Comparison of the Motor Performance and Vestibular Function in Infants with a Congenital Cytomegalovirus Infection or a Connexin 26 Mutation: A Preliminary Study.

Abstract:

OBJECTIVES:Hearing-impaired children are at risk for vestibular damage and delayed motor development. Two major causes of congenital hearing loss are cytomegalovirus (CMV) infection and connexin (Cx) 26 mutations. Comparison of the motor performance and vestibular function between these specific groups is still underexplored. The objective of this study was to investigate the impact of congenital (c)CMV and Cx26 on the motor performance and vestibular function in 6 months old infants. DESIGN:Forty children (mean age 6.7 months; range 4.8 to 8.9 months) participated in this cross-sectional design and were recruited from the Flemish CMV registry. They were divided into five age-matched groups: normal-hearing control, asymptomatic cCMV, normal-hearing symptomatic cCMV, hearing-impaired symptomatic cCMV, and hearing-impaired Cx26. Children were examined with the Peabody Developmental Motor Scales-2 and cervical vestibular-evoked myogenic potential (cVEMP) test. RESULTS:Symptomatic hearing-impaired cCMV children demonstrated a significantly lower gross motor performance compared with the control group (p = 0.005), the asymptomatic cCMV group (p = 0.034), and the Cx26 group (0.016). In this symptomatic hearing-impaired cCMV group, 4 out of 8 children had absent cVEMP responses that were related to the weakest gross motor performance. The Cx26 children showed no significant delay in motor development compared with the control children and none of these children had absent cVEMP responses. CONCLUSIONS:The weakest gross motor performance was found in symptomatic hearing-impaired cCMV-infected children with absent cVEMP responses. These results suggest that abnormal saccular responses are a major factor for this delayed motor development, although more work is needed including comprehensive vestibular function testing to verify this.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Maes L,De Kegel A,Van Waelvelde H,De Leenheer E,Van Hoecke H,Goderis J,Dhooge I

doi

10.1097/AUD.0000000000000364

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

e49-e56

issue

1

eissn

0196-0202

issn

1538-4667

journal_volume

38

pub_type

杂志文章
  • Transfer functions and correction factors used in hearing aid evaluation and research.

    abstract::In hearing aid research and application it is often necessary to transform the sound pressure level or acoustic gain measured at one physical point (e.g., 2 cc coupler) to an equivalent value at another physical point (e.g., tympanic membrane). Results of currently available studies on various transformations are summ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198902000-00010

    authors: Bentler RA,Pavlovic CV

    更新日期:1989-02-01 00:00:00

  • Validating a Method to Assess Lipreading, Audiovisual Gain, and Integration During Speech Reception With Cochlear-Implanted and Normal-Hearing Subjects Using a Talking Head.

    abstract:OBJECTIVES:Watching a talker's mouth is beneficial for speech reception (SR) in many communication settings, especially in noise and when hearing is impaired. Measures for audiovisual (AV) SR can be valuable in the framework of diagnosing or treating hearing disorders. This study addresses the lack of standardized meth...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000502

    authors: Schreitmüller S,Frenken M,Bentz L,Ortmann M,Walger M,Meister H

    更新日期:2018-05-01 00:00:00

  • Speech recognition performance of patients with sensorineural hearing loss under unaided and aided conditions using linear and compression hearing AIDS.

    abstract:OBJECTIVES:This study compared speech recognition performance on the Northwestern University Auditory Test No. 6 (NU-6) and the Connected Speech Test (CST) for three hearing aid circuits (peak clipping [PC], compression limiting [CL], and wide dynamic range compression [WDRC]) in adults with symmetrical sensorineural h...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200208000-00003

    authors: Shanks JE,Wilson RH,Larson V,Williams D

    更新日期:2002-08-01 00:00:00

  • The effect of hearing aid microphone mode on performance in an auditory orienting task.

    abstract:OBJECTIVES:Although directional microphones on a hearing aid provide a signal-to-noise ratio benefit in a noisy background, the amount of benefit is dependent on how close the signal of interest is to the front of the user. It is assumed that when the signal of interest is off-axis, users can reorient themselves to the...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000053

    authors: Brimijoin WO,Whitmer WM,McShefferty D,Akeroyd MA

    更新日期:2014-09-01 00:00:00

  • Judgments of hearing aid processed music.

    abstract::Paired comparison perception and preference judgments of hearing aid processed music were examined under conditions of extended and reduced high and low-frequency ranges. The performance of 20 subjects with mild to moderate hearing impairment was compared with an equal number of normal hearing controls. Subjects with ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198201000-00004

    authors: Franks JR

    更新日期:1982-01-01 00:00:00

  • Behavioral Pure-Tone Threshold Shifts Caused by Tympanic Membrane Electrodes.

    abstract:OBJECTIVE:To determine whether tympanic membrane (TM) electrodes induce behavioral pure-tone threshold shifts. DESIGN:Pure-tone thresholds (250 to 8000 Hz) were measured twice in test (n = 18) and control (n = 10) groups. TM electrodes were placed between first and second threshold measurements in the test group, wher...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000275

    authors: Smith SB,Lichtenhan J,Cone B

    更新日期:2016-07-01 00:00:00

  • Reversible sensorineural hearing loss in a stroke patient.

    abstract::A case is presented of a patient with lateral pontine stroke which resulted in a moderate unilateral sensorineural hearing loss. ABR, word recognition scores, acoustic reflexes, neurological evaluation, and CT scan were consistent with brain stem lesion. Recovery of hearing, including acoustic reflexes and word recogn...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Bales JD

    更新日期:1989-04-01 00:00:00

  • Monothermal Caloric Screening to Improve Healthcare Value.

    abstract:OBJECTIVES:To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN:Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary refe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000262

    authors: Thatcher AL,Beckerman ML,Telian SA,King WM

    更新日期:2016-05-01 00:00:00

  • The effect of reference microphone placement on sound pressure levels at an ear level hearing aid microphone.

    abstract::The present study was designed to investigate the effects of reference microphone location on probe tube microphone measures of hearing aid response. The reference microphone of a clinical probe tube microphone system was located either at a position on the cheek (position A) or in close proximity to the microphone of...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199010000-00001

    authors: Feigin JA,Barlow NL,Stelmachowicz PG

    更新日期:1990-10-01 00:00:00

  • Retest stability of the communication profile for the hearing impaired.

    abstract::Retest stability of the Communication Profile for the Hearing Impaired (CPHI) was assessed in a sample of 101 active-duty military personnel who attended the Aural Rehabilitation Program at Walter Reed Army Medical Center. Pretests were administered by referring audiologists; retests were administered from 6 to 40 wee...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198810000-00002

    authors: Demorest ME,Erdman SA

    更新日期:1988-10-01 00:00:00

  • Noise-induced otoacoustic emission loss with or without hearing loss.

    abstract::The association between audiometric hearing thresholds and click-evoked otoacoustic emission (CEOAE) spectral properties was examined in 129 adult subjects with and without a noise-induced hearing loss (NIHL). Subjects were grouped according to their "beginning of hearing loss frequency" and their exposure to hazardou...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199512000-00007

    authors: Attias J,Furst M,Furman V,Reshef I,Horowitz G,Bresloff I

    更新日期:1995-12-01 00:00:00

  • Acquiring language through total communication.

    abstract::Total communication provides an opportunity for very young children to receive training through both visual and auditory systems. Most children with severe hearing loss have auditory discrimination/perceptual problems in addition to a loss of hearing sensitivity. Because sophisticated assessment of auditory perceptual...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198501000-00008

    authors: Thompson MD,Swisher MV

    更新日期:1985-01-01 00:00:00

  • Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor.

    abstract:OBJECTIVE:To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200110000-00007

    authors: Faulkner A,Rosen S,Wilkinson L

    更新日期:2001-10-01 00:00:00

  • Impact of laser eustachian tuboplasty on middle ear ventilation, hearing, and tinnitus in chronic tube dysfunction.

    abstract:OBJECTIVES:Long-term Eustachian tube dysfunction (ETD) predisposes to various secondary middle ear diseases. Most surgical and prosthetical interventions on the Eustachian tube itself have proven to be ineffective, whereas middle ear surgeries treat the sequelae of ETD without major influence on the underlying tubal pa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181e85614

    authors: Caffier PP,Sedlmaier B,Haupt H,Göktas O,Scherer H,Mazurek B

    更新日期:2011-02-01 00:00:00

  • The leisure-noise dilemma: hearing loss or hearsay? What does the literature tell us?

    abstract::The authors undertook a review of the literature, focussing on publications describing the following: (1) Pure tone threshold data for adolescents/young adults; (2) Measurements/estimates of noise exposure from leisure activities; and (3) The relationship between hearing threshold levels (HTLs) and leisure-noise expos...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/01.aud.0000451498.92871.20

    authors: Carter L,Williams W,Black D,Bundy A

    更新日期:2014-09-01 00:00:00

  • Application of the kurtosis statistic to the evaluation of the risk of hearing loss in workers exposed to high-level complex noise.

    abstract:OBJECTIVE:Develop dose-response relations for two groups of industrial workers exposed to Gaussian or non-Gaussian (complex) types of continuous noises and to investigate what role, if any, the kurtosis statistic can play in the evaluation of industrial noise-induced hearing loss (NIHL). DESIGN:Audiometric and noise e...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181d94e68

    authors: Zhao YM,Qiu W,Zeng L,Chen SS,Cheng XR,Davis RI,Hamernik RP

    更新日期:2010-08-01 00:00:00

  • Callsign Acquisition Test (CAT): speech intelligibility in noise.

    abstract:OBJECTIVE:The study was designed to assess the effects of noise on the intelligibility of speech elements used in the Callsign Acquisition Test (CAT), developed by the U.S. Army Research Laboratory. The CAT consists of 126 test items, or callsigns, each of which is made up of a two-syllable word selected from the 18-it...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000202289.32228.f6

    authors: Rao MD,Letowski T

    更新日期:2006-04-01 00:00:00

  • Using Thresholds in Noise to Identify Hidden Hearing Loss in Humans.

    abstract:OBJECTIVES:Recent animal studies suggest that noise-induced synaptopathy may underlie a phenomenon that has been labeled hidden hearing loss (HHL). Noise exposure preferentially damages low spontaneous-rate auditory nerve fibers, which are involved in the processing of moderate- to high-level sounds and are more resist...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000543

    authors: Ridley CL,Kopun JG,Neely ST,Gorga MP,Rasetshwane DM

    更新日期:2018-09-01 00:00:00

  • SSW test performance-intensity functions for hearing-impaired adults.

    abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198411000-00004

    authors: Flynn PA,Danhauer JL,Gerber SE,Goller MC,Arnst DJ

    更新日期:1984-11-01 00:00:00

  • Family Environment in Children With Hearing Aids and Cochlear Implants: Associations With Spoken Language, Psychosocial Functioning, and Cognitive Development.

    abstract:OBJECTIVES:To examine differences in family environment and associations between family environment and key speech, language, and cognitive outcomes in samples of children with normal hearing and deaf and hard-of-hearing (DHH) children who use hearing aids and cochlear implants. DESIGN:Thirty families of children with...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000811

    authors: Holt RF,Beer J,Kronenberger WG,Pisoni DB,Lalonde K,Mulinaro L

    更新日期:2020-07-01 00:00:00

  • Auditory Distraction and Acclimatization to Hearing Aids.

    abstract:OBJECTIVE:It is widely recognized by hearing aid users and audiologists that a period of auditory acclimatization and adjustment is needed for new users to become accustomed to their devices. The aim of the present study was to test the idea that auditory acclimatization and adjustment to hearing aids involves a proces...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000366

    authors: Dawes P,Munro KJ

    更新日期:2017-03-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Relevance of Artifact Removal and Number of Stimuli for Video Head Impulse Test Examination.

    abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000849

    authors: Trinidad-Ruiz G,Rey-Martinez J,Matiño-Soler E,Batuecas-Caletrio A,Martin-Sanz E,Perez-Fernandez N

    更新日期:2020-09-01 00:00:00

  • Distortion product otoacoustic emission response characteristics in older adults.

    abstract:OBJECTIVE:The primary purpose of this study was to determine the distortion product otoacoustic emission (DPOAE) and noise response characteristics in a large sample of older adults. Another purpose was to evaluate how specific absolute DPOAE levels or DPOAE/Noise ratios differentiated hearing status in these individua...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000051847.66944.2B

    authors: Torre P 3rd,Cruickshanks KJ,Nondahl DM,Wiley TL

    更新日期:2003-02-01 00:00:00

  • Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users.

    abstract:OBJECTIVES:In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000135

    authors: Kan A,Litovsky RY,Goupell MJ

    更新日期:2015-05-01 00:00:00

  • Exchange rates for intermittent and fluctuating occupational noise: a systematic review of studies of human permanent threshold shift.

    abstract:OBJECTIVE:The aim of this study was to review the literature regarding human noise-induced permanent threshold shift and to determine whether the observed data agreed with the predictions of two different exchange rates (ERs). DESIGN:An initial list of possibly relevant studies included those cited by authors who endo...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e3182a143ec

    authors: Dobie RA,Clark WW

    更新日期:2014-01-01 00:00:00

  • Effect of eye closure, mental concentration, and nonauditory sensory stimulation on the threshold and magnitude of the acoustic reflex.

    abstract::Acoustic reflex threshold and magnitude were measured for normal-hearing subjects in four experiments under conditions of: (1) tight and relaxed eyelid closure; (2) eyes open and closed in light, focusing on a spot, reading, and solving a visual maze; (3) tactile stimulation; and (4) performing a mental task. Measurem...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198207000-00007

    authors: Robinette MS,Snyder KS

    更新日期:1982-07-01 00:00:00

  • Effects of a Nucleus multichannel cochlear implant upon speech production in children.

    abstract::The purpose of this report is to describe the speech production of children participating in the Food and Drug Administration's approved clinical trials for the Nucleus multichannel cochlear implant. A significant increase in the ability to imitate nonsegmental aspects of speech was noted after using the implant; howe...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/00003446-199108001-00007

    authors: Tobey EA,Hasenstab S

    更新日期:1991-08-01 00:00:00

  • Binaural Pitch Fusion in Children With Normal Hearing, Hearing Aids, and Cochlear Implants.

    abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000874

    authors: Hartling CL,Fowler JR,Stark GN,Glickman B,Eddolls M,Oh Y,Ramsey K,Reiss LAJ

    更新日期:2020-11-01 00:00:00

  • Pitfalls in neurotologic diagnosis.

    abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198804000-00007

    authors: Telian SA,Kileny PR

    更新日期:1988-04-01 00:00:00