuropathy in a group of infants at risk for hearing impairment and to present an overview of the clinical findings for affected children. DESIGN:Results for 20 subjects who showed repeatable cochlear microphonic potentials in the absence of click-evoked auditory brain s...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199906000-00006

    authors: Rance G,Beer DE,Cone-Wesson B,Shepherd RK,Dowell RC,King AM,Rickards FW,Clark GM

    更新日期:1999-06-01 00:00:00

  • Americans hear as well or better today compared with 40 years ago: hearing threshold levels in the unscreened adult population of the United States, 1959-1962 and 1999-2004.

    abstract:OBJECTIVES:(1) To present hearing threshold data from a recent nationally representative survey in the United States (National Health and Nutrition Examination Survey, 1999-2004) in a distributional format that might be appropriate to replace Annex B in international (ISO-1999) and national (ANSI S3.44) standards and (...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e9770e

    authors: Hoffman HJ,Dobie RA,Ko CW,Themann CL,Murphy WJ

    更新日期:2010-12-01 00:00:00

  • Use of Direct-Connect for Remote Speech-Perception Testing in Cochlear Implants.

    abstract:OBJECTIVES:Previous research has demonstrated the feasibility of programming cochlear implants (CIs) via telepractice. To effectively use telepractice in a comprehensive manner, all components of a clinical CI visit should be validated using remote technology. Speech-perception testing is important for monitoring outco...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000693

    authors: Sevier JD,Choi S,Hughes ML

    更新日期:2019-09-01 00:00:00

  • Speech recognition performance of patients with sensorineural hearing loss under unaided and aided conditions using linear and compression hearing AIDS.

    abstract:OBJECTIVES:This study compared speech recognition performance on the Northwestern University Auditory Test No. 6 (NU-6) and the Connected Speech Test (CST) for three hearing aid circuits (peak clipping [PC], compression limiting [CL], and wide dynamic range compression [WDRC]) in adults with symmetrical sensorineural h...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200208000-00003

    authors: Shanks JE,Wilson RH,Larson V,Williams D

    更新日期:2002-08-01 00:00:00

  • Hearing deficits correlated with the timing of systemic disturbance as indicated by primary incisor defects.

    abstract::A correlation of hearing deficits and enamel defects was investigated in 18 children presenting to a pediatric neurology service for hearing evaluation. Eleven had enamel defects. Five had defects consistent with a systemic insult occurring as early as 14 weeks gestation, two between 29 to 33 weeks gestation, and four...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198509000-00006

    authors: Murray GS,Johnsen DC

    更新日期:1985-09-01 00:00:00

  • The measurement of performance asymmetries with dichotic stimulus presentation.

    abstract::The failure to include only relevant observations in the assessment of laterality has resulted in a proliferation of post hoc attempts to "correct" laterality measures influenced by "overall performance level." The inclusion of information from trials in which both ears were either correct or in error contaminates the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198405000-00010

    authors: Hughes LF,Miller CJ

    更新日期:1984-05-01 00:00:00

  • Cost-Effective Hearing Conservation: Regulatory and Research Priorities.

    abstract::Hearing conservation programs (HCPs) mandated by the US Occupational Safety and Health Administration (OSHA) cost about $350/worker/year. Are they cost-effective? A cross-sectional model of the US adult population with and without HCPs incorporates (1) the American Medical Association's method for estimating binaural ...

    journal_title:Ear and hearing

    pub_type: 社论

    doi:10.1097/AUD.0000000000000523

    authors: Dobie RA

    更新日期:2018-07-01 00:00:00

  • Distortion product otoacoustic emission response characteristics in older adults.

    abstract:OBJECTIVE:The primary purpose of this study was to determine the distortion product otoacoustic emission (DPOAE) and noise response characteristics in a large sample of older adults. Another purpose was to evaluate how specific absolute DPOAE levels or DPOAE/Noise ratios differentiated hearing status in these individua...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000051847.66944.2B

    authors: Torre P 3rd,Cruickshanks KJ,Nondahl DM,Wiley TL

    更新日期:2003-02-01 00:00:00

  • The effect of reference microphone placement on sound pressure levels at an ear level hearing aid microphone.

    abstract::The present study was designed to investigate the effects of reference microphone location on probe tube microphone measures of hearing aid response. The reference microphone of a clinical probe tube microphone system was located either at a position on the cheek (position A) or in close proximity to the microphone of...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00001

    authors: Feigin JA,Barlow NL,Stelmachowicz PG

    更新日期:1990-10-01 00:00:00

  • Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    abstract:OBJECTIVES:A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. I...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000463

    authors: Landsberger DM,Padilla M,Martinez AS,Eisenberg LS

    更新日期:2018-01-01 00:00:00

  • Qualities of Single Electrode Stimulation as a Function of Rate and Place of Stimulation with a Cochlear Implant.

    abstract:OBJECTIVES:Although it has been shown previously that changes in temporal coding produce changes in pitch in all cochlear regions, research has suggested that temporal coding might be best encoded in relatively apical locations. The authors hypothesized that although temporal coding may provide useable information at a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000250

    authors: Landsberger DM,Vermeire K,Claes A,Van Rompaey V,Van de Heyning P

    更新日期:2016-05-01 00:00:00

  • Longitudinal study of pure-tone thresholds in older persons.

    abstract:OBJECTIVE:Pure-tone thresholds for conventional and extended high frequencies were analyzed for 188 older adult human subjects (91 females, 97 males). The objectives were to study longitudinal changes in thresholds as well as the effects of initial threshold levels, age, gender, and noise history on these longitudinal ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200502000-00001

    authors: Lee FS,Matthews LJ,Dubno JR,Mills JH

    更新日期:2005-02-01 00:00:00

  • Relevance of Artifact Removal and Number of Stimuli for Video Head Impulse Test Examination.

    abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000849

    authors: Trinidad-Ruiz G,Rey-Martinez J,Matiño-Soler E,Batuecas-Caletrio A,Martin-Sanz E,Perez-Fernandez N

    更新日期:2020-09-01 00:00:00

  • Cochlear implantation in children with auditory neuropathy spectrum disorder.

    abstract:OBJECTIVE:To report the patient's characteristics, preoperative audiological profiles, surgical outcomes, and postoperative performance for children with auditory neuropathy spectrum disorder (ANSD) who ultimately received cochlear implants (CIs). DESIGN:Prospective, longitudinal study of children with ANSD who receiv...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181ce693b

    authors: Teagle HF,Roush PA,Woodard JS,Hatch DR,Zdanski CJ,Buss E,Buchman CA

    更新日期:2010-06-01 00:00:00

  • The effect of otitis media with effusion at preschool age on some aspects of auditory perception at school age.

    abstract::The relationship between otitis media with effusion (OME) at preschool age and performance on five tests of auditory perception was studied in 89 school-age children who had OME histories well documented from participation in serial screening for OME at 2-4 yr of age. The tests used at 7.5-8 yr of age were: speech-in-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199406000-00003

    authors: Schilder AG,Snik AF,Straatman H,van den Broek P

    更新日期:1994-06-01 00:00:00

  • Real ear attenuation at threshold for three audiometric headphone devices: implications for maximum permissible ambient noise level standards.

    abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199202000-00004

    authors: Franks JR,Engel DP 3rd,Themann CL

    更新日期:1992-02-01 00:00:00

  • On the behavioral characteristics of loud-music listening.

    abstract::To provide insight into the behavioral characteristics of people who listen excessively to loud music, the 32-item Northeastern Excessive Music Listening Survey was developed and administered to 90 subjects. Results indicate that 8 of the 90 subjects scored within a range that would suggest the presence of a maladapti...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199812000-00003

    authors: Florentine M,Hunter W,Robinson M,Ballou M,Buus S

    更新日期:1998-12-01 00:00:00

  • Can You Hear What I Think? Theory of Mind in Young Children With Moderate Hearing Loss.

    abstract:OBJECTIVES:The first aim of this study was to examine various aspects of Theory of Mind (ToM) development in young children with moderate hearing loss (MHL) compared with hearing peers. The second aim was to examine the relation between language abilities and ToM in both groups. The third aim was to compare the sequenc...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000427

    authors: Netten AP,Rieffe C,Soede W,Dirks E,Korver AMH,Konings S,Briaire JJ,Oudesluys-Murphy AM,Dekker FW,Frijns JHM,DECIBEL Collaborative study group.

    更新日期:2017-09-01 00:00:00

  • Effect of peak clipping on speech recognition threshold.

    abstract::Speech recognition thresholds (SRTs) were measured for a closed set of spondees that had been processed by peak clipping and compression. Both hearing-impaired and normal-hearing subject groups showed progressively higher SRTs with increasing levels of peak clipping, with significant threshold shifts occurring for cli...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199412000-00005

    authors: Crain TR,Van Tasell DJ

    更新日期:1994-12-01 00:00:00

  • Initial independent results with the Clarion cochlear implant.

    abstract:OBJECTIVE:This paper reports some preliminary findings from patients, implanted at the University of Iowa, using the Advanced Bionics Clarion cochlear implant (version 1.0). We compared the performance of patients using both simultaneous analog and nonsimultaneous pulsatile processing strategies. The performance of Cla...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199612000-00008

    authors: Tyler RS,Gantz BJ,Woodworth GG,Parkinson AJ,Lowder MW,Schum LK

    更新日期:1996-12-01 00:00:00

  • Effects of presentation level on phoneme and sentence recognition in quiet by cochlear implant listeners.

    abstract:OBJECTIVE:The objectives of this study were to characterize the effects of presentation level on speech recognition in quiet by cochlear implant users with the Nucleus 22 SPEAK and Clarion v1.2 CIS speech-processing strategies, and to relate speech recognition at low presentation levels to stimulus audibility as measur...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000090340.09847.39

    authors: Donaldson GS,Allen SL

    更新日期:2003-10-01 00:00:00

  • Directionality in the interpretation of clinical auditory brain stem response measures.

    abstract::Clinical auditory brain stem response latency measures are conventionally evaluated for abnormality by reference to normative laboratory values in standard deviation units. This note suggests that the directionality of the test hypothesis should be considered when the clinical ABR is evaluated for abnormality at a pre...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199002000-00007

    authors: Sklare DA

    更新日期:1990-02-01 00:00:00

  • Results from a European clinical investigation of the Nucleus multichannel auditory brainstem implant.

    abstract:OBJECTIVE:This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus(R) multichannel auditory brainstem implant. DESIGN:Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects in...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-200206000-00002

    authors: Nevison B,Laszig R,Sollmann WP,Lenarz T,Sterkers O,Ramsden R,Fraysse B,Manrique M,Rask-Andersen H,Garcia-Ibanez E,Colletti V,von Wallenberg E

    更新日期:2002-06-01 00:00:00

  • Hearing in time: evoked potential studies of temporal processing.

    abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31827ada02

    authors: Picton T

    更新日期:2013-07-01 00:00:00